Használati útmutató Emko CHANNEL8A-N

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Emko CHANNEL8A-N (4 oldal) a Temperatuurregelaar kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/4
ENGCHANNEL8A-N01V0003/17
CHANNEL8A-N
8CHANNEL ANALOGSCANNER
96x96DIN1/4
12±1mm/0.47inch 84mm/3.31inch
15 0.59inchmm/
92mm/3.62inch
92mm/3.62inch
129mm/5.08inch(min)
129mm/5.08inch(min)
320x240Pixel
TFT LCD
Standart
Function
Buttons
MENU BUTTON
Used to access Menu page.
ENTER BUTTON
Used to go in to selected page, to make parameter's cell
available tochange and to confirm parameter’s change.
AUTO BUTTON
Used to auto-scan pages.
BACK BUTTON
Used to go back to previous menu and to cancel
parameter's change.
UP BUTTON
Used to go up in menus and lists and also used to increase
parameter's value.
LEFTBUTTON
Usedtogoleftinmenus.
DOWNBUTTON
Usedtogodowninmenusandlistsandalsousedto
decreaseparameter'svalue.
RIGHTBUTTON
Usedtogorightinmenus.
F4
F1 F2 F3
DELETEBUTTON
Usedtoeraselogsonthescreen.
SETTINGS
LOGS
ADVANCE
SETTINGS
LANGUAGE
CHANNEL8A-N8Channel AnalogScanner
-320x240pixelTFTLCDdisplay
-8 Analoginputs
-ON-OFFcontrol
-Relayor(pnp “source”)transistoroutput
-Sensorerrordetection
- Adjustabletemperatureoffset
-3Differentalarmandpre-alarmtypesforeachchannel
(High,LowandBand Alarms)
-Userdefinedchannellabels
-Displayscanmodes
-OperatingwithRealTimeClock(RTC)
-ModBusRTUcommunicationprotocol
(RS-232,RS-485andEthernetcommunication)
-DataLoggingtoUSBFlashMemory
- Adjustabledataloggingtimeinterval
-Passwordprotectionforprogrammingmode
CHANNEL8A-N series 8 channel analog scanner devices are designed
for measuring and logging temperature. They can be used in many
applications with their, alarm outputs, selectable alarm functions, RS-
232 / RS-485 / Ethernet / USB communications.
SPECIFICATIONS
INPUT
AnalogInputs:
Accuracy:
SamplingTime:
OUTPUT
Relay:
DISPLAY
LCDDisplay:
POWERSUPPLY
ENVIRONMENTAL RATINGS
OperatingTemperature:
Humidity:
ProtectionClass:
PHYSICAL SPECIFICATIONS
Weight:
Dimension :
Panel Cut-Out :
0-20mA /4-2mA and0-10VDC Analogue
±0.25%offullscale
400ms
ax.1A@24V
320x240
0...50°C
0-90%RH(nonecondensing)
IP65atfront,IP20atrear
0gr.
96 x 96 mm, Depth:96 mm
92 x 92 mm
W
W
40
Resolution:
InputRessistance:
Transistor:
14Bits
100 for0-20mA inputand
68k for0-10Vinput
ResistiveLoad5A@250V
(ElectricalLife:100.000operation(FullLoad)
PNP(source)typetransistoroutput(M )
pixel TFT LCD
100-240V (-%15/+%10)50/60Hz.7VA
24V (-%15/+%10)50/60Hz.7VA
24V (-%15/+%10)7W
(Itmustbedeterminedinorder.)
V
Z
V
V
Z
ElectricalWiringDiagram
DevicewithRelayOutputs
RS232
COMMUNICATION
5x5A@250V
COMMON-1
COMMON-2
16 21 22 23 24 25 26 27 28 29 3017 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CH-1 ALARM
OUTPUT
CH-
OUTPUT
2 ALARM
CH-
OUTPUT
3 ALARM
CH-
OUTPUT
4 ALARM
CH-
OUTPUT
5 ALARM
CH-
OUTPUT
6 ALARM
CH-
OUTPUT
7 ALARM
CH-
OUTPUT
8 ALARM
GENERAL ALR.
OUTPUT
GENERAL PRE-ALR.
OUTPUT
5x5A@250V
USB2.0
COMMUNICATION
ETHERNET
OR
RS485
COMMUNICATION
CH-1CH-2CH-3CH-4CH-5CH-6CH-7CH-8
100...240V-%15;+%10)50/60Hz7VA
24V(-%15;+%10)50/60Hz7VA
24V(-%15;+%10)7W
L
(+)
N
(-)
DevicewithTransistorOutputs
RS232
COMMUNICATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
USB2.0
COMMUNICATION
ETHERNET
OR
RS485
COMMUNICATION
100...240V(-%15;+%10)50/60Hz7VA
24V(-%15;+%10)50/60Hz7VA
24V(-%15;+%10)7W
L
(+)
N
(-)
iRS485, Ethernet and USB communications are optional
16 21 22 23 24 25 26 27 28 29 3017 18 19 20
CH-1 ALARM
OUTPUT
CH-
OUTPUT
2 ALARM
CH-
OUTPUT
3 ALARM
CH-
OUTPUT
4 ALARM
CH-
OUTPUT
5 ALARM
CH-
OUTPUT
6 ALARM
CH-
OUTPUT
7 ALARM
CH-
OUTPUT
8 ALARM
GENERAL ALR.
OUTPUT
GENEAL PRE- ALR.
OUTPUT
10x1A@24V
TRANSISTOROUTPUTS
POWERSUPPLY
24V±%15
iRS485, Ethernet and USB communications are optional
RelayOutputs
(AlarmOutputsfor
Channels6to8,
General AlarmOutputand
GeneralPre-AlarmOutput)
CH=CHANNEL
PowerSupplyInput
(Itmustbedeterminedinorder.)
Common1 Common2
RelayOutputs
(AlarmOutputsfor
Channels1to5)
PowerSupplyInput
(Itmustbedeterminedinorder.)
TransistorOutputs
(AlarmOutputsfor
Channels1to8,
General AlarmOutputand
GeneralPre-AlarmOutput)
CH=CHANNEL
Maximum
CHANNEL8A-NFrontViewandDimensionsof
PanelCut-Out
1-Before mounting the device
in your panel, make sure that
the cut-out is of the right size.
2-Check front panel gasket
position
3-Insert the device through the
cut-out. If the mounting clamps
are on the unit, put out them
before inserting the unit to the
panel.
PanelMounting
InstallationFixingClamp
The unit is designed for panel
mounting.
1-Insert the unit in the panel
cut-out from the front side.
2- Insert the mounting clamps
to the holes that located top
and bottom sides of device and
screw up the fixing screws until
the unit completely immobile
within the panel.
RemovingfromthePanel
1-Loosen the screws.
2-Pull mounting clamps from
top and bottom fixing sockets.
3-Pull the unit through the
front side of the panel
DefinitionofFrontPanel
AGND
ProcessInputs
(4-20mA /0-20mA)
(0-10V)
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0
-10VZ
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
AGND
ProcessInputs
(4-20mA /0-20mA)
(0-10V)
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
ı
+
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10 VZ
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10VZ
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
0-20mA Z
0-10V Z
4-20mA Z
CH-1CH-2CH-3CH-4CH-5CH-6CH-7CH-8
96mm/3.78inch
96mm/3.78inch
F1 F2 F3 F4
A
1
2
3
F1 F2 F 3 F4
A
1
2
F1 F2 F 3 F4
A
F4F1 F2 F3
A
3
1
2
F1 F2 F 3 F4
A
MAINOPERATIONSCREEN
MAINOPERATION(CHANNEL-1SCREEN)
i
i
i
MENUSCREEN
OPERATORPARAMETERS
PASSWORDSCREEN
PressF1orF2directionbuttons
tomovetotheSettingstab.
WhentheF1menubuttonispressed
whilethemainscreenisonthepage,the
menupageisdisplayed.
PARAMETERS
CHANGE
PARAMETERS
CHANGE
OPERATORPARAMETERS
(CHANNEL-1PARAMETERS)
PressF3button.Ifpassword
isdifferentfrom0,password
screenopens.
Enterthepasswordvalueusing
theF1andF2buttons.
Confirmthecharactersoneby
onebypressingF3button.
Onceyouhaveconfirmedthe
lastcharacter,youwillproceed
totheoperatorparameters
screen.
PresstheF1andF2buttonsto
highlightthechannelandpresstheF3
button.
Selecttherelevantparameter
withtheF1andF2buttons.
PresstheF3buttontoselect
theparameter.
UsetheF1andF2buttonstochange
thevalueoftheparameter.
PresstheF3buttontosave
theparametervalue.
DEVICESETTINGS
(Rs485SETTINGS)
DEVICESETTINGS
(USBSETTINGS)
DEVICESETTINGS
(ETHERNETSETTINGS)
DEVICESETTINGS
(DATETIMESETTINGS)
WiththeF1andF2buttonsyoucan
selectandchangetheUSB
parameters.UsetheF3buttonto
save.
WiththeF1andF2buttonsyoucan
selectandchangetheRS485
parameters.UsetheF3buttonto
save.
WiththeF1andF2buttonsyoucan
selectandchangetheETHERNET
parameters.UsetheF3buttonto
save.
WiththeF3buttonyoucanselectthe
Dateand Timeparametersandyou
canchangethevaluewiththeF1,F2
buttons.
i
i
i
ChannelNumber
DeviceFunction
Buttons
Alarm Set
Alarm set value for selected channel is can be adjusted according to this parameter.
It can be adjust between -200 0
O O
C to +65 C.
Pre. Alarm Set
Pre- Alarm set value for selected channel is can be adjusted according to this
parameter. It can be adjust between -200 0
O O
C to +65 C.
i
F4F1 F2 F3
ChannelLabel
PreAlarmStatus
AlarmStatus
ChannelsNames
ProcessValue
F4F1 F2 F3
F4F1 F2 F3
AlarmMessages
ChannelOutput
Status
ChannelNumber
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3
F1
F1 F2
F3
F1
F2
F3
F1
F2
F1
F2 F3
F1
F2
OperatorPasswordChange
Passwordfordeviceisadjustedbythisparameter.Operator
DEVICESETTINGS
(PASSWORDCHANGE)
UsetheF1andF2buttonstochange
thevalueoftheparameter.Confirmthe
charactersonebyonebypressingF3
button.
UsetheF1buttontomoveto
the"YES"tabandpresstheF3
button.In1-3secondsthe
devicewillreturntofactory
settings.
F4F1 F2 F3 F4F1 F2 F3
TECHNICIANPARAMETERS
(CONTROL PARAMETERS
TECHNICIANPARAMETERS
PASSWORDSCREEN
TECHNICIANPARAMETERS
PASSWORDSCREEN
TECHNICIANPARAMETERS
PASSWORDINPUTSCREEN
PressF1orF2directionbuttons
tomovetothe Advanced
Settingstab.
PARAMETERS
CHANGE
DEVICESETTINGS
(RS232SETTINGS)
PressF3button.Ifpassword
isdifferentfrom0,password
screenopens.
Enterthepasswordvalueusing
theF1andF2buttons.
Confirmthecharactersoneby
onebypressingF3button.
Onceyouhaveconfirmedthe
lastcharacter,youwillproceed
totheoperatorparameters
UsetheF1andF2buttonstoscrollto
theControlparametersandpressthe
F3button.
SelecttherelevantchannelwiththeF1
andF2buttons.
PresstheF3buttontoselect
theparameter.
UsetheF1andF2buttonstochange
thevalueoftheparameter.Pressthe
F3buttontosavetheparametervalue.
WiththeF1andF2buttonsyou
canselectandchangetheRS232
parameters.UsetheF3buttonto
save.
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3 F4F1 F2 F3
F4F1 F2 F3F4F1 F2 F3
F1
F1 F2
F3
F1
F2
F3
F1
F2
F1
F2 F3
F3
F3
F3
F3
TECHNICIANPARAMETERS
(CHANNEL-1)
TECHNICIANPARAMETERS
(CHANNEL-1PARAMETERS)
MainOperationScreensDefinetion AccessingtotheOperatorParameterPages
IfthedisplaytypeparametervalueScreenType=MULTIPLE
If the display scan parameter value Screen Change = ENABLE, each main
operation screen is showing on LCD screen during time defined by Change
Time parameter value.
IfthedisplaytypeparametervalueScreenType=SINGLE
ChannelName
ProcessValue
MAINOPERATION(CHANNEL-4SCREEN)
Pressnumber
F2orF3
buttonsfor
accessingthe
relevantchannel
screen.
If the display scan parameter value Screen Change = ENABLE, each main
operation screen is showing on LCD screen during time defined by Change
Time(sec) parameter value
If more than one alarm messages is present, each alarm message is
showing on LCD screen during 1 second.
MAINOPERATIONSCREEN
OPERATORPARAMETERS
PASSWORDSCREEN
OPERATORPARAMETERS
PASSWORDINPUTSCREEN
OPERATORPARAMETERS
(CHANNEL-1)
OPERATORPARAMETERS
(CHANNEL-1PARAMETERS)
AccessingtotheTechnicianParameterPages
OperatorPagesParametersDefinetions
If no operation is performed for 20 seconds in operator parameters section,
device turns to main operation screen automatically.
If the device has a optional RS485 communication then RS 485 page is
observed, If the device has a optional USB communication then USB page is
observed.
If no operation is performed for 20 seconds in operator or technician
parameters section, device turns to main operation screen automatically.
If the device has a optional ETHERNET communication then ETHERNET
page is observed, otherwise this page is not observed.
MAINOPERATIONSCREEN
MENUSCREEN
WhentheF1menubuttonispressed
whilethemainscreenisonthepage,the
menupageisdisplayed.
DEVICESETTINGS
(DEFAULTSETTINGS)
A
A
A
A A
A A
A A
A A
A A
A A
A A
AA
AA
A A
AA
AA
A A
A
UnitSelect
Type of unit value is adjusted according to this parameter for selected channel which is
shown on display.The value of parameter C, Bar, Ph, %, mm, m.
O
Hysteresis
Hysteresis parameter value for Alarm and Pre-Alarm is can be adjusted by this
parameter. It can be adjust between -400 0
O O
C to +40 C.
Band Alarm
Bandwith for Band alarm is can be adjusted by this parameter value.
It can be adjust between -400 0
O O
C to +40 C.
Sensor Alarm
Sensor break alarm for selected channel is can be disable or enable by this parameter.
It can be adjust between 0 to 1. Parameter values;
0 = DISABLE
1 = ENABLE
Offset
Process offset value for selected channel is can be adjusted by this parameter.
It can be adjust between -50.0 0
O O
C to +50. C.
ControlParameters-OtherParameters
Screen Type
Main operation screen type is adjusted by this parameter.
It can be adjust between 0 to 1. Parameter values;
0 = MULTIPLE
1 = SINGLE
Screen Change
It can be adjust between 0 to 1. Parameter values;
0 = DISABLE
1 = ENABLE
Display channel scanner mode is adjusted by this parameter.
Change Time(sec)
Display scan period is adjusted by this parameter. All main operation screen is
displayed during time defined by this parameter. It can be adjust between 1 to 3600
secs.
Baudrate
It can be adjust between 0 to 5. Parameter values;
0 = 4800 3 = 38400
1 = 9600 4 = 57600
2 = 19200 5 = 115200
Modbus communication baudrate for RS232 is can be adjusted by this parameter.
Parity
It can be adjust between 0 to 2. Parameter values;
0 = NONE
1 = ODD
2 = EVEN
Modbus communication parity bit for RS232 is can be adjusted by this parameter.
Stop Bit
It can be adjust between 1 to 2. Parameter values;
1 = 1 Stop bit
2 = 2 Stop bits
Modbus communication stop bit for RS232 is can be adjusted by this parameter.
Id
Modbus communication device ID for RS232 is can be adjusted by this parameter.
This parameter value is can be adjusted from 1 to 247.
File Name
USB file name for recording analogue values is can be adjusted by this parameter. File
name can be adjusted maximum 10 characters. Recording file on usb is csv format“ ”
and all data is seperated each other with tab. Example file format is explained below.
Label
When the analogue values are recorded on USB file, user can be defined label for this
recording. Label can be adjusted maximum 10 characters. Label are recorded at the
end of every lines of file.
Date Record
It can be adjust between 0 to 1. Parameter values;
0 = DISABLE
1 = ENABLE
When the analogue values are recorded on USB file, user can be save the recording
time on the file. Recording time is recorded at the beginning of every lines of file.
Record Time(sec)
It can be adjust between 0 to 3600 secs.
Record time interval is can be adjusted by this parameter. Analogue values are
recorded on USB file with this time interval. If
this parameter value is 0 usb recording is disabled.
Flash Memory “USB Flash Memory Stick Detected Test”
Detection of the USB memory device being inserted is tested with this parameter.
When the USB memory device is plugged in, the message "OK" is displayed.
DHCP
It can be adjust between 0 to 1. Parameter Values;
0 = DHCP DISABLE
1 = DHCP ENABLE
DHCP is an automatic configuration protocol used on IP networks, If DHCP is enable,
device is adjust our ethernet communication configuration parameters (IP,
Netmask,Gateway) dynamicaly for your network system. If DHCP is disable, you must
adjust ethernet configuration parameters (IP, Netmask,Gateway) for your network
system.
Port No
Ethernet port number is can be adjusted by this parameter.
Netmask
Subnet mask for ethernet communication is can be adjusted by this parameter. If
DHCP is selected as a enable there is no need to adjust to this parameter, if DHCP is
selected as a disable then user must adjust this parameter according to the their own
network system.
Gateway
Gateway for ethernet communication is can be adjusted by this parameter. If DHCP is
selected as a enable there is no need to adjust to this parameter, if DHCP is selected as
a disable then user must adjust this parameter according to the their own network
system.
Ip No
IP address for ethernet communication is can be adjusted by this parameter. If DHCP
is selected as a enable there is no need to adjust to this parameter, if DHCP is selected
as a disable then user must adjust this parameter.
Channel Status
It can be adjust between 0 to 1. If parameter value
0 = DISABLE
1 = ENABLE
Channel is enabled and disabled by this parameter. If channel is selected as a disabled
this channel is can not be observed in main operation scren for single view mode,
channel alarm is not be controlled and analogue value for this channel is can not be
recording on USB file. ,
Channel Name “ Channels label definition
All channels have their own label, is displayed in main operation screen. channel labels is can
be adjusted by this parameter. Channel labels are can be adjusted maximum 10 characters.
Alarm Type
Alarm type for selected channel is can be adjusted according to this parameter.
It can be adjust between 0 to 2. Parameter values;
0 = LOW 1 = HIGH 2 = BAND
PreAlarm Type
Pre-Alarm type for selected channel is can be adjusted according to this parameter.
It can be adjust between 0 to 2. Parameter values;
0 = LOW 1 = HIGH 2 = BAND
BackLightOnLevel
Display backlight is can be controlled by this parameter value. It can be adjust
between 50 to 100.
BackLightOffLevel
CO mode for backlight; in case off selection no backlight . ThisE parameter is can be
adjusted from 1 to 100.
BackLightOffTime
Time for the access to ecomomic backlight mode. This parameter is can be adjusted
from 10 to 300.
DeviceSettings-RS-232Settings
DeviceSettings-RS-485Settings
Baudrate
It can be adjust between 0 to 5. Parameter values;
0 = 4800
1 = 9600
2 = 19200
3 = 38400
4 = 57600
5 = 115200
Modbus communication baudrate for RS485 is can be adjusted by this parameter.
Parity
It can be adjust between 0 to 2. Parameter values;
0 = NONE
1 = ODD
2 = EVEN
Modbus communication parity bit for Rs485 is can be adjusted by this parameter.
Stop Bit
It can be adjust between 1 to 2. Parameter values;
1 = 1 Stop bit
2 = 2 Stop bits
Modbus communication stop bit for Rs485 is can be adjusted by this parameter.
Id
Modbus communication device ID for Rs485 is can be adjusted by this parameter.
This parameter value is can be adjusted from 1 to 247.
DeviceSettings-USBSettings
DeviceSettings-ETHERNETSettings
TcpIp Selection
It can be adjust between 0 to 1.
0 = Modbus RTU Over TCP/IP
1 = Modbus RTU TCP/IP
TCP/IP Protocol is can be adjusted by this parameter.
DeviceSettings-DefaultSettings
Thissectionisusedtoreturndefaultsettingsback.
DeviceSettings-DateandTimeSettings
Date and Time for device is adjusted by this parameter.
DeviceSettings-PasswordChange
Technician Password for device is adjusted by this parameter.
DeviceSettings-SoftwareUpdate
It allows you to update the device's software with a USB flash memory.
Logs
In this page, events logs are shown.
LanguageSelection
Inthispage,thelanguageisselectedforthedevice.
F4F1 F2 F3
F4F1 F2 F3
SET
HYS
BAND
=
=
=
Alarm or Pre-Alarm Set value
Hysteresis value forAlarm and Pre-Alarm output
Bandwidth for Band Alarm.
ON
OFF
Process Value
ON
OFF
Alarm
Output
Process Value
Alarm
Output
SET
HYS
SET
HYS
ON
OFF
Alarm
Output
Process Value
BandAlarm
LowAlarm
HighAlarm
OperationGraphicsof AlarmandPre-AlarmTypes
i
Modbus Addresses
OutputStatus Addresses
OutputsStatus Addresses Unit
CH-1 ALARMOUT Channel-1 AlarmOutputStatus
Address
00001
-
CH-2 ALARMOUT Channel-2 AlarmOutputStatus 00002
-
CH-3 ALARMOUT Channel-3 AlarmOutputStatus 00003
-
CH-4 ALARMOUT Channel-4 AlarmOutputStatus 00004
-
CH-5 ALARMOUT Channel-5 AlarmOutputStatus 00005
-
CH-6 ALARMOUT Channel-6 AlarmOutputStatus 00006
-
CH-7 ALARMOUT Channel-7 AlarmOutputStatus 00007
-
CH-8 ALARMOUT Channel-8 AlarmOutputStatus 00008
-
GEN. ALR.OUT General AlarmOutputStatus 00009
-
GEN.PRE.ALR.OUT GeneralPre-alarmOutputStatus 00010
-
Note-1: Outputs status are can be readed with modbus function-1 (read coils).
Device s response for modbus function-1 is always 2 byte data although the modbus
function request less than 9 outputs port.
ProcessValues Addresses
ProcessValues Addresses Unit
CH-1P.VALUE Channel-1ProcessValue
Address
30001
CH-2P.VALUE Channel-2ProcessValue 30002
CH-3P.VALUE Channel-3ProcessValue 30003
CH-4P.VALUE Channel-4ProcessValue 30004
CH-5P.VALUE Channel-5ProcessValue 30005
CH-6P.VALUE Channel-6ProcessValue 30006
CH-7P.VALUE Channel-7ProcessValue 30007
CH-8P.VALUE Channel-8ProcessValue 30008
Note-2: Process values are can be readed with modbus function-4 (read input
register). Because of the process values are displayed on LCD screen with point, the
reading valuesfrom modbus is 10 times than the real values.
ParametersModbus Addresses
ParameterValues Addresses Unit
CH-1NAME Channel-1Name
Address
42000-42004
CH-2NAME Channel-2Name 42005-42009String 42005-42009
CH-3NAME Channel-3Name 42010-42014
CH-4NAME Channel-4Name 42015-42019
CH-5NAME Channel-5Name 42020-42024
CH-6NAME Channel-6Name 42025-42029
CH-7NAME Channel-7Name 42030-42034
CH-8NAME Channel-8Name 42035-42039
String
String
String
String
String
String
String
FILENAME USBFileName 42040-42044String
LABEL USBLabel 42045-42049String
CH-1 ALARMSET Channel-1 AlarmSetValue 42050
CH-1PRE A.SET Channel-1PrealarmSetValue 42051
CH-1HYSTERESIS Channel-1HysteresisValue 42052
CH-1BAND ALARM Channel-1BandwithValue 42053
CH-2 ALARMSET Channel-2 AlarmSetValue 42054
CH-2PRE A.SET Channel-2PrealarmSetValue 42055
CH-2HYSTERESIS Channel-2HysteresisValue 42056
CH-2BAND ALARM Channel-2BandwithValue 42057
CH-3 ALARMSET Channel-3 AlarmSetValue 42058
CH-3PRE A.SET Channel-3PrealarmSetValue 42059
CH-3HYSTERESIS Channel-3HysteresisValue 42060
CH-3BAND ALARM Channel-3BandwithValue 42061
CH-4 ALARMSET Channel-4 AlarmSetValue 42062
CH-4PRE A.SET Channel-4PrealarmSetValue 42063
CH-4HYSTERESIS Channel-4HysteresisValue 42064
CH-4BAND ALARM Channel-4BandwithValue 42065
CH-5 ALARMSET Channel-5 AlarmSetValue 42066
CH-5PRE A.SET Channel-5PrealarmSetValue 42067
CH-5HYSTERESIS Channel-5HysteresisValue 42068
CH-5BAND ALARM Channel-5BandwithValue 42069
CH-6 ALARMSET Channel-6 AlarmSetValue 42070
CH-6PRE A.SET Channel-6PrealarmSetValue 42071
CH-6HYSTERESIS Channel-6HysteresisValue 42072
CH-6BAND ALARM Channel-6BandwithValue 42073
CH-7 ALARMSET Channel-7 AlarmSetValue 42074
CH-7PRE A.SET Channel-7PrealarmSetValue 42075
CH-7HYSTERESIS Channel-7HysteresisValue 42076
CH-7BAND ALARM Channel-7BandwithValue 42077
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
*
()
SET(SET -(BAND/2)) (SET +(BAND/2))
HYS HYS
TechnicianParameters
TechnicianPagesParametersDefinetions
USB Recording File Example
2011-06-23-17:26:09130.6129.1130.5129.5130.0129.9130.3129.1SAMPLE
2011-06-23-17:26:10130.6129.1130.5129.5130.0129.9130.3129.1SAMPLE
2011-06-23-17:26:12130.6129.1130.5129.5130.0129.9130.3129.1SAMPLE
2011-06-23-17:26:13130.6129.1130.5129.5130.0129.9130.3129.1SAMPLE
Recording Time CH-1
Value
CH
Value
-2 CH
Value
-3 CH
Value
-4 CH
Value
-5 CH
Value
-6 CH
Value
-7 CH
Value
-8 Label
Calib. Low
Calibration Low value for selected channel can be adjusted according to this
parameter.
Calib. High
Calibration High value for selected channel can be adjusted according to this
parameter.
Sensor Type
Analogue input signal to be applied according to this parameter for selected channel
which is shown on Display.
0 = 4-20 mA 1 = 0-20 mA 2 = 0-10 V
A
A
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
OC/Ph/Bar
Internal Recording
The device can record in memory. When a USB memory is inserted, the recordings are
transferred to the USB memory with the file name containing the current date and
time.(Exp: 2017-07-30-09-08-12-CHAN8.txt) icon and transaction status (%)
are displayed on the screen until the transfer is complete.
If you want to eject the USB memory during transfer or recording; Press the F4 button
for 5 seconds and the USB memory must be removed (within 5 seconds) before the
icon on the screen disappears. If the USB stick is not removed during this time, the
transfer will resume from where it left off.
The device can store up to (Record time x 2) daily memos in its memory.Not:

Termékspecifikációk

Márka: Emko
Kategória: Temperatuurregelaar
Modell: CHANNEL8A-N

Szüksége van segítségre?

Ha segítségre van szüksége Emko CHANNEL8A-N, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek