G44-HDMI Quick Start Manual
Note
1. Do not fix the device to any surface which is a heat source to avoid over heating
2. Do not cover the surface or ventilation grills of the device to avoid over heating
1. Verify the package contents
Please verify the package contents against the List Below
1. G44-HDMI Controller
x1
5. Network Cable
x1
2. Power Cable
x1
6. Remote Control
x1
3. Quick Start Manual
x1
7. 5-pin Phoenix Connector
x4
4. Ground Wire
x1
8. 3-pin Phoenix Connector
X4
2. Set up the G44-HDMI
I. Connect the power cable to the unit and power it up
II. Connect the outputs to the screens of the video wall
III. Connect all the video sources to the inputs of the devices
Note: G44H remembers the settings used on the device before powering off. The default setting for the new
unit is video wall with across the 4 screens. All outputs are set at resolution of 1920 x 1080@60. 2x2 input 1
3. Run the software on control PC
Users can run the G H.exe software directly without installation. Software can be download from the 44 ed
SEADA website ( ). Double click the G H software to get started. https://seada.co.uk/downloads 44
4. Connect through Serial Port
Connect the G -H with a serial cable to the control PC (cable not included in the package) 44 DMI
If the software was connected via UART (RS232) last time,
software will connect to the G -H automatically via 44 DMI
RS232. If it was used at Network last time, a ‘Network
Timeout’ error message will be shown on screen and users need to set up as below for RS232 connection in
the software
Choose ‘ ’ instead of ‘UART Network
Select the from th dropdown menu COM port e Port
Press button to connect ‘Disconnected
5. Connect through Network
The default IP address for G -HDMI controller is Users need to change the IP address of the 44 192.168.0.247,
control PC to IP address and the same network segment as the G -H in static 44 DMI at TCP/IPv4 Ethernet
Properties
IP address: any address between and except the address which has been taken 192.168.0.2 192.168.0.254
by the G -H 44 DMI
Subnet mask: Default Gateway: 255.255.255.0, 192.168.0.1
Connect the G44-H with a CAT cable to the control PC (cable included in the package) DMI

Termékspecifikációk

Márka: SEADA
Kategória: Processor
Modell: G44-HDMI

Szüksége van segítségre?

Ha segítségre van szüksége SEADA G44-HDMI, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Processor SEADA

SEADA

SEADA SW2016 Útmutató

30 Augusztus 2024
SEADA

SEADA SWP02 Útmutató

30 Augusztus 2024
SEADA

SEADA SW2036 Útmutató

30 Augusztus 2024
SEADA

SEADA SW8004 Útmutató

30 Augusztus 2024
SEADA

SEADA SWP04 Útmutató

30 Augusztus 2024
SEADA

SEADA G44 Útmutató

30 Augusztus 2024
SEADA

SEADA SW4018 Útmutató

30 Augusztus 2024
SEADA

SEADA GM9 Útmutató

30 Augusztus 2024
SEADA

SEADA G4K Pro Útmutató

30 Augusztus 2024
SEADA

SEADA G44-HDMI Útmutató

30 Augusztus 2024

Útmutatók Processor

Legújabb útmutatók Processor