020323-36 FP25 LE 100003890
INSTALLATION
AND OPERATING
INSTRUCTIONS
SAFETY NOTICE
If this Fireplace is not properly installed,
a house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
MODEL:
FP25 LE,
FP25AR LE
SERIAL #
Meets the U.S.Environmental Protection
Agency's 2020 Particulate Emission Standards
for Cord Wood
Visit www.pacificenergy.net for the most recent version of this manual
TESTED and LISTED to;
CAN/ULC S610 AND UL127
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacic Energy, FP25LE/FP25 AR LE wood burning Fireplace.
SAFETY NOTICE: If this heater is not properly installed, a house re may result. For your safety, follow the installation
instructions. Contact local building or re ofcials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
Contents
Table of Contents 2 ............................................................
Rating Label 3 ....................................................................
Efciency and BTU Output 3 .......................................
Safety 4 ..............................................................................
Curing of the Paint Finish 5 ..........................................
Operation 6 .........................................................................
Wood Selection 6 .........................................................
DO NOT BURN THESE MATERIALS 6 .........................
How to Test Your Wood 7 .............................................
Lighting a Fire 7 ............................................................
Normal Operation 7 ......................................................
Restarting After Extended or Overnight Burns 8 .........
Over Firing 8 .................................................................
Proper Draft 8 ...............................................................
Maintenance Checks 9 .......................................................
Weekly: 9 ......................................................................
Monthly 9 .........................................................................
When Cleaning the Chimney System: 9 .......................
Maintenance 10 ..................................................................
Disposal of Ashes 10 ...................................................
Door Glass/Gaskets 11 ................................................
Blowers: 11 ..................................................................
Bafe: 11 ......................................................................
Bafe Removal: 12 .......................................................
Secondary Air Box Cleaning 12 ...................................
Blower Replacement 13 .....................................................
Fireplace Installation 14 ......................................................
Locating your Fireplace 14 ...........................................
Mobile Home Installation notes: 14 .............................
Crate Removal 14 ........................................................
Dimensions 15 ....................................................................
Fireplace Clearances and Dimensions 15 ....................
Minimum Framing Dimensions 16 ......................................
Framing Kit Installation 17 ..................................................
Assembly 17 .................................................................
Installing the unit into the chase 17 .............................
Chimney Installation 18 ......................................................
Offset Chimney: 19 .....................................................
Masonry Chimney: 20 ..................................................
Combustion Air 21 ..............................................................
Installation: 21 ..............................................................
Convection Blower Wiring 22 .............................................
Ember Protection 23 ..........................................................
Safety Strip 23 .............................................................
Ember Protector 23 ......................................................
Option: Remote Heat Duct Kit Installation 24 ....................
HEAT DUCT Replacement Parts 25 ...................................
Ducting Options 26 ............................................................
Duct Installation 27 ......................................................
Remote Heat Kit Wiring 29 .................................................
Finshing The Chase 30 .......................................................
Mantel and Finishing Clearances 31 ..................................
Mantel Clearances and Dimensions 31 .......................
Firebrick Installation Instructions 32 ...................................
Rating Label Location & Access 33 .....................................
Troubleshooting 34 .............................................................
Parts Diagram 35 ..................................................................
Table of Contents
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
WARNING: this product can expose you to chemicals
including ceramic bers, which are known to the state of
California to cause cancer,and to carbon monoxide, which
is known to the state of California to cause birth defects or
other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE
PRODUCTS
2FP25 LE 020323-36
100003890
EPA Certied Emissions 1.4 grams per hour
LHV Tested Efciency 1 72%
HHV Tested Efciency 2 67%
EPA BTU Output 3 11,000 to 51,500 btu/hr
Peak BTU/Hr Output 4
Maximum Wood Length 17 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
Efficiency and BTU Output
This heater meets the U.S. Environmental Protection Agency's 2020 Cord wood emission limits for wood
heaters sold after May 15, 2020 Tested to ASTM 3053.
Under specic test conditions this heater has been shown to deliver heat at rates ranging from
11,000 to
51,500Btu/hr. Emissions testing was performed by PFS-TECO Inc.
For instructions on locating and accessing the Rating label, see page 33.
Rating Label
CLEARANCES TO SIDE AND BACK STANDOFFS/ DÉGAGEMENTS 0 in. / 0 mm
C. CORNER TO SIDEWALL/ COIN AU MUR LAT. 3.1 in. / 79mm
D. FRAMING OPENING/ OVERTURE DE CADRAGE 56 in./1.42m
E. CEILING TO UNIT/ DU PLAFOND AU FOYER 38-3/4 in. / 986mm
NON-COMBUSTIBLES ONLY IN THE SPACE ABOVE UNIT TO CEILING, NOT INCLUDING
APPROVED FRAMING / NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À PLAFOND
F. BASE OF UNIT TO MANTEL/ BASE DE L’UNITÉ AU MANTEAU
G. EMBER PROTECTION FROM FRONT OF UNIT/ PROTECTEUR de PLANCHER À
L’AVANT DU FOYER 18 in. / 457 mm
H. EMBER PROTECTION TO SIDE OF UNIT/ PROTECTEUR de PLANCHER AU CÔTÉ
DU FOYER 8 in./203 mm
IN USA: (Type 1 fl oor protector - approved to UL1618)Equal to Minimum 20GA steel
DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE IQUETTE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES
SN-
100003892 200320
MANTEL HEIGHT MUST BE MEASURED FROM THE BASE OF THE UNIT AS FOLLOWS:
48 1/8 in.(1.22m) FOR ALL MANTEL DEPTHS FROM 2”(51mm) TO 12”(305mm).///
LA HAUTEUR DU MANTEAU, MESURÉE DE LA BASE DE L’APPAREIL, DOIT ÊTRE DE 48-1/8po (1,22 m)
POUR LES MANTEAUX AYANT UNE PROFONDEUR DE 2 po (51 mm) À 12 po (305 mm).
***
***
MODEL/ MODÈLE: FP25 LE FP25AR LE
LISTED FACTORY BUILT FIREPLACE, also for use in Mobile Home.
CERTIFIED TO / CERTIFIÉ POUR:
ULC S610-M87 AND UL 127-2011 for CANADA AND U.S.A.
ETL#4001507
Refer to Intertek’s Directory of Building Products for detailed information
•
•
•
•
•
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
- CHEMINÉE HOMOLOGUÉE ULC-S-629,
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES, CONFORMÉMENT AUX IN-
STRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS
D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.
• NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
• NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR LE FONC-
TIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC
L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR RESULTAT L’OPERATION
DANGEREUSE DE CECI ET AUTRES APPAREILS.
• VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
• REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. • LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.1AMP
• CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE FEU OU BLES-
SURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE.
• UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.
• CE FOYER PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉFABRIQUÉE. UTILISER DU BOIS SOLIDE SEULEMENT.
• POUR COMBUSTIBLE SOLIDE SEULEMENT.
• COMPOSANTS OPTIONNELS: KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no WODC.RHKA).
• UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.
MANUFACTURED BY/ FABRIQUÉ PAR :
PACIFIC ENERGY FIREPLACE PRODUCTS
LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
MADE IN CANADA
/ FABRIQUÉ AU CANADA
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certifi ed to comply with 2020 particulate
emission standards,
using Cordwood.
Tested to ASTM 3053 1.4g/hr.
DATE OF MANUFACTURE
•
•
•
•
•
ALSO FOR USE IN MANUFACTURED HOMES WITH SOLID WOOD FUEL ONLY
• INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE
• AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE WITH THE INSTALLA-
TION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR NORMAL
FIREPLACE OPERATION AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE. INADEQUATE
AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION OF THIS AND OTHER APPLIANCES.
• CHIMNEY SYSTEM MUST BE LISTED TO:
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA
ULC S-629 IN CANADA / UL-103 HT IN USA -
-
-
-
ULC S-629 IN CANADA / UL-103 HT IN USA - SEE LOCAL BUILDING CODE AND MANUFACTURER'S
INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• OPTIONAL COMPONENTS: REMOTE HEAT KIT PART# WODC.RHKA.
• USE SOLID WOOD FUEL ONLY. OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS.
• DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
• THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO FIREPLACE.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
• - CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING
INSTRUCTIONS IN THE OWNER’S MANUAL.
C
D
E
G
F
CAN.
U.S.A.
H
H
3
FP25 LE 020323-36 100003890
Termékspecifikációk
Márka: | Pacific Energy |
Kategória: | Fűtő |
Modell: | FP25 Arch LE |
Szüksége van segítségre?
Ha segítségre van szüksége Pacific Energy FP25 Arch LE, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Fűtő Pacific Energy
19 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
Útmutatók Fűtő
- Fűtő Mestic
- Fűtő Dometic
- Fűtő Electrolux
- Fűtő Nedis
- Fűtő Milwaukee
- Fűtő Parkside
- Fűtő Candy
- Fűtő Philips
- Fűtő Gorenje
- Fűtő Adler
- Fűtő Princess
- Fűtő SilverCrest
- Fűtő Bosch
- Fűtő NewAir
- Fűtő MPM
- Fűtő AEG
- Fűtő Emerio
- Fűtő Einhell
- Fűtő Bartscher
- Fűtő Maxwell
- Fűtő Hyundai
- Fűtő Scarlett
- Fűtő Tefal
- Fűtő HQ
- Fűtő Emos
- Fűtő Corbero
- Fűtő Camry
- Fűtő Xiaomi
- Fűtő Danby
- Fűtő DeLonghi
- Fűtő Clean Air Optima
- Fűtő Heinner
- Fűtő Infiniton
- Fűtő Sunbeam
- Fűtő Beurer
- Fűtő Trumatic
- Fűtő Wilfa
- Fűtő Klarstein
- Fűtő VOX
- Fűtő Scheppach
- Fűtő Vivax
- Fűtő Conceptronic
- Fűtő Thomson
- Fűtő Fagor
- Fűtő Unold
- Fűtő SHX
- Fűtő Brentwood
- Fűtő Ardes
- Fűtő Cuisinart
- Fűtő Eden
- Fűtő Eurolite
- Fűtő Jocel
- Fűtő Duronic
- Fűtő Bimar
- Fűtő Clatronic
- Fűtő Bomann
- Fűtő Bauknecht
- Fűtő Dyson
- Fűtő Ambiano
- Fűtő Cecotec
- Fűtő Sencor
- Fűtő Pelgrim
- Fűtő Qlima
- Fűtő Baxi
- Fűtő Innoliving
- Fűtő Rowenta
- Fűtő Güde
- Fűtő Eta
- Fűtő Izzy
- Fűtő Nevir
- Fűtő JANDY
- Fűtő GoldAir
- Fűtő Domo
- Fűtő Russell Hobbs
- Fűtő Caso
- Fűtő Solac
- Fűtő Carson
- Fűtő Create
- Fűtő Crane
- Fűtő Mora
- Fűtő Black & Decker
- Fűtő Enders
- Fűtő Global
- Fűtő Livington
- Fűtő Orbegozo
- Fűtő Lenoxx
- Fűtő Livoo
- Fűtő Eberle
- Fűtő ARGO
- Fűtő Guzzanti
- Fűtő Concept
- Fűtő DCS
- Fűtő DEDRA
- Fűtő SVAN
- Fűtő SPC
- Fűtő Nobo
- Fűtő TriStar
- Fűtő Suntec
- Fűtő BaseTech
- Fűtő Zodiac
- Fűtő RYOBI
- Fűtő Fantini Cosmi
- Fűtő Chauvet
- Fűtő Midea
- Fűtő Steba
- Fűtő Trisa
- Fűtő Heller
- Fűtő Kogan
- Fűtő Honeywell
- Fűtő Broan
- Fűtő Mesko
- Fűtő Velleman
- Fűtő Dimplex
- Fűtő Master
- Fűtő Kenmore
- Fűtő Thermex
- Fűtő Hayward
- Fűtő DCG
- Fűtő Tesy
- Fűtő Melissa
- Fűtő Trotec
- Fűtő Blaupunkt
- Fűtő AstralPool
- Fűtő Korona
- Fűtő Stadler Form
- Fűtő Taurus
- Fűtő Signature
- Fűtő Olympia
- Fűtő Logik
- Fűtő NEO Tools
- Fűtő AFK
- Fűtő Everdure
- Fűtő DeWalt
- Fűtő Kalorik
- Fűtő Waldbeck
- Fűtő Alpina
- Fűtő Philco
- Fűtő Brandson
- Fűtő ECG
- Fűtő Stanley
- Fűtő Rotel
- Fűtő Vemer
- Fűtő Vornado
- Fűtő Ufesa
- Fűtő Vonroc
- Fűtő Rinnai
- Fűtő Cotech
- Fűtő Argoclima
- Fűtő Ausclimate
- Fűtő WAGAN
- Fűtő Beper
- Fűtő Bestron
- Fűtő Orion
- Fűtő Soler & Palau
- Fűtő SereneLife
- Fűtő Ravanson
- Fűtő Teesa
- Fűtő Becken
- Fűtő OneConcept
- Fűtő Haeger
- Fűtő Olimpia Splendid
- Fűtő Orava
- Fűtő Eurom
- Fűtő Mill
- Fűtő Maestro
- Fűtő Eureka
- Fűtő Sogo
- Fűtő Sonnenkönig
- Fűtő Fluval
- Fűtő Lifesmart
- Fűtő Flama
- Fűtő Tectro
- Fűtő Fenix
- Fűtő Zibro
- Fűtő Quigg
- Fűtő AKO
- Fűtő Invicta
- Fűtő Haverland
- Fűtő Calor
- Fűtő Sinbo
- Fűtő Jata
- Fűtő Swan
- Fűtő Anslut
- Fűtő Sun Joe
- Fűtő EWT
- Fűtő Mellerware
- Fűtő Nestor Martin
- Fűtő Termozeta
- Fűtő Eldom
- Fűtő Cresta
- Fűtő Defy
- Fűtő Bionaire
- Fűtő Maginon
- Fűtő Otsein-Hoover
- Fűtő Profile
- Fűtő Ferroli
- Fűtő Real Flame
- Fűtő Evolar
- Fűtő Perel
- Fűtő Zibro Kamin
- Fűtő Proline
- Fűtő Royal Sovereign
- Fűtő King
- Fűtő Malmbergs
- Fűtő Piazzetta
- Fűtő Heylo
- Fűtő Kent
- Fűtő Arnold Rak
- Fűtő CasaFan
- Fűtő Wamsler
- Fűtő Duux
- Fűtő Imetec
- Fűtő Alpatec
- Fűtő Blaze
- Fűtő Sygonix
- Fűtő Primo
- Fűtő Creda
- Fűtő SuperFish
- Fűtő Plieger
- Fűtő Reer
- Fűtő Zehnder
- Fűtő Napoleon
- Fűtő Essentiel B
- Fűtő Prime3
- Fűtő Blumfeldt
- Fűtő CaterChef
- Fűtő Kambrook
- Fűtő Zephir
- Fűtő Harvia
- Fűtő Brixton
- Fűtő Superior
- Fűtő Kunft
- Fűtő La Nordica
- Fűtő Jotul
- Fűtő Vasco
- Fűtő Noveen
- Fűtő Nectre
- Fűtő Cadel
- Fűtő Grunkel
- Fűtő PAX
- Fűtő Jaga
- Fűtő Lervia
- Fűtő Masport
- Fűtő REMKO
- Fűtő Extraflame
- Fűtő Lynx
- Fűtő Just Fire
- Fűtő Optimum
- Fűtő Hartig And Helling
- Fűtő Gutfels
- Fűtő Westfalia
- Fűtő TAIDEN
- Fűtő Veito
- Fűtő Ecoteck
- Fűtő Etherma
- Fűtő Nordic Fire
- Fűtő Haas+Sohn
- Fűtő Eurotronic
- Fűtő Wanders
- Fűtő Grandhall
- Fűtő Emga
- Fűtő Heatstrip
- Fűtő Escea
- Fűtő Braemar
- Fűtő Bromic Heating
- Fűtő Martec
- Fűtő Jindara
- Fűtő Neo
- Fűtő SPT
- Fűtő Hatco
- Fűtő SunRed
- Fűtő Aerian
- Fűtő IXL
- Fűtő XPower
- Fűtő True North
- Fűtő WestBend
- Fűtő Hortus
- Fűtő Prem-i-air
- Fűtő Quadra-Fire
- Fűtő Mr. Heater
- Fűtő Stenda
- Fűtő VIESTA
- Fűtő Apricus
- Fűtő Heatsome
- Fűtő Brivis
- Fűtő Hubbell
- Fűtő HeatStar
- Fűtő Dri Eaz
- Fűtő Regency
- Fűtő Burley
- Fűtő Monzana
- Fűtő Invroheat
- Fűtő Kaden
- Fűtő Jarden
- Fűtő Noirot
- Fűtő Ouellet
- Fűtő AccuLux
- Fűtő Gossmann
- Fűtő Wulfe
- Fűtő Duro Pro
- Fűtő Herschel
- Fűtő Casaya
- Fűtő HyCell
- Fűtő TURBRO
- Fűtő Radialight
- Fűtő Sunheat
- Fűtő Heidenfeld
- Fűtő Hcalory
- Fűtő Rowi
- Fűtő Neopower
- Fűtő Arlec
- Fűtő Guardian
- Fűtő Big Ass Fans
- Fűtő Pureheat
- Fűtő EvoHeat
- Fűtő Bromic
- Fűtő MSW
- Fűtő Solamagic
- Fűtő Contura
- Fűtő Mirpol
- Fűtő Alkari
- Fűtő Longvie
- Fűtő Blue Rhino
- Fűtő Rheem
- Fűtő Gasmate
- Fűtő Ionmax
- Fűtő Airo
- Fűtő Mission Air
- Fűtő Omega Altise
- Fűtő Scandia
- Fűtő Vasner
- Fűtő Fire Sense
- Fűtő InfraNomic
- Fűtő Heat Storm
- Fűtő Excelair
- Fűtő Heatscope
- Fűtő Heat1
- Fűtő Thermotec
- Fűtő Perfect Aire
- Fűtő AustWood
- Fűtő Uniprodo
- Fűtő Infratech
- Fűtő Yamazen
- Fűtő TANSUN
- Fűtő Universal Blue
Legújabb útmutatók Fűtő
22 December 2024
22 December 2024
22 December 2024
22 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
20 December 2024