Használati útmutató Pacific Energy Espirit

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Pacific Energy Espirit (44 oldal) a Fűtő kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/44
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
This appliance is suitable for installation in a
bedroom or bed sitting room.
ESPRIT
INSTALLATION
AND OPERATING
INSTRUCTIONS
Visit www. pacificenergy.net for the most recent version of this manual
MODEL: ESPR.BODYB
ESPRIT ZERO CLEARANCE
FIREPLACE
WARNING: If the information in these instruc-
tions is not followed exactly a fire or explosion
may result causing property damage, personal
injury or death.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical Switch.
Do not use any phone in your building.
Immediately call your gas supplier
from a neighbours phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier
call the fire department.
Do not store or use gasoline or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appli-
ance is not convertible for use with other
gases unless a certified kit is used.
SERIAL #
ESPRIT130323-44 100000326
Table of Contents
Important Note for the
Commonwealth of Massachusetts 3 .........................
Caution 4 ....................................................................
Safety 5 ......................................................................
First Fire 6 ..................................................................
Remote Control Operation 7 ......................................
System Description 7 ...............................................
Transmitter (Remote Control with LCD Display) 7 ....
IFC Module 8 ...........................................................
Operating Procedure 8 ............................................
Initializing the System for the rst time 8 ................
Temperature indication Display 9 ............................
Turn on the Fireplace 9 ............................................
Turn off the Fireplace 9 ............................................
Manual Bypass of the Remote System 9 ................
Key Lock............................................................... 9
Remote Flame Control 10 .......................................
ROOM THERMOSTAT (Transmitter Operation) 10 ..
Smart Thermostat (Transmitter Operation) 10 ........
Comfort Fan Speed Control 11 ................................
Continuous Pilot/Intermittent Pilot
(CPI/IPI) selection 11 ................................................
Low battery detection 12 ........................................
Transmitter 12 .........................................................
Receiver...............................................................12
Key Lock..............................................................12
Warnings and Cautions 12 .........................................
Maintenance 13 .........................................................
Glass Door 13 ..........................................................
Annual Inspection 13 ..............................................
Periodically 13 .........................................................
Lighting Instructions 14 ..............................................
Fireplace Dimensions 15 ............................................
Clearances to Combustibles 17 .................................
Minimum Clearance to Combustible Materials 17 ...
Locating the Fireplace 18 ..........................................
Surround Installation Instructions 19 .........................
Venting 21 ...................................................................
Vent Terminal Minimum Clearances 22 ......................
Venting Components 23 ............................................
Plumbing and Electrical 24 .........................................
Gas connection 24 ...................................................
Electrical connection 24 ...........................................
Gas Supply 25 ............................................................
Gas Pressure Check 25 ..............................................
Gas pressure requirements 25 ................................
Gas Pressure Testing Procedure 26 ..........................
Propane Conversion 27 ..............................................
Door Installation/Removal 28 ....................................
Fan Installation / Removal 28 ....................................
Fan removal before replace installation 29 ............
Panel Installation / Removal 29 .................................
Glass Burner Kit Installation / Removal 30 ................
Log Set Installation / Removal 34 ..............................
Intake Air Damper Installation 38 .............................
Replacement Parts 39 ...............................................
Wiring Diagram 40 .....................................................
Rating Label 41 ..........................................................
WARNING: This product
can expose you to chemicals
including ceramic bers,
which are known to the State
of California to cause cancer, and carbon
monoxide, which is known to the State of
California to cause birth defects or other
reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
This warning is applicable to all
Pacific Energy Fireplace Products
2
100000326 ESPRIT130323-44
Important Note for the Commonwealth of Massachusetts
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet
above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the
installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the oor
level where the gas equipment is to be installed, in addition, the installing plumber or gas tter shall observe that a battery operated or hard-wired
carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal
vented gas fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualied licensed professionals for the
installation of hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide
detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty
(30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide
detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall
read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless,
upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)
(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented in the most current edition of NFPA 54 as adopted by the
Board; and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure
used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided
by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identies “special venting systems, the
following requirements shall be satised by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed
installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts
lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
3
130323-44 100000326ESPRIT

Termékspecifikációk

Márka: Pacific Energy
Kategória: Fűtő
Modell: Espirit

Szüksége van segítségre?

Ha segítségre van szüksége Pacific Energy Espirit, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Fűtő Pacific Energy

Útmutatók Fűtő

Legújabb útmutatók Fűtő