Használati útmutató Fluke Networks TS 100 Cable Fault Finder

Fluke Networks TS 100 Cable Fault Finder

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Fluke Networks TS 100 Cable Fault Finder (20 oldal) a kategóriában. Ezt az útmutatót 5 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/20
TS®100 Cable Fault Finder
PN 2825486 (Metric)
January 2007 Rev. 1 2/09
©2007, 2009 Fluke Corporation. All rights reserved. Printed in China.
All product names are trademarks of their respective companies.
Users Guide
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke Networks product is warranted to be free from defects in material and workmanship under
normal use and service. The warranty period for the mainframe is 18 months and begins on the date of
purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated.
Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The
warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller,
and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered,
neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke
Networks warrants that software will operate substantially in accordance with its functional specifications
for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant
that software will be error free or operate without interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user
customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks.
Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet
or Buyer has paid the applicable international price. Fluke Networks reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one country is submitted for repair
in another country.
Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price,
free of charge repair, or replacement of a defective product which is returned to a Fluke Networks
authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the difficulty,
postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit.
Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination).
If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident
or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke
Networks will provide an estimate of repair costs and obtain authorization before commencing the work.
Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be
billed for the repair and return transportation charges (FOB Shipping point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any
other provision.
4/04-18
Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA
i
Table of Contents
Title Page
Introduction ....................................................................................................................................................1
Registration .....................................................................................................................................................1
Contacting Fluke Networks ............................................................................................................................1
Safety Information ..........................................................................................................................................2
Design Features ...............................................................................................................................................2
Physical Characteristics ...................................................................................................................................3
Line Cords and Accessories .............................................................................................................................3
Operation ........................................................................................................................................................3
Installing Batteries ...................................................................................................................................4
Turning on the Tester ..............................................................................................................................4
Automatic Power-Down ..........................................................................................................................4
Testing Cables ..........................................................................................................................................4
PowerTone™ Positive Identification System ..........................................................................................4
Velocity of Propagation (VOP) ................................................................................................................6
In Case of Unstable or Unusual Readings ...............................................................................................6
Applications .....................................................................................................................................................7
Multi-Wire Environment .........................................................................................................................7
Conduit .....................................................................................................................................................7
Testing a Wire Pair in a Conduit ......................................................................................................7
Testing a Single Wire in a Conduit ..................................................................................................7
Inventory Management ...........................................................................................................................8
Time Domain Reflectometry (TDR) Technology ..........................................................................................10
VOP Variations .......................................................................................................................................11
Maximum Length ...................................................................................................................................12
Frequently Asked Questions .........................................................................................................................12
If Something Seems Wrong with the Tester ...............................................................................................14
Maintenance .................................................................................................................................................14
Specifications .................................................................................................................................................15

Termékspecifikációk

Márka: Fluke Networks
Kategória:
Modell: TS 100 Cable Fault Finder

Szüksége van segítségre?

Ha segítségre van szüksége Fluke Networks TS 100 Cable Fault Finder, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Fluke Networks

Útmutatók

Legújabb útmutatók