INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
700
400
196
85 115 200
330
DOMIcondens F
DOMIcondens F
DOMIcondens F
DOMIcondens FDOMIcondens F
2GB cod. 3540S921 - 11/2009 (Rev. 00)
GB
1. GENERAL INSTRUCTIONS
• Carefully read the instructions contained in this instruction booklet.
• After boiler installation, inform the user regarding its operation and give him this manual, which is an integral
and essential part of the product and must be kept with care for future reference.
• Installation and maintenance must be carried out by professionally qualified personnel, according to current
regulations and the manufacturer's instructions. Do not carry out any operation on the sealed control parts.
• Incorrect installation or inadequate maintenance can result in damage or injury. The Manufacturer declines
any liability for damage due to errors in installation and use or failure to follow the instructions.
• Before carrying out any cleaning or maintenance operation, disconnect the unit from the power supply using
the system switch and/or the special cut-off devices.
• In case of a fault and/or poor operation, deactivate the unit and do not attempt to repair it or directly intervene.
Contact professionally qualified personnel. Repair/replacement of the products must only be carried out by
professionally qualified using original spare parts. Failure to comply with the above could affect the safety of
the unit.
• This unit must only be used for its intended purpose. Any other use is considered improper and therefore
dangerous.
• The packing materials are potentially hazardous and must not be left within the reach of children.
• The images given in this manual are a simplified representation of the product. In this representation there
may be slight and insignificant differences with respect to the product supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
DOMIcondens F is a high-efficiency sealed chamber condensing heat generator for
heating and hot water production running on natural gas or LPG, and equipped with a
microprocessor control system.
2.2 Control panel
fig. 1 - Control panel
Key
1 = Domestic hot water temperature setting
3 = Heating system temperature setting
5 = Display
6 = Summer/Winter mode selection - Reset button
7 = Unit On/Off - Eco/Comfort mode selection button
9 = DHW mode
10 = Summer mode
11 = Temperature or faults
12 = Eco (Economy) mode
13 = Heating
15 = Burner On and actual power
16 = Clock prearrangement
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
Domestic hot water (DHW)
A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
2.3 Lighting and turning off
Connection to the power supply
• During the first 5 seconds the display shows the card software version.
• Open the gas cock ahead of the boiler.
• The boiler is now ready to operate automatically whenever hot water is drawn or in
case of a room thermostat demand.
Boiler lighting and shutdown
Press the on/off button (detail 7 - fig. 1) for 5 seconds.
fig. 2 - Turning the boiler off
When the boiler is turned off, the PCB is still powered. Domestic hot water and heating
are disabled. The antifreeze system remains activated. To relight the boiler, press the
on/off button (detail 7 fig. 1) again for 5 seconds.
fig. 3
The boiler will be immediately ready to operate whenever domestic hot water is drawn
or in case of a room thermostat demand.
BThe antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, DHW circuit and system; or
drain just the DHW circuit and add a suitable antifreeze to the heating system,
complying with that prescribed in sec. 3.3.
2.4 Adjustments
Summer/Winter Switchover
Press the summer/winter button (detail 6 - fig. 1) for 2 seconds.
The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate the Summer mode, press the button (detail 6 - fig. 1)summer/winter
again for 2 seconds.
Heating temperature setting
Use the heating buttons (detail 3 - fig. 1) to adjust the temperature from a min. of 30°C
to a max. of 85°C; it is advisable not to operate the boiler below 45°C.
fig. 4
Hot water temperature adjustment
Use the DHW buttons (detail 1 - fig. 1) to adjust the temperature from a min. of 40°C to
a max. of 55°C.
fig. 5
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms. If the room ther-
mostat is not installed, the boiler will keep the system at the set system delivery setpoint
temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the required temperature in the rooms. The boiler will
adjust the system water according to the required room temperature. For operation with
remote timer control, please refer to the relevant instruction manual.
ECO/COMFORT selection
The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, therefore ensuring immediate availability of hot water
on opening the tap, without waiting times.
The device can be deactivated by the user (ECO mode) by pressing the eco/comfort
button (detail 7 - fig. 1) with the boiler in standby mode. In ECO mode the display acti-
vates the ECO symbol (detail 12 - fig. 1). To activate COMFORT mode, press the eco/
comfort button (detail 7 - fig. 1) again.
Adjustments from Remote Timer Control
AIf the Remote Timer Control (optional) is connected to the boiler, the above ad-
justments are managed according to that given in table 1.
Table. 1
Water system pressure regulation
The filling pressure read on the boiler water gauge with the system cold must be approx
1.0 bar. If the system pressure falls to values below minimum, the boiler stops and fault
F37 is displayed.
16
eco
comfort
reset
9 15
13
12
11
10
1
3 6
75
Heating temperature setting
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
Hot water temperature adjustment
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
Summer/Winter Switchover
Summer mode has priority over a possible Remote Timer Control heat-
ing demand.
Eco/Comfort selection
Adjustment can only be made from the boiler control panel.
DOMIcondens
DOMIcondens
DOMIcondens
DOMIcondensDOMIcondens F
F
F
F F
3
GB
cod. 3540S921 - 11/2009 (Rev. 00)
3. INSTALLATION
3.1 General Instructions
BThis unit must only be used for its intended purpose. This unit is designed to
heat water to a temperature below boiling point and must be connected to a
heating system and/or a water supply system for domestic use, compatible with
its performance, characteristics and its heating capacity. Any other use is
deemed improper.
BOILER INSTALLATION MUST ONLY BE CARRIED OUT BY QUALIFIED PERSON-
NEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL
MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF THE
TECHNICAL STANDARDS (BS), ANY LOCAL REGULATIONS AND THE RULES OF
PROPER WORKMANSHIP.
Incorrect installation can cause damage or injury for which the manufacturer declines
any responsibility.
Installation of this unit must be carried out in strict compliance with the present
instructions and the following regulations applicable in Great Britain.
Gas Safety Regulations (Installations & Use).
Local Building Regulations..
The Building Regulations (Part L).
The Buildings Standards (Scotland - Consolidated) Regulations. British Standards
Codes of Practice (BSI):
Model Water By-Laws
For Northern Ireland, observe the current applicable regulations.
Safe handling of materials
Pay attention when handling the boiler insulation panels because the material they are
made of could irritate the skin. No part of the boiler contains asbestos, mercury or CFC's.
Advice for transport and handling
For lifting and transport always take suitable safety precautions: keep your back straight,
bend knees, do not turn your body, move feet, avoid bending forward or sideways and
keep the load as close as possible to your body.
If possible, use a trolley or other suitable means to carry the boiler.
Grip the boiler firmly and, before lifting it, try and find the point where the load is concen-
trated in order to establish the centre of gravity and suitably reposition yourself.
3.2 Place of installation
The combustion circuit is sealed with respect to the place of installation room, therefore
the unit can be installed in any room. However, the place of installation must be ade-
quately ventilated to prevent the creation of dangerous conditions in case of even small
gas leaks. This safety regulation is laid down by EEC Directive no. 90/396 for all gas
units, including those with sealed chamber.
The unit is suitable for operation in a partially protected place in conformity with EN 297/
A6, with minimum temperature -5°C. If equipped with the special antifreeze kit, it can be
used with minimum temperatures to -15°C. The boiler must be installed is a protected
place, e.g. under the slope of a roof, inside a balcony or in a sheltered recess.
The place of installation must in any case be free of dust, flammable materials or objects
or corrosive gases.
The boiler is arranged for wall mounting and comes standard with a hooking bracket. The
wall fixing must ensure a stable and effective support for the generator.
AIf the unit is enclosed in a cabinet or mounted alongside, a space must be pro-
vided for removing the casing and for normal maintenance operations
3.3 Plumbing connections
Important
The heating capacity of the unit must be previously established by calculating the build-
ing's heat requirement according to the current regulations. To ensure proper operation
and long boiler life, the plumbing system must be adequately sized and complete with all
the necessary accessories, including a room thermostat, a thermostattable valve (TRV)
etc. The system delivery and return pipes must have a diameter of at least 22 mm for the
first 3 m of length from the unit.
If the system delivery and return pipes follow a path where air pockets can form in certain
places, it is advisable to install vent valves at these points. Also, type "A" drain cocks
must be installed at the lowest points in the system to allow complete emptying.
BAn automatic bypass with flow rate of at least 6 l/min. must be installed (con-
nected as far away as possible from the boiler) if radiators with thermostatic
valves have been connected.
fig. 6 - Automatic bypass connection
The temperature drop between the delivery manifold and the return to the boiler should
not exceed 20°C.
BDo not use the water system pipes to earth electrical appliances.
Before installation, carefully wash all the pipes of the heating system to remove any re-
siduals or impurities that could affect proper operation of the unit (as required by BS 7593
Building regs Doc L).
Carry out the connections to the unit as indicated in fig. 7.
fig. 7 - Water connections
Shutoff valve kit
Make sure to install the shutoff valves (supplied) between the boiler and the heating sys-
tem, allowing the boiler to be isolated from the system if necessary.
BThe safety valve outlet must be connected to a copper pipe of 15 mm diameter
with continuous fall from the boiler to run off the system water in case of over-
pressure in the heating circuit. Otherwise, if the discharge valve cuts in and
floods the room, the boiler manufacturer cannot be held liable. The drain must
be run to the outside of the building to avoid the risk of damage or injury due to
the hot water in case of overpressure in the system.
Make the boiler connection in such a way that its internal pipes are free of stress. If a
non-return valve is installed also on the DHW circuit (if provided for), it is necessary to
install a safety valve between the boiler and the circuit (with the non-return valve at least
3 m from the boiler) or an expansion tank for domestic use.
For installation, follow the instructions contained in the kit.
B.S.
5440 Detail 1 Flues
B.S.
5440 Detail 2 Air supply and ventilation
B.S.
5449 ......... Systems for hot water production with forced circulation
B.S.
6798 ......... Installation of gas-fired boilers for hot water
B.S.
6891 ......... Gas systems
B.S.
7671 ......... IEE wiring system regulations
B.S.
4814 ......... Specifications for expansion tanks
B.S.
5482 ......... LPG systems
B.S.
7593 ......... Water treatment in central heating systems for domestic hot water production
B.S.
5546 ......... Installation of systems for domestic hot water production
B.S.
5955-8 ......... Installation of plastic pipes
Gas
Hot water
Additional expansion
vessel C.H. (if required)
Filling
point C.H.
Automatic
Bypass
Cold water mains
39 60 60 86 95 60
1 3
6
52 4
Termékspecifikációk
Márka: | Ferroli |
Kategória: | Kazánok és kazánok |
Modell: | DOMIcondens F 24 |
Szüksége van segítségre?
Ha segítségre van szüksége Ferroli DOMIcondens F 24, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Kazánok és kazánok Ferroli
4 Január 2025
13 Augusztus 2024
8 Augusztus 2024
6 Augusztus 2024
6 Augusztus 2024
5 Augusztus 2024
28 Július 2024
22 Július 2024
Útmutatók Kazánok és kazánok
- Kazánok és kazánok Beko
- Kazánok és kazánok Dometic
- Kazánok és kazánok Electrolux
- Kazánok és kazánok Whirlpool
- Kazánok és kazánok Ariston Thermo
- Kazánok és kazánok Philips
- Kazánok és kazánok Gorenje
- Kazánok és kazánok Bosch
- Kazánok és kazánok Panasonic
- Kazánok és kazánok AEG
- Kazánok és kazánok Teka
- Kazánok és kazánok Hisense
- Kazánok és kazánok Siemens
- Kazánok és kazánok Corbero
- Kazánok és kazánok Camry
- Kazánok és kazánok Cointra
- Kazánok és kazánok Viessmann
- Kazánok és kazánok Infiniton
- Kazánok és kazánok VOX
- Kazánok és kazánok Fagor
- Kazánok és kazánok Jocel
- Kazánok és kazánok Hotpoint
- Kazánok és kazánok Haier
- Kazánok és kazánok Sencor
- Kazánok és kazánok Baxi
- Kazánok és kazánok CATA
- Kazánok és kazánok Hitachi
- Kazánok és kazánok Inventum
- Kazánok és kazánok Kospel
- Kazánok és kazánok Eta
- Kazánok és kazánok Atag
- Kazánok és kazánok Solac
- Kazánok és kazánok Stiebel Eltron
- Kazánok és kazánok Mora
- Kazánok és kazánok Vaillant
- Kazánok és kazánok Orbegozo
- Kazánok és kazánok GE
- Kazánok és kazánok Guzzanti
- Kazánok és kazánok Concept
- Kazánok és kazánok SVAN
- Kazánok és kazánok Rommer
- Kazánok és kazánok Atlantic
- Kazánok és kazánok SolarEdge
- Kazánok és kazánok Daikin
- Kazánok és kazánok Midea
- Kazánok és kazánok Truma
- Kazánok és kazánok Remeha
- Kazánok és kazánok Dimplex
- Kazánok és kazánok Tesy
- Kazánok és kazánok HTW
- Kazánok és kazánok Taurus
- Kazánok és kazánok Junkers
- Kazánok és kazánok Technika
- Kazánok és kazánok Quantum
- Kazánok és kazánok Rinnai
- Kazánok és kazánok Edilkamin
- Kazánok és kazánok ACV
- Kazánok és kazánok De Dietrich
- Kazánok és kazánok Arçelik
- Kazánok és kazánok AquaTech
- Kazánok és kazánok Nefit
- Kazánok és kazánok A.O. Smith
- Kazánok és kazánok Easypix
- Kazánok és kazánok Intergas
- Kazánok és kazánok Eldom
- Kazánok és kazánok Buderus
- Kazánok és kazánok Elco
- Kazánok és kazánok Masterwatt
- Kazánok és kazánok Nibe
- Kazánok és kazánok Elba
- Kazánok és kazánok Kelvinator
- Kazánok és kazánok Buffalo
- Kazánok és kazánok TTulpe
- Kazánok és kazánok Worcester
- Kazánok és kazánok Plieger
- Kazánok és kazánok Bulex
- Kazánok és kazánok AWB
- Kazánok és kazánok OSO
- Kazánok és kazánok Kunft
- Kazánok és kazánok Clage
- Kazánok és kazánok Noveen
- Kazánok és kazánok Joven
- Kazánok és kazánok Daalderop
- Kazánok és kazánok Eccotemp
- Kazánok és kazánok Biasi
- Kazánok és kazánok Morco
- Kazánok és kazánok Thermor
- Kazánok és kazánok Sentry
- Kazánok és kazánok LEMET
- Kazánok és kazánok Wesen
- Kazánok és kazánok Wagaparts
- Kazánok és kazánok IQE
- Kazánok és kazánok Khind
- Kazánok és kazánok Wahlbach
- Kazánok és kazánok LERAN
- Kazánok és kazánok Ygnis
- Kazánok és kazánok Dux
- Kazánok és kazánok Intellihot
- Kazánok és kazánok Wijas
- Kazánok és kazánok Airthereal
- Kazánok és kazánok Thermoflow
- Kazánok és kazánok IStore
- Kazánok és kazánok Apricus
- Kazánok és kazánok Aquamarin
- Kazánok és kazánok Sime
- Kazánok és kazánok Hydrotherm
- Kazánok és kazánok Amtrol
- Kazánok és kazánok Neopower
- Kazánok és kazánok Gleamous
- Kazánok és kazánok AquaMAX
- Kazánok és kazánok My-PV
- Kazánok és kazánok EvoHeat
- Kazánok és kazánok Rheem
- Kazánok és kazánok Mission Air
- Kazánok és kazánok Solahart
- Kazánok és kazánok ENEFT
- Kazánok és kazánok Imarflex
- Kazánok és kazánok MicroHeat
- Kazánok és kazánok Noritz
Legújabb útmutatók Kazánok és kazánok
5 Január 2025
5 Január 2025
5 Január 2025
5 Január 2025
5 Január 2025
5 Január 2025
4 Január 2025
4 Január 2025
3 Január 2025
3 Január 2025