Használati útmutató Dux Proflo 50S124P

Dux Kazánok és kazánok Proflo 50S124P

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Dux Proflo 50S124P (16 oldal) a Kazánok és kazánok kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/16
25L and 50L Electric Storage Water Heater
Owners Manual
Models: 25S124P, 25S136, N25S124P,
N25S136, 50S124P, 50S136,
N50S124P, N50S136
028299 Rev. C
Specications and materials may change without notice.
Effective for the above model numbers of electric storage water heaters manufactured and
sold after 1st March 2021.
For advice, repairs and service, call:
1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Installation Details
Owners Information
Warranty
Important Safety Information
Owner’s Manual – Proflo 25/50 Litre Water Heater
i028299 Rev. C
WARNING – THIS APPLIANCE
MAY DELIVER WATER AT HIGH
TEMPERATURE. REFER TO THE
PLUMBING CODE OF AUSTRALIA
(PCA), LOCAL REQUIREMENTS AND
INSTALLATION INSTRUCTIONS TO
DETERMINE IF ADDITIONAL DELIVERY
TEMPERATURE CONTROL
IS REQUIRED.
WARNING – FOR CONTINUED
SAFETY OF THIS APPLIANCE IT
MUST BE INSTALLED, OPERATED
AND MAINTAINED IN ACCORDANCE
WITH THE MANUFACTURER’S
INSTRUCTIONS.
This water heater is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the water
heater by a person responsible for their
safety.
Children should be supervised to ensure
they do not interfere with the water heater.
Ensure animals are supervised so they do
not interfere with the water heater.
DO NOT store chemicals or ammable
materials, or spray aerosols near this water
heater.
DO NOT modify this water heater.
DO NOT operate the water heater with any
panels or covers removed.
If the water heater is not used for two weeks
or more, a quantity of hydrogen (which is
highly ammable) may accumulate inside the
water heater tank.
To dissipate this gas safely it is
recommended that a hot tap be turned on
for several minutes at a sink, basin or bath,
but not a dishwasher, clothes washer or
other appliance.
During this procedure there must be no
smoking, open ame or any other electrical
appliance operating nearby. If hydrogen is
discharged through the tap it will probably
make a sound similar to air escaping.
RELIEF VALVE:
The Pressure & Temperature Relief (PTR)
Valve must be installed with the brass
reducer directly into a RP¾”(DN20) socket
marked “RELIEF VALVE”.
The PTR Valve rating is 1,000 kPa and
10 kW on 25L and 50L capacities.
The valve must not be tampered with or
removed. The water heater must not be
operated unless this valve is tted and in
working order.
The drain line from the PTR Valve must
be installed in a continuously downward
direction in a frost free environment.
The PTR Valve is to be operated regularly
to remove lime deposits and to verify it is
not blocked. The drain line tted to the PTR
Valve must be left open to the atmosphere.
DANGER – FAILURE TO OPERATE
THE PTR VALVE EASING LEVER AT
LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER
EXPLODING. CONTINUOUS LEAKAGE
OF WATER FROM THE VALVE MAY
INDICATE A PROBLEM WITH THE
WATER HEATER.
Important Safety Information
Owner’s Manual – Proflo 25/50 Litre Water Heater
ii
028299 Rev. C
The PTR Valve should be checked by
a licensed tradesperson for adequate
performance, or replaced at intervals not
exceeding 5 years, or less in areas where
local regulations apply.
It is normal for water to drip from the drain
line tted to the PTR Valve during heating
cycles.
Continuous leakage of water from the PTR
Valve may indicate a problem with the water
heater. This may be caused by excessive
water supply pressure, a faulty PTR Valve or
a faulty thermostat.
Turn off the water heater and contact Dux
After Sales and Service.
OVER-TEMPERATURE ENERGY
CUT-OUT:
The operation of the over-temperature
energy cut-out indicates a possibly
dangerous situation. Do NOT reset the
over-temperature energy cut-out until the
water heater has been serviced by a licensed
tradesperson.
ELECTRICAL SAFETY:
This water heater is designed for single
phase 230-240V a.c. supply only. The
electrical connection must comply with
Local Supply Authority Regulations and
AS/NZS 3000 (known as the Wiring
Rules). A means for disconnection must
be incorporated in the xed wiring in
accordance with the Wiring Rules.
If the power supply cord is damaged, it must
be replaced by the manufacturer, a service
agent or a similarly qualied person in order
to avoid a hazard.
Any electrical covers should be removed only
by a licensed tradesperson, and only after
the electrical supply to the water heater has
been isolated.
When the supply wiring has been
connected, ensure the wires are kept
lower than the terminal block.
Excess wire is not to be looped close to the
thermostat or tank.
In addition to the Pressure & Temperature
Relief Valve, electric storage water heaters
are tted with a combination thermostat and
over-temperature energy cut-out.
This device must not be tampered with
or removed. Replacement of this device
must only be carried out by a licensed
tradesperson or the manufacturer.
The water heater must not be operated
unless this device is tted and in working
order.
COLD WATER CONNECTION:
The water heater is intended to be
permanently connected to the water supply
main, and not connected by a hose-set.
This water heater is designed for direct
connection to water supply pressures of up
to 800 kPa on 25L and 50L capacities.
Where the mains pressure can exceed or
uctuate beyond this pressure, a pressure
reducing valve must be tted in the cold
water inlet supply.
Instructions explaining how the water heater
can be drained can be found on page 5.