Használati útmutató Wolf Challenger XL C60SC

Wolf sütő Challenger XL C60SC

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Wolf Challenger XL C60SC (19 oldal) a sütő kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/19
INSTALLATION & OPERATION MANUAL
CHALLENGER XL Series
Gas Restaurant Ranges
MODELS:
C24S C36(S,C)
C48(S,C) C48SS
C60(S,C)(S,C) C72(S,C)(S,C)
www.wolfrange.com
ITW Food Equipment Group, LLC
10405 Westlake Drive
Charlotte, NC 28273
RETAIN THIS MANUAL FOR FUTURE USE
FORM F35696 Rev. E (07-08)
- 4 -
LOCATION
The equipment area must be kept free and clear of combustible substances.
Installation clearances: COMBUSTIBLE NON-COMBUSTIBLE
CONSTRUCTION CONSTRUCTION
Back: 6" (152 mm) 0"
Right Side: 10" (254 mm) 0"
Left Side: 10" (254 mm) 0"
The installation location must allow adequate clearances for servicing and proper operation. A minimum
front clearance of 35" (889 mm) is required.
The ranges are suitable for installation on combustible floors when 6" (152 mm) adjustable legs or
casters are used. When legs or casters are removed, use only on noncombustible floors, curb, or
platform, with front appliance base projecting 3" (76 mm) beyond curb or platform.
The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure
there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Your Wolf Range must be installed in accordance with:
In the United States of Ame rica:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400 N.
Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1
Batterymarch Park Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with
a damper or with a power means of exhaust shall comply with 248 CMR.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
LEG/CASTER ASSEMBLY
The range is shipped fully assembled, except for the legs. The range is provided with 6"(152 mm)
adjustable stainless steel legs (hardware included), packaged in a box located inside of the oven. A set
of 6"(152 mm) casters are available as an optional field installable accessory.
RANGE SERIES LEGS TO INSTALL CASTERS TO INSTALL
C24 4 4
C36 4 4
C48 6 6
C60 6 6
C72 6 6
Installation of Legs/Casters:
1. Carefully tip range on its side.
2. Align holes in leg/caster mounting plate with pre-drilled holes in bottom of range located in each of
the four corners. Two additional legs/casters must be installed on the C48, C60, and C72. The
additional legs/casters should be installed utilizing the pre-drilled holes shown in Figure 1.
Figure 1 - Cross Chassis Leg/Caster Mounting
3. Attach mounting plate to bottom of range using four ¼ - 20 x self tapping screws (provided). If
casters are being installed, the locking casters should be mounted on the front.
4. After all legs/casters have been installed, carefully return the range to its upright position.
(For additional leg information, see Leveling section of this manual).
Ranges mounted on casters must use a flexible connector (not supplied by Wolf) that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69•CSA 6.16 and a quick-disconnect
device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI
Z21.41•CSA 6.9. In addition, adequate means must be provided to limit movement of the appliance
without depending on the connector and the quick-disconnect device or its associated piping to limit
appliance movement. Attach the restraining device at the rear of the range.
- 5 -

Termékspecifikációk

Márka: Wolf
Kategória: sütő
Modell: Challenger XL C60SC

Szüksége van segítségre?

Ha segítségre van szüksége Wolf Challenger XL C60SC, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók sütő Wolf

Wolf

Wolf M Series Útmutató

16 Október 2024
Wolf

Wolf DF484CG Útmutató

7 Október 2024
Wolf

Wolf CG365P Útmutató

6 Október 2024
Wolf

Wolf DF48650P Útmutató

3 Október 2024
Wolf

Wolf DF604GF Útmutató

21 Szeptember 2024
Wolf

Wolf GR486GLP Útmutató

19 Szeptember 2024
Wolf

Wolf SO2450TT Útmutató

18 Szeptember 2024
Wolf

Wolf GR364G Útmutató

18 Szeptember 2024
Wolf

Wolf GR304 Útmutató

18 Szeptember 2024

Útmutatók sütő

Legújabb útmutatók sütő