Használati útmutató Western Co. WR20

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Western Co. WR20 (4 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/4
M
M
MA
A
AN
N
NU
U
UA
A
AL
L
LE
E
E
U
U
UT
T
TE
E
EN
N
NT
T
TE
E
E
W
W
WR
R
R1
1
10
0
0/
/
/2
2
20
0
0/
/
/3
3
30
0
0
I
IIT
T
T
V
V
V1
1
1.
.
.5
5
5
Questo documento é proprietà riservata dalla WESTERN CO. Srl. E’ vietata la riproduzione di informazioni contenute in questo documento senza consenso scritto della WESTERN CO. Srl.
1
REGOLATORE DI CARICA BATTERIA DA MODULO FOTOVOLATICO
WR 10/20/30
Recapito:
WESTERN CO. srl
Via Pasubio 1
63074 San Benedetto del Tronto (AP)
tel 0735 751248 fax 0735 751254
e-mail: info@western.it
web: www.western.it
Caratteristiche
WR10/20/30 è un regolatore di carica da moduli fotovoltaici per batterie elettriche
che può essere impiegato in piccoli o grandi impianti per uso domestico, industriale
o impianti di telecomunicazioni. Esso controlla la corrente del modulo fotovoltaico
con la tecnica chiamata PWM e controlla la scarica della batteria distaccando il
carico in caso di scarica profonda della batteria. Il carico può essere attivato
secondo diversi programmi selezionabili dall’utente: carico sempre acceso, carico
acceso solo di giorno, carico acceso solo di notte, carico acceso solo di notte
configurabile per un numero di ore compreso da 1 a 16. I vari programmi di
gestione carico rendono il WR10/20/30 la soluzione completa in molte applicazioni
fotovoltaiche; ad esempio per alimentare telecamere che debbono funzionare solo
di giorno, oppure per alimentare lampeggiatori o segnalazioni stradali che debbono
funzionare solo di notte o per alimentare sistemi di illuminazione che debbono
funzionare per un determinato numero di ore per notte. Il WR10/20/30 rileva lo
stato giorno/notte in base alla tensione di modulo; quindi non è necessario
collegare ulteriori sensori al regolatore.
Sono disponibili tre versioni: WR10, WR20 e WR30 rispettivamente per correnti di
modulo PV massimo 10A (WR10), 20A (WR20) e 30A (WR30). Quando in questo
manuale scriviamo WR10/20/30 significa che ci riferiamo a tutte e tre le versioni.
La tensione di ricarica è compensata in temperatura in modo da caricare batterie
anche in condizioni di temperatura estreme (da -10 a 60 °C) senza comprometterne
la vita utile. Si possono impostare programmi di carica per batteria ermetiche/gel
(SEAL) o per batteria ad acido libero (FLOOD). In fig 5 sono riportate le tensioni di
ricarica in funzione della temperatura per i due programmi impostabili. E’
obbligatorio verificare nel manuale della propria batteria il programma di ricarica
più adeguato.
La batteria può avere tensione nominale sia 12V che 24V; alla prima connessione il
WR10/20/30 misura la tensione di batteria e se questa è maggiore di 18V imposta i
programmi di ricarica per batteria a 24V, mentre se è inferiore ai 18V imposta il
programma di ricarica per batterie a 12V.
Il circuito p1-ha le seguenti protezioni:
Inversione di polarità della batteria: se si invertono i morsetti di batteria il
WR10/20/30 non alimenta il carico, disabilita la carica della batteria e segnala
all’operatore un errore.
Corrente inversa sul modulo fotovoltaico: durante la notte, quando il modulo
fotovoltaico non produce corrente, il regolatore WR10/20/30 ha internamente un
diodo di blocco che evita la scarica della batteria verso il modulo fotovoltaico.
Low-battery: Quando la tensione di batteria scende sotto la soglia Vlb (impostabile
dall’utente) il WR10/20/30 toglie l’alimentazione sulla sua uscita LOAD in modo da
proteggere la batteria da scariche profonde.
Cortocircuito sul carico: qualora la corrente sul carico superi il valore nominale pari
a 10,0A per il WR10, 20,0A per il WR20 e 30,0A per il WR30 per più di 0,5 secondi il
regolatore distacca il carico.
Sovra-temperatura: quando la temperatura interna supera gli 80°C vengono
distaccati sia il modulo PV sia il carico in modo da evitare che l’eccessivo
surriscaldamento porti a rottura del circuito.
Sovraccarico da modulo PV : se la corrente dal modulo supera il valore massimo
consentito (10,0A per il WR10, 20,0A per il WR20 e 30,0A per il WR30) si disabilita
la ricarica a protezione del circuito interno.
Installazione
Per un corretto smaltimento del calore prodotto, specialmente quando il
WR10/20/30 lavora ad elevate correnti, bisogna installarlo in modo da non ostruire
la circolazione d’aria sottostante il regolatore.
Il WR10/20/30 va fissato su una parete verticale o su di una superficie orizzontale
di tipo non infiammabile e protetto dall’umidità; quindi non può essere installato in
ambiente esterno. Per installazioni all’esterno il WR10/20/30 va alloggiato in una
adeguata cassetta protetta all’acqua e all’umidità, meglio se metallica in modo che
possa smaltire il calore prodotto.
Il regolatore va posto il più vicino possibile alla batteria in modo da rendere i cavi
più corti possibile. La sezione dei cavi deve essere scelta in modo da evitare che
durante il funzionamento del sistema la caduta di tensione sia inferiore al 3% della
tensione nominale del sistema. Per moduli PV con correnti maggiori di 10A
consigliamo l’uso di sezioni di cavo di 10mm
2
, per moduli PV da 5A a 10A
consigliamo la sezione di cavo di 6mm
2
e per moduli PV con corrente inferiore a 5A
consigliamo la sezione di 4mm
2
.
In fig. 2 è riportato lo schema di collegamento elettrico del WR10/20/30. Il
collegamento della carcassa alla terra non è obbligatorio, p1-ma è consigliato per una
più efficace protezione alle scariche atmosferiche.
Qualora sia richiesto di connettere un morsetto della batteria alla terra è possibile
farlo come in fig 3a; é possibile
connettere insieme alla terra i
morsetti +PAN, +BATT e +LOAD come
in fig 3b, non è invece possibile
connettere la terra come in fig 3c.
Il modulo PV da collegare al
regolatore WR10/20/30 va scelto
rispettando i seguenti criteri:
-La corrente di cortocircuito (Isc) del
modulo PV non deve superare la
corrente nominale 10A per il WR10,
20A per il WR20 e 30A per il WR30.
-La tensione a circuito aperto Voc del
modulo PV va scelta in base alla
tensione della batteria da ricaricare.
Quando una batteria è in carica la sua
tensione varia da 11.0V a 14.4V per
sistemi a 12V e da 22.0V a 28.8V per
batteria a 24V. Il modulo PV va scelto
in modo che la sua tensione di
massima potenza Vmp sia circa
uguale alla massima tensione di
batteria fig. 4b e 4e. Qualora si scelga
un modulo con una Vmp molto
maggiore della massima tensione di
batteria (fig. 4a e 4d) si rischia di non
sfruttare tutta la potenza del modulo
PV. Invece se la Vmp è scelta troppo
piccola rispetto l’intervallo di
variazione della tensione di batteria
(fig. 4c e 4f) si rischia che la batteria
non riuscirà mai a caricarsi alla sua massima tensione.
Ipan
Vpan
Vbatt
11V
Vbatt
14.5V
Vpan Vpan
Vbatt
11V
Vbatt
14.5V
Vbatt
11V
Vbatt
14.5V
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
Vpan
Vbatt
22V
Vbatt
28.8V
Vpan Vpan
Vbatt
22V
Vbatt
28.8V
Vbatt
22V
Vbatt
28.8V
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
g. 4a
g. 4b
g. 4c
g. 4d
g. 4e
Vmp
Vmp
Vmp
Vmp
Vmp
Vmp
OK
OK
NO
NO
NO
NO
Ipan
Ipan
Ipan
Ipan Ipan
Funzionamento del sistema
Stato giorno/notte
Visualizzato nelle sole schermate di configurazione
Protezione batteria scarica attiva
Accensione carico
Indica quale programma di
ricarica è attualmente impostato
Visualizza le misure interne
Livello di
tensione nella batteria
Indicazione assorbimento
corrente sul carico
Indicazione assorbimento
corrente dal pannello PV
Pagina principale.
Visualizza la tensione di batteria, lo stato giorno/notte rilevato dal modulo PV, l’icona
del carico se accesa indica che il carico è alimentato ed è visualizzato il programma di
ricarica attualmente selezionato.
Visualizza la corrente del modulo PV. Ricordiamo che la corrente erogata dal modulo PV
dipende dallo stato di soleggiamento dello stesso e dallo stato di carica della batteria.
Con la batteria carica (Vbatt>14,4V @12V o Vbatt>28,8V @24V) anche con un buon
soleggiamento del modulo si hanno correnti di ricarica basse in quanto è il regolatore
che limita tale corrente per evitare sovraccarico della batteria.
Visualizza la potenza in watt attualmente erogata dal modulo PV.
Visualizza il contatore dell’energia erogata dal modulo in KWh. E’ possibile azzerare
questa misura premendo contemporaneamente i pulsanti per 2 secondi.
Visualizza la temperatura della batteria attualmente misurata dalla sonda interna al
WR10/20/30.
Visualizza la corrente attualmente erogata al carico; anche se in questa schermata
compare accesa l’icona del carico non è detto che questo sia effettivamente alimentato,
infatti il carico è controllato secondo il programma di gestione carico attualmente
impostato .
Visualizza la potenza attualmente erogata al carico in watt.
E’ visualizzato il contatore dell’energia in KWh consumati dal carico. E’ possibile
azzerare questo contatore premendo contemporaneamente i pulsanti per 2
secondi.
Alla pressione del tasto sinistro si ritorna alla pagina principale.
Configurazione del sistema
Si accede alle pagine di configurazione del WR10/20/30 mantenendo premuti per
almeno 2 secondi i pulsanti .
Pagina configurazione programma di ricarica
Imposta il programma di ricarica per la batteria.
Si consiglia di impostare il programma SEAL per batterie
ermetiche o al gel, invece il programma FLOOD per la ricarica
di batteria ad acido libero.
cambio pagina
Pagina Configurazione tensione di Low Battery
Imposta la tensione di intervento della protezione di Low battery (distacco del
carico in caso di batteria scarica). Alla pressione del tasto si modifica
l’impostazione da 10.8V a 12.2V per sistemi a 12V e da 21.6V a 24.4V per sistemi a
24V.
cambio pagina
Imposta la tensione di uscita da protezione di Low battery . Alla pressione del tasto
si modifica l’impostazione da 12.4V a 13.8V per sistemi a 12V e da 24.8V a
27.6V per sistemi a 24V.
Impostazione disponibile di per versione firmware ≥2.1
cambio pagina
Pagina Configurazione programma gestione carico
.
carico sempre
acceso sia di
giorno che di
notte.
carico acceso
solo di giorno.
carico acceso
solo di notte.
carico acceso di
notte per 1 ora.
carico acceso di notte per
16 ore.
cambio pagina
Visualizza alternativamente la versione firmware e la
versione 10A, 20A e 30A del regolatore.
Alla pressione del tasto sinistro si ritorna nella pagina configurazione programma di ricarica
Una volta modificate le impostazioni del WR10/20/30 queste diventano operative
solo dopo essere usciti dalla pagine di configurazione mantenendo premuti per
almeno 2 secondi i tasti .
Codici di errore
All’intervento delle protezioni interne del WR10/20/30 compaiono dei codici di
errore come riportato di seguito.
Tabella codice errore
E’ stata connessa la batteria con polarità invertite. Rivedere il collegamento
elettrico della batteria.
Interviene quando la temperatura interna del WR10/20/30 supera gli 80°C e
disattiva la ricarica. Si esce automaticamente da questa protezione quando la
temperatura interna scende al di sotto della soglia di 50°C (nota: la temperatura
interna al regolatore non è visualizzata nell’LCD). Qualora intervenga spesso
questa protezione consigliamo di alloggiare il regolatore in un luogo più fresco.
Intervenuta protezione di sovraccarico. La corrente del carico p1-ha superato il limite
massimo consentito per il WR10/20/30 ( nella tabella caratteristiche Iload
elettriche) e il regolatore p1-ha distaccato il carico per prevenire rotture interne. Nel
caso intervenga questa segnalazione è necessario verificare se la corrente
assorbita dal carico è inferiore al limite consentito. Dopo 1 minuto il WR10/20/30
alimenta nuovamente il carico.
La corrente del modulo ha superato la massima corrente consentita ( nella Ipan
tabella caratteristiche elettriche) e il WR10/20/30 ha disabilitato la ricarica per
prevenire rotture interne. Dopo circa 1 minuto il WR10/20/30 riattiva la ricarica
automaticamente. Questa protezione interviene qualora si connetta al regolatore
un modulo PV con una corrente troppo elevata ( del modulo supera la Isc Ipan
sulla tabella caratteristiche elettriche), quindi qualora intervenga questa
protezione è necessario scegliere un differente modulo.
Tensione ne carica in funzione della temperatura
sistema a 12V
13,50
14,00
14,50
15,00
15,50
16,00
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
Temperatura °C
Tensione na carica Volt
SEAL
FLOOD
Tensione ne carica in funzione della temperatura
sistema a 24V
27,00
27,50
28,00
28,50
29,00
29,50
30,00
30,50
31,00
31,50
32,00
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
Temperatura °C
Tensione na carica Volt
SEAL
FLOOD
fig. 5
CARATTERISTICHE ELETTRICHE
WR10
Min
Tip
Max
Min
Tip
Max
Min
Tip
Max
Tensione
batteria
Vbatt [V]
10
-
35
10
35
10
35
Tensione
PV
Vpan [V]
20
-
55
20
-
55
20
-
55
Corrente
PV
Ipan [A]
-
-
10
-
-
20
-
-
30
Corrente del carico
Iload [A]
-
-
10
-
-
20
-
-
30
Tensione di carica @
25°C SEAL
Vch
14.4V @12V
(default)
28.8V @24V (default)
Tensione di
carica @
25°C FLOOD
Vch
14.8V @12V
29.6V @24V
Protezione batteria
scarica
Vlb
impostabile da 10.8V a 12.2V @12V
(11.6V default)
impostabile da 21.6V a 24.4V @24V (23.2V default)
Soglia ripristino da
batteria scarica
VexLb
impostabile da 12.4V a 13.8V @12V*
(13.8V default)
impostabile da 24.8V a 27.6V @24V* (27.6V default)
Auto consumo
Isleep [mA]
8,0
8,0
8,0
Temperatura di
esercizio
Tamb °C
-
10
-
60
-
10
-
60
-
10
.
60
Potenza dissipata
Pdiss
6.8W @10A
8.0W @20A
16.0W @30A
Sezione ai morsetti
mm
2
1
-
10
1
-
10
1
-
10
Grado di protezione
IP20
* Impostazione disponibile di per versione firmware ≥2.1
Garanzia
Western Co srl garantisce la buona qualità e la buona costruzione del prodotto WR10/20/30 per un periodo di
5 anni. Le condizioni di garanzia sono consultabili sul sito
www.western.it
Fig. 2
U
U
US
S
SE
E
ER
R
R
M
M
MA
A
AN
N
NU
U
UA
A
AL
L
L
W
W
WR
R
R1
1
10
0
0/
/
/2
2
20
0
0/
/
/3
3
30
0
0
E
E
EN
N
N
V
V
V1
1
1.
.
.5
5
5
This document is the property of WESTERN CO. Srl. All rights are reserved. Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO. Srl.
2
PHOTOVOLTAIC BATTERY CHARGE REGULATOR
WR 10/20/30
Address:
WESTERN CO. Srl
Via Pasubio 1
63074 San Benedetto del Tronto (AP) - Italy
tel +39 0735 751248 fax +39 0735 751254
e-mail: info@western.it
web: www.western.it
Features
WR10/20/30 is a charge regulator from PV modules for electric batteries. It can be
used either in small or in big systems for homes, industries or telecommunication
systems. It controls the PV module current with PWM and the battery discharge by
disconnecting the load in case of deep discharge of the battery. The load can be
activated according to different programs which can be set by the user: load
always ON, load ON only during the day, load ON only during night, load ON only
during night and configurable for a number of hours included from 1 to 16. The
different programs of load management make WR10/20/30 the complete solution
in many PV applications; for example: to power supply video cameras that have to
work only during day, to power supply flashing systems or road signalling systems
that have to work only during night, to power supply lighting systems that have to
work for a specified number of hours per night. WR10/20/30 notes the day/night
status according to the PV module voltage; therefore it is not necessary to connect
further sensors to the regulator.
There are 3 versions: WR10, WR20 and WR30 respectively for PV module currents
of max 10A (WR10), 20A (WR20) and 30A (WR30). In this manual when we write
WR10/20/30 p2-we refere to all versions WR10, WR20 and WR30.
The charge voltage is compensated in temperature so to charge the batteries even
with extreme temperature conditions (from -10 to 60 °C) without compromising
the useful life. You can set charge programs either for GEL/AGM sealed batteries
(SEAL) or for flooded lead acid batteries (FLOOD). In fig. 5 there are the charge
voltages according to the temperature for the two programs that can be set. It is
compulsory to verify in the technical manual of your battery if the charging voltage
is appropriate to the battery.
The battery can have a nominal voltage either 12V or 24V; at its first starting
WR10/20/30 measures the battery voltage and, if it is > of 18V, it sets the charge
program for 24V battery, while if it is < of 18V it sets the charge program for 12V
battery.
The circuit has got the following protections:
Polarity inversion of battery: if you invert the battery terminals, WR10/20/30 does
not power on, it does not power the load and it signals a mistake to the operator.
Revers current on PV modules: during night, when PV module does not produce
current, WR10/20/30 charge regulator has an internal reverse current diode that
avoids the battery discharge towards the PV module.
Low-battery: When battery voltage drops below Vlb threshold (selectable)
WR10/20/30 charge regulator disconnects the load to protect the battery from
deep discharge.
Short-circuit on the load: If the current on load overcomes the nominal value equal
to 10,0 A for WR10, 20,0A for WR20 and 30,0A for WR30 for more than 0,5
seconds, the regulator disconnects the load.
Over-temperature: when the internal temperature overcomes 80°C, both PV
module and load are disconnected so to avoid that excessive over-heating
provokes the breakage of the circuit.
Overload on PV module: if current from PV module overcomes the Ipan max
WR10/20/30 stops the charge current to protect its internal circuit.
Installation
For a right heat dissipation you have to install WR10/20/30 so not to obstruct the
movement of air below the regulator, especially when it works at high
temperatures.
WR10/20/30 must be fixed either on a vertical wall or on an horizontal not-
flammable surface and protected against humidity; therefore it cannot be installed
in outdoor applications. For outdoor applications WR10/20/30 has to be housed in
a proper box that has to be protected against water and humidity, even better if
the box is metallic so to dissipate the produced heat.
The regulator has to be placed as close as possible to the battery so to make the
cables as short as possible. The cables’ section has to be chosen so to avoid that,
during the system working, voltage drop is less than 3% of system nominal voltage.
For PV modules with currents > of 10A we advise the use of cables section of
10mm
2
; for PV modules from 5A to 10A we advise the use of cables section of
6mm
2
and for PV modules with current < to 5A we advise the use of cables section
of 4mm
2
.
In fig. 2 there is the scheme of electric connection of WR10/20/30. The connection
of the case to the ground is not compulsory, but it is advised for a more effective
protection against lightning.
If you have to connect a battery terminal on the ground you can do it as in fig 3a; it
is possible to connect together on
the ground the connectors: +PAN,
+BATT and +LOAD as in fig 3b; on
the contrary, it is not possible to
connect the ground as in fig 3c.
The PV module that has to be
connected with WR10/20/30
regulator, has to be chosen by
respecting the following criteria:
-The short-circuit current (Isc) of
PV module must not overcome
the nominal current of 10A for
WR10, 20A for WR20 and 30A for
WR30.
-The open-circuit voltage (Voc) of
the PV module has to be chosen
according to the voltage of the
battery that has to be charged.
When a battery is in charge its
voltage changes from 11.0V to
14.4V for systems @ 12V and
from 22.0V to 28.8V for battery @
24V. The chosen PV module must
have its maximum power voltage
(Vmp) equal to the maximum
battery voltage (fig. 4b and 4e). If
you choose a module with a Vmp
much greater than the maximum
battery voltage (fig. 4a and 4d)
you risk not to exploit the whole
PV module’s charge. Otherwise if
the chosen Vmp is too small in
comparison with the interval of variation of the battery voltage (fig. 4c and 4f) you
risk that the battery will not be able to charge at its maximum voltage.
Ipan
Vpan
Vbatt
11V
Vbatt
14.5V
Vpan Vpan
Vbatt
11V
Vbatt
14.5V
Vbatt
11V
Vbatt
14.5V
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
Vpan
Vbatt
22V
Vbatt
28.8V
Vpan Vpan
Vbatt
22V
Vbatt
28.8V
Vbatt
22V
Vbatt
28.8V
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
T25°C
T35°C
T55°C
g. 4a
g. 4b
g. 4c
g. 4d
g. 4e
Vmp
Vmp
Vmp
Vmp
Vmp
Vmp
OK
OK
NO
NO
NO
NO
Ipan
Ipan
Ipan
Ipan Ipan
System working
Day/night status
It is displayed only in the configuration screens Low battery protection is active
Load Power on
It indicates whic h charge
program is actually set
It displays internal measures
Voltage level in the battery
Indication of current
abs orption on the load
Indication of current
absorption from PV
Main page.
It shows the battery voltage, the day/night status taken from the PV module. If the load
icon is ON it means that the load is power supplied and you can see the charge program
currently selected.
It shows the current of PV module. We remember that the current delivered by the PV
module depends on its state of sun irradiation and on the battery state of charge. In
condition of charged battery (Vbatt>14,4V @12V or Vbatt>28,8V @24V) even with a
good sun irradiation of the module we have low charge currents since the regulator
limits such a current to avoid a battery overcharge.
It shows the power in watt actually delivered by the PV module.
It displays the counter of energy that is delivered from the module in KWh. It is possible
to reset such measure by pushing at the same time the push-buttons for 2
seconds
It displays the temperature of battery that is measured by the internal sensor to
WR10/20/30.
It displays the current actually delivered to the load; even if in this screen there is the
load icon ON, this does not mean that the load is not effectively power supplied. In fact
the load is controlled according to the program of load management which is actually
set.
It shows the power actually delivered to the load in watt.
Here you can see the counter of energy in KWh that have been consumed by the load. It
is possible to reset this counter by pressing at the same time the push-buttons
for 2 seconds.
When you press the left button you return to the main page.
System configuration
You can access to the configuration pages of WR10/20/30 by pressing for at least 2
seconds the push-buttons .
Configuration page of charge program
It sets the charge program for the battery.
We advise to set the SEAL program for PB sealed AGM / GEL
batteries, while we advise to set the FLOOD program for
the charge of flooded lead acid batteries.
change of page
Configuration page of Low Battery voltage
It sets the intervention voltage of Low Battery protection (load disconnection in
case of discharged battery). By pressing the push-button you modify the
setting from 10.8V to 12.2V for systems @ 12V and from 21.6V to 24.4V for
systems @ 24V.
change of page
It sets the threshold for exit from low battery protection. By pressing the push-
button you modify the setting from 12.4V to 13.8V for 12V systems, and from
24.8V to 27.6V for 24V systems.
This setting is available only for firmware version ≥2.1
cambio pagina
Configuration page of load management program
.
Load always ON
either during day
or during
night.
Load ON only
during day
Load ON only
during night
.
Load ON during
night for 1 hour
.
Load ON during night for 16
hours
change of page
It displays the software version and ampere size of regulator
(10A / 20A / 30A).
Press left button to go back to the configuration page of charge program.
Once you have modified the settings of WR10/20/30 these become operative only
after having left the configuration pages by pressing for at least 2 seconds the
push-buttons
Error code
When in WR10/20/30 an internal protection occurs, it is displayed the error code
(see table below).
Error code table
You have connected the battery with inverted polarities. Control the wiring.
It occurs when internal temperature of WR10/20/30 rises above 80°C. In this case battery charge
is disabled. You comes out automatically from this protection when the temperature drops below
the threshold of 50 ° C (internal temperature is not displayed in the LCD). If this protection occurs
often p2-we suggest to install the WR10/20/30 in a cooler place.
It occurred the overload protection. The load current has exceeded the maximum limit allowed
for the WR10/20/30 ( in table electric feature) and the regulator has disconnected the load Iload
to prevent internal breaking. If you see this message you should check if the current absorbed by
the load is lesser than the permitted limit. After 1 minute the WR10/20/30 power supplies back
the load.
The PV current has exceeded the maximum allowable current ( in table electric feature) and Iload
the regulator has disconnected the PV to prevent internal breaking. After about 1 minute
WR10/20/30 re-activates the charge automatically. You have this protection when you connect to
the regulator a PV module with too high current ( of the PV module exceeds on the table Isc Ipan
of electrical features); therefore you must choose a different PV module.
Charge voltage To temperature for 12V battery
13,50
14,00
14,50
15,00
15,50
16,00
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
Temperature °C
Charge voltage Volt
SEAL
FLOOD
Charge voltage To temperature for 24V battery
27,00
27,50
28,00
28,50
29,00
29,50
30,00
30,50
31,00
31,50
32,00
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
Temperature °C
Charge voltage Volt
SEAL
FLOOD
fig. 5
ELECTRIC FEATURES
WR10
WR20
Min
Tip
Max
Min
Tip
Max
Min
Tip
Max
Battery voltage
Vbatt [V]
10
-
35
10
35
10
35
Module voltage
Vpan [V]
20
-
55
20
-
55
20
-
55
Module current
Ipan [
A]
-
-
10
-
-
20
-
-
30
Load current
Iload [A]
-
-
10
-
-
20
-
-
30
Charge voltage @
25°C SEAL
Vch
14.4V @12V
(default)
28.8V @24V (default)
Charge voltage @
25°C FLOOD
Vch
14.8V @12V
29.6V @24V
Threshold of low
battery protection
Vlb
impostabile d
a 10.8V a 12.2V @12V
(11.6V default)
impostabile da 21.6V a 24.4V @24V (23.2V default)
Threshold for exit
from low battery
protection
VexLb
impostabile da 12.4V a 13.8V @12V*
(13.8V default)
impostabile da 24.8V a 27.6V @24V* (27.6V default)
Self
-
consump
tion
Isleep [mA]
8,0
8,0
8,0
Working temperature
Tamb °C
-
10
-
60
-
10
-
60
-
10
.
60
Power dissipation
Pdiss
6.8W @10A
8.0W @20A
16.0W @30A
Wiring section
mm
2
1
-
10
1
-
10
1
-
10
IP box degree
IP20
*This setting is available only for firmware version ≥2.1
Mechanical dimensions
Warranty
Western Co. Srl guarantees the good quality and good manufacture of its own Products obliging itself, during
the warranty period of 5 (five) years. Warranty condictions can be read at .
www.western.it

Termékspecifikációk

Márka: Western Co.
Kategória: nincs kategorizálva
Modell: WR20

Szüksége van segítségre?

Ha segítségre van szüksége Western Co. WR20, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Western Co.

Western Co.

Western Co. WR20 Útmutató

12 December 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

Hager

Hager TYA610A Útmutató

12 December 2024
Hager

Hager RED112X Útmutató

12 December 2024
Hager

Hager 80161869 Útmutató

12 December 2024
Hager

Hager 80162865 Útmutató

12 December 2024
Hager

Hager 80161865 Útmutató

12 December 2024
Hager

Hager 80162869 Útmutató

12 December 2024
Hager

Hager TN204S Útmutató

12 December 2024
Hager

Hager VS218PZF Útmutató

12 December 2024
Hager

Hager VS318PZF Útmutató

12 December 2024
Hager

Hager VS418PZF Útmutató

12 December 2024