BY-ALARM PLUS
By-alarm Plus barrier kit consisting of TX/RX active infrared pair (AIR) with outdoor range of 60 metres, with 4 selectable channels to create a
column barrier comprising several stacked detectors, IP65, 1 NO/NC 28 VDC 0.2A relay output for alarm, 1 NC 28 VDC 0.2A relay output to prevent
false alarms due to adverse weather conditions (fog, rain, snow), 10.5-28 VDC power supply with 48 mA 12V surface, pole, column mounting, for
outdoor use.
The barrier is equipped with a compact photoelectric detector with high durability IP65” and stable detection performance levels” which drastically reduce false and sealed enclosure
alarms caused by sudden changes in the outdoor environment and allow for a wide range of uses. The barriers come with a roof to prevent the formation of dew on the lower beams
and also allow easy maintenance thanks to the flat surface of the cover. The adjustment is made simply yet precisely with the horizontal alignment knob and the vertical adjust-
ment screw; the 4-level alarm LED indicates the alignment condition via 4 different processes to achieve easy and accurate alignment before the final adjustment. The barrier
is equipped with an A.G.C. circuit (automatic gain control) which constantly controls gradual variations in the signal caused by atmospheric conditions; it adjusts sensitivity to
maintain the signal level at optimum environmental conditions even with 99% obstruction of the beam caused by heavy rain, fog or snow. The beam interruption time (necessary
to release an alarm) can be adjusted and adapted to any situation such as protecting a wall or fence, for instance. The beam frequencies can be selected and are used to avoid
undesired interference which could occur when using multiple beams over long distances or barriers installed in a column. The false alarm due to adverse weather conditions
circuit allows a fault signal to be sent when the intensity of the beam is below the threshold level due to thick fog, mist, rain or other adverse conditions; the fault signal output
remains for the whole time the beam intensity remains below the threshold level.
CHARACTERISTICS
Power supply: 10.5-28 VDC
Absorption: 48 mA max (transmitter 10 mA, receiver 38 mA)
Range: 60 m
Max transmission/reception distance in an open field: 600 m
Alignment angle of the internal optics: ±9horizontal, ±5° vertical
Detection mode: infrared beam interruption
Selectable beam frequency: 4 channels
Interruption time: selectable between 50, 100, 250 and 500 ms (4 positions)
Alarm output: NO or NC 28 VDC 0.2 A max.
Alarm period: 2 sec (±1) rated
False alarm due to adverse weather conditions output: NC 28 VDC 0.2 A max.
Tamper output: NC 28 VDC 0.1 A (max), open when the front cover is removed
Operating temperature: from –35°C to +60°C (use heater 01743.H in the event of temperatures below –25 °C).
Ambient humidity: 95%
Protection degree: IP65
CHARACTERISTICS OF HEATER 01743.H
Power supply: 24 VAC/DC
Absorption: 420 mA max
Thermostat: 60°C
Operating temperature: from -35 °C to +60 °C
LED SIGNALLING
Transmitter
on green -> Power on
Receiver
on red -> Alarm
flashing red or off -> Beam reception
Alarm memory: on red or flashing (for full details please refer to the section entitled “Alarm memory”)
INSTALLATION RULES
Installation must be carried out by qualified persons in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are
installed.
Do not use the device for purposes other than to detect moving objects such as people or vehicles.
Do not use the device to activate roller shutters, shutters, etc. which could damage property and/or harm people.
Do not touch the base of the device or the power supply terminals with wet hands and do not touch the product when it has been rained on.
Do not disassemble the product for repair reasons; this could cause a re or damage the device.
Do not exceed the voltage or current values indicated in each terminal.
Do not pour water onto the device; it could penetrate the inside and damage it.
Clean and check the device is working properly on a regular basis.
REACH (EU) Regulation no. 1907/2006 Art.33. The product may contain traces of lead.
WEEE - User information
The crossed out bin symbol indicates that the product must be sent to separate collection facilities for recovery and recycling, in compliance with the national laws of EU Countries that implement the WEEE Directive. The objective is to prevent
any harmful effects on the environment and on human health by ensuring that products are disposed of correctly, avoiding illegal disposal sanctioned by law.
To dispose of the product correctly, please check local dispositions in your country.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01743 01 2411
THE IR BARRIER
INSTALLATION SUGGESTIONS
Detection range and installation Alignment angle
Horizontal Vertical
60 m max
0.7 1 m
Pole fixing
Ø of pole
32-48 mm
Transmitter Receiver
Transmitter Receiver
We recommend you set aside 60 cm of cable at the top
pole outlet to allow for connections with devices
60 cm
1 m
180° (±90°)
10° (±5°)
Comprising a TRANSMITTER and a RECEIVER
2 IR beams configurable on 4 different frequencies
High performance waterproof structure
Horizontal pairing facilitated by LED indicator
• Programmable beam interruption period
• Tamper and false alarm due to adverse weather conditions output
Transmitter
2
34
6
5
Receiver
7
9
10
11
12
13
14
8
16
15
1. Roof
2. Front cover
3. transmission condition LED
4. Base
5. Beam selection time 1-way switch
6. Optical unit
7. Cable through holes
8. Alarm memory LED
9. Alarm indicator LED
10. Control socket outlet
11. Alignment viewfinder
12. Waterproof pin
13. Horizontal alignment knob
14. Vertical alignment screw
15. Settings selection dip switches
16. Beam frequency selection 1-way switch
CAUTION: The transmitter and receiver must be aligned.
Misaligned installation leads to a reduced barrier detection range.
1
50 100 250 500 (ms)
Wiring distance between power supply unit and detector
Make sure the wiring distance from the power supply unit falls within the distance indicated. When using two
or more devices on one conductor, the maximum length is obtained by dividing the maximum conductor
length indicated below by the number of devices used
Power supply cable
Section Max. length
0.5 mm
2
700 m
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01743 01 2411
INSTALLATION
1
Remove the cover and the screw
Cover blocking screw
Roof
Device base blocking screw
When removing the cover, do not place your fingers on the roof, as this could damage it.
1) Loosen the cover blocking screw to remove the cover.
2) Turn the optical unit and open the waterproof pin.
3) Loosen the device base blocking screw and slide the fixing plate down to detach the
base of the device.
2
Plate fixing
Surface mounting
Surface mounting fixing screws
Fixing plate
Pole fixing (1 plate)
3
Wiring
Use cables compliant with the following:
1) Cable diameter: Ø 4 7 mm
2) When using cables that differ from those indicated above, seal the
cable through hole with a waterproof sealant (silicone, etc.) to prevent
water seeping in through the slit.
3) Number of cables: max 3
Up to 3 cables can be housed in the device. The cable must be inserted
as follows:
* The through hole 2 must be pierced with a screwdriver, etc.
** To make the through hole 3, you will need to cut the cable through
door with a cutter, etc. Once you have inserted the cable, seal the
cable through door with a waterproof sealant (silicone, etc.) to prevent
water seeping in.
Cable through hole 1 Cable through hole 2* Cut**
Hole to pierce
Part to eliminate
Pole fixing (2 plates)
Pole blocking screws
Plate blocking screw

Termékspecifikációk

Márka: Vimar
Kategória: nincs kategorizálva
Modell: 01743

Szüksége van segítségre?

Ha segítségre van szüksége Vimar 01743, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Vimar

Vimar

Vimar EZS25 Útmutató

3 Április 2025
Vimar

Vimar EZP20 Útmutató

3 Április 2025
Vimar

Vimar R288 Útmutató

3 Április 2025
Vimar

Vimar EZS20 Útmutató

3 Április 2025
Vimar

Vimar 01467 Útmutató

2 Április 2025
Vimar

Vimar 01741 Útmutató

2 Április 2025
Vimar

Vimar 01970 Útmutató

2 Április 2025
Vimar

Vimar 01743 Útmutató

2 Április 2025
Vimar

Vimar 32101 Útmutató

2 Április 2025
Vimar

Vimar RS05 Útmutató

1 Április 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva