Turbo Air Speed up the Pace of Innovation
Underbar Equipment
Back Bars
Installation and Operation Manual
CAUTION!
PLEASE KEEP POWER
SWITCH ON BEFORE
OPERATING THIS EQUIPMENT
Please read this manual completely before attempting to install or operate this equipment!
TBB-1SB
TBB-2SG TBB-2SB
TBB-3SG TBB-3SB
TBB-4SG TBB-4SB
www.turboairinc.com
SD series: Stainless Steel Exterior
SB series: Black Laminated Vinyl Exterior or Black Powder Coating Exterior
2
CONTENTS
SPECIFICATIONS
SERIAL NUMBER
PAGE
SPECIFICATION 2
SERIAL NUMBER 2
INSTALLATION OF THE CASTERS 3
Draft Arms Towers Installation Schematic Diagram 3
Beer Line & CO Line Installation Schematic Diagram24
Caution "IMPORTANT" 5-6
INSTALLATION 7
CLEANING 8
BASIC OPERATION 9
BEFORE REQUESTING SERVICE 10
WARRANTY 11-12
MODEL COMPH.P. V/Hz REFRIGERANT AMPS WEIGHT
TBB-SB 1/10 110-120V/60Hz R-134a 4.0A 235 lbs
TBB-2SG/SB 1/3, 1/4 110-120V/60Hz R-134a 7.0A 344/332 lbs
TBB-3SG/SB 1/3, 1/4 110-120V/60Hz R-134a 7.0A 385/369 lbs
TBB-4SG/SB 1/3 110-120V/60Hz R-134a 7.5A 485/493 lbs
The serial number is located on the rating label which is on interior left side wall.
Please retain the unitʼs serial number for service purpose.
3
INSTALLATION OF THE CASTERS
DRAFT ARMS TOWERS
Installation Schematic Diagram
According to model, refer to the assembly position of casters.
TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG
TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG
TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG
TCB-2SD, TCB-3SD, TCB-4SD
TBD-2SD, TBD-3SD, TBD-4SD
TBD-2SB, TBD-3SB, TBD-4SB
Screw(M4xL12) x 4EA
Screw(M4xL12) x 4EA
Draft Tower Assembly
Draft Tower Assembly
Rubber Gasket
Rubber Gasket
* Assemble DRAFT TOWER as above drawing.
This picture is a plan view of bottom cabinets.
CB is an abbreviation of the caster with a brake.
Other casters don't have a brake.
4
BEER LINE & CO2 LINE Installation Schematic Diagram
* Assemble BEER LINE & CO LINE as above drawing.2
Distributor Fixture
CO2 Line
Beer Line#1
Beer Line#2
Beer #1
Beer #2
CO2
TCB-2SD, TCB-3SD, TCB-4SD
TBD-2SD, TBD-3SD, TBD-4SD
TBD-2SB, TBD-3SB, TBD-4SB
5
CAUTION "IMPORTANT"
On direct-draw dispensers the drain is
located at the front of the cabinet.
To plumb in the drain, connect 5/8
P.V.C. pipe to the 5/8barbed fitting
supplies with the unit.
DIRECT DRAW
* Don't pull out or Turn drain line.
6
CAUTION "IMPORTANT"
1. POWER CORD
- Be sure the power cord is connected to the proper voltage, and amps
should be run before connecting power cord to outlet.
- A protected circuit of the correct voltage and amperage must be run for
connection of the line cord.
- Unplug the unit, whenever performing maintenance functions or cleaning
the refrigerated cabinet.
- Compressor warranty is void if burnt out due to low voltage.
2. RE-STARTING
- If unpluged, wait 5 minutes before re-starting.
A. Excessively opening the door will cause the breakdown.
B. Handle with care as shutting the door.
TBB-2SG, TBB-3SG,
TBB-4SG
7
INSTALLATION
1. GOOD AIR CIRCULATION
- Do not place any object that will restrict air flow in front or back grills.
- Turbo air highly recommends that there is ample space in rear of unit. 3 inches or
more is best.
2. PLACE ON STRONG GROUND
- Be sure the location chosen has a floor strong enough to support the total weight of
the cabinet and contents.
3. DO NOT PLACE NEAR HEAT
- Be sure to avoid hot corners and locations near stoves.
- High ambient temperature will make cooling efficiency lower.
4. INDOOR USAGE ONLY
- Be sure to install this unit indoor, so it will not get wet from the rain.
5. STABILIZING
- Make sure the unit is installed in a stable condition.
6. LEVELING
- Be sure that the unit is level from front to back and side to side.
7. Do not plug in with other units on same breaker.
8. Do not run on extension cord.
9
BASIC OPERATION
1. The controller(thermostat) is located at the back right inside of the unit.
2. The factory setting maintains about 38˚F(3˚C) inside.
3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder
temperature.
4. The thermostat controls compressorʼs cycling by sensing inside temperature.
5. When unit will not be used for a long time, unplug the unit.
REFRIGERATORS
Temperature Controller
(Thermostat)
10
BEFORE REQUESTING SERVICE
SYMPTOMS CAUSES SOLUTIONS
Cooler is freezing
products
The unit does not
refrigerate at all.
The unit does not
refrigerate well.
There is a loud noise.
There are dew-drops
on the unit exterior.
There are dew-drops
on the unit interior.
Thermostat set too cold.
There is a power connection
failure problem.
The unit is in sunlight or near a
heating device.
Product was put in warm.
The unit lid is opened too
frequently or left open too long.
The temp. dial is not on the
correct position.
The condenser is clogged.
The floor is too weak or the
leveling feet are set incorrectly.
The backside of the unit is too
close to the wall.
High-moisture air can produce
dewdrops during rainy seasons.
The lid is opened too frequently
or left open too long.
Turn the temperature dial to a
warmer setting.
Check the power cord to make
sure the unit is pluged in it
correctly.
Move out of sunlight or away
from heater.
Check the condition of stored
product.
Check the position of the temp
control dial.
Check the installation.
Wipe with a dry cloth.
Keep the lid closed to remove
dewdrops.
The following points are not malfunctions:
• A water-flowing sound can be heard when the compressor stops.
This is the sound of REFRIGERANT flowing.
• The compressor does not run during the defrost cycle.