Használati útmutató True North TN24

Olvassa el alább 📖 a magyar nyelvű használati útmutatót True North TN24 (40 oldal) a Fűtő kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/40
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
MODEL: TN24
SERIES: A
DIRECT VENT FREE STANDING
GAS STOVE INSTALLATION
AND OPERATING INSTRUCTIONS
090719-40 100000458-50TN24.BODYA
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury or death.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certied kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Visit www. truenorthstoves.com for the most recent version of this manual
SERIAL #
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier call the re
department.
- Installation and service must be performed by a
qualied installer, service agency or the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
2150118-40 100000458
TN24.BODYA
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with the appliance and
shall be installed for the protection of children and
other at-risk individuals.
We recommend that our gas hearth
products be installed and serviced by
professionals who are certied in the
United States by the National Fireplace
Institute® (NFI) as NFI Gas Specialists
Table of Contents
Important Note for the Commonwealth
of Massachusetts: 3 ....................................................
Owner Information
Caution 4 ....................................................................
Proposition 65 note 4 ...............................................
Safety 5 .......................................................................
First Fire 5 ...................................................................
Manufactured (Mobile) Homes 6 ................................
Installation Requirements 6 ........................................
Special Operator Note 6 .............................................
Remote Control Operation 7 ......................................
Warnings and Cautions 11 .........................................
Maintenance 12 ..........................................................
Lighting Instructions 13 ..............................................
Installer Information
TN24 Gas Stove Dimensions 14 ...............................
Clearances to Combustibles 15 .................................
Locating the Gas Stove 15 .........................................
Vent Terminal Clearance 16 ........................................
Vent Terminal Minimum Clearances 16 ......................
TN24 Co-Axial Venting Chart 17 ................................
TN24 Co-Linear Venting 18 ........................................
Optional Direct Vent Termination “Snorkel” 19 ...........
Installation 20 .............................................................
Venting Components 21 .............................................
TN24 Gas Stove rear components 22 ........................
Gas and Electrical Connection 23 ..............................
Screen mesh removal 24 .............................................
Glass door removal 24 ...............................................
Log Set Installation 26 ................................................
Glass Door Installation 28 ..........................................
Screen Mesh Installation 29 .......................................
Accent Lighting Glass Plates 31 ................................
IFC Module 32 ............................................................
Operating Procedure 32 .............................................
Damper Adjustment 33 ..............................................
Venturi Adjustment 33 ................................................
Gas Supply 34 ............................................................
Gas Pressure Check 34 ..............................................
Gas Pressure Testing Procedure 35 ...........................
Pilot Flame Adjustment 35 .........................................
Propane Conversion 36 ..............................................
Replacement Parts 37 ................................................
Wiring Diagram 38 ......................................................
Rating Label 39 ..........................................................
3
100000458 150118-40 TN24.BODYA
Important Note for the Commonwealth of Massachusetts:
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or
in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent
termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches,
the following requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and battery
back-up is installed on the oor level where the gas equipment is to be installed, in addition, the installing plumber or gas tter
shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level
of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility
of the property owner to secure the services of qualied licensed professionals for the installation of hard-wired carbon monoxide
detectors.
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard-wired
carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall
have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a
battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.089(2)(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as
adopted by the Board; and
2. Product Approved side wall horizontal vented gas fueled equipment installed in a room or structure separate from the dwelling,
building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the
equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fuel gases, but
identies “special venting systems”, the following requirements shall be satised by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions;
and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts
list and detailed installation instructions.
(e)) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment
at the completion of the installation.

Termékspecifikációk

Márka: True North
Kategória: Fűtő
Modell: TN24

Szüksége van segítségre?

Ha segítségre van szüksége True North TN24, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Fűtő True North

True North

True North TN10 Útmutató

13 Augusztus 2024
True North

True North TN40 Útmutató

13 Augusztus 2024
True North

True North TN20 Útmutató

12 Augusztus 2024
True North

True North TN24 Útmutató

12 Augusztus 2024

Útmutatók Fűtő

Legújabb útmutatók Fűtő