Metered Rack PDU
Important Safety Instructions 2
Important Warnings 2
Installation 3
Features 4
Warranty & Warranty Registration 4
Español 5
Français 9
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
14-02-330-932567.indb 1 4/23/2014 3:58:20 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will void the
product warranty.
Important Warnings
• ThePDUprovidesconvenientmultipleoutletsbutitDOESNOTprovidesurgeor 
linenoiseprotectionforconnectedequipment.
• ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfromexcessmoisture,
temperatureextremes,conductivecontaminants,dustordirectsunlight.
• DonotconnectthePDUtoanungroundedoutletorextensioncordsoradaptersthateliminate
theconnectiontoground.
• ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmustnotexceedthe
individualoutlet’sloadrating.
• ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceedthe
maximumloadratingforthePDU.
• DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-serviceable
partsinside.
• DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
• DonotattempttousethePDUifanypartofitbecomesdamaged.
• DonotattempttomountthePDUtoaninsecureorunstablesurface.
• Neverattempttoinstallelectricalequipmentduringathunderstorm.
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentortosignificantly
affectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaflammableanestheticmixturewithair,oxygenornitrousoxide.
14-02-330-932567.indb 2 4/23/2014 3:58:20 PM
3
Installation
Note: The illustrations may differ somewhat from your PDU
model.
1 Determine Installation Configuration.ThePDU
supportsfourprimaryinstallationconfigurations:1U
Rack,0URack,WallandUnder-Counter.Choosea
configurationandfollowtheinstallationinstructions
intheappropriatesectionofStep1before
proceedingtoStep2.
Note: Regardless of installation configuration, the
user must determine the fitness of hardware and
procedures before mounting. The PDU and included
hardware are designed for common rack and rack
enclosure types and may not be appropriate for all
applications. Exact mounting configurations may vary.
1-1 1U Rack Installation.AttachthePDUtotherackby
insertingfouruser-suppliedscrews( )throughtheA
PDUmountingbrackets( )andintothemountingB
holesoftherackrailasshown.
1-2 0U Rack Installation. Part 1:Removethescrews
( )attachingthemountingbracketstothePDU,C
changetheorientationofthebracketsasshownand
reattachthebrackets.Useonlythescrewssupplied
bythemanufacturerortheirexactequivalent(#6-
32,1/4”flathead). AttachthePDUvertically Part 2:
byinsertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets( )andintoB
mountingpointsintherackorrackenclosure.
1-3 Wall Installation. AfterrepeatingPart1above,
attachthePDUtoastablemountingsurfaceby
insertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets( )andintoB
securemountingpointsonthemountingsurface.
1-4 Under-Counter Installation. AfterrepeatingPart1
above,attachthePDUtoastablemountingsurface
byinsertingfouruser-suppliedscrews( )throughtheA
PDUmountingbrackets( )andintosecuremountingB
pointsonthemountingsurface.
2 Attach the input plug of the PDU to a grounded
outlet. Inserttheplugdirectlyintoagroundedoutlet
thatdoesnotshareacircuitwithaheavyelectrical
load(suchasanairconditionerorrefrigerator).
2
1-1
1-2
1-3
1-4
A
B
B
A
C
A
B
C
B
C
A
C
3
Note: Select models include an input plug adapter that converts the twist-lock input plug to a
straight-blade input plug. Attach the input plug adapter to the input plug if you wish to plug
the PDU into a compatible straight-blade outlet.
3 Attach equipment to the PDU. DonotexceedtheloadratingofthePDU.Thetotalelectrical
currentusedbythePDUwillbedisplayedonthedigitalmeterinamperes.
14-02-330-932567.indb 3 4/23/2014 3:58:22 PM

Termékspecifikációk

Márka: Tripp Lite
Kategória: elosztó
Modell: Metered PDUMH20-6