Használati útmutató SchwankAir MonsterFans JV-01045-CL

SchwankAir Ventilator MonsterFans JV-01045-CL

Olvassa el alább 📖 a magyar nyelvű használati útmutatót SchwankAir MonsterFans JV-01045-CL (12 oldal) a Ventilator kategóriában. Ezt az útmutatót 4 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/12
schwankgroup.com/monsterfans
MonsterFans Style Series
Installation Manual
2schwankgroup.com/monsterfans
Table Of Contents
Overview ..............................................................................................................................................3
Components .................................................................................................................................3
Technical Data ....................................................................................................................................4
Fusing and Thermal Limiting ...............................................................................................................5
Fuses...............................................................................................................................................5
Thermal Limiting ............................................................................................................................5
Safety ....................................................................................................................................................6
Clearances ...................................................................................................................................
Installation Preparation.......................................................................................................................7
Preparation ...................................................................................................................................7
Tools Required ..............................................................................................................................7
Items Included ..............................................................................................................................7
Hardware Included ......................................................................................................................7
Installation Procedure .........................................................................................................................9
Installation of the Mounting Hardware .....................................................................................12
Installing the Blades ....................................................................................................................14
Installing the LED Light Kit................. ...........................................................................................15
Installing the Hub Cover [with Lens] ..........................................................................................16
Electrical Installation ..........................................................................................................................18
HMI Control .........................................................................................................................................19
HMI/CAT 5 Cable Connection ..................................................................................................19
Maintenance ......................................................................................................................................20
Recommended Maintenance Schedule ................................................................................21
4schwankgroup.com/monsterfans
Technical Data
Conformity CE Low Voltage [2006/95/EC] & EMC [2004/108/EC]
Directives
EN61000-6-2:2005, EN61000-6-4:2007
IEC 60335-2-80:2015 IEC 60335-1:2015
Approvals UL61800-5-1
CSA C22.2 No113
Input Voltage Phase
Imbalance
≤2%
Input Voltage 110-240 VAC
Input Current 4.6 @ 120VAC, 2.5A @ 240VAC
Input Frequency 50-60Hz
Supported Power Systems TT TN For central ground systems, operation is permitted
without restrictions.
Humidity ≤ 95% Non-condensing
Temperature Range Transport -40°F…+160°F [40°C...+70°C]
Storage -40°F…+160°F [40°C...+70°C]
Operation -40°F…+120°F [40°C...+50°C] [with speed derating
above +104°F]
Installation Altitude 0-13,000 ft [0-4000 m]
above sea level
[with 5%/3000ft current derating above 3000ft]
Earth Leakage Current <=9 mA to PE
Power Conductor Size [Cord] Minimum 16AWG 3 Conductors rated 300VAC, use Copper Conductors
only.
For permanent connection only.
Max. Permissible Control Ca-
ble Length
100 ft un-shielded
Enclosure IP54/ NEMA 3
Protection Measures Against Short circuit, earth fault, phase loss, over voltage, under voltage, motor
stalling, over temperature, motor overload, communication loss
Environment For indoor use/outdoor
Thermal Overload Protection Drive provides internal overload protection for the motor
Pollution Degree 2
Overvoltage Category Category lll
Supply Earthing System TN-S
Impulse Voltage 2500V
Working System Voltage 150V
Packaged Fan Weight 98 lbs [44.5 kgs]
Overall Fan Weight
[no mount]
85 lbs [38.5 kgs]
LED Light Kit Weight 1.542 lbs [0.669 kgs]

Termékspecifikációk

Márka: SchwankAir
Kategória: Ventilator
Modell: MonsterFans JV-01045-CL

Szüksége van segítségre?

Ha segítségre van szüksége SchwankAir MonsterFans JV-01045-CL, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Ventilator SchwankAir

Útmutatók Ventilator

Legújabb útmutatók Ventilator

Windmill

Windmill FC07W3 Útmutató

22 December 2024
Windmill

Windmill FC07W1 Útmutató

22 December 2024
Windmill

Windmill FC07W2 Útmutató

22 December 2024
Windmill

Windmill FC07W5 Útmutató

22 December 2024
NewAir

NewAir NFN12AWH00 Útmutató

22 December 2024
NewAir

NewAir AF-600 Útmutató

22 December 2024
Yamazen

Yamazen FCR-D408 Útmutató

21 December 2024
Yamazen

Yamazen FCT-D408 Útmutató

21 December 2024
Yamazen

Yamazen FCR-J401 Útmutató

21 December 2024