Revision B
Nectre 1 MK LE
Installaon Instrucons
Keep these instrucons for future reference
Glen Dimplex Australia proudly supports the acvies of Landcare Australia through its membership of the AHHA
1
CONTENTS
1. INSTALLATION ................................................................... 1
1.1. IMPORTANT INFORMATION .................................... 1
1.2. FITTING REAR HEAT SHIELD ..................................... 2
1.3. INSTALLING THE HEATER ......................................... 2
1.3.1. Posioning the Heater 2 ........................................
1.3.2. Standard Installaon ........................................... 2
1.3.3. Corner Installaon 3 ..............................................
1.3.4. Clearance Dimensions ......................................... 3
1.3.5. Floor Protector .................................................... 3
1.4. REDUCING CLEARANCES TO COMBUSTIBLES .......... 3
1.5. INSTALLING THE FLUE .............................................. 4
1.6. INSTALLING FIRE BRICKS .......................................... 5
1.7. INSTALLING BAFFLE PLATES 5 .....................................
1.8. INSTALLING ASH PLATE 5 ...........................................
1.9. TECHNICAL DRAWINGS 6 ...........................................
1.9.1. MK1 Legs ............................................................. 6
1.9.2. MK1 Ped .............................................................. 6
1. INSTALLATION
1.1. IMPORTANT INFORMATION
The unit must be installed according to all manufacturers’
instrucons included in manual. The manufacturer is not this
liable for installaons that do not meet the requirements
outlined in this manual.
Most building regulatory authories in Australia require any
wood heater installaon to comply with Installaon Standard
AS/NZS 2918. Dierent states and councils may have varying
regulaons. Check local building regulaons before installing
the appliance.
All Nectre wood heaters have been tested to ensure they will
meet the appropriate safety standard requirements if the
instrucons in this manual are followed. As the safety and
emissions performance can be aected by altering the
appliance, no modicaons are allowed without wrien
permission from the manufacturer.
WE RECOMMEND THAT THE INSTALLATION OF YOUR NECTRE
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLER.
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING
CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
THE INSTALLATION INSTRUCTIONS IN THIS MANUAL
APPLY TO THE NECTRE 1 WOOD HEATER MODELS. MK LE
THEY HAVE BEEN TESTED FOR EMISSIONS AND
EFFICIENCY AND COMPLY ACCORDING TO AS/NZS 4012 &
AS/NZS 4013.
2
1.2. FITTING REAR HEAT SHIELD
Before working out the posion of the heater and the relevant
clearances to combusble surfaces, t the rear outer heat
shield with the curved end at the top and spacers between
the inner heat shield:
1) On the rear of the heater, there are four 32mm long PK
screws xing the outer heat shield, upside-down, to the
inner heat shield. Remove the screws and the outer heat
shield.
2) Rotate the outer heat shield 180 degrees so that the
curved end is on top and angled towards the front of the
heater.
3) A plasc packet with four 20mm long tubular spacers will
be inside the heater. Re-locate the four 32mm long PK
screws through the original holes in the outer heat shield,
slide a spacer over each screw, and re-fasten to the inner
heat shield.
1.3. INSTALLING THE HEATER
1.3.1. Posioning the Heater
Review the necessary clearances specied in this secon
before considering where to posion the heater.
Also check the praccability of installing the ue system in
relaon to any obstrucng roof beams before posioning the
heater.
The clearance distances can only be reduced if the
surrounding walls are made of non-combusble material such
as stone, brick or concrete. If non-combusble material,
distance can be reduced to 100 mm. Alternavely, shielding of
the wall(s) can reduce clearances (refer to next secon for
more detail).
Clearances to combusble surfaces vary depending on the
type of ue shielding used.
1.3.2. Standard Installaon
Dimensions given in the table and image below represent the
minimum clearance (in millimetres) to combusble materials.
A = Side clearance
B = Rear clearance
C = Minimum oor protector depth from door opening

Termékspecifikációk

Márka: Nectre
Kategória: Fűtő
Modell: MK1 LE

Szüksége van segítségre?

Ha segítségre van szüksége Nectre MK1 LE, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Fűtő Nectre

Nectre

Nectre Form 2 Útmutató

13 Augusztus 2024
Nectre

Nectre MK3 Útmutató

13 Augusztus 2024
Nectre

Nectre MK2 LE Útmutató

13 Augusztus 2024
Nectre

Nectre N900 Útmutató

12 Augusztus 2024
Nectre

Nectre Inbuilt Útmutató

12 Augusztus 2024
Nectre

Nectre MK1 LE Útmutató

12 Augusztus 2024
Nectre

Nectre N60 Útmutató

11 Augusztus 2024

Útmutatók Fűtő

Legújabb útmutatók Fűtő