Használati útmutató Morco FEB-24E

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Morco FEB-24E (49 oldal) a Kazánok és kazánok kategóriában. Ezt az útmutatót 5 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/49
1
FEB-24E UK SUPERCOMPACT
COMBINATION BOILER
TECHNICAL & FAULTFINDING GUIDE
Morco Products Ltd
Riverview Road, Beverley, East Yorkshire, HU17 0LD
Telephone 01482 325456 Fax 01482 212869
2
Contents
1. Quick Guide to Trouble Shooting
2. Electrical Components
3. Central Heating Logic Programme
4. Explanation of Self Diagnostics
5. Self Diagnostic Flow Charts
ISSUE NUMBER 1.0
3
1. Quick Guide to Trouble shooting
This section outlines the most common problems and helps to guide you through the rest
of the workshop manual. (Read this section rst, before you make any adjustments. It
will save you time.)
CHECK HOT WATER SYSTEM FIRST, BEFORE THE CENTRAL HEATING CIRCUIT
HOT WATER SYSTEM
Here are some common problems:
GAS REGULATORS
Single appliance low capacity gas regulators plus 3/8” exible low pressure pipe, will
reduce the eciency dramatically. Ensure gas regulators and pipes are capable of
delivering 37mbar at the inlet under full load. A 2.5mbar drop is acceptable.
WATER FILTER
Check for contamination with foreign objects such as sawdust, plastic pipe swarf, etc. The
water lter is located inside the cold water inlet tting under the boiler. Any blockage will
reduce ow and may prevent the boiler ring up.
HOT AND COLD WATER CONNECTIONS
Connections may be reversed at the boiler inlet/outlet fittings, resulting in the boiler failing
to commence ignition sequence. This is because the hydraulic valve operates in one
direction only.
THERMOSTATIC SHOWER MIXER VALVE
Faulty non return valves within the mixer tap may allow mains cold water to enter the
domestic hot water pipe work. The boiler will react to the situation according to the
amount of mains water entering the system. In severe cases a high percentage of mains
cold water will exit the hot water tap in place of hot water, as water will always take the
path of least resistance. This will result in no hot water ow, or a very restricted flow
through the boiler. This will result in no ignition occurring or the boiler will modulate at very
low gas pressure, followed by the boiler eventually shutting down as insucient ow
passes through the boiler.

Termékspecifikációk

Márka: Morco
Kategória: Kazánok és kazánok
Modell: FEB-24E

Szüksége van segítségre?

Ha segítségre van szüksége Morco FEB-24E, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Kazánok és kazánok Morco

Morco

Morco G11E Útmutató

30 Szeptember 2024
Morco

Morco MP11 Útmutató

19 Augusztus 2024
Morco

Morco F-11 E L Útmutató

17 Augusztus 2024
Morco

Morco FEB-20E Útmutató

17 Augusztus 2024
Morco

Morco FEB-24ED3 Útmutató

16 Augusztus 2024
Morco

Morco FEB-24E Útmutató

16 Augusztus 2024
Morco

Morco EUP6 Útmutató

16 Augusztus 2024
Morco

Morco EUP11 Útmutató

15 Augusztus 2024

Útmutatók Kazánok és kazánok

Legújabb útmutatók Kazánok és kazánok