Air Conditioners
SLZ-KF25, KF35, KF50, KF60VA3
INSTALLATION MANUAL
For safe and correct use, please read this manual and the outdoor unit installation manual thoroughly before install-
ing the air-conditioner unit.
English
FOR INSTALLER
2
Contents
1. Safety precautions 2
.........................................................................................
2. Selecting the installation location 2
...................................................................
3. Installation diagram 3
........................................................................................
4. Installing the indoor unit 3
.................................................................................
5. Refrigerant piping work 5
..................................................................................
6. Drainage piping work 7
.....................................................................................
7. Electrical work 8
................................................................................................
8. Test run 15 ........................................................................................................
9. System control 17 .............................................................................................
10. Installing the grille 17 ........................................................................................
11. Easy maintenance function 20
..........................................................................
1. Safety precautions
• Besuretoread“Safetyprecautions”beforeinstallingtheairconditioner.
• Besuretoobservethecautionsspeciedhereastheyincludeimportant
itemsrelatedtosafety.
• Theindicationsandmeaningsareasfollows.
Warning:
Couldleadtodeath,seriousinjury,etc.
Caution:
Couldleadtoseriousinjuryinparticularenvironmentswhenoperatedincor-
rectly.
• Afterreadingthismanual,besuretokeepittogetherwiththeinstruction
manualinahandyplaceonthecustomer’ssite.
: Indicates a part which must be grounded.
Warning:
Carefullyreadthelabelsaffixedtothemainunit.
Installtheindoorunitatleast2.5mabovefloororgradelevel.
Forappliancesnotaccessibletothegeneralpublic.
Warning:
• Donotinstallitbyyourself(customer).
Incompleteinstallationcouldcauseinjuryduetore,electricshock,theunit
fallingorleakageofwater.Consultthedealerfromwhomyoupurchasedthe
unitorspecialinstaller.
• Installtheunitsecurelyinaplacewhichcanbeartheweightoftheunit.
When installed in an insufcient strong place, the unit could fall causing
injured.
• Usethespeciedwirestoconnecttheindoorandoutdoorunitssecurelyand
attachthewiresrmlytotheterminalboardconnectingsectionssothestress
ofthewiresisnotappliedtothesections.
Incompleteconnectingandxingcouldcausere.
• Donotuseintermediateconnectionofthepowercordortheextensioncord
anddonotconnectmanydevicestooneACoutlet.
Itcouldcauseareoranelectricshockduetodefectivecontact,defective
insulation,exceedingthepermissiblecurrent,etc.
• Checkthattherefrigerantgasdoesnotleakafterinstallationhascompleted.
• Performtheinstallationsecurelyreferringtotheinstallationmanual.
Incomplete installation could cause a personal injury due to re, electric
shock,theunitfallingorleakageofwater.
• Performelectricalworkaccordingtotheinstallationmanualandbesureto
useanexclusivecircuit.
Ifthecapacityofthepowercircuitisinsufcientorthereisincompleteelectri-
calwork,itcouldresultinareoranelectricshock.
• Theusershouldneverattempttorepairtheunitortransferittoanotherloca-
tion.
• Theapplianceshallbeinstalledinaccordancewithnationalwiringregula-
tions.
• Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,its
serviceagentorsimilarlyqualiedpersonsinordertoavoidahazard.
• Attachtheelectricalpartcovertotheindoorunitandtheservicepaneltothe
outdoorunitsecurely.
Iftheelectricalpartcoverintheindoorunitand/ortheservicepanelinthe
outdoorunitarenotattachedsecurely,itcouldresultinareoranelectric
shockduetodust,water,etc.
• Besuretousethepartprovidedorspeciedpartsfortheinstallationwork.
Theuseofdefectivepartscouldcauseaninjuryorleakageofwaterduetoa
re,anelectricshock,theunitfalling,etc.
• Ventilatetheroomifrefrigerantleaksduringoperation.
If the refrigerant comes in contact with a ame, poisonous gases will be
released.
• Wheninstallingorrelocating,orservicingtheairconditioner,useonlythe
speciedrefrigerant(R410A)tochargetherefrigerantlines.Donotmixitwith
anyotherrefrigerantanddonotallowairtoremaininthelines.
Ifairismixedwiththerefrigerant,thenitcanbethecauseofabnormalhigh
pressure in the refrigerant line,and may result in an explosion and other
hazards.
Theuseofanyrefrigerantotherthanthatspeciedforthesystemwillcause
mechanical failure or system malfunction or unit breakdown. In the worst
case,thiscouldleadtoaseriousimpedimenttosecuringproductsafety.
Caution:
• Performgrounding.
Donotconnectthegroundwiretoagaspipe,waterpipearresterortelephone
groundwire.Defectivegroundingcouldcauseanelectricshock.
• Donotinstalltheunitinaplacewhereaninammablegasleaks.
Ifgasleaksandaccumulatesintheareasurroundingtheunit,itcouldcause
anexplosion.
• Installagroundleakagebreakerdependingontheinstallationplace(where
itishumid).
If a ground leakage breaker is not installed, it could cause an electric
shock.
• Perform the drainage/piping work securely according to the installation
manual.
Ifthereisadefectinthedrainage/pipingwork,watercoulddropfromtheunit
andhouseholdgoodscouldbewetanddamaged.
• Fastenaarenutwithatorquewrenchasspeciedinthismanual.
Whenfastenedtootight,aarenutmaybrokenafteralongperiodandcause
aleakageofrefrigerant.
• Iftheunitisrunforlonghourswhentheairabovetheceilingisathightem-
perature/highhumidity(dewpointabove26ºC),dewcondensationmaybe
producedintheindoorunitortheceilingmaterials.Whenoperatingtheunits
inthiscondition,addinsulationmaterial(10-20mm)totheentiresurfaceof
theunitandceilingmaterialstoavoiddewcondensation.
2. Selectingtheinstallationlocation
2.1. Indoorunit
• Whereairowisnotblocked.
• Wherecoolairspreadsovertheentireroom.
• Whereitisnotexposedtodirectsunshine.
• Atadistance1mormoreawayfromyourTVandradio(topreventpicturefrom
being distorted or noise from being generated).
• Inaplaceasfarawayaspossiblefromuorescentandincandescentlights(sothe
infrared remote control can operate the air conditioner normally).
• Wheretheairltercanberemovedandreplacedeasily.
Warning:
Mounttheindoorunitintoaceilingstrongenoughtowithstandtheweightof
theunit.
2.2.
Wirelessremotecontrollermounting(ForSLP-2FAL*)
• Placeofmounting
• Whereitiseasytooperateandeasilyvisible.
• Wherechildrencannottouch.
• Mounting
Selectapositionabout1.2mabovetheoor,checkthatsignalsfromtheremote
controlleraresurelyreceivedbytheindoorunitfromthatposition(‘beep’or‘beep-
beep’receivingtonesounds).Afterthat,attachremotecontrollerholdertoapillar
or wall and set the wireless remote controller.
In rooms where inverter type uorescent lamps are used, the signal from the
wirelessremotecontrollermaynotbereceived.
Note:
Thephrase“Wiredremotecontroller”inthisinstallationmanualrefersonlytothePAR-33MAA.Ifyouneedanyinformationfortheotherremotecontroller,
pleaserefertoeithertheinstallationmanualorinitialsettingmanualwhichareincludedintheseboxes.
3
(576) C
(576) C
J
625 D
408
88 525 B
570 A
150
313
576 - 610 C
408
576 - 610 C
625 D
I
570 A
525 B
481
208
245
127
18952
50 - 92
10
*1
37 +5
0
K
FEG
3. Installationdiagram
3.1. Indoorunit(Fig.3-1)
A Ceiling
B Grille
C Obstacle
D Min.1000mm
E Min.500mm(Entireperiphery)
If setting the maintenance space for E,besuretoleaveisaminimumof700mm.
Warning:
Mounttheindoorunitonaceilingstrongenoughtowithstandtheweightof
theunit.
3.2. Outdoorunit
Refer to the outdoor unit installation manual.
(mm)
Fig.3-1
Fig.4-1
4. Installingtheindoorunit
4.2. Ceilingopeningsandsuspensionboltinstallation
locations(Fig.4-2)
Caution:
Installtheindoorunitatleast2.5maboveoororgradelevel.
Forappliancesnotaccessibletothegeneralpublic.
• Usingtheinstallationtemplateandthegauge(suppliedasanaccessorywiththe
grille),makeanopeningintheceilingsothatthemainunitcanbeinstalledasshown
inthediagram.(Themethodforusingthetemplateandthegaugeareshown.)
* Before using, check the dimensionsof template and gauge, because they
changeduetouctuationsoftemperatureandhumidity.
* The dimensions of ceiling opening can be regulated within the range shown in
followingdiagram;socenterthemainunitagainsttheopeningofceiling,en-
suringthattherespectiveoppositesidesonallsidesoftheclearancebetween
them becomes identical.
• UseM10(3/8")suspensionbolts.
*Suspensionboltsaretobeprocuredattheeld.
• Installsecurely,ensuringthatthereisno clearancebetween theceiling panel&
grille,andbetweenthemainunit&grille.
A Outer side of main unit
B Bolt pitch
C Ceiling opening
D Outer side of Grille
E Grille
F Ceiling
G Min.500mm(Entireperiphery)
If setting the maintenance space for G,be
suretoleaveisaminimumof700mm.
H Maintenancespace
I Fresh air intake
J Angle
K Electriccomponentbox
* Leavethemaintenancespaceattheelectriccomponentboxend.
*1When installing inan existingceiling unitlocation or applyingadditional heatinsulation,
ensure a minimum space of 25 mm.
Fig.4-2
(mm)
24510
625
625
C
D
E
A
B
1 2
34
5 6
4.1. Checktheindoorunitaccessories(Fig.4-1)
The indoor unit should be supplied with the following accessories.
Accessoryname Q’ty
1 Installation template 1
2Washers(withinsulation)
Washers(withoutinsulation)
4
4
3
Pipecover(forrefrigerantpipingjoint)
smalldiameter(liquid)
largediameter(gas)
1
1
4
Band(large)
Band(middle)
Band(small)
6
2
2
5 Drain socket 1
6 Insulation 1
7.5-24.57.5-24.5
Min.450H
Floor
7.5-24.57.5-24.5
Min.5
Min.2500
Min.450H
Termékspecifikációk
Márka: | Mitsubishi |
Kategória: | Airco |
Modell: | SLZ-KF60VAD |
Szüksége van segítségre?
Ha segítségre van szüksége Mitsubishi SLZ-KF60VAD, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Airco Mitsubishi
14 Október 2024
9 Október 2024
9 Október 2024
8 Október 2024
4 Október 2024
2 Október 2024
1 Október 2024
30 Szeptember 2024
29 Szeptember 2024
23 Szeptember 2024
Útmutatók Airco
- Airco Mestic
- Airco Samsung
- Airco Beko
- Airco Fujitsu
- Airco Dometic
- Airco Electrolux
- Airco Whirlpool
- Airco Nedis
- Airco LG
- Airco Grundig
- Airco Ariston Thermo
- Airco Candy
- Airco Gorenje
- Airco Princess
- Airco Oregon Scientific
- Airco Bosch
- Airco NewAir
- Airco Panasonic
- Airco MPM
- Airco AEG
- Airco Emerio
- Airco Sharp
- Airco Einhell
- Airco Toshiba
- Airco Ozito
- Airco Hyundai
- Airco Hisense
- Airco HQ
- Airco Siemens
- Airco Medion
- Airco Exquisit
- Airco Corbero
- Airco Camry
- Airco TCL
- Airco Danby
- Airco DeLonghi
- Airco Insignia
- Airco Heinner
- Airco Infiniton
- Airco Wilfa
- Airco Klarstein
- Airco VOX
- Airco Be Cool
- Airco Tripp Lite
- Airco Vivax
- Airco Thomson
- Airco Fuave
- Airco Ardes
- Airco Orima
- Airco Eden
- Airco Bimar
- Airco Clatronic
- Airco Bomann
- Airco Amana
- Airco Hotpoint
- Airco Haier
- Airco Frigidaire
- Airco Cecotec
- Airco Sencor
- Airco Qlima
- Airco Baxi
- Airco Innoliving
- Airco Avidsen
- Airco Rowenta
- Airco Westinghouse
- Airco Hitachi
- Airco BLUEPALM
- Airco Telefunken
- Airco GoldAir
- Airco Domo
- Airco Russell Hobbs
- Airco SHE
- Airco Create
- Airco Black & Decker
- Airco Wood's
- Airco Vaillant
- Airco Livington
- Airco Orbegozo
- Airco Daewoo
- Airco Livoo
- Airco ARGO
- Airco GE
- Airco Guzzanti
- Airco Concept
- Airco Whynter
- Airco SVAN
- Airco Keystone
- Airco Consul
- Airco TriStar
- Airco Suntec
- Airco APC
- Airco Daizuki
- Airco Daikin
- Airco Midea
- Airco Electroline
- Airco Kogan
- Airco Profilo
- Airco Honeywell
- Airco Truma
- Airco Stirling
- Airco Furrion
- Airco Dimplex
- Airco Master
- Airco Aspes
- Airco Kenmore
- Airco Thermex
- Airco Trotec
- Airco Manta
- Airco Blaupunkt
- Airco HTW
- Airco Korona
- Airco Comfee
- Airco Be Quiet!
- Airco Finlux
- Airco Gree
- Airco AKAI
- Airco Emerson
- Airco Kalorik
- Airco Sanyo
- Airco Philco
- Airco ECG
- Airco Esatto
- Airco Element
- Airco Friedrich
- Airco Rinnai
- Airco Argoclima
- Airco RCA
- Airco SereneLife
- Airco Carrier
- Airco Becken
- Airco OneConcept
- Airco Olimpia Splendid
- Airco ActronAir
- Airco Mistral
- Airco Orava
- Airco Eurom
- Airco Sauber
- Airco IFB
- Airco Sonnenkönig
- Airco Tectro
- Airco Zibro
- Airco Airwell
- Airco Amcor
- Airco Calor
- Airco Mabe
- Airco Anslut
- Airco Termozeta
- Airco Eldom
- Airco Jocca
- Airco Nabo
- Airco White Knight
- Airco Profile
- Airco Evolar
- Airco Elba
- Airco Proline
- Airco Royal Sovereign
- Airco Kelvinator
- Airco Everglades
- Airco Heylo
- Airco ElectriQ
- Airco Daitsu
- Airco Milectric
- Airco Saunier Duval
- Airco Duux
- Airco Alpatec
- Airco Primo
- Airco Godrej
- Airco Maiko
- Airco Waeco
- Airco Essentiel B
- Airco Team
- Airco Edgestar
- Airco Maxicool
- Airco KDK
- Airco Carrefour Home
- Airco Equator
- Airco Kunft
- Airco Proklima
- Airco Home Electric
- Airco Eco-De
- Airco REMKO
- Airco Just Fire
- Airco Teco
- Airco Chigo
- Airco Hokkaido
- Airco Gutfels
- Airco Holland Electro
- Airco Elgin
- Airco Fronius
- Airco D-Let
- Airco Braemar
- Airco Klimaire
- Airco Duracraft
- Airco SEEGER
- Airco Khind
- Airco LERAN
- Airco General Electric
- Airco SPT
- Airco Fuji Electric
- Airco Polocool
- Airco Convair
- Airco Fral
- Airco Prem-i-air
- Airco Arcoaire
- Airco Bodin
- Airco MRCOOL
- Airco Monzana
- Airco Trilec
- Airco Kaden
- Airco TURBRO
- Airco Bonaire
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Big Ass Fans
- Airco Artrom
- Airco Commercial Cool
- Airco Riffel
- Airco Heat Controller
- Airco Luma Comfort
- Airco Norpole
- Airco Kaco
- Airco Omega Altise
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco KuulAire
- Airco Cool-Space
- Airco Aconatic
- Airco AireMax
- Airco VänEE
- Airco Mayer
- Airco Perfect Aire
- Airco Koldfront
Legújabb útmutatók Airco
16 Október 2024
16 Október 2024
16 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024