Használati útmutató Lavorwash PT70-SS Plus

Lavorwash Fűtő PT70-SS Plus

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Lavorwash PT70-SS Plus (20 oldal) a Fűtő kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/20
PT70-SS Plus / PT-125 SS
Users Manual &
Operating Instructions
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
LWRG-400
GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
WITHOUT ADEQUATE VENTILATION. TO BE USED IN WELL VENTILATED
COMMERCIAL / INDUSTRIAL OCCUPANCIES. This is an unvented portable heater that uses
air (Oxygen) from within the area in which it is used. Failure to provide adequate combustion and
ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to
“Ventilation” on Page 7.
DANGER
This appliance shall be installed in accordance with the rules in force,
and used only in sufficiently ventilated space. Consult instructions before
installation and use of this appliance.
WARNING
DIESEL FIRED RADIANT HEATER
ORIGINAL INSTRUCTIONS
© 2020 Lavorwash Australia Pty Ltd
7/76 Rushdale Street, Knoxfield, Vic. 3180
PT70-SS Plus PT-125 SS
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
CONNECTED TO A POWER SOURCE
Diesel Fired Radiant Heater User’s Manual
© 2020, Lavorwash 1
Table Of Contents
Safety Information 1-2 ...........................................
Features and Specications ............................... 3
PT70-SS Plus Assembly..................................... 4
PT-125 SS Assembly ....................................... 5-6
Ventilation 7 ...........................................................
Operation 7-8 .........................................................
Maintenance 9-12 ..................................................
Troubleshooting Guide 13 .....................................
Wiring Diagram 14 .................................................
Exploded View 15, 17 ............................................
Parts List................................................ 15-16, 18
Safety Information
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such
as; building materials, paper or cardboard a safe distance away from the heater
as recommended by these instructions. Never use the heater in spaces which contain products
such as; gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles or any
unknown chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in
which it is used. Adequate combustion and ventilation air must be provided. Refer to “Ventilation
on page 7. Bulk fuel storage should be a minimum of 25 feet from heater.
WARNING
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this heater can result in death,
serious bodily injury, property loss or damage from the hazards of fire, soot production, explosions,
burns, asphyxiation or carbon monoxide poisoning. Only persons who can read and understand
these instructions should use or service this heater.
WARNING
Look for this icon throughout the manual for helpful tips on how to
assemble, use and clean your SS Heater.
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
WARNING
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING
THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE
AUTHORITIES HAVING JURISDICTION.
Read The Instruction manual: When this symbol is
marked on a product, it means that the instruction
manual must be read.
WARNING! Never touch heater until heater
has cooled off.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience or and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
CONNECTED TO A POWER SOURCE
Diesel Fired Radiant Heater User’s Manual
© 2020, Lavorwash 2
Safety Information
The products described in this manual are
Parafn/Diesel direct-red, forced air heaters.
Parafn/Diesel forced air heaters are primarily
intended for use for temporary heating of
buildings under construction, alteration or repair.
Direct-red means that all of the combustion
products of the heater enter the heated space.
This appliance is rated at 98% combustion
efciency, but does produce small amounts of
carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this manual
can result in death.
People with breathing problems should consult a
physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the u. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea Dry Mouth
Sore Throat Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide
than others. These include: pregnant women,
those with heart or lung problems, anemia or those
under the influence of alcohol or at high altitudes.
Use this heater in only well ventilated areas!
Provide at least a three square foot
(2,800 cm2) opening of outside air for every
29 kW / Hr heater rating. Refer to “Ventilation”
on page 7 for further instructions.
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only properly grounded socket and
properly rated extension cables.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
If the supply cord is damaged, it must be
replaced by a special cord or assemble available
from the manufacturer, its service agent or
similarly qualied persons in order to avoid a
hazard
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the
heater is operating or still hot. This heater is
EXTREMELY HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
PT70-SS Plus PT-125 SS
Top 1.2 m 1.2 m
Sides 1.2 m 1.2 m
Front 2.4 m 2.4 m
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat,
once it is plugged in, it can start at anytime in
accordance with the thermostat setting.
RISK OF INDOOR AIR
POLLUTION!
WARNING
CARBON MONOXIDE POISONING
MAY LEAD TO DEATH!
WARNING
RISK OF BURNS, FIRE AND
EXPLOSION!
WARNING
RISK OF ELECTRIC SHOCK!
WARNING
CAUTION! HOT WHILE IN
OPERATION. DO NOT TOUCH.
KEEP CHILDREN, ANIMALS, CLOTHING AND
COMBUSTIBLES AWAY FROM HEATER.
WARNING

Termékspecifikációk

Márka: Lavorwash
Kategória: Fűtő
Modell: PT70-SS Plus

Szüksége van segítségre?

Ha segítségre van szüksége Lavorwash PT70-SS Plus, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek