M O U N T I N G A N D C O N N E C T I N G T H E D E V I C E
T E C H N I C A L D E T A I L S
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. 14 W
Environment Temperature range 0–35 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; mea-
sures 210 x 45 x 140 mm (W x H x D)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
WAN: VDSL2 aVDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b
aVDSL Supervectoring as per ITU G.993.2 (Annex Q)
aVDSL2 vectoring as per ITU G.993.5 (G.Vector)
aCompatible to VDSL2 from Deutsche Telekom
aCompatible to U-R2 from Deutsche Telekom (1TR112)
aADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1
aADSL2+ over POTS as per ITU G.992.5 Annex A/M with DPBO, ITU G.992.3, and ITU.G.992.1
aSupports just one virtual connection at a time in ATM (VPI-VCI pair)
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS configuration.
USB USB 2.0 hi-speed host port
Config (Com) / V.24 Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for
optional connection of analog/GPRS modems. Supports internal COM-port server and provides
transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN
Declaration of Conformity
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in
compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of
the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc
Package content
Documentation Quick Reference Guide (DE/EN); Installation Guide (DE/EN)
Cable 1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m
Power adapter External power supply adapter 12 V / 2 A DC/S; barrel / bayonet (EU),
LANCOM item no. 111303 (not for WW devices)
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device‘s
WEBconfig interface under “Extras > License information“. If the respective license demands, the source files for the
corresponding software components will be made available on a download server upon request.
e VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, flashing VPN connecting
b Online
Off WAN connection inactive
Green, blinking WAN connection is established
(e.g. PPP negotiation)
Green, permanently WAN connection active
Red, permanently WAN connection error
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, flickering DSL data transfer
Red, flickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d ETH
Off No networking device attached
Green, permanently Connection to network device operational,
no data traffic
Green, flickering Data transmission
f Reset
Reset button Operated e.g. with a paper clip
ashort press: Restart the device
along press: Reset the device
a Power
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Red / green blinking Configuration password not set. Without a
configuration password, the configuration
data in the device is unprotected.
Red blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
4
Please observe the following when setting up the device
A Do not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the adhesive rubber footpads
AIn case of wall mounting, use the drilling template as supplied
AKeep the ventilation slots of the device clear of obstruction
ARack installation with the optional LANCOM Rack Mount (separately available)
aVDSL / ADSL interface
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
bEthernet interfaces
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
cConfiguration interface
Use a serial configuration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
configuring / monitoring (separately available).
dUSB interface
Connect compatible USB devices either directly to the USB
interface, or use a suitable USB cable.
ePower
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
a cb d e f
LANCOM 1790VA
LANCOM 1790VA
Quick Reference Guide
C ud eadylo -r
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is configured to be managed by the LANCOM
Management Cloud.
a b c d e
Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.
LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This docu-
ment contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions. 111780/01/22

Termékspecifikációk

Márka: Lancom
Kategória: router
Modell: 1790VA

Szüksége van segítségre?

Ha segítségre van szüksége Lancom 1790VA, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók router Lancom

Lancom

Lancom 1800EF-4G Útmutató

1 Szeptember 2024
Lancom

Lancom 1803VAW Útmutató

29 Augusztus 2024
Lancom

Lancom 1800VA-5G Útmutató

29 Augusztus 2024
Lancom

Lancom 1803VA-5G Útmutató

29 Augusztus 2024
Lancom

Lancom 1781VA-4G Útmutató

28 Augusztus 2024
Lancom

Lancom 1722 VoIP Útmutató

13 Augusztus 2024
Lancom

Lancom 1781EF Útmutató

13 Augusztus 2024
Lancom

Lancom 1790VA Útmutató

12 Augusztus 2024
Lancom

Lancom OAP-382 Útmutató

4 Augusztus 2024

Útmutatók router

Legújabb útmutatók router