Használati útmutató JANDY Stealth
Olvassa el alább 📖 a magyar nyelvű használati útmutatót JANDY Stealth (60 oldal) a Pompa kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/60
Jandy Stealth™ Pumps
Models SHPF and SHPM
H0573800 Rev V
ENGLISH | FRANÇAIS | ESPAÑOL
INSTALLATION AND
OPERATION MANUAL
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Table of Contents
Section 1. IMPORTANT SAFETY
INSTRUCTIONS 3 ..............................
1.1 Safety Instructions 3 ............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 5 ........................................................
Section 2. General Description 6 ......................
2.1 Introduction ....................................................... 6
2.2 Description ....................................................... 6
Section 3. Installation 6 ......................................
3.1 Plumbing .......................................................... 6
3.2 Electrical Installation 8 .........................................
3.3 Pressure Testing ............................................. 10
Section 4. Operation 12 ......................................
4.1 Start-up ........................................................... 12
Section 5. Service and Maintenance 13 ............
5.1 Routine Maintenance 13 .....................................
5.2 Winterizing the Pump 13 .....................................
Section 6. Troubleshooting 14 ..........................
6.1 Troubleshooting .............................................. 14
Section 7. Product Specications and
Technical Data 15 .............................
7.1 Replacement Parts List 15 ..................................
7.2 Exploded View 16 ................................................
7.3 SHPF and SHPM Pump Curves 17 .....................
7.4 PhysicalandOperationalSpecications ........ 17
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
NOTES:
EQUIPMENT INFORMATION RECORD
Page 2 ENGLISH
Jandy® Stealth™ Pumps | Operation Manual
Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
Page 3
ENGLISH
Jandy® Stealth™ Pumps | Operation Manual
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full
ow)valvepositionwiththepumprunning.
WARNING
Jandypumpsarepoweredbyahighvoltageelectricmotorandmustbeinstalledbyalicensedorcertiedelec-
tricianoraqualiedswimmingpoolservicetechnician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH (For all permanently installed units
intended for use on 15 or 20 ampere, 120 through 240 volt, single phase branch circuits). Connect only
toabranchcircuitthatisprotectedbyaground-faultcircuit-interrupter(GFCI).Contactaqualiedelectricianif
you cannot verify that the circuit is protected by a GFCI. A GFCI should be provided by the installer and should
be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the
reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCIinterruptspowertothepumpwithoutthetestbuttonbeingpushed,agroundcurrentisowing,indicating
the possibility of electrical shock. Do not use the pump. Disconnect the pump and have the problem corrected by
aqualiedservicerepresentativebeforeusing.
Duetothepotentialriskofre,electricshock,orinjuriestopersons,JandyPumpsmustbeinstalledinaccor-
dance with the National Electrical Code® (NEC®),alllocalelectricalandsafetycodes,andtheOccupationalSafe-
ty and Health Act (OSHA®).CopiesoftheNECmaybeorderedfromtheNationalFireProtectionAssociation ®
(NFPA®)onlineatwww.nfpa.orgorcall617-770-3000,orcontactyourlocalgovernmentinspectionagency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trappedairinsystemcancausethelterlidtobeblownoff,whichcanresultindeath,seriouspersonalinjury,
or property damage. Be sure all air is out of the system before operating.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suctionoutlets.Suctionoutlet(drain)assembliesandcoversmustbecertifiedtothelatestpublishedversionof
ANSI®/ASME® A112.19.8, or its successor standard, ANSI/APSP-16.
Termékspecifikációk
Márka: | JANDY |
Kategória: | Pompa |
Modell: | Stealth |
Szüksége van segítségre?
Ha segítségre van szüksége JANDY Stealth, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Pompa JANDY
12 Január 2025
19 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
18 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
16 Augusztus 2024
16 Augusztus 2024
Útmutatók Pompa
- Pompa Milwaukee
- Pompa Husqvarna
- Pompa Kärcher
- Pompa SilverCrest
- Pompa Ultimate Speed
- Pompa Einhell
- Pompa Ozito
- Pompa Bartscher
- Pompa Hyundai
- Pompa Bestway
- Pompa Fuxtec
- Pompa AL-KO
- Pompa Crivit
- Pompa Scheppach
- Pompa Ergotools Pattfield
- Pompa Technaxx
- Pompa Lezyne
- Pompa Güde
- Pompa Toolcraft
- Pompa Gardena
- Pompa Vaillant
- Pompa Fieldmann
- Pompa PowerPlus
- Pompa Metabo
- Pompa Osram
- Pompa Testo
- Pompa Simpson
- Pompa Powerfix
- Pompa Biltema
- Pompa Zodiac
- Pompa RYOBI
- Pompa Gardenline
- Pompa OKAY
- Pompa Hayward
- Pompa AstralPool
- Pompa Hozelock
- Pompa Fluke
- Pompa Zipper
- Pompa Fiap
- Pompa Polaris
- Pompa Waldbeck
- Pompa Eheim
- Pompa Danfoss
- Pompa Neptun
- Pompa Vonroc
- Pompa Oase
- Pompa Panduit
- Pompa Outwell
- Pompa Melinera
- Pompa Alpha Tools
- Pompa Pontec
- Pompa Lavorwash
- Pompa Eurom
- Pompa Topeak
- Pompa Blackburn
- Pompa Enermax
- Pompa Fluval
- Pompa Grundfos
- Pompa Hazet
- Pompa Generac
- Pompa Nefit
- Pompa Quigg
- Pompa Sicce
- Pompa Sun Joe
- Pompa Tacklife
- Pompa SKS
- Pompa Nibe
- Pompa Ferroli
- Pompa Sanibroyeur
- Pompa Michelin
- Pompa Bulex
- Pompa Blumfeldt
- Pompa For_Q
- Pompa WHALE
- Pompa Abac
- Pompa Cannondale
- Pompa Coleman
- Pompa Maruyama
- Pompa Jabsco
- Pompa Eufab
- Pompa Aerotec
- Pompa Batavia
- Pompa Westfalia
- Pompa ESPA
- Pompa Pedrollo
- Pompa Velda
- Pompa Vivaria
- Pompa Plantiflor
- Pompa Verto
- Pompa Wetelux
- Pompa Germania
- Pompa Little Giant
- Pompa Anova
- Pompa Ubbink
- Pompa DAB
- Pompa Esotec
- Pompa Wayne
- Pompa T.I.P.
- Pompa Rule
- Pompa Elpumps
- Pompa Hollex
- Pompa B-Air
- Pompa Baracuda
- Pompa Lifan
- Pompa Monzana
- Pompa Liberty Pumps
- Pompa BluGarda
- Pompa Madimack
- Pompa Sauermann
- Pompa Eco-Flo
- Pompa Nowax
- Pompa Zoeller
- Pompa Superior Pump
- Pompa SHURflo
- Pompa EvoHeat
- Pompa MSW
- Pompa Barwig
- Pompa Ebara
- Pompa Perlick
- Pompa Basement Watchdog
- Pompa Zéfal
- Pompa Zehnder Pumpen
- Pompa Comet
- Pompa SANDPIPER
- Pompa Heissner
- Pompa OSIP
- Pompa Franklin Electric
Legújabb útmutatók Pompa
12 Január 2025
12 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
5 Január 2025
5 Január 2025
5 Január 2025
3 Január 2025
2 Január 2025