Intel® Entry Server Chassis SC5299-E
DP/WS/BRP User Guide
A Guide for Technically Qualified Assemblers of Intel
® Identified Subassemblies/Products
Intel Order Number D37596-002
ii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Disclaimer
Information in this document is provided in connection with Intel® products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel® products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation where
personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time,
without notice.
Intel® server boards contain a number of high-density VLSI and power delivery components that need adequate
airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the system integrator that
chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of airflow required for their specific application and environmental conditions. Intel
Corporation can not be held responsible if components fail or the server board does not operate correctly when used
outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
* Other names and brands may be claimed as the property of others.
Copyright © 2006, Intel Corporation. All Rights Reserved
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide iii
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the
instructions. See also Intel Server Boards and Server Chassis Safety Information on the
Intel® Server Deployment Toolkit CD and/or at http://support.intel.com/support/
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
Intel-Serverplatinen und Servergehäusen auf der Intel® Server Deployment Toolkit CD
oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
document avant de suivre toute instruction. Consultez Intel Server Boards and Server
Chassis Safety Information sur le Intel® Server Deployment Toolkit CD ou bien rendez-
vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety
Information en el Intel® Server Deployment Toolkit CD y/o en http://support.intel.com/
support/motherboards/server/sb/cs-010770.htm.
重要安全指导
Safety Information
iv Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Warnings
Heed safety instructions: Before working with your server product, whether you are
using this guide or any other resource as a reference, pay close attention to the safety
instructions. You must adhere to the assembly instructions in this guide to ensure and
maintain compliance with existing product certifications and approvals. Use only the
described, regulated components specified in this guide. Use of other products /
components will void the UL listing and other regulatory approvals of the product and
will most likely result in noncompliance with product regulations in the region(s) in which
the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To
remove power from system, you must unplug the AC power cord from the wall outlet.
Make sure the AC power cord is unplugged before you open the chassis, add, or remove
any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the server and
disconnect the power cord, telecommunications systems, networks, and modems attached
to the server before opening it. Otherwise, personal injury or equipment damage can
result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
boards, and other parts. We recommend that you perform all procedures in this chapter
only at an ESD workstation. If one is not available, provide some ESD protection by
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to ESD. Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded,
static free surface. Use a conductive foam pad if available but not the board wrapper. Do
not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that you can grip with your
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a
tab, take care when using needle nosed pliers to remove or install a jumper; grip the
narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides
can damage the contacts inside the jumper, causing intermittent problems with the
function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or
other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide v
Preface
About this Manual
Thank you for purchasing and using the Intel® Entry Server Chassis SC5299-E.
This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server chassis. This document provides a brief overview of
the features of the chassis, a list of accessories or other components you may need,
troubleshooting information, and instructions on how to add and replace components on
the Intel® Entry Server Chassis SC5299-E. For the latest version of this manual, see http:/
/support.intel.com/support/motherboards/server/chassis/sc5299-e/.
Manual Organization
Chapter 1 provides a brief overview of the Intel® Entry Server Chassis SC5299-E. In this
chapter, you will find a list of the server chassis features, photos of the product, and
product diagrams to help you identify components and their locations.
Chapter 2 provides instructions on adding and replacing components. Use this chapter for
step-by-step instructions and diagrams for installing or replacing components such as the
fans, power supply, drives, and other components.
At the back of this book, you will find technical specifications, regulatory information,
"getting help" information, and the warranty.
Product Contents, Order Options, and Accessories
This server chassis is compatible with the following Intel® Server Boards:
Intel® Server Board S5000XVN
Intel® Server Board S5000VSA
Intel® Server Board S5000PSL
Intel® Server Board S5000XSL
Your Intel® Entry Server Chassis SC5299-E ships with the following items:
A power factor correction (PFC) power supply, installed in the chassis. Wattage of
power supply will depend on the model of server chassis you purchased. Three power
supply configurations are available.
A box of hardware components, referred to below as the "hardware kit"
Fan cable, installed in the chassis
Preface
vi Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Chassis intrusion switch, installed in the chassis
Front panel, installed in the chassis
Attention document, in the chassis product box
Intel® Entry Server Chassis SC5299-E Quick Start User's Guide, in the chassis
product box
Four M3 screws for installing 5.25-in drive component, in the hardware kit
Fifteen 6-32 screws for mounting the server board to the chassis, in the hardware kit
USB cable
In addition, you may need or want to purchase one or more of the following accessory
items for your server:
Processor, memory FBDIMMs, hard drive, CD-ROM or DVD-ROM drive, RAID
controller, operating system.
For information about which accessories, memory, processors, and third-party hardware
have been tested and can be used with your server board, and for ordering information for
Intel® products, see http://support.intel.com/support/motherboards/server/chassis/sc5299-
e/compat.htm.
Additional Information and Software
If you need more information about this product or information about the accessories that
can be used with this server chassis, use the following resources. These files are available
at http://support.intel.com/support/motherboards/server/chassis/sc5299-e/
Unless otherwise indicated in the following table, once on this Web page, type the
document or software name in the search field at the left side of the screen and select the
option to search "This Product."
For this information or
software Use this Document or Software
For in-depth technical
information about this
product, including
dimensions and power
characteristics
Intel® Entry Server Chassis SC5299-E Technical Product
Specification
If you just received this
product and need to install
it
Intel® Entry Server Chassis SC5299-E Quick Start User's Guide in
the product box
For virtual system tours
and interactive repair
information
A link to the SMaRT Tool is available under "Other Resources" at the
right side of the screen at
http://support.intel.com/support/motherboards/server/chassis/
sc5299-e
Accessories or other Intel
server products
Spares and Configuration Guide
Preface
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide vii
Hardware (peripheral
boards, adapter cards) and
operating systems that
have been tested with this
product
Tested Hardware/Operating Systems List
To make sure your system
falls within the allowed
power budget
Power Budget Tool at
http://support.intel.com/support/motherboards/server/chassis/
sc5299-e
For software to manage
your Intel® server
Intel® System Management Software
For this information or
software Use this Document or Software
Preface
viii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide ix
Contents
Safety Information .......................... ................................................. .......................... iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Warnings ............................................................................................................................... iv
Preface ............................... .............................................. ............................................ v
About this Manual .................................................................................................................. v
Manual Organization .............................................................................................................. v
Product Contents, Order Options, and Accessories .............................................................. v
Additional Information and Software ..................................................................................... vi
Server Chassis Features .............................. ................................. ............................. 1
Component Identification .......................................................................................................3
Front View Components ................................................................................................3
Internal Components ..................................................................................................... 5
Back Panel Components ............................................................................................... 6
Front Panel ....................................................................................................................7
Peripheral Devices .................................................................................................................8
Hard Disk Drives ............................................................................................................8
Front Bezel Assembly ............................................................................................................9
Rack-Mounted Systems .........................................................................................................9
Mechanical Locks ................................................................................................................10
Accessories and Order Codes .............................................................................................10
Hardware Installations and Upgrades ....................................................................11
Before You Begin .................................................................................................................11
Tools and Supplies Needed ........................................................................................11
System References .....................................................................................................11
Removing and Installing the Left Side Cover .......................................................................11
Removing the Left Side Cover .....................................................................................11
Installing the Left Side Cover .......................................................................................12
Removing and Installing the Front Bezel Assembly ............................................................13
Removing the Front Bezel Assembly ..........................................................................13
Installing the Front Bezel Assembly ............................................................................14
Removing and Installing the Processor Air Duct .................................................................15
Removing the Processor Air Duct ...............................................................................15
Installing the Processor Air Duct .................................................................................15
Installing or Removing a Server Board ................................................................................16
Installing and Removing a Fixed Hard Drive .......................................................................22
Installing a Fixed Hard Drive .......................................................................................22
Removing a Fixed Hard Drive .....................................................................................28
Installing or Removing a DVD-ROM or CD-ROM Drive .......................................................31
Installing a DVD-ROM or CD-ROM Drive ....................................................................31
xIntel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Removing a CD-ROM or DVD-ROM Drive ................................................................. 33
Installing the Removing PCI Add-in Boards ........................................................................ 34
Installing PCI Add-in Boards ....................................................................................... 34
Removing PCI Add-in Boards ..................................................................................... 36
Replacing the Front Panel Board ........................................................................................ 38
Replacing a System Fan ..................................................................................................... 42
Replacing a Fixed Power Supply ........................................................................................ 44
Installing an Additional Hot Swap Power Supply Module (BRP configuration only) ............ 47
Replacing a Hot Swap Power Supply (BRP configuration only) .......................................... 48
Replacing a Hot Swap Power Supply Cage (BRP configuration only) ................................ 49
Installing Feet for a Pedestal-configured Chassis ............................................................... 54
Hot Swap Drive Cage Upgrade Install Instructions (optional) ..............................55
Before You Begin ................................................................................................................ 55
Kits Required ............................................................................................................... 55
Tools and Supplies Needed ........................................................................................ 55
System References ..................................................................................................... 55
Installing a Hot Swap Hard Drive Cage with a SAS/SATA or SCSI Backplane .................. 56
Installing a Hot Swap Hard Drive ........................................................................................ 67
Rack Mount Kit Install Instructions (optional) ............... ............................. ...........75
Before You Begin ................................................................................................................ 75
Tools and Supplies Needed ........................................................................................ 75
System References ..................................................................................................... 75
Setting up a Rack-configured Chassis ................................................................................ 75
Technical Reference .................................................................................................87
Cable Routing ...................................................................................................................... 87
Power Supply Specifications ............................................................................................... 87
550-W Single Power Supply Input Voltages ............................................................... 87
550-W Single Power Supply Output Current ............................................................... 87
670-W Single Power Supply Input Voltages ............................................................... 88
670-W Single Power Supply Output Voltages ............................................................. 88
650-W Single Power Supply Input Voltages ............................................................... 88
650-W Single Power Supply Output Voltages ............................................................. 88
System Environmental Specifications ................................................................................. 89
A. Safety Information ................................................................................................91
English ................................................................................................................................. 91
Server Safety Information ........................................................................................... 91
Safety Warnings and Cautions .................................................................................... 91
Intended Application Uses .......................................................................................... 92
Site Selection .............................................................................................................. 92
Equipment Handling Practices .................................................................................... 92
Power and Electrical Warnings ................................................................................... 92
System Access Warnings ........................................................................................... 93
Rack Mount Warnings ................................................................................................. 94
Electrostatic Discharge (ESD) ..................................................................................... 94
Other Hazards ............................................................................................................. 95
Deutsch ............................................................................................................................... 96
Sicherheitshinweise für den Server ............................................................................. 96
Sicherheitshinweise und Vorsichtsmaßnahmen ......................................................... 96
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide xi
Zielbenutzer der Anwendung .......................................................................................97
Standortauswahl ..........................................................................................................97
Handhabung von Geräten ...........................................................................................97
Warnungen zu Netzspannung und Elektrizität ............................................................98
Warnhinweise für den Systemzugang .........................................................................99
Warnhinweise für Racks ............................................................................................100
Elektrostatische Entladungen (ESD) .........................................................................100
Andere Gefahren .......................................................................................................101
Français .............................................................................................................................102
Consignes de sécurité sur le serveur ........................................................................102
Sécurité: avertissements et mises en garde ..............................................................102
Domaines d’utilisation prévus ....................................................................................103
Sélection d’un emplacement .....................................................................................103
Pratiques de manipulation de l’équipement ...............................................................103
Alimentation et avertissements en matière d’électricité .............................................104
Avertissements sur l’accès au système .....................................................................105
Avertissements sur le montage en rack ....................................................................106
Décharges électrostatiques (ESD) ............................................................................106
Autres risques ............................................................................................................107
Español ..............................................................................................................................108
Información de seguridad del servidor ......................................................................108
Advertencias y precauciones sobre seguridad ..........................................................108
Aplicaciones y usos previstos ....................................................................................109
Selección de la ubicación ..........................................................................................109
Manipulación del equipo ............................................................................................109
Advertencias de alimentación y eléctricas .................................................................110
Advertencias el acceso al sistema ............................................................................111
Advertencias sobre el montaje en bastidor ...............................................................112
Descarga electrostática (ESD) ..................................................................................112
B. Installation/Assembly Safety Instructions ....................................................... 119
English ...............................................................................................................................119
Deutsch ..............................................................................................................................121
Français .............................................................................................................................124
Español ..............................................................................................................................126
Italiano ...............................................................................................................................128
C. Getting Help ................................................................ ............................. ........... 131
World Wide Web ................................................................................................................131
Telephone ..........................................................................................................................131
U.S. and Canada .......................................................................................................131
Europe .......................................................................................................................131
In Asia-Pacific region .................................................................................................132
Japan ........................................................................................................................132
Latin America .............................................................................................................132
D. Intel® Server Issue Report Form ...................................................................... 135
E. Warranty ...................................................................... ............................. ........... 139
Limited Warranty for Intel® Chassis Subassembly Products ............................................139
Extent of Limited Warranty ................................................................................................139
Warranty Limitations and Exclusions .................................................................................140
Limitations of Liability ................................................................................................140
xii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
How to Obtain Warranty Service ....................................................................................... 140
Telephone Support .................................................................................................... 141
Returning a Defective Product .................................................................................. 141
F. Regulatory and Compliance Information .........................................................143
Product Regulatory Compliance ........................................................................................ 143
Product Safety Compliance ....................................................................................... 143
Product EMC Compliance - Class A Compliance ..................................................... 144
Certifications / Registrations / Declarations .............................................................. 144
Product Regulatory Compliance Markings ................................................................ 145
Electromagnetic Compatibility Notices .............................................................................. 146
FCC Verification Statement (USA) ............................................................................ 146
Industry Canada (ICES-003) ..................................................................................... 147
Europe (CE Declaration of Conformity) ..................................................................... 147
VCCI (Japan) ............................................................................................................ 147
BSMI (Taiwan) .......................................................................................................... 148
Korean Compliance (RRL) ........................................................................................ 148
Regulated Specified Components ............................................................................. 148
Restriction of Hazardous Substances (RoHS) Compliance .............................................. 149
End of Life / Product Recycling ......................................................................................... 149
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide xiii
List of Figures
Figure 1. Front View of Intel® Entry Server Chassis SC5299-E................................................. 1
Figure 2. Front View Components (with Front Bezel Assembly)................................................ 3
Figure 3. Front View Components (without Front Bezel Assembly)........................................... 4
Figure 4. Internal Components................................................................................................... 5
Figure 5. Back Panel Components............................................................................................. 6
Figure 6. Front Panel Components ............................................................................................ 7
Figure 7. Optional Peripheral Devices........................................................................................ 8
Figure 8. Mechanical Locks...................................................................................................... 10
Figure 9. Removing Left Side Cover ........................................................................................ 12
Figure 10. Installing Left Side Cover ........................................................................................ 12
Figure 11. Removing Front Bezel Assembly............................................................................ 13
Figure 12. Installing the Front Bezel Assembly........................................................................ 14
Figure 13. Removing Processor Air Duct................................................................................. 15
Figure 14. Installing Processor Air Duct................................................................................... 16
Figure 15. Removing Drive Cage EMI Shield from Fixed Drive Cage...................................... 17
Figure 16. Removing Fixed Hard Drive Cage .......................................................................... 18
Figure 17. Removing PCI Card Guide...................................................................................... 18
Figure 18. Re-installing PCI Card Guide into Chassis ............................................................. 19
Figure 19. Inserting Fixed Hard Drive Cage into Chassis ........................................................ 20
Figure 20. Re-attaching Drive Cage EMI Shield ...................................................................... 21
Figure 21. Drive Bay Slot Order ............................................................................................... 22
Figure 22. Removing Drive Cage EMI Shield from Chassis..................................................... 23
Figure 23. Removing PCI Card Guide...................................................................................... 24
Figure 24. Routing Hard Drive Power Cables .......................................................................... 24
Figure 25. Unlatching Drive Latch............................................................................................ 25
Figure 26. Inserting Hard Drive into Drive Cage ...................................................................... 25
Figure 27. Latching Drive Latch ............................................................................................... 26
Figure 28. Drive Bay Slot Order ............................................................................................... 26
Figure 29. Cabling a Fixed Hard Drive..................................................................................... 27
Figure 30. Re-installing Drive Cage EMI Shield....................................................................... 27
Figure 31. Re-installing PCI Card Guide.................................................................................. 28
Figure 32. Preparing Fixed Hard Drive for Removal ................................................................ 29
Figure 33. Removing Fixed Hard Drive from Drive Bay ........................................................... 30
Figure 34. Re-installing Drive Cage EMI Shield....................................................................... 30
Figure 35. Removing 5.25-in Drive EMI Shield ........................................................................ 31
Figure 36. Installing CD-ROM or DVD-ROM Drive .................................................................. 32
Figure 37. Removing CD-ROM or DVD-ROM Drive ................................................................ 33
Figure 38. Installing 5.25-in Drive EMI Shield .......................................................................... 34
Figure 39. Opening PCI Add-in Card Retention Device........................................................... 35
Figure 40. Removing PCI Slot Shield....................................................................................... 35
Figure 41. Installing PCI Add-in Board ..................................................................................... 36
Figure 42. Opening PCI Add-in Card Retention Device........................................................... 37
xiv Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Figure 43. Removing PCI Add-in Board................................................................................... 37
Figure 44. Replacing PCI Slot Shield....................................................................................... 38
Figure 45. Removing Right Side Cover from Chassis ............................................................. 39
Figure 46. Unattaching Front Panel Board from Chassis ........................................................ 39
Figure 47. Removing Front Panel Board from Chassis ........................................................... 40
Figure 48. Removing Standoffs from Front Panel.................................................................... 40
Figure 49. Installing Front Panel Board in Chassis.................................................................. 41
Figure 50. Positioning Front Panel Board in Chassis .............................................................. 41
Figure 51. Re-installing Right Side Cover on Chassis ............................................................. 42
Figure 52. Removing Fan Duct / System Fan Assembly ......................................................... 43
Figure 53. Re-installing Fan Duct / System Fan Assembly...................................................... 43
Figure 54. Unlocking Fixed Power Supply from Chassis......................................................... 44
Figure 55. Removing Fixed Power Supply from Chassis......................................................... 45
Figure 56. Inserting Fixed Power Supply in Chassis ............................................................... 45
Figure 57. Locking Fixed Power Supply into Chassis.............................................................. 46
Figure 58. Removing Power Supply Filler Panel ..................................................................... 47
Figure 59. Inserting Additional Hot Swap Power Supply Module............................................. 47
Figure 60. Removing Hot Swap Power Supply Module from Chassis ..................................... 48
Figure 61. Inserting Hot Swap Power Supply Module in Chassis............................................ 48
Figure 62. Removing Hot Swap Power Supply Module........................................................... 49
Figure 63. Detaching Hot Swap Power Supply Cage from Inside of Chassis.......................... 50
Figure 64. Detaching Hot Swap Power Supply Cage from Rear of Chassis ........................... 50
Figure 65. Removing Rear Support Bracket from Hot Swap Power Supply Cage .................. 51
Figure 66. Attaching Rear Support Bracket to Power Supply Cage ........................................ 51
Figure 67. Securing Hot Swap Power Supply Cage to Rear of Chassis.................................. 52
Figure 68. Securing Hot Swap Power Supply Cage to Inside of Chassis................................ 52
Figure 69. Re-installing Hot Swap Power Supply Module(s) ................................................... 53
Figure 70. Installing Feet on Chassis....................................................................................... 54
Figure 71. Removing Fixed Drive Cage EMI Shield from Chassis .......................................... 56
Figure 72. Removing Fixed Hard Drive Cage from Chassis .................................................... 57
Figure 73. Removing Stud Screws from Hot Swap Drive Cage............................................... 58
Figure 74. Attaching Latch Plate to Hot Swap Drive Cage ...................................................... 58
Figure 75. Attaching Filler Panel to Hot Swap Drive Cage ...................................................... 59
Figure 76. Removing Thumb Screws from Backplane............................................................. 59
Figure 77. Attaching Fan Bracket to Hot Swap Drive Cage (SAS/SATA drive cage illustrated)..
60
Figure 78. Attaching Fan to Fan Bracket ................................................................................. 61
Figure 79. Inserting Hot Swap Drive Cage into Chassis.......................................................... 62
Figure 80. Cabling the SCSI Hot Swap Drive Cage................................................................. 63
Figure 81. Layout of Cable Connectors on the SAS/SATA Backplane (Backplane without ex-
pander shown) ................................................................................................................... 64
Figure 82. Making Six-drive SAS/SATA Hot-Swap Drive Cage Backplane without Expander
Connections (fan bracket not shown in the illustration for clarity)...................................... 65
Figure 83. Making Six-drive Hot Swap Drive Cage Backplane with Expander Connections (fan
bracket not shown in the illustration for clarity) .................................................................. 66
Figure 84. Opening Drive Bay Access Door ............................................................................ 67
Figure 85. Releasing Drive Carrier from Hot Swap Drive Cage............................................... 68
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide xv
Figure 86. Removing Retention Device from Drive Carrier ...................................................... 68
Figure 87. Installing Hard Drive into Drive Carrier.................................................................... 69
Figure 88. Re-installing Drive Carrier in Hot Swap Drive Cage................................................ 69
Figure 89. Closing Drive Bay Access Door .............................................................................. 70
Figure 90. Opening Drive Bay Access Door............................................................................. 70
Figure 91. Removing Drive Carrier from Hot Swap Drive Cage............................................... 71
Figure 92. Removing Hard Drive from Drive Carrier ................................................................ 71
Figure 93. Installing Hard Drive in Drive Carrier....................................................................... 72
Figure 94. Installing Plastic Retention Device in Drive Carrier................................................. 72
Figure 95. Re-installing Drive Carrier in Hot Swap Drive Cage................................................ 73
Figure 96. Closing Drive Bay Access Door .............................................................................. 73
Figure 97. Removing Chassis Feet .......................................................................................... 76
Figure 98. Removing Top Side Cover from Chassis ................................................................ 76
Figure 99. Removing PCI Card Guide...................................................................................... 77
Figure 100. Removing Plastic Filler Panel from Chassis ......................................................... 78
Figure 101. Removing Plastic Plugs ........................................................................................ 79
Figure 102. Removing Rear Screws ........................................................................................ 79
Figure 103. Removing Plastic Plugs from Top Side Cover ...................................................... 80
Figure 104. Installing Rack Handle on Left Side Cover............................................................ 80
Figure 105. Affixing Label to Front Panel................................................................................. 81
Figure 106. Installing Top Side Cover on Chassis ................................................................... 81
Figure 107. Detaching Inner Rack Rail from Rack Rail Assembly ........................................... 82
Figure 108. Attaching Inner Rack Rails to Chassis .................................................................. 83
Figure 109. Attaching Outer Rack Rails to Rack Uprights ....................................................... 84
Figure 110. Installing Chassis into Rack .................................................................................. 85
xvi Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide xvii
List of Tables
Table 1. Breakdown of Intel® Entry Server Chassis SC5299-E Configurations ......................... 1
Table 2. Server Chassis Features.............................................................................................. 2
Table 3. Accessories and Order Codes ................................................................................... 10
Table 4. 550-W Power Supply Output Capability..................................................................... 87
Table 5. 670-W Power Supply Output Capability..................................................................... 88
Table 6. 650-W Power Supply Output Capability..................................................................... 88
Table 7. System Environmental Specifications ........................................................................ 89
Table 8. Product Regulatory Compliance Markings............................................................... 145
xviii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 1
1Server Chassis Features
This chapter describes the main features of the Intel
® Entry Server Chassis SC5299-E.
The location of important chassis components and connections, as well as a description of
LED identification, are also presented.
Figure 1. Front View of Intel® Entry Server Chassis SC5299-E
The Intel® Entry Server Chassis SC5299-E is a 5.2U pedestal1 server chassis and is
available in three configurations: DP (dual-processor), WS (workstation), and BRP (base
redundant power). The chassis is designed to support the Intel® Server Boards
S5000XVN, S5000PSL, S5000XSL and S5000VSA. The type of server board supported
is dependent upon the configuration purchased. See Table 1 for a list of the Intel
® server
boards that are supported by each server chassis configuration.
AF000307
1. The Intel® Entry Server Chassis SC5299-E can be configured as a rack-mountable server chassis when outfitted
with the optional Rack Mount Kit (order code APP3RACKIT).
Table 1. Breakdown of Intel® Entry Server Chassis SC5299-E Configurations
Intel® Entry Server Chassis
SC5299-E Configuration Intel® Server Boards Supported1
DP (Dual-processor) Intel® Server Boards S5000VSA, S5000XSL and S5000PSL
WS (Workstation) Intel® Server Board S5000XVN
BRP (Base Redundant Power) Intel® Server Boards S5000VSA, S5000XSL and S5000PSL
NOTES:
1. For updated server board support, go to http://support.intel.com/support/motherboards/server/
chassis/sc5299-e/.
Server Chassis Features
2Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Table 2 summarizes the features of the Intel
® Entry Server Chassis SC5299-E.
Table 2. Server Chassis Features
Feature Description
Dimensions (pedestal) 17.8 in (45.2 cm) high with feet; 17.6 in (44.7 cm) without feet
9.256 in (23.5 cm) wide
19.2 in ( 48.7 cm) deep
Dimensions (rack) 9.256 in (23.5 cm) high without rack bezel; 10.3 in (26.2 cm) high
with rack bezel
17.6 in (44.7 cm) wide
19.2 in (48.7 cm) deep
Hard drive cage One removable fixed hard drive cage that can accept up to 6 tool-
less cabled 3.5-in x 1-in hard drives.
NOTE: An optional SCSI or SAS/SATA hot swap backplane hard
drive cage (capable of handling up to 6 SCSI, SATA or SAS
hot-swappable hard drives) can be purchased to replace the
fixed hard drive cage.
Peripherals Two tool-less 5.25-in device drive bays for CD-ROM, DVD-ROM
drive, or tape drive
Front panel One for the DP/WS/BRP chassis configurations.
Front Panel LEDs and
displays
NIC1 Activity
NIC2 Activity
Power / Sleep
Hard Drive Activity
System Status
NMI
NOTE:
Power Supply Wattage of power supply is dependent on configuration of server
chassis purchased:
DP - ships with a 550-W PFC tool-less fixed power supply
WS - ships with a 670-W PFC tool-less fixed power supply
BRP - ships with a 650-W PFC redundant power supply module
in a 1+0 configuration. An additional module can be purchased
as an accessory to create a 1+1 configuration.
Fans One 120-mm system fan
One power supply fan1
Processor fans for active thermal solution
Fan with optional hot swap drive kit upgrade
Fixed hard drive fan with WS chassis configuration
USB Two front panel USB ports
NOTES:
1. Power supply fan integrated into power supply module.
Server Chassis Features
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 3
Component Identification
Front View Components
Figure 2. Front View Components (with Front Bezel Assembly)
A. 5.25-in Device Drive Bays
B. Front Panel
C. Drive Bay Access Door
D. Door Lock
E. Front Panel USB Ports
TP02345
B
C
A
D
E
Server Chassis Features
4Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Figure 3. Front View Components (without Front Bezel Assembly)
A. 5.25-in Device Drive Bays
B. 3.5-in Device Drive Bay
C. Hard Drive Cage
D. Drive Bay EMI Shield (shown open)
E. Front Panel USB Ports
TP0088
2
B
A
D
E
C
Server Chassis Features
6Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Back Panel Components
Figure 5. Back Panel Components
A. Power Supply
NOTE: Fixed Power Supply shown. Your Power Supply may
vary depending on chassis configuration purchased
B. A/C Power In
NOTE: Fixed Power Supply shown. Your Power Supply may
vary depending on chassis configuration purchased.
C. Alternate external SCSI knockout
D. System Fan
E. I/O Shield
NOTE: I/O connectors vary, depending on the server board
installed. See your server board documentation for
port identification
F. Alternate Serial B port knockout
G. PCI Add-in Card slots
H. PCI Tool-less Card Retention Mechanisms
I. External SCSI knockout
J. Serial B port knockout
TP00880
B
D
H
A
E
G
C
F
I
J
Server Chassis Features
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 7
Front Panel
Figure 6. Front Panel Components
Callout Feature1,2
NOTES:
1. LED status may vary depending on server board integrated.
Function
A. Power/Sleep LED Continuous green light indicates the system has power applied to it.
Continuous amber light indicates the system is in S1 Sleep state.
No light indicates the power is off / or the system is in S4 Sleep state.
B. Power/Sleep LED Powers the system off or on.
C. NMI Button Used to force system halt and dump memory contents to screen or file.
D. Reset Button Reboots and initializes the system.
E.
F.
NIC 1 Activity LED
NIC 2 Activity LED
Continuous green light indicates a link between system and network.
Blinking green light indicates network activity.
No light indicates the NIC is disconnected.
G. Hard Drive Activity
LED
Random blinking green light indicates hard drive activity (SCSI or SAS/
SATA).
Continous amber light indicates a hard drive fault.
No light indicates no hard disk drive activity.
H. Status LED Solid green indicates system ready (not supported by all server boards).
Blinking green indicates processor or memory disabled.
Solid amber indicates a critical temperature or voltage fault, or a missing
CPU/terminator.
Blinking amber indicates a power fault, fan fault, or a non-critical
temperature or voltage fault.
No light indicates a fatal error during POST.
TP02346
A
C
F
H
B
D
E
G
Server Chassis Features
8Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Peripheral Devices
The server chassis provides locations and hardware for installing hard drives, a floppy
drive, a CD-ROM drive, a DVD-ROM drive or a tape drive. The drives must be purchased
separately. The following figure shows the available options.
NOTE: It is recommended that screws be used to secure large devices if shipping chassis
integrated.
Figure 7. Optional Peripheral Devices
Hard Disk Drives
The server chassis ships with one fixed hard drive cage capable of supporting up to six
cabled 3.5-in x 1-in hard drives. Power requirements for each individual hard drive may
limit the maximum number of drives that can be integrated into the server chassis.
An optional hot-swap SCSI or SAS/SATA backplane hard drive cage (capable of handling
up to six hot-swappable SCSI, SATA or SAS hard drives) may be purchased to replace the
fixed hard drive cage. See Table 3 for order code information.
For instructions on installing hard drives, see “Installing and Removing a Fixed Hard
Drive”.
TP02032
A
Server Chassis Features
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 9
Note: Drives can consume up to 18.4 watts of power each. Drives must be specified to run at a
maximum ambient temperature of 45C.
Note: The Intel® Entry Server Chassis SC5299-E does not support all SCSI or Serial ATA hard
drives. See “Additional Information and Software” for an web link to a list of supported
hardware.
Front Bezel Assembly
The front bezel assembly provides a snap-on design that allows for maximum airflow
through the server chassis.
All configurations of the server chassis ship with a two-piece front bezel assembly.
Rack-Mounted Systems
Your Intel® Entry Server Chassis SC5299-E can be optionally mounted into a rack.
Instructions for installing your chassis into a rack are included with the rail kit.
The order number for the rack mounting kit is APP3RACKIT.
Server Chassis Features
10 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Mechanical Locks
All configurations of the server chassis can support the installation of a padlock loop (see
letter “A” in the following figure) at the rear of the chassis. Additionally, the server
chassis ships with a two-position mechanical lock (see letter “B”) on the front bezel
assembly to prevent access to the hard drives and the interior of the chassis.
Figure 8. Mechanical Locks
Accessories and Order Codes
For a complete list of spares and accessories available for your chassis, see:
http://support.intel.com/go/serverbuilder
AF000308
A
B
Table 3. Accessories and Order Codes
Accessory Order Code
SAS/SATA Hot Swap Drive Bay Upgrade Kit AXX6SASDB
SCSI Hot Swap Drive Bay Upgrade Kit AXX6SCSIDB
Hot Swap Conversion Kit APP3HSDBKIT
Rack Mount Kit APP3RACKIT
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 11
2Hardware Installations and
Upgrades
This document provides instructions for adding and replacing chassis components. For
instructions on replacing components on the server board, such as the processor and
memory FBDIMMs, see the instructions provided with the server board.
Before You Begin
Before working with your server product, review the important safety information listed
in Appendix A, “Safety Information”.
Tools and Supplies Needed
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Needle-nosed pliers
Anti-static wrist strap and conductive foam pad (recommended)
Hex nut driver (6 mm)
System References
All references to left, right, front, top, and bottom assume the reader is facing the front of
the chassis as it would be positioned for pedestal operation.
Removing and Installing the Left Side Cover
Warning: This chassis must be operated with the left side cover installed to ensure proper cooling.
Removing the Left Side Cover
The Intel® Entry Server Chassis SC5299-E must be operated with the left side cover in
place to ensure proper cooling. You will need to remove the left side cover to add or
replace components inside of the platform. Before removing the left side cover, power
down the server and unplug all peripheral devices and the AC power cable.
Note: A nonskid surface or a stop behind the chassis may be needed to prevent the chassis from
sliding on your work surface.
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Turn off all peripheral devices connected to the server. Turn off the server.
Hardware Installations and Upgrades
12 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
3. Disconnect the AC power cord(s).
4. If present, remove the two screws (see letter “A” in the following figure). Push in on
latch with your right hand (see letter “B”), and with your left hand, grasp the rear
cover clasp and slide the left side cover rearward to remove from chassis (see letter
“C”).
Figure 9. Removing Left Side Cover
Installing the Left Side Cover
Warning: This chassis must be operated with the left side cover installed to ensure proper cooling.
1. Slide the left side cover on the chassis and latch securely (see letter “A” in the
following figure).
2. (Optional) Replace screws (see letter “B”).
Figure 10. Installing Left Side Cover
3. Reconnect all peripheral devices and the AC power cord. Power up the server.
TP00559
B
C
A
A
TP00831
B
A
B
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 13
Removing and Installing the Front Bezel Assembly
All configurations of the Intel® Entry Server Chassis SC5299-E ship with a two-piece
front bezel assembly.
Removing the Front Bezel Assembly
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Turn off all peripheral devices connected to the server. Turn off the server.
3. Disconnect the AC power cord.
4. Remove the left side cover. For instructions, see Removing the Left Side Cover”.
5. Disengage the two bezel tabs from the left side of the chassis (see letter “A in the
following figure). Rotate the left side of the front bezel assembly outward slightly (see
letter “B”). Disengage the three clips that attach the right side of the front bezel
assembly to the chassis and remove (see letter “C”).
Figure 11. Removing Front Bezel Assembly
TP02034
C
B
C
C
A
A
Hardware Installations and Upgrades
14 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Installing the Front Bezel Assembly
1. Line up the three clips on the right-side of the front bezel assembly with the
corresponding slots on the right-side of the chassis (see letter “A” in the following
figure). Engage the clips with the slots (see letter “B”). Rotate the left side of the the
front bezel assembly towards the chassis (see letter “C”). Snap the two bezel tabs into
the corresponding recesses at the left edge of the chassis front panel (see letter “D”).
Figure 12. Installing the Front Bezel Assembly
2. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”.
3. Reconnect all peripheral devices and the AC power cable. Power up the server.
TP02035
D
D
A
A
A
C
A
B
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 15
Removing and Installing the Processor Air Duct
Warning: Always operate your server chassis with the processor air duct in place. This air duct is
required for proper airflow within the chassis.
Warning: The processor air duct must only be used with active thermal solutions.
When adding or replacing a processor, first remove the processor air duct, and then refer
to your server board User Guide for instructions on processor installation and removal.
Return to these instructions to reinstall the processor air duct after you have installed your
processor and heat sink.
Removing the Processor Air Duct
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see Removing the Left Side Cover”.
4. Loosen the two mounting screws and remove the processor air duct.
Figure 13. Removing Processor Air Duct
5. Save the screws. You will need them to re-install the processor air duct.
Installing the Processor Air Duct
Warning: DO NOT operate the server chassis without the processor air duct in place. The processor
air duct is required for proper airflow within the chassis.
1. Lower the processor air duct into the chassis and line it up with the two mounting
holes in chassis. Secure the processor air duct to the chassis with two mounting
screws.
TP01136
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 17
5. Loosen thumb screw and remove the drive cage EMI shield (see letter “A” in the
following figure).
Figure 15. Removing Drive Cage EMI Shield from Fixed Drive Cage
6. Disconnect cables from any installed fixed hard drives. If necessary, remove hard
drives from fixed hard drive cage. For instructions on removing fixed hard drives, see
“Removing a Fixed Hard Drive”.
TP01869
A
B
Hardware Installations and Upgrades
18 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
7. Push the blue plastic release mechanism upward to release the fixed hard drive cage
(see letter “A” in the following figure). Once released, pull the fixed hard drive cage
from the chassis (see letter “B”).
Figure 16. Removing Fixed Hard Drive Cage
8. Remove any PCI add-in boards that are present.
9. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the
following figure) and pulling the PCI card guide outward (see letter “B”).
Figure 17. Removing PCI Card Guide
TP02038
B
A
TP01732
A
B
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 19
10. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct”.
11. If installing a server board, refer to your Intel® Server Board Users Guide and/or
Quick Start Users Guide for installation instructions. Use the mounting screws,
bumpers and standoffs (if necessary) that came with your chassis to secure the server
board to the chassis. Make sure the server board is properly seated and then tighten
the screws firmly, starting with the screws at the center of the server board.
If removing a server board, disconnect all cables connected to the server board. Refer
to your Intel® Server Board Users Guide and/or Quick Start Users Guide for
additional removal instructions.
12. Reinstall the processor air duct. For instructions, see Installing the Processor Air
Duct”.
13. Re-install the PCI card guide. Insert tabs on left side of PCI card guide into slots in
chassis (see letter “A” in the following figure). Swing PCI card guide into chassis
until right-side blue tabs snap into place (see letter “B”).
Figure 18. Re-installing PCI Card Guide into Chassis
TP01735
A
B
Hardware Installations and Upgrades
20 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
14. Slide the fixed hard drive cage into the drive bay slot of the chassis. You should hear a
click when the blue plastic retention mechanism locks into place.
Figure 19. Inserting Fixed Hard Drive Cage into Chassis
15. If previously removed, install fixed hard drives and connect power and data cables.
For instructions, see “Installing a Fixed Hard Drive”.
TP02039
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 21
16. Re-attach the drive cage EMI shield to the fixed hard drive cage and tighten the thumb
screw.
Figure 20. Re-attaching Drive Cage EMI Shield
17. Re-install the front bezel assembly. For instructions, see “Removing and Installing the
Front Bezel Assembly”
18. Re-install the left side cover. For instructions, see Installing the Left Side Cover”
19. Plug all peripheral devices and the AC power cable(s) back into the server. Power up
the server.
AF000315
Hardware Installations and Upgrades
22 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
Installing and Removing a Fixed Hard Drive
Up to six fixed hard drives can be installed in the fixed hard drive cage that ships with the
Intel® Entry Server Chassis SC5299-E. Power requirements for each individual hard drive
may limit the maximum number of drives that can be integrated into the server chassis.
Note: The Intel® Entry Server Chassis SC5299-E does not support all hard drives. See
“Additional Information and Software for a web link to a list of supported hard drives.
Installing a Fixed Hard Drive
Caution: Fixed drives are NOT hot swappable. Before removing or replacing the drive, you must
first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
Warning: Drive bay slots 1, 3, and 5 MUST be populated first. Failure to do so could result in
thermal issues within the chassis.
Note: SAS/SATA drives illustrated.
Figure 21. Drive Bay Slot Order
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
AF000316
1
2
4
3
5
6
Hardware Installations and Upgrades
24 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
7. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the
following figure) and pulling the PCI card guide outward (see letter “B”).
Figure 23. Removing PCI Card Guide
8. Route the required power cables (connectors P8-P13) from behind the PCI card guide
through the cable routing area at the bottom of the fixed drive cage.
Figure 24. Routing Hard Drive Power Cables
TP01732
A
B
AF000317
Hardware Installations and Upgrades
26 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
11. Push drive latch in to lock hard drive into drive bay
Figure 27. Latching Drive Latch
12. Install additional drives as necessary.
Warning: Drive bay slots 1, 3, and 5 MUST be populated first. Failure to do so could result in
thermal issues within the chassis.
Figure 28. Drive Bay Slot Order
AF000320
AF000316
1
2
4
3
5
6
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 27
13. Install power (see letter “A” in the following figure) and data (see letter “B”) cables to
each of the installed drives.The cables route through the oval opening at the bottom of
the fixed drive cage.
Figure 29. Cabling a Fixed Hard Drive
14. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw.
Figure 30. Re-installing Drive Cage EMI Shield
AF000429
AB
AF000315
Hardware Installations and Upgrades
28 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
15. Re-install the PCI card guide. Insert tabs on left side of PCI card guide into slots in
chassis (see letter “A” in the following figure). Swing PCI card guide into chassis
until right-side blue tabs snap into place (see letter “B”).
Figure 31. Re-installing PCI Card Guide
16. Re-install any PCI add-in cards that were removed. For instructions, see “Installing
PCI Add-in Boards”.
17. Re-install the front bezel assembly. For instructions, see Installing the Front Bezel
Assembly”
18. Re-install the left side cover. For instructions, see Installing the Left Side Cover”
19. Plug all peripheral devices and the AC power cable back into the server. Power up the
server.
Removing a Fixed Hard Drive
Caution: Fixed drives are NOT hot swappable. Before removing or replacing the drive, you must
first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”.
4. Remove the front bezel assembly. For instructions, see “Removing and Installing the
Front Bezel Assembly”.
TP01735
AB
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 29
5. Loosen thumb screw (see letter “A” in the following figure). Apply slight pressure to
right side of drive bay access door and swing door outward (see letter “B”).
6. Disconnect the data and power cables from the hard drive to be removed (see letter
“A” in the following figure). Pull the drive latch forward (see letter “B”) to unlatch
the drive locking mechanism for the hard drive you want to remove.
Figure 32. Preparing Fixed Hard Drive for Removal
TP01869
A
B
AF000430
A
B
Hardware Installations and Upgrades
30 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
7. Slide the hard drive out of the fixed hard drive cage and place on an anti-static
surface. If replacing the hard drive, see “Installing a Fixed Hard Drive” for
instructions.
Figure 33. Removing Fixed Hard Drive from Drive Bay
8. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw.
Figure 34. Re-installing Drive Cage EMI Shield
9. Re-install the front bezel assembly. For instructions, see “Installing the Front Bezel
Assembly”
10. Re-install the left side cover. For instructions, see “Installing the Left Side Cover”
AF000431
AF000315
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 31
11. Plug all peripheral devices and the AC power cable(s) into the server. Power up the
server.
Installing or Removing a DVD-ROM or CD-ROM Drive
Caution: CD-ROM and DVD-ROM drives are NOT hot swappable. Before removing or replacing
the drive, you must first take the server out of service, turn off all peripheral devices
connected to the system, turn off the system by pressing the power button, and unplug the
AC power cord from the system or wall outlet.
Installing a DVD-ROM or CD-ROM Drive
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”.
4. Remove the front bezel assembly. For instructions, see “Removing the Front Bezel
Assembly”.
5. Remove the EMI shield from the 5.25-in device drive bay (see letter “A” in the
following figure). Move latch to the “unlock” position (see letter “B”).
Figure 35. Removing 5.25-in Drive EMI Shield
TP01063
A
B
Hardware Installations and Upgrades
32 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
6. Insert CD-ROM or DVD-ROM drive into the 5.25-in device drive bay (see letter “C”
in the following figure). Line up holes in CD-ROM drive with holes in chassis (see
letter “D”). Move latch to the “lock” position (see letter “E”). Connect power (P3 or
P4 connector from the power supply) and data cables to the rear of the CD-ROM or
DVD-ROM drive (see letter “F”).
Figure 36. Installing CD-ROM or DVD-ROM Drive
7. If necessary, remove the filler panel from the front bezel assembly.
C
E
F
D
TP01064
TP01723
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 33
8. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel
Assembly”.
9. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”.
10. Reconnect all peripheral devices and the AC power cable(s). Power up the server.
Removing a CD-ROM or DVD-ROM Drive
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Left Side Cover”.
4. Remove the Front Bezel Assembly. For instructions, see “Removing the Front Bezel
Assembly”.
5. Disconnect the power and data cables from the rear of the CD-ROM or DVD-ROM
drive (see letter “A” in the following figure). Move latch to the “unlock” position (see
letter “B”). Slide CD-ROM or DVD-ROM drive out of the Device Drive Bay (see
letter “C”).
Figure 37. Removing CD-ROM or DVD-ROM Drive
TP02047
C
B
A
Hardware Installations and Upgrades
36 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
7. Hold the PCI add-in board by its top edge or upper corners. Firmly press the add-in
board into an expanision slot on the server board (see letter “A” in the following
figure). Close the back panel PCI Add-in Card Retention Device (see letter “B”).
Figure 41. Installing PCI Add-in Board
8. Repeat the previous steps until all PCI add-in boards are installed.
9. Attach cables, if necessary.
10. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”.
11. Reconnect all peripheral devices and the AC power cable. Power up the server.
Removing PCI Add-in Boards
Caution: PCI add-in boards can be extremely sensitive to electric static discharge (ESD) and
always require careful handling. After removing the add-in board from its protective
wrapper or from the server board, place it component side up on a grounded, static-free
surface or conductive foam pad. Do not slide the add-in board over any surface.
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”.
TP01745
B
A
B
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 37
4. Open the back panel PCI Add-in Card Retention Device by pressing open from the
inside of the chassis.
Figure 42. Opening PCI Add-in Card Retention Device
5. Disconnect any cables that may be attached to the PCI add-in board that needs to be
removed.
6. Firmly grab the PCI add-in board by its top edge or upper corners and remove from
the expansion slot on the server board (see letter “A” in the following figure). Place
the removed add-in board in an anti-static protective wrapper. Close the back panel
PCI Add-in Card Retention Device (see letter “B”).
Figure 43. Removing PCI Add-in Board
TP02049
TP01724
B
A
B
Hardware Installations and Upgrades
38 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
7. If available, replace the PCI slot shield by pressing the slot shield into the opening on
the chassis.
Figure 44. Replacing PCI Slot Shield
8. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”.
9. Reconnect all peripheral devices and the AC power cable(s). Power up the server.
Replacing the Front Panel Board
Your server must be operated with a front panel board installed.
Caution: The front panel board is NOT hot swappable. Before removing or replacing the front
panel board, you must first take the server out of service, turn off all peripheral devices
connected to the system, turn off the system by pressing the power button, and unplug the
AC power cord from the system or wall outlet.
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”
4. Remove the front bezel assembly if it is installed. For instructions, see “Removing the
Front Bezel Assembly”.
TP01726
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 39
5. Remove the two screws (see letter “A” in the following figure”) securing the right
side cover to the chassis. Lift the right side cover off the chassis.
Figure 45. Removing Right Side Cover from Chassis
6. Remove the three screws securing the front panel board to the chassis.
Figure 46. Unattaching Front Panel Board from Chassis
TP01736
A
A
TP01737
Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 41
9. Attach the front panel cable (see letter “A” in the following figure) and the chassis
intrusion cable (see letter “B”) to the new front panel board. Slide the new front panel
board through the opening in the left side of chassis (see letter “C”).
Figure 49. Installing Front Panel Board in Chassis
10. Use one hand to align the front panel board in position inside the chassis. With your
other hand, tighten the three screws to secure the front panel board to the front of the
chassis.
Figure 50. Positioning Front Panel Board in Chassis
AF000433
A
C
B
TP01740
Hardware Installations and Upgrades
42 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
11. Reinstall the right side cover. Reinstall the two screws.
Warning: This chassis must be operated with the right side cover installed to ensure proper cooling.
Figure 51. Re-installing Right Side Cover on Chassis
12. Reinstall the front bezel assembly. For instructions, see “Installing the Front Bezel
Assembly”.
13. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”
14. Reconnect all peripheral devices and the AC power cable. Power up the server.
Replacing a System Fan
Caution: The system fan for the Intel® Entry Server Chassis SC5299-E is NOT hot swappable.
Before removing or replacing a fan, you must first take the server out of service, turn off
all peripheral devices connected to the system, turn off the system by pressing the power
button, and unplug the AC power cord from the system or wall outlet.
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”.
TP01741
Hardware Installations and Upgrades
46 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
8. Rotate the blue locking mechanism to the locked position (see letter “A” in the
following figure).
Figure 57. Locking Fixed Power Supply into Chassis
9. Route and connect the P1, P2, and P14 cables to the server board. Refer to the Intel
®
Server Board Quick Start Users Guide or User Guide that came with your Intel®
server board for appropriate power connections.
10. Route the P5 cable to the floppy drive.
11. Route the P3 and P4 cables to the 5.25-in. removable media device bays and connect
to installed devices.
12. Route the P8, P9, P10, and P12 cables to the hard drive cage and connect power
cables to installed devices.
13. Install the left side cover. For instructions, see “Installing the Left Side Cover”.
14. Reconnect all peripheral devices and the AC power cable to the server. Power up the
server.
TP01755
A

Termékspecifikációk

Márka: Intel
Kategória: nincs kategorizálva
Modell: SC5299WS

Szüksége van segítségre?

Ha segítségre van szüksége Intel SC5299WS, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Intel

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva