Használati útmutató HeatStar HS9120
Olvassa el alább 📖 a magyar nyelvű használati útmutatót HeatStar HS9120 (48 oldal) a Fűtő kategóriában. Ezt az útmutatót 5 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/48
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all
instructions. Place instructions in a safe place for future
reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate the heater.
HEATSTAR High-Intensity Infrared Heaters
MODELS
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
WARNING:
— Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisorany
other appliance.
— WHATTODOIFYOUSMELLGAS
• OpenWindows
• DO NOT try to light any appliance.
• DO NOT use electrical switches.
• DO NOTuseanytelephoneinyourhouse.Immediatelycallyourlocalgassupplierfroma
telephoneremotefromtheareaoftheleak.Followthegassupplier'sinstructions.
• DO NOT touch any electrical switch; do not use any phone in your building.
• Installationandservicemustbeperfomedbyaqualifiedinstaller,serviceagencyorthegas
supplier.
• Ifyoucannotreachyourgassupplier,calltheFireDepartment.
Thisisanunventedgas-firedheater.Itusesair(oxygen)fromtheareainwhichitisused.Adequate
combustionandventilationairmustbeprovided.Refertopage5.
ENERCOGROUPINC.,4560W.160THST.,CLEVELAND,OHIO44135•866-447-2194
4000 & 8000 Models 9000 Models
HS4030 HS8070 HS9100
HS4040 HS9080 HS9120
HS8050 HS9090 HS9140
HS8060 HS9100S
WARNING: Improperinstallation,adjustment,alteration,serviceormaintenancecancauseproperty
damage, injury or death. Read the installation, operation, and maintenance instructions thoroughly before
installingorservicingthisheater.Forassistanceoradditionalinformationconsultaqualifiedinstaller,service
agency, or gas supplier.
E2
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual
CONTENTS
GeneralInformation 3 ..........................................................
Clearances ........................................................................ 3
GasSupply 3 ........................................................................
GasPressure 4 .....................................................................
Electrical ........................................................................... 5
Thermostat&Location 5 ......................................................
Ventilation 5 ........................................................................
Operations ........................................................................5
CleaningInformation 5 ........................................................
Thermostat 6 .......................................................................
Troubleshooting 7 ................................................................
Connection diagram for flame rod current
for flame rectification systems ...................................... 8
Replacement parts ............................................................ 9
Control system replacement parts ....................................12
LANGUAGES
ENGLISH
Pages E1 — E16
SPANISH
Pages S1 — S16
FRENCH
Pages F1 — F16
`
WARNING: READTHISOWNER'SMANUAL
CAREFULLYANDCOMPLETELYBEFORETRYINGTO
ASSEMBLE,OPERATE,ORSERVICETHISHEATER.
IMPROPERUSEOFTHISHEATERCANCAUSESERIOUS
INJURYORDEATHFROMBURNS,FIRE,EXPLOSION,
ELECTRICALSHOCK,ANDCARBONMONOXIDE
POISIONING.
WARNING: WHENUSEDWITHOUTFRESH
AIR,HEATERMAYGIVEOFFCARBONMONOXIDE,AN
ODORLESSPOISONOUSGAS.OPENWINDOWANINCH
ORTWOFORFRESHAIRWHENUSINGHEATER.
WARNING: Thisheaterisequippedwitha
PILOTLIGHTSAFETYSYSTEM.DONOTTAMPERWITH
PILOTLIGHTSAFETYSYSTEM.
WARNING: Ifheatershutsoff,donotrelight
untilyouprovidefreshair.Ifheaterkeepsshuttingoff,
haveitserviced.Opendoorfor5minutes.
•Keepburnerandignitioncontrolclean.
•MaintainclearancesasshowninTable1oronheaterratetag.
•DONOTUSEMATCHOROTHERFLAMEFORLEAK
TESTING.
•DONOTEXCEED1/2PSIINLETPRESSURETOHEATER.
WARNING: Fuelsusedinliquefiedpropanegas
appliances, and the products of combustion of such fuel,
canexposeyoutochemicalsincludingbenzene,which
is know to the state of California to cause cancer and
causebirthdefectsorotherreproductiveharm,formore
informationgotowww.P65Warnings.ca.gov
CAUTION:
•Neverconnectgasvalveorthermostattolinevoltage
or a transformer.
•Iftheinfra-redcolorofthegridbecomesdullwhenthe
building furnace is operating, consult gas supplier on
correctgassupplypipingsizes.
•Thisheaterisforindoorinstallationonly!
Carbon Monoxide Poisoning:
Earlysignsofcarbonmonoxidepoisoningresemblethe
flu,withheadaches,dizziness,ornausea.Ifyouhave
thesesigns,theheatermaynotbeworkingproperly.Get
freshairatonce!Haveheaterserviced.Somepeopleare
moreaffectedbycarbonmonoxidethanothers.These
include pregnant women, persons with heart or lung
disease or anemia, those under the influence of alcohol,
and those at high altitudes.
DANGER:
CarbonMonoxidepoisoningmayleadtodeath.
NOTEGasketbindermaterialusedinthisheateras-
semblywilltemporarilyemitanodorand/orvapor.This
conditionwillclearupinapproximately20minutesand
thereafterwillnotreoccur.Refertopage5for
ventilation.
WARNING: THISPRODUCTCANEXPOSE
YOUTOCHEMICALSINCLUDINGLEADANDLEAD
COMPOUNDS,WHICHAREKNOWNTOTHESTATE
OFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTSOROTHERREPRODUCTIVEHARM.FORMORE
INFORMATIONVISITWWW.P65WARNINGS.CA.GOV
E3 Operating Instructions and Owner’s ManualEnerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
1. GENERAL INFORMATION
a. Yourheatercomesfullyassembledandistestedat
the factory for proper gas and input as stated on
the name plate.
b. Beforeproceedingwiththeinstallation,besuretoin-
spectfordamages.Thefreightcompanythatdelivered
the heater must be notified of any damages prior to
installation.HEATSTARwillsendreplacementpartsfor
damagedpartsonlyafterreceivingasignedinspection
reporttoprovetheliabilityofthefreightcompany.
c. Do not attempt to operate heater with any other gas
than that indicated on the heater name plate.
d. Installationoftheheatermustconformwithlocal
building codes or, in absence of local codes, with
theNationalFuelGasCode,ANSIZ223.1/NFPA54.In
Canada,refertoCAN1-B146.1.
e. Plugged1/8”N.P.T.TestGageConnectionislocated
ontheHeaterGasControloraN.P.T.Connectionis
locatedontheoutsideoftheCastVenturi.
f. Forindoorinstallationonly.Notforuseinresidential
dwellings.NOTE:Aresidentialdwellingisadomicile
intended for use by one or more persons and that
includes one or more areas, such as those used for
cooking,eating,living,sleeping,orasanitaryfacility.A
residential dwelling does not include an attached and
detached garage, workshop, or outdoors.
2. CLEARANCES Minimum clearances to combustibles.
(Refer to Table 1)
Provideadequateclearancetocombustibles,Figure
1,betweencontrolendofheaterforservicing
andminimumontopandsidesforventilationand
combustion air supply.
Aminimumclearanceof8’abovefloorforpublic
garagesinaccordancewithANSI/NFPANo.88most
recenteditionorTable1;whicheverislarger.InCanada
refertoCAN1-B149.1InstallationcodesforGas
burning appliances.
Aminimumclearanceof10’fromthebottomof
heater to top of wing, or engine enclosure, where
aircraftarehoused,and8’abovefloorinotherareas
ofthehangerinaccordancewithANSI/NFPANo.409
mostrecentedition,orTable1;thelargerdimension
ofANSI/NFPANo.409orFigure1istobeused.In
CanadarefertoCCAB149-1-M91.
WARNING: MAINTAINCLEARANCESASSHOWN
INFIGURE1ORONHEATERNAMEPLATE,INGARAGE
INSTALLATIONSWHEREPARKEDVEHICLESARE
DIRECTLYBELOWTHEHEATER.
3. SUSPENSION
Heaterhasfourmountingholes,twooneachend,for
attaching rod or angle iron brackets and shall be safely
andadequatelyfixedinpositionindependentofgas
andelectricsupplylines.RefertoFigures4,5,and7on
pages13and14forrecommendedsuspensions.
4. GAS SUPPLY
Provideadequategassupplyforratedinputofeach
heaterusingAmericanStandardInstallationofgas
pipingandgasappliancesinbuildingANSI/223.1a/
NFPA54Pamphlet,TableC-3showscapacityofpipe
of different diameters and lengths in cubic feet per
hourforNaturalGaswithpressuredropof0.3inches
specifygravityof0.60.ForliquefiedPetroleumGas
(LP)capacityrefertoTableC-3andC-15ofthesame
pamphlet.Forrecommendedheatergasconnection
refertoFigureNo.5,Page15.InCanadarefertoCAN
1-B149.1,andCSAB63.
Ifgaslinesaretobepressuretestedwithcompressed
air,disconnecteachheatertopreventcontroldamage
andcapoutlets.Afterreconnectingallheaters,purge
gas lines of air and check all connections for leaks us-
ing soap solution.
WARNING: DONOTUSEMATCHOROTHER
FLAMEFORLEAKTESTING.
5. PIPING REQUIREMENTS
Allpipinginstalledmustcomplywithlocalcodesandordinances
orwiththeNationalFuelGasCode,ANSIZ223.1(NFPA54),
whichevertakesprecedence.Wheninstallingpiping,thefollowing
requirementsmustbetakenintoconsideration:
• Usenewproperlyreamedblackpipefreefromchips.
• Applyagoodqualitypipecompoundtoallmalethreads
priortoassembly.IfL.P.gasisthefuel,ensurethatpipe
compoundisresistanttoL.P.gas.DONOTUSETEFLON
™ tape.
• Priortoinstallation,applypipecompoundtoallmale
threadsasshowninFigure1
• Malethreadsonpipetobeinstalledintogasvalveshall
meettherequirementsofFigure2.Threadslongerthan
thoseshowninthefiguremaycausegasvalvedistortion
and malfunction.
• Asedimenttrapmeetingthetypicalrequirementsof
Figure3shallbeinstalledinthelinetothegasvalve.
• Adedicatedshutoffvalvefortheheatermustbein-
stalled in the gas supply line.
Figure 1. Pipe Compound Application
USE MODERATE AMOUNT OF PIPE DOPE
LEAVE FIRST 2 THREADS BARE
¾3/4”MAXIMUMTHREADLENGTH
½”BLACKPIPE
TOGASVALVEBODY
Figure 2.
Gas valve
connection
requirements
Termékspecifikációk
Márka: | HeatStar |
Kategória: | Fűtő |
Modell: | HS9120 |
Szüksége van segítségre?
Ha segítségre van szüksége HeatStar HS9120, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Fűtő HeatStar
19 Augusztus 2024
19 Augusztus 2024
17 Augusztus 2024
17 Augusztus 2024
16 Augusztus 2024
16 Augusztus 2024
15 Augusztus 2024
15 Augusztus 2024
15 Augusztus 2024
14 Augusztus 2024
Útmutatók Fűtő
- Fűtő Mestic
- Fűtő Dometic
- Fűtő Electrolux
- Fűtő Nedis
- Fűtő Milwaukee
- Fűtő Parkside
- Fűtő Candy
- Fűtő Philips
- Fűtő Gorenje
- Fűtő Adler
- Fűtő Princess
- Fűtő SilverCrest
- Fűtő Bosch
- Fűtő NewAir
- Fűtő MPM
- Fűtő AEG
- Fűtő Emerio
- Fűtő Einhell
- Fűtő Bartscher
- Fűtő Maxwell
- Fűtő Hyundai
- Fűtő Scarlett
- Fűtő Tefal
- Fűtő HQ
- Fűtő Emos
- Fűtő Corbero
- Fűtő Camry
- Fűtő Xiaomi
- Fűtő Danby
- Fűtő DeLonghi
- Fűtő Clean Air Optima
- Fűtő Heinner
- Fűtő Infiniton
- Fűtő Sunbeam
- Fűtő Beurer
- Fűtő Trumatic
- Fűtő Wilfa
- Fűtő Klarstein
- Fűtő VOX
- Fűtő Scheppach
- Fűtő Vivax
- Fűtő Conceptronic
- Fűtő Thomson
- Fűtő Fagor
- Fűtő Unold
- Fűtő SHX
- Fűtő Brentwood
- Fűtő Ardes
- Fűtő Cuisinart
- Fűtő Eden
- Fűtő Eurolite
- Fűtő Jocel
- Fűtő Duronic
- Fűtő Bimar
- Fűtő Clatronic
- Fűtő Bomann
- Fűtő Bauknecht
- Fűtő Dyson
- Fűtő Ambiano
- Fűtő Cecotec
- Fűtő Sencor
- Fűtő Pelgrim
- Fűtő Qlima
- Fűtő Baxi
- Fűtő Innoliving
- Fűtő Rowenta
- Fűtő Güde
- Fűtő Eta
- Fűtő Izzy
- Fűtő Nevir
- Fűtő JANDY
- Fűtő GoldAir
- Fűtő Domo
- Fűtő Russell Hobbs
- Fűtő Caso
- Fűtő Solac
- Fűtő Carson
- Fűtő Create
- Fűtő Crane
- Fűtő Mora
- Fűtő Black & Decker
- Fűtő Enders
- Fűtő Global
- Fűtő Livington
- Fűtő Orbegozo
- Fűtő Lenoxx
- Fűtő Livoo
- Fűtő Eberle
- Fűtő ARGO
- Fűtő Guzzanti
- Fűtő Concept
- Fűtő DCS
- Fűtő DEDRA
- Fűtő SVAN
- Fűtő SPC
- Fűtő Nobo
- Fűtő TriStar
- Fűtő Suntec
- Fűtő BaseTech
- Fűtő Zodiac
- Fűtő RYOBI
- Fűtő Fantini Cosmi
- Fűtő Chauvet
- Fűtő Midea
- Fűtő Steba
- Fűtő Trisa
- Fűtő Heller
- Fűtő Kogan
- Fűtő Honeywell
- Fűtő Broan
- Fűtő Mesko
- Fűtő Velleman
- Fűtő Dimplex
- Fűtő Master
- Fűtő Kenmore
- Fűtő Thermex
- Fűtő Hayward
- Fűtő DCG
- Fűtő Tesy
- Fűtő Melissa
- Fűtő Trotec
- Fűtő Blaupunkt
- Fűtő AstralPool
- Fűtő Korona
- Fűtő Stadler Form
- Fűtő Taurus
- Fűtő Signature
- Fűtő Olympia
- Fűtő Logik
- Fűtő NEO Tools
- Fűtő AFK
- Fűtő Everdure
- Fűtő DeWalt
- Fűtő Kalorik
- Fűtő Waldbeck
- Fűtő Alpina
- Fűtő Philco
- Fűtő Brandson
- Fűtő ECG
- Fűtő Stanley
- Fűtő Rotel
- Fűtő Vemer
- Fűtő Vornado
- Fűtő Ufesa
- Fűtő Vonroc
- Fűtő Rinnai
- Fűtő Cotech
- Fűtő Argoclima
- Fűtő Ausclimate
- Fűtő WAGAN
- Fűtő Beper
- Fűtő Bestron
- Fűtő Orion
- Fűtő Soler & Palau
- Fűtő SereneLife
- Fűtő Ravanson
- Fűtő Teesa
- Fűtő Becken
- Fűtő OneConcept
- Fűtő Haeger
- Fűtő Olimpia Splendid
- Fűtő Orava
- Fűtő Eurom
- Fűtő Mill
- Fűtő Maestro
- Fűtő Eureka
- Fűtő Sogo
- Fűtő Sonnenkönig
- Fűtő Fluval
- Fűtő Lifesmart
- Fűtő Flama
- Fűtő Tectro
- Fűtő Fenix
- Fűtő Zibro
- Fűtő Quigg
- Fűtő AKO
- Fűtő Invicta
- Fűtő Haverland
- Fűtő Calor
- Fűtő Sinbo
- Fűtő Jata
- Fűtő Swan
- Fűtő Anslut
- Fűtő Sun Joe
- Fűtő EWT
- Fűtő Mellerware
- Fűtő Nestor Martin
- Fűtő Termozeta
- Fűtő Eldom
- Fűtő Cresta
- Fűtő Defy
- Fűtő Bionaire
- Fűtő Maginon
- Fűtő Otsein-Hoover
- Fűtő Profile
- Fűtő Ferroli
- Fűtő Real Flame
- Fűtő Evolar
- Fűtő Perel
- Fűtő Zibro Kamin
- Fűtő Proline
- Fűtő Royal Sovereign
- Fűtő King
- Fűtő Malmbergs
- Fűtő Piazzetta
- Fűtő Heylo
- Fűtő Kent
- Fűtő Arnold Rak
- Fűtő CasaFan
- Fűtő Wamsler
- Fűtő Duux
- Fűtő Imetec
- Fűtő Alpatec
- Fűtő Blaze
- Fűtő Sygonix
- Fűtő Primo
- Fűtő Creda
- Fűtő SuperFish
- Fűtő Plieger
- Fűtő Reer
- Fűtő Zehnder
- Fűtő Napoleon
- Fűtő Essentiel B
- Fűtő Prime3
- Fűtő Blumfeldt
- Fűtő CaterChef
- Fűtő Kambrook
- Fűtő Zephir
- Fűtő Harvia
- Fűtő Brixton
- Fűtő Superior
- Fűtő Kunft
- Fűtő La Nordica
- Fűtő Jotul
- Fűtő Vasco
- Fűtő Noveen
- Fűtő Nectre
- Fűtő Cadel
- Fűtő Grunkel
- Fűtő PAX
- Fűtő Jaga
- Fűtő Lervia
- Fűtő Masport
- Fűtő REMKO
- Fűtő Extraflame
- Fűtő Lynx
- Fűtő Just Fire
- Fűtő Optimum
- Fűtő Hartig And Helling
- Fűtő Gutfels
- Fűtő Westfalia
- Fűtő TAIDEN
- Fűtő Veito
- Fűtő Ecoteck
- Fűtő Etherma
- Fűtő Nordic Fire
- Fűtő Haas+Sohn
- Fűtő Eurotronic
- Fűtő Wanders
- Fűtő Grandhall
- Fűtő Emga
- Fűtő Heatstrip
- Fűtő Escea
- Fűtő Braemar
- Fűtő Bromic Heating
- Fűtő Martec
- Fűtő Jindara
- Fűtő Neo
- Fűtő SPT
- Fűtő Hatco
- Fűtő SunRed
- Fűtő Aerian
- Fűtő IXL
- Fűtő XPower
- Fűtő True North
- Fűtő WestBend
- Fűtő Hortus
- Fűtő Prem-i-air
- Fűtő Quadra-Fire
- Fűtő Mr. Heater
- Fűtő Stenda
- Fűtő VIESTA
- Fűtő Apricus
- Fűtő Heatsome
- Fűtő Brivis
- Fűtő Hubbell
- Fűtő Pacific Energy
- Fűtő Dri Eaz
- Fűtő Regency
- Fűtő Burley
- Fűtő Monzana
- Fűtő Invroheat
- Fűtő Kaden
- Fűtő Jarden
- Fűtő Noirot
- Fűtő Ouellet
- Fűtő AccuLux
- Fűtő Gossmann
- Fűtő Wulfe
- Fűtő Duro Pro
- Fűtő Herschel
- Fűtő Casaya
- Fűtő HyCell
- Fűtő TURBRO
- Fűtő Radialight
- Fűtő Sunheat
- Fűtő Heidenfeld
- Fűtő Hcalory
- Fűtő Rowi
- Fűtő Neopower
- Fűtő Arlec
- Fűtő Guardian
- Fűtő Big Ass Fans
- Fűtő Pureheat
- Fűtő EvoHeat
- Fűtő Bromic
- Fűtő MSW
- Fűtő Solamagic
- Fűtő Contura
- Fűtő Mirpol
- Fűtő Alkari
- Fűtő Longvie
- Fűtő Blue Rhino
- Fűtő Rheem
- Fűtő Gasmate
- Fűtő Ionmax
- Fűtő Airo
- Fűtő Mission Air
- Fűtő Omega Altise
- Fűtő Scandia
- Fűtő Vasner
- Fűtő Fire Sense
- Fűtő InfraNomic
- Fűtő Heat Storm
- Fűtő Excelair
- Fűtő Heatscope
- Fűtő Heat1
- Fűtő Thermotec
- Fűtő Perfect Aire
- Fűtő AustWood
- Fűtő Uniprodo
- Fűtő Infratech
- Fűtő Yamazen
- Fűtő TANSUN
- Fűtő Universal Blue
Legújabb útmutatók Fűtő
22 December 2024
22 December 2024
22 December 2024
22 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
21 December 2024
20 December 2024