USERMANUAL
ModelMA440400A DMMACClampMeter
ModelMA443TrueRMS400ACClampMeter DMM
ModelMA445TrueRMS400AAC/DCClampMeterDMM
MA44x 8/16‐en‐GB_V1.0
2
Introduction
Thank you forselectingthe Extech EX44x 400A Series ClampMeter.
The MA440 is a 400AACClampmeterwith a total of 9 functions.
The that MA443 is a 400A True RMSACClampmeter offers10functionsincludingTRMSAC
measurementsandType K Thermocouple
The MA445 isa AC/DC True TRMS400A RMSClampmeterwith11functionsincludingDCCurrent,
ACmeasurements, and Type K Thermocouple.
TheMA44x 4000seriesarehand‐held, countclampmeters. seriesThismeter measures AC/DC
voltage,ACcurrent,DCcurrent (MA445), continuity, resistance,diode, capacitance,temperature
(MA443 MA445),and frequency,anddutycycle.Inaddition,thesemetersofferDisplayhold,MIN‐
MAX(MA443 MA445), Relativeand mode,NCV(non‐contactvoltage detection), andautomatic
powerOFF.
Inadditionto (Quickthe themeter, packagingincludesInstructionaldocumentation Start),Test
Leads, ‐K typetemperatureprobe(MA443 MA445),and batteries,and a pouch.
This tested calibrated reliabledeviceisshippedfully and and,withproperuse,willprovideyearsof
service. forPleasevisitour website (www.extech.com) tocheck thelatestversionofthisUser
Guide,ProductUpdates, CustomerProductRegistration,and Support.
Safety
Toensurethe thesafeoperationandserviceof meter,followtheseinstructionsclosely.Failuretoobserve
warningscanresultinseverepersonalinjuryordeath.
TheseinstrumentsaredesignedandproducedinstrictaccordancewithIEC/EN61010‐1,IEC/EN61010‐ ‐ 2 032,
and andIEC/EN61010‐ ‐2 033,safetystandards, comply with the safety standard for double insulation,
overvoltageCATIII600Vandpollutionlevel2.Pleaseobserve all operational and safety instructions
otherwisetheprotection provided byinstrumentmaybecompromised.
These standardinstrumentsconformtoUL 61010‐1, 61010 032, 61010 033; ‐ ‐2 ‐ ‐2theseinstrumentsare
certifiedtoCSA no.standardC22.2 61010‐1, 61010 032, 61010IECstandard ‐ ‐2andIECstandard ‐ ‐2 033.
CAT test connected sectionIII:Applicableto andmeasuringcircuits tothedistribution of a building’slow
voltage safetymainsinstallation;beforeuse pleaseoftheseinstruments observeandobeyall instructions.
MA44x 8/16‐en‐GB_V1.0
3
WARNINGS
WARNINGS BODILYidentifyhazardous causeconditionsandactionsthatcould HARMorDEATH.
1. Beforeuse, operation.checktheclampmeterandprobefordamageorabnormal Donotusethemeter
if isprobeinsulationdamage,meter meterdisplayproblems,abnormal functioning,etc. observed.
2. Neverusethe the themeterwith batterycompartmentopen or with meterhousingdisassembledinany
way; otherwise a risk of shock will exist.
3. Whentakingmeasurements,ensurethat and theyourhand fingersarein safeareabehindthefinger
guard.Donottouchbarewireorconnectors, unused inputterminals,orthecircuitundertesttoprevent
electricalshock.
4. Beforetakingmeasurements,thefunction position.switchmustbesettothecorrect Toprevent
damagetothemeter, the function switch must not be turned while measurements are taking place.
5. Do DCnotapplyvoltage600VACor orgreater between the clamp meter terminals and ground. Failure
tofollowtheseinstructionscan cause electric shock and damage to the meter.
6. 42V Whenmeasuringsignals >DCor > 30VAC pleaserms usecaution electricalastheselevelscancause
shock.
7. Donot measure voltageorcurrenthigherthan the the allowableinput; functionswitchmustbesetto
themaximumrangepositionfirstwhen measuredthe therangeof signalisunknown.Beforemeasuring
resistance, diode, and andcontinuitypleaseremovepowertothecircuit under test dischargeall
capacitors.
8. Whenthelowbatterysymbolisdisplayed,replaced the batteries promptly to ensure measurement
precision.Removebatteriesfromthe meter if the meter is to be stored longer than 60 days.
9. Donotservice must serviceor ofmodifytheinternalcircuits themeter.Qualifiedpersonnel themeter
only.
10. Donot notusethemeterinflammableorexplosive environments (gasorvapors).Do usethemeterin
environmentsthat theexceedtheoperationaltemperatureandhumidityspecifications.Donotuse
meterinareas where a strong electromagnetic field is present.
11. Tocleanthemeter,useonly a softdampcloth(neutraldetergentsonly)towipethemeterhousing.Do
notuseabrasivesorsolvents.Donot clean the meter if it is powered on or connected to a circuit under
test;alwayspower OFFthemeter and thedisconnect test leads before cleaning.
12. Useonlythetestprobesprovided.Replacetest testprobeswith better.onesof orthesamerating The
probesaretobeusedfor ‐mains measurements CAT III or CAT IV in accordance with IEC 61010 031 and
shallhave voltage aratingof ofat theleast voltage thecircuittobemeasured.
13. Individualprotectiveequipmentshouldbeusedif inHAZARDOUSLIVEparts theinstallationwhere
measurementsareto be carried out could be accessible.
14. Ifthe theequipmentis inused a mannernotspecified by by the themanufacturer, protection provided
equipmentmaybeimpaired.
15. Toreduce of ortherisk fire electric doshock, not expose this product to rain or moisture.
16. Verifythe themeteroperationbymeasuring a knownvoltage. doubt,Ifin have meterserviced.
17. Toavoidfalse that as as thereadings canlead injury, batterytoelectricshockand replace soon low
batteryindicator appears.
18. De‐energizetheinstallationundertestorwear suitable protective clothing when placing or removing
thecurrentclampfrom a testsetup.
19. Donotapply/removethecurrentclamp mayto/fromUNINSULATED HAZARDOUS LIVEconductorswhich
causeelectric electricshock, burn, orarcflash.
Termékspecifikációk
Márka: | Extech |
Kategória: | multiméter |
Modell: | MA440 |
Szüksége van segítségre?
Ha segítségre van szüksége Extech MA440, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók multiméter Extech
23 December 2024
19 Szeptember 2024
30 Augusztus 2024
25 Augusztus 2024
25 Augusztus 2024
25 Augusztus 2024
20 Augusztus 2024
15 Augusztus 2024
12 Augusztus 2024
11 Augusztus 2024
Útmutatók multiméter
- multiméter PeakTech
- multiméter Milwaukee
- multiméter Maxwell
- multiméter Emos
- multiméter Voltcraft
- multiméter Vimar
- multiméter Digitus
- multiméter GW Instek
- multiméter Owon
- multiméter Aim TTi
- multiméter Gossen Metrawatt
- multiméter Amiko
- multiméter Klein Tools
- multiméter Chauvin Arnoux
- multiméter Workzone
- multiméter Beha-Amprobe
- multiméter Qian
- multiméter Joy-It
- multiméter Testo
- multiméter Powerfix
- multiméter Biltema
- multiméter REV
- multiméter BENNING
- multiméter Alecto
- multiméter Yato
- multiméter Velleman
- multiméter TFA
- multiméter Monacor
- multiméter Elro
- multiméter Fluke
- multiméter Uni-T
- multiméter Metrix
- multiméter Abus
- multiméter Megger
- multiméter Testboy
- multiméter Sonel
- multiméter Wiha
- multiméter Schneider
- multiméter Kyoritsu
- multiméter Brandson
- multiméter Silverline
- multiméter Rigol
- multiméter Projecta
- multiméter Multimetrix
- multiméter Weidmüller
- multiméter Laserliner
- multiméter Appa
- multiméter Amprobe
- multiméter Ferm
- multiméter Tacklife
- multiméter Somogyi
- multiméter Profile
- multiméter Steren
- multiméter Flir
- multiméter Hager
- multiméter Clas Ohlson
- multiméter Etekcity
- multiméter Greenlee
- multiméter Högert
- multiméter Bruder Mannesmann
- multiméter Keithley
- multiméter Metrel
- multiméter Digi-tool
- multiméter Skandia
- multiméter Elma
- multiméter Hubinont
- multiméter Kewtech
- multiméter Strex
- multiméter Mastech
- multiméter MBS
- multiméter MGL Avionics
- multiméter PCE Instruments
- multiméter Micronta
- multiméter CEM
- multiméter Horex
- multiméter Cosinus
- multiméter Kurth Electronic
- multiméter Testec
- multiméter IWH
- multiméter Weltron
- multiméter Sanwa
- multiméter Rohde & Schwarz
- multiméter EEVBlog
- multiméter Kingcraft
- multiméter HT Instruments
- multiméter Caltek
- multiméter Elworks
- multiméter Bearware
- multiméter Noyafa
Legújabb útmutatók multiméter
3 Január 2025
1 Január 2025
29 December 2024
29 December 2024
29 December 2024
29 December 2024
22 December 2024
19 December 2024
17 December 2024
16 December 2024