Introduction
Thank you for selecting the Extech AUT500 Automotive Multimeter. The AUT500 is an Auto Range
Multimeter that measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency,
Diode, Continuity, RPM, Dwell, and Duty Cycle. The AUT500 also measures contact temperature via
supplied Thermocouple probe.
The AUT500 features a rugged design for heavy duty use. This device is shipped fully tested and
calibrated and, with proper use, will provide years of reliable service. Please visit our website
(www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer
Support.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages
may be present
Double insulation
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds (in this case) 600 VAC or VDC.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair any damage or replace the unit before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Always discharge capacitors and remove power from the device under test before performing
Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
WARNING
CAUTION
MAX
600V
AUT500-EU-EN v1.0 5/13
3
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
This device is not a toy and must not reach children’s hands. It contains hazardous objects as
well as small parts that the children could swallow. In case a child swallows any of them,
please contact a physician immediately
Do not leave batteries and packing material lying around unattended; they can be dangerous
for children if they use them as toys
In case the device is going to be unused for an extended period of time, remove the batteries
to prevent them from training
Expired or damaged batteries can cause cauterization on contact with the skin. Always,
therefore, use suitable hand gloves in such cases
See that the batteries are not short-circuited. Do not throw batteries into the fire.
DANGERS
Engines produce carbon monoxide which is odor reaction time, and can less, causes slower
lead to serious injury. When the engine is operating keep service areas well ventilated or
attach the vehicle exhaust system to the shop exhaust removal system.
Set the parking brake and block the wheels before testing or repairing the vehicle. It is
especially important to block the wheels on front-wheel drive vehicles; the parking brake does
not hold the drive wheels.
Wear an eye shield when testing or repairing vehicles.
Keep the meter away from spark plug and coil wires.
Exceeding the limits of this meter is dangerous. This will expose you to serious or possibly fatal
injury. Carefully read and understand the cautions and the specification limits of this meter.
Avoid electrical shock; do not touch the test leads, tips, or the circuit under test.
Do not try a voltage measurement with the test leads in the 20A or the mA terminal.
Choose the proper range and function for the measurement. Do not try voltage or current
measurements that may exceed the ratings marked on the Function/Range switch or terminal.
When measuring current, connect the meter in series with the load.
Never connect more than one set of test leads to the meter.
Disconnect the live test lead before disconnecting the common test lead.
The mA and the 20A terminals are protected by fuses. To avoid possible injury or damage, use
only in circuits limited to 400mA.

Termékspecifikációk

Márka: Extech
Kategória: multiméter
Modell: AUT500

Szüksége van segítségre?

Ha segítségre van szüksége Extech AUT500, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók multiméter Extech

Extech

Extech 380942 Útmutató

23 December 2024
Extech

Extech DM220 Útmutató

19 Szeptember 2024
Extech

Extech EX410A Útmutató

30 Augusztus 2024
Extech

Extech MA440 Útmutató

25 Augusztus 2024
Extech

Extech EX355 Útmutató

25 Augusztus 2024
Extech

Extech MA443 Útmutató

25 Augusztus 2024
Extech

Extech MG302 Útmutató

20 Augusztus 2024
Extech

Extech Ex 830 Útmutató

15 Augusztus 2024
Extech

Extech Ex 810 Útmutató

12 Augusztus 2024
Extech

Extech EX 710 Útmutató

11 Augusztus 2024

Útmutatók multiméter

Legújabb útmutatók multiméter

Uni-T

Uni-T UT33A Útmutató

3 Április 2025
Uni-T

Uni-T UT151A Útmutató

3 Április 2025
Uni-T

Uni-T UT171B Útmutató

3 Április 2025
Uni-T

Uni-T UT139B Útmutató

3 Április 2025
Uni-T

Uni-T UT139A Útmutató

3 Április 2025
Uni-T

Uni-T UT219E Útmutató

3 Április 2025
Uni-T

Uni-T UT89XD Útmutató

3 Április 2025
Proline

Proline 15186 Útmutató

26 Március 2025