Használati útmutató Etekcity Lasergrip 1022D
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Etekcity Lasergrip 1022D (2 oldal) a hőmérő kategóriában. Ezt az útmutatót 10 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/2

IMPORTANT: Read all the instructions in this manual. Failure
to comply with the instructions in this manual or use of the
device, in ways other than the ones mentioned in this manual,
may result in hazardous radiation exposure.
Safety Use & Care
Features & Specifications
Function Diagram
• Laser guided targeting for aiming precision
• Narrow distance-spot ratio for accurate results at greater distances
• Safely measure hazardous or inaccessible objects
• Standard 9V battery powers up to 12 hours of cumulative use
• Auto-off after 15 seconds of inactivity
• Measurement Range: -58°F ~ 1022°F (-50°C ~ 550°C)
• Accuracy: ±2% / ±2°C
• Resolution: 0.1°F / °C
• Maximum Output: < 1 mW
• Wavelength: 630 - 670 nm
• Distance-Spot Ratio: 12:1
• Response Time: < 500 ms
• Emissivity(Adjustable): 0.1 - 1.0
• Battery: DC 9V
1. LCD Display
2. Display Backlight On/Off
3. Laser Pointer/UP
4. Unit (°C/°F)/DOWN
5. Emissivity Adjustment Mode
6. Laser Hole
7. IR Sensor
8. Measurement Trigger
9. Battery Compartment
Operation
Surface Temperature Measurement
NOTE: The Lasergrip cannot measure the temperature of objects behind
glass. Inaccuracy may also occur when exposed to steam, dust or any
other contaminants in the air.
1. Once the battery is properly installed, press the measurement trigger to
activate the device.
2. Point the Lasergrip towards the surface of measurement.
3. Press and hold the measurement trigger and the laser will activate for
aiming guidance.
4. Keep holding the trigger as you move the Lasergrip if you wish to live
scan the surface area for temperature measurement.
5. Once the laser is pointed to the desired point of measurement, release
the trigger and the LCD display will lock the calculated temperature.
6. Press the measurement trigger once again to make another
measurement.
HOLD for continuous
temperature reading
RELEASE to lock the
temperature result
NOTE: The Lasergrip LCD will display ‘OH’ when the measured
temperature is above the measurable range, and will display ‘OL’ when the
measured temperature is below the measurable range.
NOTE: The Lasergrip cannot measure the temperature of objects behind
glass. Inaccuracy may also occur when exposed to steam, dust or any
other contaminants in the air.
The device warning and aperture safety
information are also labeled directly on
the device; the sticker is located on the
right side of the Lasergrip.
Any updates to the product information
(date of manufacturing and
manufacturer address) will be added as
adhesive overlays.
The device certification information is
labeled directly on the device. The
sticker is located on the left side of the
Lasergrip.
Warranty Information
Etekcity warrants all products to be of the highest quality in material,
craftsmanship, and service, effective from the date of purchase to the end
of the warranty period.
Etekcity will replace any product found to be defective due to
manufacturer flaws based on eligibility. Refunds are available within
the first 30 days of purchase. Refunds are only available to the original
purchaser of the product. This warranty extends only to personal use and
does not extend to any product that has been used for commercial, rental,
or any other use in which the product is not intended for. There are no
warranties other than the warranties expressly set forth with each product.
This warranty is non-transferrable. Etekcity is not responsible in any
way for any damages, losses, or inconveniences caused by equipment
failure by user negligence, abuse, or use noncompliant with the user
manual or any additional safety, use, or warnings included in the product
packaging and manual.
This warranty does not apply to the following:
• Damage due to abuse, accident, alteration, misuse, tampering, or vandalism.
• Improper or inadequate maintenance.
Distance-Spot Ratio
For the most accurate results, make sure the two guidance lasers overlap
at a single point. The space between the two lasers marks the the area of
measurement. Insufficient surface area will result in inaccurate results.
The recommended distance to hold the Lasergrip from the surface of
measurement is 14.17 in (36 cm). This creates a spot measurement area of
1.18 inches (3 cm) in diameter.
The Lasergrip 1022D measures surface temperature on the basis of
distance to spot diameter ratio (D:S). As the distance betweer the
thermometer and the surface increases, the total surface area measured
will also increase. With a distance to spot ratio of 12:1 the surface area
measured has a diameter of roughly 1/12 the distance.
If you encounter any issues or have any questions regarding your new
product, please contact our helpful Customer Support Team. Your
satisfaction is our goal!
Customer Support
Etekcity and its subsidiaries assume no liability for damage caused by the
use of the product other than for its intended use or as instructed in the
user manual. Some states do not allow this exclusion or limitation of
incidental or consequential losses so the foregoing disclaimer may not
apply to you. This warranty gives you specific legal rights and you may
also have other rights which may vary from state to state.
ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING THE
WARRANTY OF MERCHANTABILITY, ARE LIMITED TO THE PERIOD OF THE
LIMITED WARRANTY.
Additional 1-Year Warranty
You can extend your 1-year warranty by an additional year. Log onto
www.etekcity.com/warranty and enter your order number (for example,
from Amazon or Houzz) to register your new product for the extended
warranty.
If you are unable to provide the order number for your product, please
type a short note in the order number field along with the date you
received your product.
Defective Products & Returns
If your product proves defective within the specified warranty period,
please contact Customer Support via support@etekcity.com with your
order number. DO NOT dispose of your product before contacting us. Once
Customer Support has approved your request, please return the unit with
a copy of the invoice or your order number.
*Please have your order confirmation number ready before contacting
Customer Support.
Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806
USA
Toll Free: (855) 686-3835
Email: support@etekcity.com
Support Hours
Mon - Fri 9:00 am - 5:00 pm PST/PDT
Infrared Thermometer
Model No.: Lasergrip 1022D
Questions or Concerns?
(855)-686-3835 • support@etekcity.com
Thank you for purchasing the Lasergrip 1022D Infrared Thermometer by
Etekcity. This easy-to-use device lets you conveniently and accurately
measure surface temperatures from a distance without the need of any
direct contact. Should you have any questions or concerns, feel free to
contact our helpful customer support team toll-free at 855.686.3835 or
by email at support@etekcity.com.
WARNING: THIS DEVICE PRODUCES LASER RADIATION. USE CLASS 2
EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT LOOK
INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM WITH
OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER
PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO
NOT DISASSEMBLE THE DEVICE.
• DO NOT point the laser-light at another person or animal.
• DO NOT attempt to point laser-light at an aircraft.
• Avoid direct/indirect eye contact with the laser-beam. Laser radiation
may cause eye damage.
• DO NOT view the beam with optical instruments.
• In the vicinity of use, make any bystanders aware of the dangers of
looking directly into the laser beam.
• DO NOT allow children to operate the device.
• Use a 9V battery when replacing the battery within the device. Make
sure to insert the battery in accordance with the correct polarities.
• ALWAYS remove the batteries when cleaning the device.
• DO NOT use leaking batteries or dispose old batteries in fire.
• Remove the battery for storage if the device is not being used for a
prolonged period of time.
• DO NOT disassemble the device or tamper with internal components.
Doing so will void any warranty.
• DO NOT touch the lens or wipe it using anything other than a soft cloth
or cotton swab.
• Keep the thermometer away from electromagnetic fields produced by
objects such as arc welders and induction heaters.
• DO NOT expose the thermometer to direct sources of heat for extended
periods of time.
• The thermometer measures surface temperature, not internal
temperature. Do not use the Lasergrip as a reliable source to measure
body temperatures.
1. Low Battery
2. Laser On
3. Back-light On
4. Continue Scanning
5. °C / °F
6. Temperature Result
7. Max Temperature / Emissivity Result
8. Max Temperature Sian
9. Adjustable Emissivity Sign
Display Icon Key
Unit Conversion
To switch between units of temperature
measurement, press the °C/°F button at any time
while the Lasergrip is on.
Laser Activation
To activate and deactivate the laser, press the
laser pointer On/Off button at any time while the
Lasergrip is on.
Display Backlight Operation
To activate and deactivate the display backlight,
press the display backlight On/Off button at any
time while the Lasergrip is on.
Emissivity Adjustment &
Max Temperature
To adjust the emissivity value before
measurement, press the emissivity adjustment
mode button, then use the UP and DOWN
buttons to navigate to the desired value. You may
refer to the emissivity reference chart for correct
surface emissivity values. To transfer into Max
Temperature Mode, press the mode butt on again.
1. Open the battery compartment and remove the used battery. Dispose
the used battery properly.
2. Connect a new DC 9V battery, making sure it's under the correct
polarity.
3. Insert the battery into the compartment and close the compartment lid,
making sure the wiring is not being pinched by the compartment lid.
Battery Replacement
A low battery icon will appear on the LCD display when the Lasergrip's
battery power is running low. Immediately replace the battery when the
icon appears.
9V Battery
PAIR
Wiring is not
bulging out of the
compartment
Polarity facing
upward
Emissivity
FCC Declaration
The emissivity of a material is its efficiency in emitting thermal energy.
Non-reflective surfaces have a higher emissivity (closer to 1) than
reflective surfaces (closer to 0). Inaccurate results may occur when
measuring reflective surfaces such as glass, polished wood, and garnite.
To take accurate temperature measurement of reflective surfaces with
low emissivity, adjust the emissivity value before measurement using the
reference chart. Or, place a strip of masking tape over the surface and
allow for it to adjust to the temperature of the surface for approximately
30 minutes. Measure the surface, scanning the taped section, eliminating
the issue of inaccuracy.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received.
Including interference that may cause undesired operation.
Material Feature Emissivity Material Feature Emissivity
Emissivity Of Articles
Aluminium
Brass
Oxidized 0.3 0.98
0.02-0.04 0.20-0.60
0.5
0.7
0.02-0.05
0.70-0.90
0.85-0.95
0.85-0.920.75-0.80
0.83-0.90
0.96-0.98
0.95
0.95
0.98
0.80-0.90
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.94
0.94
0.94
0.5
0.80
0.90
0.90
0.9
0.96
0.90-0.98
0.90-0.96
0.92-0.96
0.89-0.91
0.7
0.90-0.95
0.96
0.85
0.97
0.90
0.93
0.93
0.95
Polished
Oxidized
Oxidized
Oxidized
Powered
Lackluster
Polished
Gold 0.01-0.10
Iron
Steel
Asbestos
Plaster
Asphalt
Rock
Wood
Charcoal
Carbon
Lacquerwork
Carbon Cement
Soap Bubble
Water
Snow
Ice
Frozen Foods
Ceramics
Limestone
Paint
Human Skin
Graphite
Plastic
Rubber
Plastic Cement
Concrete
Cement
Soil
Mortar
Brick
Marble
Textile
Paper
Sand
Clay
Sand
Glass
Textile
Heated Food
Plastic
Oil
Steel and iron
Wool
Lead
Natural
Oxidized
Non-
transparent
Oxidized
Package Contents
1 x Lasergrip 1022D
1 x 9V DC Battery
1 x User Manual
• Damage in return transit.
• Unsupervised use by children under 18 years of age.
Termékspecifikációk
Márka: | Etekcity |
Kategória: | hőmérő |
Modell: | Lasergrip 1022D |
Szüksége van segítségre?
Ha segítségre van szüksége Etekcity Lasergrip 1022D, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók hőmérő Etekcity

29 December 2024

15 Augusztus 2024

14 Augusztus 2024
Útmutatók hőmérő
- hőmérő PeakTech
- hőmérő Braun
- hőmérő Nedis
- hőmérő Milwaukee
- hőmérő Philips
- hőmérő Oregon Scientific
- hőmérő SilverCrest
- hőmérő Bosch
- hőmérő AEG
- hőmérő Emerio
- hőmérő Nokia
- hőmérő Omron
- hőmérő Bartscher
- hőmérő Tefal
- hőmérő Auriol
- hőmérő Emos
- hőmérő Voltcraft
- hőmérő Motorola
- hőmérő Beurer
- hőmérő Medisana
- hőmérő Omega
- hőmérő Thomson
- hőmérő Esperanza
- hőmérő Scala
- hőmérő Cuisinart
- hőmérő Speco Technologies
- hőmérő Owon
- hőmérő Duronic
- hőmérő Clatronic
- hőmérő Hama
- hőmérő Sanitas
- hőmérő Sencor
- hőmérő Techno Line
- hőmérő Innoliving
- hőmérő Citizen
- hőmérő TurboTronic
- hőmérő Inventum
- hőmérő Telefunken
- hőmérő Bresser
- hőmérő Klein Tools
- hőmérő Chauvin Arnoux
- hőmérő Microlife
- hőmérő Denver
- hőmérő Trevi
- hőmérő Beha-Amprobe
- hőmérő Elta
- hőmérő Orbegozo
- hőmérő Respekta
- hőmérő Joy-It
- hőmérő Extech
- hőmérő TrueLife
- hőmérő Testo
- hőmérő Powerfix
- hőmérő TriStar
- hőmérő ProfiCare
- hőmérő BeSafe
- hőmérő Alecto
- hőmérő Velleman
- hőmérő Terraillon
- hőmérő TFA
- hőmérő Lanaform
- hőmérő Leifheit
- hőmérő Melissa
- hőmérő Trotec
- hőmérő Eurochron
- hőmérő Pancontrol
- hőmérő Elro
- hőmérő InfiRay
- hőmérő Fluke
- hőmérő Uni-T
- hőmérő Olympia
- hőmérő Rossmax
- hőmérő ZKTeco
- hőmérő La Crosse Technology
- hőmérő A&D
- hőmérő Konig
- hőmérő GlobalTronics
- hőmérő Pyle
- hőmérő Testboy
- hőmérő Laica
- hőmérő IFM
- hőmérő Greisinger
- hőmérő Kyoritsu
- hőmérő Stanley
- hőmérő Vemer
- hőmérő Silverline
- hőmérő Taylor
- hőmérő Cotech
- hőmérő Ebro
- hőmérő Thermoval
- hőmérő Arendo
- hőmérő Beper
- hőmérő Optex
- hőmérő SereneLife
- hőmérő Salter
- hőmérő Topcom
- hőmérő Weber
- hőmérő Comelec
- hőmérő Homedics
- hőmérő Orava
- hőmérő Laserliner
- hőmérő TensCare
- hőmérő Hazet
- hőmérő Zeiss
- hőmérő Fysic
- hőmérő Quigg
- hőmérő Ade
- hőmérő AnD
- hőmérő Amprobe
- hőmérő ATN
- hőmérő Aponorm
- hőmérő Kruidvat
- hőmérő Easypix
- hőmérő Cresta
- hőmérő Marquant
- hőmérő Perel
- hőmérő Flir
- hőmérő AcuRite
- hőmérő Summer
- hőmérő Technoline
- hőmérő Vicks
- hőmérő Welch Allyn
- hőmérő BabyOno
- hőmérő Safety 1st
- hőmérő Inkbird
- hőmérő Boso
- hőmérő Clas Ohlson
- hőmérő Turbotech
- hőmérő Luvion
- hőmérő Irox
- hőmérő Reer
- hőmérő Waeco
- hőmérő Miniland
- hőmérő CaterChef
- hőmérő Ecomed
- hőmérő Save Demp
- hőmérő Comark
- hőmérő Fora
- hőmérő AGM
- hőmérő Beaba
- hőmérő Grado
- hőmérő La Crosse
- hőmérő Medel
- hőmérő Geratherm
- hőmérő Hartig And Helling
- hőmérő Pacom
- hőmérő Westfalia
- hőmérő Bioland
- hőmérő Global Tronics
- hőmérő Levita
- hőmérő Blue Circle Medical
- hőmérő Kerbl
- hőmérő Okoia
- hőmérő Silvergear
- hőmérő Uebe
- hőmérő Dittmann
- hőmérő Sensitec
- hőmérő TFA Dostmann
- hőmérő CDN
- hőmérő Emga
- hőmérő Hartmann
- hőmérő Premiumful
- hőmérő MostEssential
- hőmérő VDH
- hőmérő Telesystem
- hőmérő General
- hőmérő Arya
- hőmérő RK Technology
- hőmérő Mobi
- hőmérő TQC
- hőmérő Bintoi
- hőmérő Veroval
- hőmérő Jumper
- hőmérő Elem6
- hőmérő Pasha
- hőmérő Innovo
- hőmérő Delta Ohm
- hőmérő Guide
- hőmérő Neno
- hőmérő PCE Instruments
- hőmérő Knikker
- hőmérő FlinQ
- hőmérő AvaTemp
- hőmérő EasyLife
- hőmérő Alter
- hőmérő Unknown
- hőmérő Yummly
- hőmérő Eks
- hőmérő Gima
- hőmérő Aspen
- hőmérő Salva Tec
- hőmérő Radiant
- hőmérő Kuchenprofi
- hőmérő WBTT
- hőmérő Welby
- hőmérő Prologue
- hőmérő ClimeMET
- hőmérő Bearware
- hőmérő Senseca
- hőmérő A&D Medical
- hőmérő Alphamed
Legújabb útmutatók hőmérő

10 Április 2025

8 Április 2025

7 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

2 Április 2025

2 Április 2025

1 Április 2025