Használati útmutató ETC Irideon FPZ

ETC Lampa Irideon FPZ

Olvassa el alább 📖 a magyar nyelvű használati útmutatót ETC Irideon FPZ (22 oldal) a Lampa kategóriában. Ezt az útmutatót 11 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/22
Part Number: 7191M1200-1.0.1 Rev: D
Released: 2019-06
Irideon FPZ
User Manual
V
V
V
VVersion 1.0
ersion 1.0
ersion 1.0
ersion 1.0ersion 1.0
To view a list of ETC trademarks and patents, go to
etcconnect.com/ip
etcconnect.com/ip
etcconnect.com/ip
etcconnect.com/ipetcconnect.com/ip
.
All other trademarks, both marked and not marked, are the property of
their respective owners.
ETC intends this document, whether printed or electronic, to be
provided in its entirety.
Table of Contents
Table of Contents i
Introduction . . . . . . . . . . . . . . . . . . . . . . . 1
Specifications. . . . . . . . . . . . . . . . . . . . . . . 3
Basic Assembly. . . . . . . . . . . . . . . . . . . . . . 4
Installation. . . . . . . . . . . . . . . . . . . . . . . . . 4
Install Track-Mounted Fixture. . . . . . . . . . . . . 4
Install Canopy Fixture (DMX variant) . . . . . . . 5
Install the Voltage Barrier
(DMX variant) . . . . . . . . . . . . . . . . . . . . . . . 5
Connect Canopy Wiring (DMX variant) . . . 6
Install the Mounting Plate and
Complete the Wiring (DMX variant) . . . . . 8
Install Canopy Fixture (0–10 V and DALI
variants) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Install Portable Fixture with C-clamp . . . . . . 13
Install Portable Fixture on Unistrut Track . . 14
Connect Cables to Portable Fixture . . . . . . . 14
Portable Fixture DMX Pinout . . . . . . . . . . 15
Set the DMX Address on the Fixture . . . . . . 15
Alternative DMX Addressing Functions . . 17
Adjust the Local Intensity . . . . . . . . . . . . . 17
Initial Power Up . . . . . . . . . . . . . . . . . . . . . . . 18
Status LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
User Manual 1
Introduction
Introduction
Introduction
IntroductionIntroduction
The Irideon FPZ takes the beauty and punch of the Source Four Mini beam and
puts it into a fixture designed to work in any architectural environment.
The Irideon FPZ has three available mounting options:
Track-mount—For use with the DataTrack track system.
Portable—Includes a miniature C-clamp and yoke-mounted driver, and
has a permanently installed power cord with 3-prong Edison connector.
Region-specific connectors are available. Contact ETC for available
options. Use L5-15 plugs on branch circuits with L5-15 receptacles only.
Canopy—Available in three different control variants:
- 0–10 V
- DALI
- DMX
Note:
Note:
Note:
Note:Note:
The miniature C-clamp for the portable fixture is
available only in non-EU markets. Within the EU, use an
M12 bolt to secure a C-clamp (provided separately) to the
fixture.
Portable
Portable
Portable
PortablePortable
Track-mount
Track-mount
Track-mount
Track-mountTrack-mount
Canopy
Canopy
Canopy
CanopyCanopy
User Manual 3
Spe
Spe
Spe
SpeSpecific
cific
cific
cificcification
ation
ation
ationations
s
s
ss
Physical
Physical
Physical
PhysicalPhysical
Steel yoke with 0.406” (10.3 mm) diameter
mounting hole
Rotating shutter assembly ±175°
E-size gobo pattern holder (included) 1-1/2”
(37.5 mm) with a 1” (25.4 mm) image area
IP20 rated
Zoom range to suit a variety of throw
distances
Captive accessory slot for pattern holder
(included)
Locking, stainless steel, full hard shutters in
a tri-plane assembly, 0.40 mm (A301 grade)
Magnetically held integrated media holder
for 2.6” (66 mm) diameter color media or
diffusion or 1.75 mm-thickness dichroic
glass
Track-mount fixture:
- Compatible and ETL-listed for DataTrack
(EUTRAC) brand track
- DataTrack color matching track adapter
included
Portable fixture:
- C-clamp (included in non-EU markets)
- Optional accessory for Unistrut
®
mounting (order separately, part number
7191K1000)
Canopy fixture:
- Can be installed directly on 4” and
4-11/16” backboxes, or on backboxes
with round cover plates
- Not for installation on 1-gang backboxes
or trim rings
Electrical
Electrical
Electrical
ElectricalElectrical
Power at full intensity: 20 W (typical),
24 W (maximum)
Input voltage options:
- Track-mount and portable: 100–240 V,
50/60 Hz
- Canopy (0–10 V and DALI): 120–277 V,
50/60 Hz
- Canopy (DMX): 100–277 V, 50/60 Hz
Portable fixture: 6 ft power cable hard-wired
to fixture with mains connector options of
NEMA 5-15P, Schuko, or UK
Inrush (first half-cycle) for 0–10 V and DALI
canopy fixtures:
- 120 V: 2 A
- 240 V: 5 A
- 277 V: 6 A
Inrush (first half-cycle) for all other fixtures:
- 120 V: 11 A
- 240 V: 24 A
- 277 V: 28 A
All variants require power from a non-
dimmable source
LEDs
LEDs
LEDs
LEDsLEDs
Cree LED source
- Irideon FPZ 2700 K Gallery: 90+ CRI
- Irideon FPZ 3000 K: 80+ CRI
- Irideon FPZ 3000 K Gallery: 90+ CRI
- Irideon FPZ 4000 K: 80+ CRI
- Irideon FPZ 5000 K: 80+ CRI
Long-life LED: 70,000 hours L70 lumen
maintenance
Optical
Optical
Optical
OpticalOptical
Built-in zoom optics
(25–50 degree field-angle)
Beam edge continually adjustable
hard to soft
Projector-quality, high-contrast lenses
Thermal
Thermal
Thermal
ThermalThermal
0°C to 40°C (32°F to 104°F) ambient operating temperature
4 Irideon FPZ
Basic Assembly
Basic Assembly
Basic Assembly
Basic Assembly Basic Assembly
Installation
Installation
Installation
Installation Installation
Install T
Install T
Install T
Install TInstall Track-
rack-
rack-
rack-rack-
Mounted Fixture
Mounted Fixture
Mounted Fixture
Mounted FixtureMounted Fixture
1: Insert the DataTrack
adapter into the track.
The adapter only fits into
the track one way with
the tabs nesting into the
track’s groove.
2: Rotate the locking
mechanisms to lock the
adapter into place.
3: Use the circuit selection
lock to select the circuit.
The desired circuit
number should point toward the center of the adapter.
WARNING:
WARNING:
WARNING:
WARNING:WARNING:
When using the circuit selection lock, ensure that the
When using the circuit selection lock, ensure that the
When using the circuit selection lock, ensure that the
When using the circuit selection lock, ensure that the When using the circuit selection lock, ensure that the
selected circuit is a constant
selected circuit is a constant
selected circuit is a constant
selected circuit is a constant selected circuit is a constant power circuit. Dialing into a
power circuit. Dialing into a
power circuit. Dialing into a
power circuit. Dialing into a power circuit. Dialing into a
dimmable circuit may cause fixture damage that will void
dimmable circuit may cause fixture damage that will void
dimmable circuit may cause fixture damage that will void
dimmable circuit may cause fixture damage that will void dimmable circuit may cause fixture damage that will void
the ETC warranty.
the ETC warranty.
the ETC warranty.
the ETC warranty.the ETC warranty.
Yoke
Yoke
Yoke
YokeYoke
Integrated media
Integrated media
Integrated media
Integrated mediaIntegrated media
holder
holder
holder
holderholder
Shutters x4
Shutters x4
Shutters x4
Shutters x4Shutters x4
Beam zoom an
Beam zoom an
Beam zoom an
Beam zoom anBeam zoom and
d
d
d d
focus knobs
focus knobs
focus knobs
focus knobsfocus knobs
Pattern holder
Pattern holder
Pattern holder
Pattern holderPattern holder
slot
slot
slot
slotslot
(Illustration shows fixture body only)
(Illustration shows fixture body only)
(Illustration shows fixture body only)
(Illustration shows fixture body only)(Illustration shows fixture body only)
Circuit
Circuit
Circuit
Circuit Circuit
selection lock
selection lock
selection lock
selection lockselection lock
Locking
Locking
Locking
Locking Locking
mechanism
mechanism
mechanism
mechanismmechanism
User Manual 5
Install Canopy Fixture (DMX variant
Install Canopy Fixture (DMX variant
Install Canopy Fixture (DMX variant
Install Canopy Fixture (DMX variantInstall Canopy Fixture (DMX variant)
)
)
))
Install the V
Install the V
Install the V
Install the VInstall the Voltage Barrie
oltage Barrie
oltage Barrie
oltage Barrieoltage Barrier (DMX va
r (DMX va
r (DMX va
r (DMX var (DMX variant)
riant)
riant)
riant)riant)
The DMX variant of the canopy fixture includes a voltage barrier to separate
the data network from the line voltage inside the backbox. Voltage barriers are
provided for both 4” and 4-11/16” backboxes.
Install the voltage barrier in the backbox with
the provided screw, separating the power
side from the data side (see image at right).
Note:
Note:
Note:
Note:Note:
The canopy fixture can be installed directly on 4” and
4-11/16” backboxes, or on backboxes with round cover
plates. The canopy fixture cannot be installed on 1-gang
backboxes or trim rings.
CAUTION:
CAUTION:
CAUTION:
CAUTION:CAUTION:
DMX control is a Class 2 circuit. DMX wiring cannot be
run through the same conduit as line voltage power-
supply conductors.
Separate the line voltage from the data side in the
backbox. Install the voltage barrier provided by ETC.
6 Irideon FPZ
Connect Canopy Wiring (DMX variant)
Connect Canopy Wiring (DMX variant)
Connect Canopy Wiring (DMX variant)
Connect Canopy Wiring (DMX variant)Connect Canopy Wiring (DMX variant)
Cable preparation instructions for DMX termination are included in the
termination kits, and are also available for free download at etcconnect.com
etcconnect.com
etcconnect.com
etcconnect.cometcconnect.com.
1: Remove the adhesive tape or fasteners securing the mounting plate to
the fixture to free the mounting plate from the canopy enclosure.
2: Are you flush-mounting the fixture or surface-mounting the fixture?
Flush-mounting
Flush-mounting
Flush-mounting
Flush-mountingFlush-mounting:
:
:
:: Continue to step 3.
Surface-mounting:
Surface-mounting:
Surface-mounting:
Surface-mounting:Surface-mounting:
Position the cover
plate on top of the
mounting plate
before wiring the
fixture. The cover
plate is required
when the interior of the canopy enclosure could be exposed after
installation with only the mounting plate (the mounting surface is
smaller than the canopy enclosure).
3: Terminate DMX/RDM input from the
control source to the backbox.
If using Belden 9729:
a: See the
DMX Cable Preparation
for Screw Termination Setup
Guide
for instructions to prepare
and terminate Belden 9729 for
DMX input cable to the screw
terminal connector.
b: Install the screw terminal
connector with wires terminated
to the DMX/RDM Input receptacle
on the termination board.
WARNING:
WARNING:
WARNING:
WARNING:WARNING:
RISK OF ELECTRIC SHOCK! Install the cover plate as
RISK OF ELECTRIC SHOCK! Install the cover plate as
RISK OF ELECTRIC SHOCK! Install the cover plate as
RISK OF ELECTRIC SHOCK! Install the cover plate as RISK OF ELECTRIC SHOCK! Install the cover plate as
directed below for installations where the
directed below for installations where the
directed below for installations where the
directed below for installations where the directed below for installations where the interior of the
interior of the
interior of the
interior of the interior of the
canopy enclosure could be exposed after install
canopy enclosure could be exposed after install
canopy enclosure could be exposed after install
canopy enclosure could be exposed after installcanopy enclosure could be exposed after installation
ation
ation
ation ation
with only the mounting plate. For example, ins
with only the mounting plate. For example, ins
with only the mounting plate. For example, ins
with only the mounting plate. For example, inswith only the mounting plate. For example, install the
tall the
tall the
tall the tall the
cover plate when installing to a surface-mount backbox.
cover plate when installing to a surface-mount backbox.
cover plate when installing to a surface-mount backbox.
cover plate when installing to a surface-mount backbox. cover plate when installing to a surface-mount backbox.
Mounting plate
Mounting plate
Mounting plate
Mounting plateMounting plate
Cover plate
Cover plate
Cover plate
Cover plate Cover plate
(if
(if
(if
(if(if needed for
needed for
needed for
needed for needed for
surface-mounting)
surface-mounting)
surface-mounting)
surface-mounting)surface-mounting)
From a DMX/RDM source
Data – (Black)
Data + (Red)
Belden 9729 (or equivalent) wire
termination to screw connector
4 to 8 = n/c
COM
User Manual 7
If using Category 5:
a: See the
Cat5 Cable Preparation for
IDC Termination Setup Guide
for
instructions to prepare and
terminate Category 5 for DMX/RDM
input cable to the insulation
displacement connector.
b: Install the IDC connector with wires
terminated to the DMX/RDM Input
receptacle on the termination board.
4: Optionally, terminate DMX/RDM thru to
the next device in the DMX data run.
Up to 32 DMX/RDM devices can be
daisy-chained together per data run.
a: See the specific termination setup guide for the type of cable used
(either Belden 9729 or Category 5) in the installation. Termination
kits are ordered separately.
b: Install the connector with wires terminated to the DMX/RDM Thru
receptacle on the termination board.
5: Connect the building ground wire to the power block on the fixture.
6: Following the label on the mounting plate, attach the power wires to
the power block.
Data – (ORG)
Data + (W/ORG)
Cat5 (or equivalent) wire
termination to IDC connector
COM
BRN
GRN
W/GRN
BLU
W/BLU
DMX
DMX
DMX
DMX DMX
termination
termination
termination
terminationtermination
board
board
board
boardboard
Power block
Power block
Power block
Power blockPower block
8 Irideon FPZ
Install the Mounting Plate and Complete the
Install the Mounting Plate and Complete the
Install the Mounting Plate and Complete the
Install the Mounting Plate and Complete the Install the Mounting Plate and Complete the
Wiring (DM
Wiring (DM
Wiring (DM
Wiring (DMWiring (DMX variant)
X variant)
X variant)
X variant)X variant)
1: Secure the mounting plate (or the
combination of mounting plate and
cover plate for surface-mounting) to
the installed backbox, positioning
the plate so that the power side and
data side are separated by the
voltage barrier in the backbox. See
Install the Voltage Barrier (DMX
Install the Voltage Barrier (DMX
Install the Voltage Barrier (DMX
Install the Voltage Barrier (DMX Install the Voltage Barrier (DMX
variant)
variant)
variant)
variant)variant)
on
page 5
page 5
page 5
page 5page 5
.
For this structure...
For this structure...
For this structure...
For this structure...For this structure... ...secure mounting plate using:
...secure mounting plate using:
...secure mounting plate using:
...secure mounting plate using:...secure mounting plate using:
4-11/16” backbox Large oval slots (see 1 above)
4” backbox Small oval slots (see 2 above)
Canopy
Canopy
Canopy
Canopy Canopy
screw
screw
screw
screwscrew hole
hole
hole
holehole
Mounting plate
Mounting plate
Mounting plate
Mounting plate Mounting plate
(DMX variant)
(DMX variant)
(DMX variant)
(DMX variant)(DMX variant)
2
2
2
22 1
1
1
11
2
2
2
22
1
1
1
11
User Manual 9
5: Terminate DMX/RDM data signal for the last DMX/RDM device in the
data run by setting the termination switch to ON (to the right, as shown
below). All other devices in the data run should retain the default
setting for the termination switch (OFF).
6: Following the label on the mounting plate, attach the power wires to
the power block.
7: Use the canopy screws to secure
the fixture to the mounting plate.
CAUTION:
CAUTION:
CAUTION:
CAUTION:CAUTION:
Make sure that the
wiring is clear of the
mounting plate before
you secure the fixture.
Hook
Hook
Hook
HookHook
2: Use the hook in the canopy enclosure to hang the
fixture from the mounting plate while you complete
the fixture wiring.
3: If desired, manually set the DMX address on the
fixture using the three addressing dials in the canopy.
See
Set the DMX Address on the Fixture
Set the DMX Address on the Fixture
Set the DMX Address on the Fixture
Set the DMX Address on the FixtureSet the DMX Address on the Fixture
on
page 15
page 15
page 15
page 15page 15
.
4: Connect the pre-wired DMX connector on the fixture
to the mated connector on the mounting plate
(shown below).
ON
Mounting plate
Mounting plate
Mounting plate
Mounting plate Mounting plate
DMX
DMX
DMX
DMXDMX connec
connec
connec
connecconnector
tor
tor
tortor
Termination switch
Termination switch
Termination switch
Termination switchTermination switch
Power block
Power block
Power block
Power blockPower block
Canopy
Canopy
Canopy
Canopy Canopy
screws
screws
screws
screwsscrews

Termékspecifikációk

Márka: ETC
Kategória: Lampa
Modell: Irideon FPZ

Szüksége van segítségre?

Ha segítségre van szüksége ETC Irideon FPZ, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Lampa ETC

ETC

ETC Irideon FPZ Útmutató

23 Augusztus 2024
ETC

ETC Desire D22 Útmutató

23 Augusztus 2024
ETC

ETC Source Four LED Útmutató

23 Augusztus 2024
ETC

ETC Irideon WLZ Útmutató

23 Augusztus 2024

Útmutatók Lampa

Legújabb útmutatók Lampa