1
Open and lift the front panel up to an angle to reach
the emergency button.
For heating model, press the emergency button at first
time, the unit will operate in COOL mode. Press at
second time within 3 seconds, the unit will operate in
HEAT mode. Press at third time after 5 seconds, the
unit will turn off.
For cooling only model, press the emergency button
at first time, the unit will operate in COOL mode.
Press again, the unit will turn off.
If the remote controller fails to work or maintenance
necessary, proceed as following:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Remote controller DISPLAY
Meaning of symbols on the liquid crystal display
5
COOLING indicator
DEHUMIDIFYING indicator
FAN ONLY OPERATION indicator
HEATING indicator
SIGNAL RECEPTION indicator
TIMER OFF indicator
TIMER ON indicator
AUTO FAN indicator
LOW FAN SPEED indicator
MIDDLE FAN SPEED indicator
HIGH FAN SPEED indicator
SLEEP indicator
FLAP SWING indicator
15 TUBRO indicator
16
17
ECO indicator
CLOCK indicator
18
Zone Follow indicator
AUTO mode indicator
Meaning
No. Symbols
10
11
REMOTE CONTROL
Signal
receptor
+
+
+
Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller,
by sliding it in the direction of the arrow.
Install the batteries according the direction (+and -)shown on the Remote
Controller.
Reinstall the battery cover by sliding it into place.
Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable
batteries . Replace the old batteries with new ones of the same
type when the display is no longer legible.
Do not dispose batteries as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
NOTE:if you adjust the remote controller in cooling mode,
it will not be possible to activate the heating function in units with
heating pump . you need to take out the batteries and repeat the
procedure described above.
1. Direct the remote controller toward the Air conditioner.
2. Check that there are no objects between the remote control
and the Signal receptor in the indoor unit.
3. Never leave the remote controller exposed to the rays of the sun.
4. Keep the remote controller at a distance of at least 1m from the
television or other electrical appliances.
Recommendations for locating and using the remote controller holder (if present)
The remote controller be kept in a wall-mounted holder
Refer to picture 2:
When you insert the batteries for the first time in the remote
controller or if you change them, you need to program the remote
controller of only cooling or cooling and heating.
When you insert the batteries, the symbols ( ) and
( ) start fashing. If you push whatever button when
the symbol ( ) is displayed, the remote controller is
adjusted in only cooling mode . If you push whatever button when
the symbol ( ) is displayed , the remote controller is
adjusted in Cooling and heating mode.
COOL
HEAT
COOL
HEAT
Refer to picture 1:
i. When you open the battery cover, you can see a DIP switch on
the cover back.l
Ii. NOTE:After adjusting the function, you need to take
out the batteries and repeat the procedure described above.
DIP switch on position
Function
The remote controller is adjusted in degree celsius
The remote controller is adjusted in only cooling mode
The remote controller is adjusted in cooling and heating mode
The remote controller is adjusted in degree fahrenheit.
Cool
Heat
C
F
Remote controller holder
Mo de
F
an
E
co
Te
mpS
w
ing
Time
r
D
is
pla y
S
le
ep
M
ild ew Tu
r
bo
H
ealth
Mo de
F
an
E
co
Tem pS
w
ing
Timer
Di
s
pla y
S
leep
M
ild ew T
ur
boHe
alth
M
ode
Fa
n
E
co
Temp Swin
g
Tim
e
r
Disp
la
y
Sleep
Mute Tur b
oI Fe
e
l
OPERATING INSTRUCTIONS
Filter
Heat
Fan
Exchanger
The direction of the air outlet is motorized up and down
by flaps, and manually moved right and left by the vertical
deflectors, for some models, the vertical deflectors could be
controlled by motor as well.
The air sucked by the fan enters from the grill and
passes through the filter, then it is cooled/dehumidified
or heated through the heat exchanger.
Fan
12
SWING CONTROL OF THE AIR FLOW
flaps
flap
movement Deflectors
The air outlet flow is uniformly dist-
ributed in the room.
It is possible to position the direction
of the air in the optimal.
In cooling mode , orient the flaps in horizontal
direction;
In heating mode, orient the flaps downward as
the warm air tends to rise.
The deflectors are positioned manually and placed un-
der the flaps .They allow to direct the air flow rightw-
ard or leftward.
Never position Flaps manually, the delicate mech-
anism might be seriously damaged!
Never poke fingers, sticks or other objects in the air
inlet or outlet vents. Such accidental contact with live
parts might cause unforeseeable damage or hurt.
This adjustment must be done while the appliance
is switched off.
SWING
The key activates the motorized deflectors ,
the air flow is directed alternatively from left to right.
(Optional function, depends on the models)
SWING
The key activates the FLAP ,
the air flow is directed alternatively from
up to down .In order to guarantee an even
diffusion of the air in the room.
SWING
OPERATING INSTRUCTIONS
13
COOLING MODE
The cooling function allows the air condit-
ioner to cool the room and at the same time
reduces Air humidity.
COOL
To activate the cooling function ( COOL ) , press the
MODE button until the symbol ( COOL )
appears on the display.
HEATING MODE
The cooling function is activated by setting the button
or at a temperature lower than that of the room.
To optimize the function of the Air conditioner, adjust
the temperature (1) , the speed (2) and the direction
of the air flow (3) by pressing the button indicated.
HEAT
The heating function allows the air conditi-
oner to heat the room.
To activate the heating function ( HEAT ) , press the
MODE button until the symbol ( HEAT )
appears on the display.
With the button or set a temperature higher than
that of the room..
To optimize the function of the Air conditioner adjust
the temperature ( 1 ), the speed ( 2 ) and the direction
of the air flow ( 3 ) by pressing the button indicated
In HEATING operation, the appliance can automatically
activate a defrost cycle, which is essential to clean the
frost on the condenser so as to recover its heat exchange
function.This procedure usually lasts for 2-10 minutes
during defrosting,indoor unit fan stop operation.
After defrosting ,it resumes to HEATING mode
automatically.
If the appliance is fitted with a electrical heater,
which delays appliance to startup in a few seconds
to ensure an immediate output of hot air (Optional ,
depends on the model).
COOL
HEAT
* This function does not available in cooling only model.
OPERATING INSTRUCTIONS
14
POWER SLEEP TIMER RUN
Indoor display
TIMER MODE----TIMER OFF
TIMER MODE----TIMER ON
POWER SLEEP TIMER RUN
Indoor display
TIMER
To set the time of the air conditioner
To program the automatical switching-on time, the
appliance should be power off.
Press TIMER at the fist time , set the temperature with
pressing the button or ;
Press TIMER at the second time , set the rest time with
pressing the button or ;
Press TIMER at the third time, confirm the setting, then
the rest time to next automatical switching-on could be
read on the display.
NOTE !
Before proceeding with the time: program the working
mode with the button MODE (2) and the fan speed
with the button FAN (3) . Switch the conditioner
off (with the key ON/OFF ).
TIMER
To set the automatic switching-off of
the air conditioner
The timed stop is programmed by pressing TIMER ,
Set the rest time by pressing the or ,until the rest button
time displayed is to your demand then press again. TIMER
Note:To cancel the set function ,press the TIMER
button again.
Note:To cancel the set function, press the TIMER
button again.
Note:In case of power off,it is necessary to set TIMER
ON again
Note:In case of power off,it is necessary to set TIMER
OFF again
Note:
When the time is set correctly on the
remote, the timer function can be used
and set in half hour increments.
TIMER ON
TIMER OFF
OPERATING INSTRUCTIONS
15
FAN
The conditioner works in only
ventilation.
To set the FAN mode , Press MODE until
( FAN ) appears in the display.
While pressing FAN button the speed changes
in the following sequence: LOW/ MEDIUM/HIGH
/AUTO in FAN mode.
The remote control also stores the speed that was set
in the previous mode of operation.
In mode (automatic) the air conditioner auto-AUTO
matically chooses the fan speed and the mode of
operation (COOLING or HEATING).
This function reduces the humid-
ity of the air to make the room
more comfortable.
To set the DRY mode , Press MODE untill
( DRY ) appears in the display . An automatic
function of alternating cooling cycles and air fan
is activated.
DRY
FAN MODE
DRY MODE
FAN
DRY
OPERATING INSTRUCTIONS
16
Ambient temp Auto temp.
20 23
23
26
20 ~26
Operation mode
HEATING ( FOR HEAT PUMP TYPE)
DRY
COOL
18
FAN (FOR COOL ONLY TYPE)
To optimize the function of the air conditioner, adjust
the temperature(only 2 )(1), the speed (2) and the
direction of the air flow (3) by pressing the buttons
indicated
To activate the SLEEP mode of operation, press the
SLEEP button on the remote controller until the sym-
bol ( ) appears on the display.SLEEP
SLEEP
The function SLEEP automatically adjusts the
temperature to make the room more comfortable
during the night . In cooling or dry mode , the set
temperature will automatically raise by1 every
60 minutes, to achieve a total rise of 2 during the
first 2 hours of operation.
In heating mode the set temperature is gradually
decreased by 2 during the first 2 hours of operation.
After 10 hours running in sleep mode the air conditio-
ner is swicthed off automatically.
AUTO MODE
POWER SLEEP TIMER RUN
Indoor display
SLEEP MODE
AUTO Automatic mode.
To activate the (automatic) mode of operation, AUTO
press the MODE button on the remote controller until
the symbol ( ) appears on the display. AUTO
In mode the fan speed and the temperatureAUTO
are set automatically according to the room temperature
(tested by the temperature sensor which is incorporated
in the indoor unit).
AUTO
Turbo mode.
TURBO MODE
To activate the TURBO mode of operation,
press the TURBO button on the remote control until
the symbol appears in the display.
In cooling mode, press this button, the unit will give
the maximum cooling temperature with 16
In heating mode, press this button, the unit will give
the maximum heating temperature with 31
Eco mode.
ECO MODE
To activate the ECO (economic) mode of operation.
Press the ECO button on the remote controller until the
symbol appears in the display.
In cooling mode, the temperature will increase 2 on
the base of setting temperature, in the heating mode, the
temperature will decrease 2 on the base of setting
temperature. Press again, the air conditioner switched
off ECO mode automatically.The SUPER mode and
ECO mode can t work together.
ECO
1
TURBO
20
INSTALLATION MANUAL---Important considerations
Important Considerations
The air conditioner you buy must be installed by professional personnel and the
Installation manual is used only for the professional installation personnel! The
installation specifications should be subject to our after-sale service regulations.
When filling the combustible refrigerant, any of your rude operations may cause
serious injury or injuries to human body or bodies and object or objects.
A leak test must be done after the installation is completed.
It is a must to do the safety inspection before maintaining or repairing an air
conditioner using combustible refrigerant in order to ensure that the fire risk is reduced
to minimum.
It is necessary to operate the machine under a controlled procedure in order to ensure
that any risk arising from the combustible gas or vapor during the operation is reduced
to minimum.
Requirements for the total weight of filled refrigerant and the area of a room to be
equipped with an air conditioner (are shown as in the following Tables GG.1 and GG.2)
22
INSTALLATION MANUAL---Important considerations
Installation Safety Principles
1. Site Safety
2. Operation Safety
Open Flames Prohibited Ventilation Necessary
Open Flames Prohibited
Mind Static Electricity Must wear protective clothing and anti-static gloves Don`t use mobile phone
3. Installation Safety
Refrigerant Leak Detector
Appropriate Installation
Location
The left picture is the schematic diagram of a refrigerant leak detector.
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant R290 should be free from open fire or
welding, sm oking, drying oven or any other heat source higher than 370? which easily produces open fire; the sites
for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding,
smoking, drying oven or any other heat source higher than 548? which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static
clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the
indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or
explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, it is necessary to immediately turn off the valve of
the outdoor unit and all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the
product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited
to weld the refrigerant pipe or conduct other operations on the user's site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen
cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit.
INSTALLATION MANUAL---Important considerations
23
Special Tools
Tool Name Requirement(s) for Use
Mini Vacuum Pump
Filling Device
Leak Detector
Concentration Detector
Pressure Gauge
Fire Extinguisher
It should be an explosion-proof vacuum pump; can ensure certain precision and its
vacuum degree should be lower than 10Pa.
It should be a special explosion-proof filling device; have certain precision and its
filling deviation should be less than 5g.
It should be calibrated regularly; and its annual leak rate should not exceed 10g.
A) The maintenance site should be equipped with a fixed-type combustible
refrigerant concentration detector and connected to a safeguard alarm system;
its error must be not more than 5%.
B) The installation site should be equipped with a portable combustible refrigerant
concentration detector which can realize two-level audible and visual alarm;
its error must be not more than 10%.
C) The concentration detectors should be calibrated regularly.
D) It is necessary to check and confirm the functions before using the concentration
detectors.
A) The pressure gauges should be calibrated regularly.
B) The pressure gauge used for Refrigerant 22 can be used for Refrigerants R290
and R161; the pressure gauge used for R410A can be used for Refrigerant 32.
It is necessary to carry fire extinguisher(s) when installing and maintaining an air
conditioner. On the maintenance site, there should be two or more kinds of dry
powder, carbon dioxide and foam fire extinguishers and that such fire extinguishers
should be placed at stipulated positions, with eye-catching labels and in handy
places.
INSTALLATION MANUAL---Selecting the Installation Place
condensed water drain pipe
150
150
150
Sleeve
insulating covering
electrical cable
Mounting plate
Do not install the outdoor unit near sources of heat,
steam or flammable gas.
Do not install the unit in too windy or dusty places.
Do not install the unit where people often pass.Select
a place where the air discharge and operating sound
will not disturb the neighbours.
Avoid installing the unit where it will be exposed
to direct sunlight ( other wise use a protection , if
necessary, that should not interfere with the air flow).
Reserve the spaces as shown in the picture for the air to
circulate freely.
Install the outdoor unit in a safe and solid place.
If the outdoor unit is subject to vibration, place rubber
gaskets onto the feet of the unit..
water drain pipe
300
500
2000
300
minimum space to be reserved (mm) showing
in the picture
500
Installation Diagram
24
INDOOR UNIT
OUTDOOR UNIT
The purchaser must ensure that the person and/or company who is to install, maintain or repair this air
conditioner has qualifications and experience in refrigerant products.
Install the indoor unit on a strong wall that is not subject
to vibrations.
The in let and outlet ports should not be obstructed:the
air should be able to blow all over the room.
Do not install the unit near a source of heat , steam,or
flammable gas.
Install the unit near an electric socket or private circuit.
Do not install the unit where it will be exposed to
direct sunlight.
Select a site where the condensed water can be easily drained
out, and where it is easily connected to outdoor unit.
Check the machine operation regularly and reserve the
necessary spaces as shown in the picture.
Select a place where the filter can be easily taken out.
INSTALLATION MANUAL---Installation of the Indoor unit
50
5mm
Note : Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space reserved around the units
To install, proceed as follows:
The hole must slope downwards towards the exterior
Note : The shape of the mounting plate may be different
from the one above, but installation method is similar .
Indoors Outdoors
Front panel
Terminal block cover
wiring diagram
25
Installation of the mounting plate
Drilling a hole in the wall for the piping
Electrical connections---Indoor unit
Do not install your air conditioner in a
wet room such as a bathroom or laundry etc
The installation site should be 250cm or more
above the floor.
1 Always mount the rear panel horizontally and vertically
2. Drill 32 mm deep holes in the wall to fix the
plate;
3. Insert the plastic anchors into the hole;
4 .Fix the rear panel on the wall with provided tapping screws
5.Be sure that the rear panel has been fixed firmly enough
to withstand the weight
1. Make the piping hole ( 55) in the wall at a slight
downward slant to the outdoor side.
2. Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
1. Open the front panel.
2. Take off the cover as indicated in the piciure ( by
removing a screw or breaking the hooks).
3. For the electrical connections, see the circuit diagram
on the right part of the unit under the front panel.
4. Connect the cable wires to the screw terminals by
following the numbering ,Use wire size suitable to
the electric power input (see name plate on the unit)
and according to all current national safety code
requirements.
The cable connecting the outdoor and indoor units
must be suitable for outdoor use.
The plug must be accessible also after the appliance
has been installed so that it can be pulled out if nece-
ssary.
An efficient earth connection must be ensured.
If the power cable is damaged, it must be replaced by
an authorised Service Centre.
Note:Optional the wires can been connected to the main
PCB of indoor unit by manufacturer according to the
model without terminal block.

Termékspecifikációk

Márka: Beko
Kategória: légkondicionáló
Modell: RSSC18AW-I

Szüksége van segítségre?

Ha segítségre van szüksége Beko RSSC18AW-I, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók légkondicionáló Beko

Beko

Beko BEPB12H Útmutató

12 Január 2025
Beko

Beko EFE6030W Útmutató

31 December 2025
Beko

Beko BK 6300 Útmutató

21 Szeptember 2024
Beko

Beko BRH 246 Útmutató

25 Augusztus 2024
Beko

Beko BPVOW 090 Útmutató

25 Augusztus 2024
Beko

Beko BRH 076 Útmutató

25 Augusztus 2024
Beko

Beko BRH 245 Útmutató

25 Augusztus 2024
Beko

Beko BRH 075 Útmutató

25 Augusztus 2024
Beko

Beko BINR 241 Útmutató

25 Augusztus 2024
Beko

Beko BINR 091 Útmutató

25 Augusztus 2024

Útmutatók légkondicionáló

Legújabb útmutatók légkondicionáló