Please scan this QR code to have
access to our APPs and Products
informaon
APsystems DS3 series
DS3-L and DS3 Microinverters
EMEA region
Installaon Manual
ALTENERGY POWER SYSTEM Inc.
emea.APsystems.com
APsystems
Cypresbaan 7, 2908 LT, Capelle aan den Ijssel
The Netherlands
Tel: +31- - info.emea@APsystems.com10 2582670 EMAIL:
Rue des Monts d’Or, ZAC de Folliouses Sud-Les Echets 01700 Miribel,
France
TEL: +33- - - -40 EMAIL:info.emea@APsystems.com481 65 60
© All Rights Reserved
APsystems DS3 series Installaon/User Manual
1
Table of Contents
1.Important Safety Instrucons ...................................................................................................... 2
1.1 Safety Instrucons ...................................................................................................................................... 2
1.2 Radio Interference Statement .................................................................................................................... 3
1.3 Symbols replace words on the equipment, on a display, or in manuals ................................................... 4
2.APsystems Microinverter System Introducon............................................................................ 5
2.1 Key elements of an APsystems system ....................................................................................................... 5
2.2 The advantages of an APsystems system ................................................................................................... 6
3.APsystems Microinverter DS3 series Introducon ....................................................................... 7
3.1 Characteriscs of the DS3 microinverter .................................................................................................... 7
3.2 Features of the DS3 microinverter.............................................................................................................. 7
4.APsystems Microinverter System Installaon.............................................................................. 8
4.1 Addional accessories supplied by APsystems .......................................................................................... 8
4.2 Other required accessories not supplied by APsystems ............................................................................ 8
4.3 Installaon Procedures ............................................................................................................................... 9
4.3.1 Step 1 - Verify that grid voltage is matching with microinverter rang ......................................... 9
4.3.2 Step 2 Y3 AC Bus Cable distribuon ............................................................................................. 9
4.3.3 Step 3 - Attach the APsystems Microinverters to the Racking ........................................................ 9
4.3.4 Step 4 - Ground the system ............................................................................................................ 10
4.3.5 Step 5 - Connect the APsystems microinverter to AC bus cable ................................................... 10
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable ....................................................11
4.3.7 Step 7 - Connect APsystems Microinverters to the PV Modules .................................................. 12
4.3.8 Step 8 - Complete the APsystems installaon map ...................................................................... 13
4.3.9 Step 9 - Warning Noce ................................................................................................................. 13
5. Microinverter system operang instrucons ............................................................................ 14
6.Troubleshoong ......................................................................................................................... 15
6.1 Status Indicaons and Error Reporng .................................................................................................... 15
6.1.1 Start up LED .................................................................................................................................... 15
6.1.2 Operaon LED ................................................................................................................................ 15
6.1.3 GFDI Error ....................................................................................................................................... 15
6.2 ECU_APP .................................................................................................................................................... 15
6.3 Installer EMA (web portal or EMA Manager APP) ................................................................................... 15
6.4 Trouble Shoong Guide ............................................................................................................................ 15
6.5 APsystems Technical Support ................................................................................................................... 16
6.6 Maintenance ............................................................................................................................................. 16
7.Replace a microinverter............................................................................................................. 17
8.Technical Data ............................................................................................................................ 18
8.1 DS3 series Microinverter Datasheet ......................................................................................................... 19
9. DS3 series - Wiring Diagram ..................................................................................................... 20
9.1 Sample Wiring Diagram - Single Phase ..................................................................................................... 20
10 APsystems Microinverter & Energy Communication Unit Installaon Map ............................. 21
APsystems DS3 series Installaon Manual
2
1.Important Safety Instrucons
This manual contains important instrucons to follow during installaon and maintenance of the APsystems
Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical shock and ensure a safe installaon and
operaon of the APsystems Microinverter, the following symbols appear throughout this document to indicate
dangerous condions and important safety instrucons.
Specicaons are subject to change without noce. Please ensure you are using the most recent update found at
hps://emea.apsystems.com/resources/library/
This indicates informaon that is important for opmized microinverter operaon. Follow these instrucons
closely.
1.1 Safety Instrucons
Only qualified professionals should install and/or replace APsystems Microinverters.
Perform all electrical installaons in accordance with local electrical codes.
Before installing or using the APsystems Microinverter, please read all instrucons and cauonary markings
in the technical documents and on the APsystems Microinverter system and the solar array.
Do NOT disconnect the PV module from the APsystems Microinverter without rst disconnecng the AC
power.
Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Microinverter.
Do NOT attempt to repair the APsystems Microinverter. If the micro is suspected to be faulty, please contact
your local APsystems Technical Support to start troubleshoong and obtain a RMA (Return Merchandise
Authorizaon) number to start the replacement process if needed. Damaging or opening the APsystems
Microinverter will void the warranty.
Cauon!
When connecng a microinverter, it is recommended to rst connect the AC Bus cable to the ground then
connect the AC connector to ensure proper earthing of the micro-inverter, then do the DC connecons. When
disconnecng a microinverter disconnect the AC by opening the branch circuit breaker rst but maintain the
protective earthing conductor in the branch circuit breaker connected to the microinverter, then disconnect
the DC inputs.
Please install AC breakers on the AC side of the inverter.
APsystems DS3 series Installaon Manual
3
1.Important Safety Instrucons
1.2 Radio Interference Statement
CE EMC Compliance The APsystems Microinverter can radiate radio frequency energy. If not installed and used
in accordance with the instrucons, it may cause harmful interference to radio communicaon.
APsystems Microinverter complies with CE EMC regulations, which are designed to provide reasonable protecon
against harmful interference in a residenal installaon.
Nonetheless, if the Microinverter does cause harmful interference to radio or television reception, you are
encouraged to try to correct the interferences by one of more of the following measures:
A) Reorient or relocate the receiving antenna
B) Increase the separaon between the Microinverter and the receiver
C) Connect the Microinverter into an outlet on a circuit different from that to which the receiver is connected
If none of the recommendaons suggested above bring signicant improvement in terms of interferences, please
contact your local APsystems Technical Support.
APsystems DS3 series Installaon Manual
4
1.Important Safety Instrucons
1.3 Symbols replace words on the equipment, on a display, or in manuals
Trademark.
Cauon, risk of electric shock.
Cauon, hot surface.
Symbol for the marking of electrical and electronics devices according to Direcve 2002/96/EC.
Indicates that the device, accessories and the packaging must not be disposed as unsorted
municipal waste and must be collected separately at the end of the usage. Please follow Local
Ordinances or Regulaons for disposal or contact an authorized representave of the manufacturer
for informaon concerning the decommissioning of equipment.
CE mark is aached to the solar inverter to verify that the unit follows the provisions of the European
Low Voltage and EMC Direcves.
Refer to the operang instrucons.
Qualied personnel
Person adequately advised or supervised by an electrically skilled person to enable him or her to
perceive risks and to avoid hazards which electricity can create. For the purpose of the safety
informaon of this manual, a "qualied person" is someone who is familiar with requirements for
safety, electrical system and EMC and is authorized to energize, ground, and tag equipment,
systems, and circuits in accordance with established safety procedures. The inverter and complete
system may only be commissioned and operated by qualied personnel.
APsystems DS3 series Installaon Manual
5
2.APsystems Microinverter System Introducon
2.1 Key elements of an APsystems system
The APsystems Microinverter is used in ulity-interacve grid-ed applicaons, comprised of three key elements:
APsystems Microinverter
APsystems Energy Communicaon Unit (ECU)
APsystems Energy Monitor and Analysis (EMA) web-based monitoring and analysis system
Figure 1
Jun cti on Box
YC600
Distrib ution box
APsystems DS3 series Installaon Manual
6
2.APsystems Microinverter System Introducon
2.2 The advantages of an APsystems system
This integrated system maximizes solar energy harvest, improves safety, increases system reliability, and simplies
solar system design, installaon, maintenance, and management.
APsystems Microinverters maximize PV energy producon
Each PV module has an individual Maximum Peak Power Tracking (MPPT) control, which ensures that the maximum
power is produced to the ulity grid regardless of the performance of the other PV modules in the array. When PV
modules in the array are aected by shade, dust, dierent orientaon, or any situaon in which one module
underperforms compared to the other ones, the APsystems Microinverter ensures top performance from the array
by maximizing the performance of each module individually within the array.
Safety with APsystems Microinverters
In a typical string inverter installaon, PV modules are connected in series. The voltage adds-up to reach high
voltage value (from 600 Vdc up to 1000 Vdc) at the end of the PV string. This extreme high DC voltage brings a
risk of electrical shocks or electrical arcs which could cause re.
When using an APsystems microinverter, PV modules are connected in parallel. Voltage at the back of each PV
module never exceeds PV modules Voc, which is lower than 60 Vdc for most of PV modules used with APsystems
microinverters. This low voltage is considered “safe to touch” by remen department and will avoid risk of
electrical shock, electrical arcs and re hazards.
More reliable than centralized or string inverters
The distributed APsystems Microinverter system ensures that no single point of failure exists across the PV system.
APsystems Microinverters are designed to operate at full power at ambient outdoor temperatures of up to 65 deg
C (or 149 F). The inverter case is designed for outdoor installaon and complies with the IP67 environmental
enclosure rang.
Simple to install
APsystems Microinverters are compable with most of 60 and 72 cell PV modules or 120 and 144 half-cut cells PV
modules. (In order to conrm compability of PV module with APsystems microinverter, feel free to check our
online “E-decider” module compability tool or contact your local APsystems Technical Support).
Installaon requires a minimum number of accessories and microinverters oer a lot of versality to the installer:
microinverters can indeed be installed on different roofs with different orientaon or with modules having
dierent orientaon.
In the same way, end-user can extend their system whenever they want with microinverters.
Smart system performance monitoring and analysis
The APsystems Energy Communicaon Unit (ECU) is installed by simply plugging it into any wall outlet and
providing an Ethernet or Wi-Fi connecon to a broadband router or modem. After installing and setng the ECU
(see ECU Instrucon Manual), the full network of APsystems Microinverters automacally reports to the APsystems
Energy Monitor and Analysis (EMA) web server.
APsystems DS3 series Installaon Manual
7
3.APsystems Microinverter DS3 series Introducon
3.1 Characteriscs of the DS3 microinverter
APsystems 3rd
generaon of dual microinverters are reaching unprecedented power outputs of 730VA or 880VA to
adapt to today’s larger power module. With 2 independent MPPT, encrypted Zigbee signals, the DS3-L and DS3
benet from an entirely new architecture and are fully backwards compable with the QS1 and YC600
microinverters.
The innovave and compact design make the product lighter while maximizing power producon. The components
are encapsulated with silicone to reduce stress on the electronics, facilitate thermal dissipaon, enhance
waterproof properes, and ensure maximum reliability of the system via rigorous tesng methods including
accelerated life tesng. A 24/7 energy access through Apps or web based portal facilitate remote diagnosis and
maintenance.
The DS3 series is interacve with power grids through a feature referred to as RPC (Reacve Power Control) to
beer manage photovoltaic power spikes in the grid. With a performance and an eciency of 97%, a unique
integraon with 20% less components, APsystems DS3-L and DS3 are a game changer to residenal and commercial
PV.
3.2 Features of the DS3 microinverter
Key Product Features:
One microinverter connects to two PV modules
Maximum output power reaching 730VA (DS3-L) or 880VA (DS3)
Two input channels with independent MPPT
Reacve Power Control
Maximum reliability, IP67
Encrypted Zigbee communicaon
Safety protecon relay integrated
Single phase microinverter. Possible to install in a balanced 3-phase system
APsystems DS3 series Installaon Manual
8
4.APsystems Microinverter System Installaon
A PV system using APsystems Microinverters is simple to install. Each Microinverter easily mounts on the PV racking,
directly beneath the PV module(s). Low voltage DC wires connect from the PV module directly to the Microinverter,
eliminang the risk of high DC voltage.
Installaon MUST comply with local regulaons and technical rules.
Special Statement: we advise to install a RCD breaker only if required by the local electrical code.
. Perform all electrical installaons in accordance with local electrical codes.
. Be aware that only qualified professionals should install and/or replace APsystems Microinverters.
. Before installing or using an APsystems Microinverter, please read all instrucons and warnings in the
technical documents and on the APsystems Microinverter system itself as well as on the PV array.
. Be aware that installaon of this equipment includes the risk of electric shock.
. Do not touch any live parts in the system, including the PV array, when the system has been connected
to the electrical grid.
Even if not required by local electrical code, we strongly recommend to install surge protecon devices in
the dedicated AC box.
4.1 Addional accessories supplied by APsystems
AC Y3 Bus cable
AC Y3 Bus Cable End Cap
AC Y3 Bus Cable Y-CONN Cap
AC Y3 Bus Cable Unlock Tool
ECU
AC connectors male/female
4.2 Other required accessories not supplied by APsystems
In addion to your PV array and its associated hardware, you may need the following items:
An AC connecon juncon box
Mounng hardware suitable for module racking
Sockets and wrenches for mounng hardware
APsystems Microinverter System Installaon
APsystems DS3 series Installaon Manual
9
APsystems Microinverter System Installaon
4.3 Installaon Procedures
4.3.1 Step 1 - Verify that grid voltage is matching with microinverter rang
4.3.2 Step 2 Y3 AC Bus Cable distribuon
a. Each connector drop of the AC Bus cable shall be matching the posion of the microinverter.
b. One end of the AC bus cable is used to access the juncon box into the power grid.
c. Wire the conductors of the AC bus: L - BROWN ; N - BLUE PE - YELLOW GREEN.
Wiring color code can be dierent according to the local regulaon. Check all the wires of the installaon
before connecng to the AC bus to be sure they match. Wrong cabling can damage irreparably the
microinverters: such damage is not covered by the warranty.
It is strictly prohibited to hand carry the microinverter by its AC cable.
4.3.3 Step 3 - Aach the APsystems Microinverters to the Racking
a. Mark the locaon of the microinverter on the rack, with respect to the PV module juncon box or any
other obstrucons.
b. Mount one microinverter at each of these locaons using hardware recommended by your module
racking vendor.
Figure 2
Install the microinverters (including DC and AC connectors) under the PV modules to avoid direct exposure
to rain, UV or other harmful weather events. Allow a minimum of 1.5 cm (3/4’’) below and above the casing
of the microinverter to allow proper air ow. The racking must be properly grounded as per local electrical
code.
APsystems DS3 series Installaon Manual
10
APsystems Microinverter System Installaon
4.3.4 Step 4 - Ground the system
Y3 AC Bus cable has an embedded PE wire: this might be suicient to ensure proper grounding of the whole
PV array. However in areas with special grounding requirements, external grounding work may sll be
needed, using the grounding lug supplied with the Microinverter
Figure 3
4.3.5 Step 5 - Connect the APsystems microinverter to AC bus cable
Insert the microinverter AC connector into the Y3 AC trunk cable connector. Make sure to hear the click” as a
proof of robust connecon
Figure 4
Best Pracce: Use the Bus Cable Unlock Tool of AC Bus to disconnect the connectors.
Figure 5
Please check the microinverter technical specicaons (in Appendixes) to conrm the maximum number
of microinverters which can be connected on the same AC branch of the circuit.
Click
grounding lug
APsystems DS3 series Installaon Manual
11
4.APsystems Microinverter System Installaon
AC connector interface as shown below .
Figure 6
Cover any unused connectors with Bus Cable Y-CONN cap to protect the unused connectors. a
Figure 7
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable
a. Strip cable jacket. c. Insert the wires into the cable clamps.
b. Insert the cable end into the seal. d. Rotate the nut with 3.3N·m until the
latching mechanism meets the base.
Figure 8
Nut
Seal
Body

Termékspecifikációk

Márka: APSystems
Kategória: nincs kategorizálva
Modell: DS3-L

Szüksége van segítségre?

Ha segítségre van szüksége APSystems DS3-L, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva APSystems

APSystems

APSystems QT2D Útmutató

1 Október 2024
APSystems

APSystems ECU-C Útmutató

3 Szeptember 2024
APSystems

APSystems QT2 Útmutató

3 Szeptember 2024
APSystems

APSystems DS3D Útmutató

3 Szeptember 2024
APSystems

APSystems DS3 Útmutató

28 Augusztus 2024
APSystems

APSystems DS3-L Útmutató

28 Augusztus 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

MOZA

MOZA SR-P Útmutató

10 Április 2025
CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025