Safety Information
Understand and follow operating instructions carefully.
Use the meter only as specified in this manual; other-
wise, the protection provided by the meter may be
impaired.
WARNING
˙ When using test leads or probes, keep your fingers
behind the finger guards.
˙ Remove test lead from Meter before opening the
battery door or Meter case.
˙ Use the Meter only as specified in this manual or the
protection by the Meter might be impaired.
˙ Always use proper terminals, switch position, and
range for measurements.
˙ Never attempt a voltage measurement with the test
lead inserted into the A input terminal.
˙ Verify the Meter’s operation by measuring a known
voltage. If in doubt, have the Meter serviced.
˙ Do not apply more than the rated voltage, as
marked on Meter, between terminals or between
any terminal and earth ground.
˙ Do not attempt a current measurement when the
open voltage is above the fuse protection rating.
Suspected open circuit voltage can be checked with
voltage function.
˙ Only replace the blown fuse with the proper rating
as specified in this manual.
˙ Use caution with voltages above 30 Vac rms, 42
Vac peak , or 60 Vdc. These voltages pose a shock
hazard.
˙ To avoid false readings that can lead to electric
shock and injury, replace battery as soon as low
battery indicator
<
<
<
<<appears.
˙ Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance,
continuity, diodes, or capacitance.
˙ Do not use Meter around explosive gas or vapor.
˙To reduce the risk of fire or electric shock do not
expose this product to rain or moisture.
Symbols as marked on the meter and
Instruction card
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or reinforced
insulation
<
<
<
<< Battery
Fuse
Earth
<AC measurement
Conforms to EU directives
Do not discard this product or throw away
Measuring AC/DC Voltage And
Frequency
Warning
Warning
Warning
WarningWarning
. . . . . .
. . . . . .
. . . . . .
. . . . . .. . . . . . . . . .
. . . .
. . . .
. . . . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .. . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .. . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
Safety sheet
Safety sheet
Safety sheet
Safety sheetSafety sheet
. . . .
. . . .
. . . .
. . . . . . . .
. . . . .
. . . . .
. . . . .
. . . . . . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .. . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .. . . . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . .
. . . .
. . . .
. . . .. . . .
. . . .
. . . .
. . . .
. . . . . . . .
. . . . .
. . . . .
. . . . .
. . . . .. . . . .
Read First
Testing for Continuity and Diode
APPA
61/62/62T /62R Instruction
Digital Multimeter Card
Resistance
and Capacitance
(Capacitance for 62, 62T, 62R only)
BlackRedBlackRed
Black
Red
Black
Red
Bad Diode
Good Diode
Note – To improve the measurement accuracy of small
value capacitor, record the reading with the test leads
open then substract the residual capacitance of the
Meter and leads from measurement.
CUNKNOWN = CMEASUREMENT
- CRESIDUAL
MIN MAX Record (For 62, 62T, 62R only)
Caution
˙ Disconnect the test leads from the test points before
changing the position of the function rotary switch.
˙ Never connect a source of voltage with the function
rotary switch in Ω/ ;/ A // Hz position.
˙ Do not expose Meter to extremes in temperature or
high humidity.
˙ Never set the meter in A function to measure
the voltage of a power supply circuit in equipment
that could result in damage the meter and the
equipment under test.
Maintenance
Do not attempt to repair this Meter. It contains no
user-serviceable parts. Repair or servicing should
only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and
detergent. Do not use abrasives or solvents.
Disable Auto Power Off
NCV
1. Volt sense switch will be activated on any function
or at OFF status.
2. Test leads are not used for the Volt sense test.
3. Press the Volt sense button. The display goes
black, a tone sounds and the red LED lights up to
verify the instrument is operational. The Volt sense
button must be held down to detect the presence
of voltage without use of the leads.
4. If a voltage of 50V to 600V (50 to 500Hz) is
detected near the top of meter a continuous tone
sounds and the red LED near the top of meter
Illuminates.
Fuse Replacement (For 62, 62T, 62R only)
Refer to the following figure to replace fuse :
Battery Replacement
Refer to the following figure to replace the batteries :
Caution
˙ Replace the batteries as soon as the low batteries
indicator "<" appears, to avoid false reading.
˙ Batteries 1.5V x 2
Caution
˙ Use only a fuse with the amperage, interrupt,
voltage, and speed rating specified.
˙ Fuse rating : 10A, 500V
Non-Contact Voltage (Volt sense)
Auto Power Off (Battery Saver)
Manual Ranging and Auto Ranging
10 min
Specifications
General Specifications
Display : 2000 counts.
Polarity Indication : Automatic, positive implied,
negative indicated.
Overrange Indication : “OL” or “-OL”.
Batteries
Life : Alkaline 250 hours
Low Batteries Indication : “<” is displayed when
the batteries voltage drops below operating voltage.
Auto Power Off : Approx 10 minutes.
Operating Ambient : Non-condensing ≦
≦
≦
≦≦50F,
51.8F ~ 86F (≦
≦
≦
≦≦80% R.H) 87.8F ~ 104F (≦
≦
≦
≦≦75% R.H),
105.8F ~ 122F (≦
≦
≦
≦≦45% R.H)
Storage Temperature : -4F to 140F , 0 to 80%
R.H. when battery removed from Meter.
Temperature Coefficient :
0.15 x (Spec.Accy) / F ,< 64.4F or > 82.4F.
Measure : Samples 2 times per second nominal.
Altitude : 6561.7 ft (2000m)
Safety : Complies with EN61010-1, UL61010-1,
IEC 61010-1,
V/Ω : CAT.III. 600V, CAT.II. 1000V.
A : CAT.III. 500V (for 62/62T/62R only)
Pollution degree : 2
Power Requirements :
1.5V x 2 IEC LR03, AM4 or AAA size
Dimensions (W x H x D) : 74mm x 156mm x 44mm
Weight : (320g) including battery.
Accessories : Battery (installed), Test leads and
user manual.
Measuring DC / AC Current
(For 62, 62T, 62R only)
Disconnect
Temperature °C ,°F
R
DCV
Display Hold
Termékspecifikációk
Márka: | Appa |
Kategória: | multiméter |
Modell: | 62 |
Szüksége van segítségre?
Ha segítségre van szüksége Appa 62, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók multiméter Appa
Útmutatók multiméter
- multiméter PeakTech
- multiméter Milwaukee
- multiméter Maxwell
- multiméter Emos
- multiméter Voltcraft
- multiméter Vimar
- multiméter Digitus
- multiméter GW Instek
- multiméter Owon
- multiméter Aim TTi
- multiméter Gossen Metrawatt
- multiméter Amiko
- multiméter Klein Tools
- multiméter Chauvin Arnoux
- multiméter Workzone
- multiméter Beha-Amprobe
- multiméter Qian
- multiméter Joy-It
- multiméter Extech
- multiméter Testo
- multiméter Powerfix
- multiméter Biltema
- multiméter REV
- multiméter BENNING
- multiméter Alecto
- multiméter Yato
- multiméter Velleman
- multiméter TFA
- multiméter Monacor
- multiméter Elro
- multiméter Fluke
- multiméter Uni-T
- multiméter Metrix
- multiméter Abus
- multiméter Megger
- multiméter Testboy
- multiméter Sonel
- multiméter Wiha
- multiméter Schneider
- multiméter Kyoritsu
- multiméter Brandson
- multiméter Silverline
- multiméter Rigol
- multiméter Multimetrix
- multiméter Weidmüller
- multiméter Laserliner
- multiméter Amprobe
- multiméter Ferm
- multiméter Tacklife
- multiméter Somogyi
- multiméter Profile
- multiméter Steren
- multiméter Flir
- multiméter Hager
- multiméter Clas Ohlson
- multiméter Etekcity
- multiméter Greenlee
- multiméter Högert
- multiméter Bruder Mannesmann
- multiméter Keithley
- multiméter Metrel
- multiméter Digi-tool
- multiméter Skandia
- multiméter Elma
- multiméter Hubinont
- multiméter Kewtech
- multiméter Strex
- multiméter Mastech
- multiméter MBS
- multiméter MGL Avionics
- multiméter PCE Instruments
- multiméter Micronta
- multiméter CEM
- multiméter Horex
- multiméter Cosinus
- multiméter Kurth Electronic
- multiméter Testec
- multiméter IWH
- multiméter Weltron
- multiméter Sanwa
- multiméter Rohde & Schwarz
- multiméter EEVBlog
- multiméter Kingcraft
- multiméter HT Instruments
- multiméter Caltek
- multiméter Elworks
- multiméter Bearware
- multiméter Noyafa
Legújabb útmutatók multiméter
3 Január 2025
1 Január 2025
29 December 2024
29 December 2024
29 December 2024
29 December 2024
23 December 2024
22 December 2024
19 December 2024
17 December 2024