990-0374A revision 2 11/01
This a dendum does not apply to Ba k-UPS P o 1000/1400 and Smart-UPS V/S 1000/1400d c r
I.Installation
Follow the installation illustration on the accompanying sheet.
Note: Small sparks at the battery connectors are normal during connection.
II. Post-Installation
Once installed,
allow the unit to charge for five hours. If the unit is an XL model, allow it to charge for
24 hours.
Note: The Smart-UPS will charge whether it is on or off, and will charge whether there is a load
present or not. In situations where the power quality is poor, it is recommended that the unit be
shutdown during this charging period. A Smart-UPS that is powered on may switch to battery
operation which would prolong the time needed to fully recharge the battery.
III. Clearing the Replace Battery LED
A. In order for the replace battery LED validto be cleared, it is necessary to run a self test. For a self test
to be considered valid, the following conditions must be satisfied:
■battery capacity must be greater than 75%(minimum of four battery bar graph LEDs illuminated)
or
■Smart-UPS must have been charging for at least 8 hours from the last low battery condition. (Low
battery condition refers to a state when the Smart-UPS battery has fully discharged).
B. Ways to initiate a self test
A self test can be initiated in any one of five ways:
■Start up of the UPS
■Smart-UPS front panel test button
■Powerchute PLUS software
■SmartSlot Accessory
■Automatic timer- every two weeks from turn on (see APC owners manuals for details)
IV. Verifying Operation
A. What happens during a self test?
When a self test is initiated, the unit supports the load while operating on battery for approximately
8-10 seconds. During this period, the Smart-UPS determines the health of the battery.
B. When should the self test be performed?
After the unit has charged for five hours, a self test can be performed.
Replacement Battery Cartridge(RBC) Addendum
RBC5, RBC6, RBC7, RBC8, RBC9, RBC11, RBC12, RBC22, RBC23, RBC24, RBC25,
RBC27, RBC28, RBC5I, RBC6I, RBC7I, RBC8I, RBC9I, RBC11I, RBC12I, RBC22I,
RBC23I, RBC24I, RBC25I, RBC5J, RBC6J, RBC7J, RBC8J, RBC11J, RBC12J,

C. What happens when the replace battery LED does not clear?
If the self test fails:
■If the battery capacity is greater than 75%, turn the unit off and restart it. When you turn a Smart-
UPS on, it will initiate a self-test. After the test completes, the LED should clear.
■If the unit fails the self-test again, contact APC Customer Support (email: support.apcc.com or
phone: 800-800-4APC).
V. Increasing ‘Runtime Remaining’ of the Smart-UPS as viewed through Powerchute
PLUS or SmartSlot Accessory and prevent premature Low Battery Signal
Discharging and recharging a Smart-UPS resets the microprocessor to properly read battery voltage.
An accurate measurement is important when calculating the runtime remaining value appearing in
Powerchute PLUS or SmartSlot Accessory.
A. Initiating a runtime calibration
The runtime calibration option is accessible using Powerchute PLUS software or an APC SmartSlot
Accessory. Once the battery capacity reaches 100%, select this option. The unit will run on battery until
battery capacity is 25%. At that point, the unit will return to utility power and begin recharging itself. If
the runtime as seen through Powerchute PLUS or SmartSlot Accessory does not increase, then follow
the instructions in the next section.
Note: APC recommends that a runtime calibration be initiated once every six months at a maximum.
B. Disconnect from utility
By disconnecting the UPS from utility, a premature low battery signal can be prevented. It is recom-
mended that the power to the circuit be turned off at the distribution panel. Unplugging the Smart-UPS
from the outlet is not recommended.
Note: The Smart-UPS will run on battery until it discharges completely, turning off the load. It is not
necessary to discharge completely. Power can be restored to the unit once it reaches low battery
condition(see owner’s manual for details on how to identify low battery condition).
If experiencing low runtime or premature low battery signal issues, contact APC Customer Support
(email: support.apcc.com or phone: 800-800-4APC).
Termékspecifikációk
Márka: | APC |
Kategória: | Accu |
Modell: | RBC18 |
Szüksége van segítségre?
Ha segítségre van szüksége APC RBC18, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Accu APC

14 December 2024

14 December 2024

14 December 2024

14 December 2024

13 Augusztus 2024

10 Augusztus 2024

7 Augusztus 2024

5 Augusztus 2024

4 Augusztus 2024

27 Július 2024
Útmutatók Accu
- Accu Sony
- Accu Nedis
- Accu Milwaukee
- Accu LG
- Accu Husqvarna
- Accu Parkside
- Accu Worx
- Accu Bosch
- Accu Panasonic
- Accu Canon
- Accu JVC
- Accu Stihl
- Accu Ozito
- Accu HQ
- Accu Fuxtec
- Accu Digitus
- Accu Crestron
- Accu Cramer
- Accu Tripp Lite
- Accu Hikvision
- Accu Epson
- Accu Huawei
- Accu EGO
- Accu Hama
- Accu Sennheiser
- Accu Nikon
- Accu Toolcraft
- Accu TOA
- Accu Cobra
- Accu Scosche
- Accu Hilti
- Accu Black & Decker
- Accu Gardena
- Accu DJI
- Accu Aluratek
- Accu PowerPlus
- Accu Sungrow
- Accu Xtorm
- Accu Speed-Link
- Accu Growatt
- Accu Biltema
- Accu CyberPower
- Accu RYOBI
- Accu Stiga
- Accu SolarEdge
- Accu HiKOKI
- Accu Deltaco
- Accu McCulloch
- Accu Greenworks
- Accu Monacor
- Accu Conrad
- Accu Fluke
- Accu Thomann
- Accu Zipper
- Accu Abus
- Accu Trust
- Accu DeWalt
- Accu Stinger
- Accu Watson
- Accu Arctic Cooling
- Accu Impact
- Accu Leica
- Accu Vonroc
- Accu Nitecore
- Accu Varta
- Accu Fein
- Accu PowerBass
- Accu Arris
- Accu Victron Energy
- Accu Duracell
- Accu Neewer
- Accu Anton/Bauer
- Accu Bolt
- Accu Cocraft
- Accu Belkin
- Accu Ansmann
- Accu A-solar
- Accu Vetus
- Accu Skil
- Accu Targus
- Accu Hähnel
- Accu Berg
- Accu Energenie
- Accu Kensington
- Accu Techly
- Accu Petzl
- Accu Sandberg
- Accu Valcom
- Accu Cortina
- Accu Carat
- Accu Kress
- Accu For_Q
- Accu Genaray
- Accu Ranex
- Accu SKROSS
- Accu Ergotron
- Accu Energizer
- Accu Team Orion
- Accu Venom
- Accu BlackVue
- Accu Inovonics
- Accu Anova
- Accu Red Power
- Accu Ultron
- Accu Enphase
- Accu E-flite
- Accu Whistler
- Accu PNY
- Accu PowerDrive
- Accu LSI
- Accu Variotek
- Accu Lenmar
- Accu Renata
- Accu Fxlion
- Accu SOUNDBOKS
- Accu FeinTech
- Accu Verico
- Accu Levolta
- Accu HART
- Accu APSystems
- Accu TCW Technologies
- Accu Enerdrive
- Accu Ventev
- Accu PAG
Legújabb útmutatók Accu

3 Április 2025

10 Január 2025

4 Január 2025

3 Január 2025

1 Január 2025

31 December 2025

31 December 2025

31 December 2025

30 December 2025

30 December 2025