Használati útmutató Accucold ARG15ML

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Accucold ARG15ML (44 oldal) a hűtőszekrény kategóriában. Ezt az útmutatót 5 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/44
Model:
Serial No.:
Write Model and Serial Numbers
here:
MEDICAL REFRIGERATORS
Models
ARS1PV
ARS1PV456
ARS1ML
ARG1PV
ARG1PV456
ARG1ML
ARS3PV
ARS3PV456
ARS3ML
ARG3PV
ARG3PV456
ARG3ML
ARS6PV
ARS6PV456
ARS6ML
ARG6PV
ARG6PV456
ARG6ML
ARS8PV
ARS8PV456
ARS8ML
ARG8PV
ARG8PV456
ARG8ML
ARS12PV
ARS12PV456
ARS12ML
ARG12PV
ARG12PV456
ARG12ML
ARS15PV
ARS15PV456
ARS15ML
ARG15PV
ARG15PV456
ARG15ML
ARS18PV
ARS18PV456
ARS18ML
MLRS18MC
R18AS
HCRG19
ARG18PV
ARG18PV456
ARG18ML
MLRG18MC
R18AG
HCRG18
ARG31PVBIADA,
ARG31PVBIADA456
ARG31MLBIADA
ARS32PVBIADA
ARS32PVBIADA456
ARS32MLBIADA
ARG61PVBIADA
ARG61PVBIADA456
ARG61MLBIADA
ARS62PVBIADA
ARS62PVBIADA456
ARS62MLBIADA
User Manual
BEFORE USE, PLEASE READ FOLLOW ALL SAFETY RULES OPERATING AND AND
INSTRUCTIONS
Accucold Division of Felix Storch, Inc.
An ISO 9001:2015 registered company
770 Garrison Avenue
Bronx, NY 10474
www.accucold.com
2
EQUIPMENT SAFETY
Your safety and safety others are very important. the of
We have provided many important safety messages this manual and your unit. Always read and in on
obey all safety messages.
This the Safety Alert Symbol. The symbol alerts you to potential hazards is that
can kill injure you and others. All safety messages will follow the Safety or
Alert Symbol and either the words "DANGER" "WARNING". or
DANGER means that failure to heed this safety
statement result severe personal injury may in or
death.
WARNING means that failure heed this safety to
statement may result in extensive product
damage, serious personal injury, death. or
All safety messages will alert you about the potential hazard, tell you how reduce the chance of injury, to
and let you know what can happen if the instructions are followed. not
EQUIPMENT SAFETY
Before the equipment is used, it must be properly positioned and installed as
described in this manual, so read the manual carefully. reduce the risk re, To of
electrical shock or injury when using this equipment, follow basic precautions,
including the following:
Plug into a grounded 3-prong outlet, do not remove grounding prong, do not use an adapter, and do
not use extension cord. an
Replace all panels before operating.
It recommended that a separate circuit serving only your unit provided. Use receptacles that is be
cannot turned by a switch pull chain. be off or
Never clean the equipment parts with ammable uids. These fumes can create a re hazard or
explosion. And store or use gasoline ammable vapors liquids the vicinity do not or other and in of
this any other pieces of equipment. The fumes can create a re hazard explosion. or or
Before proceeding with cleaning and maintenance operations, make sure the power line the unit of is
disconnected.
Do not connect or disconnect electric plug when your hands are wet. the
Unplug the unit disconnect power before cleaning or servicing. Failure or to do so can result in
electrical shock death. or
Do attempt not to repair or replace any part your unit unless specifically recommended this of it is in
manual. All other servicing should referred to a qualied technician. be
These units are CFC- and HFC-free and contains a small quantity of Isobutane (R600a), and the
ARS18PV and ARG18PV are CFC- and HFC-free and contain a small quantity of propane (R290).
Both are environmentally friendly, but ammable. They do not damage the ozone layer, nor do they
increase the greenhouse eect. Care must be taken during transportation and setting up of a unit that
no parts of the cooling system are damaged. Leaking coolant can ignite and damage the eyes. may
In the event of any damage:
-
Avoid open ames and anything that creates a spark,
-
Disconnect from the electrical power line,
-
Air the room in which the unit isolated several minutes, for and
3
-
Contact the Service Department for advice.
The more coolant there is in a unit, the larger the room it should be installed in. In the event of a
leakage, the unit a small room, there the danger combustible gases building For every if is in is of up.
ounce of coolant, at least 325 cubic feet of room space is required. The amount of coolant in the unit
is stated on the data plate inside the unit. It is hazardous for anyone other than an Authorized Service
Person carry servicing repairs to this piece equipment. to out or of
Take serious care when handling, moving, and using the unit to avoid either damaging the refrigerant
tubing or increasing risk of a leak. the
Replacing component parts and servicing shall done factory authorized service personnel be by so as
to to minimize the risk possible ignition of due incorrect parts or improper service.
FOLLOW WARNING CALLOUTS BELOW ONLY WHEN APPLICABLE YOUR MODEL TO
Use two or more people move and install . Failure can result in back injury. to unit to do so or other
To ensure proper ventilation for your , the front of the unit must be completely unobstructed. unit
Choose a well-ventilated area with temperatures above 60°F (16°C) and below 90°F (32°C). [For
optimal performance, install the unit where the ambient temperature is between72º and 78ºF (23º-
26ºC).] This unit must installed in area protected from the elements, such wind, rain, water be an as
spray or drips.
The unit should not located next to ovens, grills other sources of high heat. be or
The unit must installed with all electrical, water and drain connections accordance with state be in and
local codes. A standard electrical supply (115 V AC only, 60 Hz), properly grounded in accordance
with the National Electrical Code and local codes and ordinances, required. is
Do kink or pinch power supply cord the unit. not the of
The size of the fuse (or circuit breaker) should be 15 amperes.
It important that the equipment leveled order work properly. You need make several is be in to may to
adjustments level it. to
All installations must accordance with local plumbing code requirements. be in
Make certain that the pipes are pinched, kinked damaged during installation. not or
Check leaks after connection. for
Never allow children operate, play with crawl inside unit. to or the
Do use solvent-based cleaning agents or abrasives the interior. These cleaners damage not on may
or discolor interior. the
Use this equipment only for its intended purpose described this . as in Instruction Manual
Keepngers the areas. Clearances between the door cabinet are necessarily out of pinch point” and
small. careful closing the door when children are in area. Be the
Risk child entrapment! of
Child entrapment suocation are not problems the past. Junked abandoned appliances are and of or
still dangerous, even if will sit the garage a they “just in few days”.
Before discarding your old refrigerator:
Take the doors off
Leave the shelves place children may easily climb inside. in so that not
-SAVE THESE INSTRUCTIONS-

Termékspecifikációk

Márka: Accucold
Kategória: hűtőszekrény
Modell: ARG15ML

Szüksége van segítségre?

Ha segítségre van szüksége Accucold ARG15ML, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók hűtőszekrény Accucold

Útmutatók hűtőszekrény

Legújabb útmutatók hűtőszekrény