Használati útmutató Velleman DVM860BL

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Velleman DVM860BL (54 oldal) a multiméter kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/54
DVM860BL VELLEMAN - 1 -
DVM860BL – DIGITAL MULTIMETER
1. Introduction
At the end of its life cycle, dispose of this product in accordance with local and national disposal
regulations. Read the manual thoroughly before bringing this device into service
Thank you for buying the ! Use this device to measure and test: AC & DC voltage & current (also with DVM860BL
optional clamp ), resistance, temperature, batteries, diodes, continuity and transistors. AC97
2. Safety
The is developed in accordance with IEC1010-1 concerning safety requirements for electrical measuring DVM860BL
instruments with an overvoltage category (CAT III) 600V and pollution 2. Respect these safety prescriptions:
Protect yourself against electroshocks.
Do not use this device for any other application than those described in this manual.
Make sure the device was not damaged in transit.
Make sure the insulation of the test leads is not damaged and/or the wire itself is not exposed.
Full compliance with safety standards can only be guaranteed if the device is used with the supplied test leads. If
necessary, they should be replaced with identical leads or leads with identical electric ratings. All test leads should
be in good working order.
Select the right input jack, function and range before use.
Never exceed the specified limit values for the various measurement ranges.
Do not touch unused terminals when the meter is connected to a circuit.
Place the range selector in the highest position if the value to be measured is unknown beforehand.
Do not measure voltages > 600V above earth ground.
Exercise extreme caution when working with voltages in excess of 60Vdc or 30Vrms AC. Keep your fingers behind
the probe barriers while using the device.
Do not connect the leads to a voltage source while the function switch is in one of the following modes: current,
resistance, temperature, battery, diode, transistor or continuity.
Disconnect all test leads from the circuit to be tested prior to selecting a different function or range.
Do not use the meter in dusty environments or in the presence of flammable gases and steam.
Have the device checked by a qualified technician in case of malfunction.
Never use the meter if the back panel is not in place and firmly fixed.
Do not use or store the device in areas exposed to direct sunlight, high temperatures or high humidity.
3. Device Description
a. Front Panel
1. LCD display : allows readout of the measured values
2. ON/OFF button : used to activate / deactivate the device
3. RANGE button : used to select auto or manual range
4. FUNC. button : select AC or DC measurement, select °C or °F
5. Selector : used to select the desired function and range
6. 10A jack : input terminal for max. 10A current
7. INPUT jack : input terminal (exception: 10A)
8. COM jack
9. Backlight button ( ) : to illuminates the LCD for a few seconds
10. DATA HOLD button : Displayed data are held
11. MAX HOLD button : Max. measured value is held
DVM860BL VELLEMAN - 2 -
b. Display Symbols
Safety issue,
consult the manual
AC
Alternating current
DC
Direct current
Double insulation
(Protection class II)
AC or DC
Fuse
Earth ground
/
Battery / Battery low
conforms to EU directives
Diode
Continuity buzzer
Measurement with (optional)
clamp
MAX.H
Max. value is being held
DATA-H
Displayed data are held
AUTO
Automatic range selection
CATIII
Overvoltage category III,
pollution degree 2 (IEC1010-1)
4. Maintenance
Do not remove the back cover while a voltage is being applied. Only a qualified technician should handle repairs.
Always disconnect the test leads from all current sources before opening the meter.
Replace the batteries when the symbol is displayed.
Replace blown fuses with an identical one or a fuse with identical voltage and current ratings: F 200mA/250V
(quick-acting).
Use a damp cloth and a mild detergent to clean the device. Never apply abrasives or solvents to the meter
Place the power switch in the OFF position when the device is not being used
Remove the batteries to keep them from leaking if the device is to be stored for a long time.
5. Specifications
Max. accuracy is achieved during a one-year period after calibration. Ideal circumstances require a temperature of 18
to 28°C (64 to 82°F) and a max. relative humidity of 75%.
5.1 General Specifications
Sampling Time ±0.4sec.
Display LCD 16mm
Max. Display 1999 points (3 ½ digits)
Polarity Indication "-" indicates negative polarity
Overrange Indication "OL"
Displayed Measuring Unit Unit of electrical capacity
Battery-Low Indication " "-symbol is displayed
Maximum Altitude 7000ft (2000m)
Max. voltage between terminals and earth 600V DC or AC
Fuse Protection F 200mA/250V (quick-acting)
Automatic Power Off 15 minutes
Power Supply 3 x 1.5V AAA-battery
Operating Temperature C to +40°C (+32 to +104°F)
Storage Temperature -10°C to +50°C (+10 to +122°F)
Dimensions 158 x 74 x 32mm
Weight ±250g (batteries included)
DVM860BL VELLEMAN - 3 -
5.2 Electrical Specifications
5.2.1. DC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
600V 1V
±0.7% of rdg + 2 digits
Input Impedance : 10M
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or V rms AC for the ranges 2V to 600V
Max. Input Voltage : 600V DC
5.2.2. AC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
±0.8% of rdg + 3 digits
600V 1V ±1.0% of rdg + 3 digits
Input Impedance : 10M
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or AC rms for the ranges 2V to 600V
Frequency Range : 40 to 400Hz
Response : average response, calibration in rms of a sine wave.
Max. Input Voltage : 600V rms AC
5.2.3. DC Current
Range Resolution Accuracy
200µ A 0.1µ A
2000µ A A
20.00mA 0.01mA
200.00mA 0.1mA
±1.2% of rdg + 3 digits
2.000A 0.001A
10.00A 0.01A
±2.0% of rdg + 10 digits
Overload Protection : F 200mA/250V fuse (quick-acting) for the µA, mA ranges. The 2A and 10A range are unfused.
Max. Input Current : INPUT jack: 200mA, 10A jack: 10A.
Voltage Drop : 200µV, 20mA, 2A: 20mV, 2000µA, 200mA, 10A-range: 200mV.
5.2.4. AC Current
Range Resolution Accuracy
200µ A 0.1µ A
2000µ A A
20.00mA 0.01mA
200.00mA 0.1mA
±1.5% of rdg + 5 digits
2.000A 0.001A
10.00A 0.01A
±3.0% of rdg + 10 digits

Termékspecifikációk

Márka: Velleman
Kategória: multiméter
Modell: DVM860BL

Szüksége van segítségre?

Ha segítségre van szüksége Velleman DVM860BL, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók multiméter Velleman

Velleman

Velleman DVM840 Útmutató

5 Október 2024
Velleman

Velleman DVM1500 Útmutató

5 Október 2024
Velleman

Velleman DVM852 Útmutató

5 Október 2024
Velleman

Velleman DVM831 Útmutató

22 Szeptember 2024
Velleman

Velleman DVM870 Útmutató

2 Szeptember 2024
Velleman

Velleman VTTEST23 Útmutató

25 Augusztus 2024
Velleman

Velleman EMDIN03 Útmutató

20 Augusztus 2024
Velleman

Velleman EMDIN02 Útmutató

13 Augusztus 2024
Velleman

Velleman DVM821 Útmutató

6 Augusztus 2024

Útmutatók multiméter

Legújabb útmutatók multiméter

Uni-T

Uni-T UT33A Útmutató

3 Április 2025
Uni-T

Uni-T UT151A Útmutató

3 Április 2025
Uni-T

Uni-T UT171B Útmutató

3 Április 2025
Uni-T

Uni-T UT139B Útmutató

3 Április 2025
Uni-T

Uni-T UT139A Útmutató

3 Április 2025
Uni-T

Uni-T UT219E Útmutató

3 Április 2025
Uni-T

Uni-T UT89XD Útmutató

3 Április 2025
Proline

Proline 15186 Útmutató

26 Március 2025