Installation and
Quick Start Guide
SNMP/Web Management Accessory
Model: SRCOOLNET2LX
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
Read this guide carefully before installation. A separate downloadable User’s
Guide can be found by going to www.tripplite.com/support and typing
SRCOOLNET2LX in the search field. Refer to the User's Guide for additional
information about configuration and operation.
Installation 2
Features 10
Tech Support 12
Warranty 12
Product Registration and 13
Regulatory Compliance
Español 14
Français 27
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
18-06-379-93387E.indb 1 7/26/2018 4:19:58 PM
2
The SRCOOLNET2LX allows a user to communicate with and control Tripp Lite’s
SRCOOL2KWM, SRCOOL7KRM, SRCOOL18K, SRCOOL24K (pre-installed in unit) spot
coolers, and compatible SRCOOL33K row-based cooler as manageable devices on a
network accessible via Web browser, network management station, telnet, SSH or
command line.
1 - Preparation
1-1 Confirm Package Contents: In addition to this manual, your package should
include the following:
Micro-USB cable for remote temperature sensing and configuration
(part number: 73176E), 12 ft.
EnviroSense2 E2MT Sensor Module
E2MT User Manual
1-2 Locate MAC Address: The 12-digit MAC address (000667xxxxxx) is located on
the SRCOOLNET2LX.
Installation
2 Installation
2-1 Insert the SRCOOLNET2LX into the front SNMP accessory slot on the
SRCOOL2KWM/7KWM/18K/24K spot coolers or compatible SRCOOL33K
row-based cooler (Figure 1 in section 4-2).
2-2 Connect SRCOOLNET2LX to Network: Connect a standard Ethernet patch
cable to the RJ45 Ethernet port on the SRCOOLNET2LX.
Note: This port does not support PoE (Power over Ethernet) applications.
2-3 Determine Network Installation Method: If your network's DHCP server will
assign a dynamic IP address to the SRCOOLNET2LX automatically, proceed to
3 - Dynamic IP Address Assignment. If you will assign a static IP address to
the SRCOOLNET2LX manually, proceed to . If 4 - Static IP Address Assignment
you are uncertain which method to use, contact your network administrator for
assistance before continuing the installation process.
18-06-379-93387E.indb 2 7/26/2018 4:19:58 PM
3
Installation
3 - Dynamic IP Address Assignment
3-1 Connect SRCOOLNET2LX to Network: By default, the SRCOOLNET2LX will
attempt to obtain an IP address via DHCP. This may take as long as several
minutes, depending on your network environment.
3-2 Discover IP Address: To identify the IP address assigned to the
SRCOOLNET2LX, contact your network administrator and provide the MAC
address of the SRCOOLNET2LX. You can also determine the IP address locally at
the card. If you do not already have the serial over USB driver installed on your
PC, you can download it from www.tripplite.com/support by typing
SRCOOLNET2LX in the search field. Select the driver named “TL-cdc”. To install,
follow the instructions provided with the driver.
Once the driver is installed and the COM port has been assigned, start a
terminal emulation program, such as Tera Term Pro. Configure it to use the
assigned COM port and use the following serial port settings: 115.2Kbps, 8,
NONE, 1. Connect the USB cable to the PC and the Micro-USB end to the
Micro-USB port on the SRCOOLNET2LX. When the login prompt appears, login as
localadmin / localadmin. When the Menu appears, navigate to "3- Network
Configuration", then to "1- IP Configuration". The assigned IP address will be
displayed. After you have determined the IP address, proceed to section 5 - Test
and Configure.
Notes:
Usernames and passwords are case sensitive.
You may wish to request a long-term lease period for the IP address, depending on your
application.
PowerAlert® Device Manager and the WEBCARDLX support both IPv4 and IPv6. The card
is set up by default to receive a DHCP address for IPv4, IPv6 or both. Receiving both
addresses allows connection to the card via either the IPv4 or IPv6 address.
18-06-379-93387E.indb 3 7/26/2018 4:19:58 PM
4
Installation
4 - Static IP Address Assignment/Terminal Menu
Configuration Settings
4-1 Determine IP Information: The SRCOOLNET2LX can support a single static IPv4
address (requires setting the IP address, subnet mask and gateway) and/or a
single static IPv6 address. In addition, the SRCOOLNET2LX can support a single
static IPv4 or an IPv6 DNS address that is required to be entered.
4-2 Configure Terminal Emulation Program: If you have not already done so,
download the serial over USB driver (TL-cdc) from the Tripp Lite website. The
driver can be found by going to www.tripplite.com/support and typing
SRCOOLNET2LX in the search field. To install the driver, follow the instructions
provided. Once the driver is installed and a COM port has been assigned, set
your terminal emulation program to use the COM port that corresponds to the
USB port.
SRCOOL7KRM
SRCOOLNET2LX
SRCOOL18K / SRCOOL24KSRCOOL2KWM SRCOOL33K
COMPUTER
WITH USB PORT
4-3 Connect SRCOOLNET2LX to Computer: Using the provided cable, connect your
PC to the Micro-USB port on the SRCOOLNET2LX.
Figure 1
18-06-379-93387E.indb 4 7/26/2018 4:19:59 PM
5
Installation
4-4 The card will display a Linux-style login after boot up. Login as localadmin /
localadmin to access the standard menu.
Note: Usernames and passwords are case sensitive.
4-5 From the Main Menu:
a. Select Option 3: Network Configuration
b. Select Option 1: IP Configuration
c. Select Option 3: IPv4 setting on Option 4: IPv6 settings
d. Select Option 1: Method
e. Select Option 2: Static
Assign the address, subnet mask, gateway, etc. Save your settings by selecting
"A" (apply). Choose yto restart PowerAlert now. Close your terminal session.
4-6 Remove Configuration Cable: Remove the configuration cable that connects
the SRCOOLNET2LX to the computer.
18-06-379-93387E.indb 5 7/26/2018 4:19:59 PM
6
Installation
5 - Test and Configure
5-1 Test Network Connection: After an IP address has been assigned to the card,
try to access it with a Web browser. Open Firefox or Chrome on a computer
connected to the network and enter http:// or https:// followed by the IP address.
The login screen for the PowerAlert Device Manager will display. The default
username is and the password is . After you enter the localadmin localadmin
username and password, the PowerAlert Status page will appear in the browser
window. For more information about configuration and operation of the managed
device, refer to the User's Guide located in the support section of the
SRCOOLNET2LX product web page.
Note: Usernames and passwords are case sensitive.
18-06-379-93387E.indb 6 7/26/2018 4:19:59 PM
7
Installation
6 - Using E2MT as Remote Set Temperature Sensor
SRCOOLNET2LX supports the use of one E2MT environmental sensor (included) to
control the temperature, rather than the AC units default internal temperature sensor
in the return airstream. The E2MT sensor can be located in the area you wish to
control to the specific set point.
6-1 Configuring SRCOOLNET2LX for Remote Set-Point Usage
To use the Remote Temperature Set-Point feature, ensure the E2MT device is
installed in the desired location for monitoring and also connected to the
SRCOOLNET2LX A.
SRCOOLNET2LX
E2MT Module
SRCOOLNET2LX
E2MT
Module
A
18-06-379-93387E.indb 7 7/26/2018 4:20:00 PM
8
Installation
From the PowerAlert Device Manager Interface, turn ON the cooling unit by
selecting the Control menu. Under the Control menu, check the "Turn On Device"
option and click the activation button to the right. Next, navigate to the
Configuration menu> Device Settings to ensure the E2MT sensor is selected.
Under the Function: Device Thresholds drop-down menu in the box labeled
“Value”, type in the temperature set-point you wish the SRCOOLNET2LX to target
A and press activation button to the right B. The set point control on the device
display panel will be overridden.
A
B
18-06-379-93387E.indb 8 7/26/2018 4:20:00 PM
9
Installation
The cooling unit will now begin cooling when the temperature reading at E2MT
equals or exceeds the set point value you entered. When the temperature falls
below this set-point, the unit will stop cooling. If the Always On” checkbox is
checked, the fans will remain running when the unit stops cooling. If the Always
On” checkbox is unchecked, the fans will shut off and the unit will shut down. Once
the temperature reaches the set point again, the unit will restart and begin cooling
until the temperature reported by E2MT returns below the set point.
Note: This cycle will continue indefinitely until you select “Shutdown Cooler” from the
SRCOOLNET2LX user interface or turn the cooling unit off via the device display panel.
6-2 Important Considerations When Using Remote Temperature Setpoint
Mode
It is important to keep the following considerations in mind when using the
Remote Temperature Set-Point feature of SRCOOLNET2LX:
1 The temperature being used for controlling the attached cooling device is the
E2MT sensor, NOT the return air temperature. The return air temperature
may be higher or lower than the temperature E2MT is reporting.
2 The set point displayed on the attached cooling units display panel should
be ignored when the SRCOOLNET2LX is set to Remote Temperature Set-
Point mode in the PowerAlert Device Manager.* The set point displayed on
the device display panel will be the minimum (when cooling) or maximum
(when not cooling) set point permissible by the cooling unit.*
*The SRCOOL2KWM and compatible SRCOOL33K will display the correct set point on
the cooling unit's display.
Note: When the Remote Set-Point Temperature feature is enabled, the unit will show
as "EXTERNAL" on the SRCOOL33K's LCD display. If there is no setting of external
temperature set-point within 60 seconds, the unit will measure the value internally and
the icon "EXTERNAL" will be off.
3 If the power button on the cooling unit display panel is pressed while in
Remote Temperature Set-Point mode, the mode will be canceled.
18-06-379-93387E.indb 9 7/26/2018 4:20:00 PM
10
Features
A Ethernet Port: RJ45 jack connects the SRCOOLNET2LX to the network using a
standard Ethernet patch cable. The Link LED A1 and Status LED A2 indicate the
operating conditions. See the LED Function Table for a description of LED
behavior.
B Micro-USB Port: Use this port to directly connect with a computer running a
terminal emulation program. A cable (part number: 73176E) is included with the
SRCOOLNET2LX. If you need to order a replacement cable, contact Tripp Lite
Customer Support at 773.869.1234.
C Type-A USB Port: Use this port to connect the included E2MT module for
monitoring ambient temperature conditions.
Note: Do not connect a keyboard or mouse to this port.
D Reset Button: The reset button is recessed, accessible through a small hole
under the RJ45 network port. Use a paper clip or other suitable object to press
the reset button for 3 seconds to reboot the network interface. Rebooting the
network interface will not erase network settings or interrupt AC power. Press and
hold the reset button for 20 seconds to restore the network interface to its factory
default settings. Restoring to the factory default will erase all previously saved
data—including network settings—without interrupting AC power.
E Status LED: LED Function Table Shows SRCOOLNET2LX status. See the for a
description of LED behavior.
A
D EA1 A2
B C
18-06-379-93387E.indb 10 7/26/2018 4:20:00 PM

Termékspecifikációk

Márka: Tripp Lite
Kategória: nincs kategorizálva
Modell: SRCOOLNET2LX

Szüksége van segítségre?

Ha segítségre van szüksége Tripp Lite SRCOOLNET2LX, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Tripp Lite

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025
IFM

IFM PG1704 Útmutató

9 Április 2025