Owner’s Manual
SmartPro®
Medical-Grade UPS Systems
(with Lithium Iron Phosphate Batteries)
Models:
Important Safety Instructions 2
Package Contents 5
Connecting the Batteries 6
Quick Installation 7
Basic Operation 9
Guidance and Manufacturer’s Declaration 12
Storage and Service 13
Regulatory Compliance and 14
Product Registration
Español 15
Français 30
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2016 Tripp Lite. All rights reserved.
SMART700HGL
(Series Number: AG-8863)
SMART1200XLHGL
(Series Number: AG-8862)
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
16-07-004-933608.indb 1 8/31/2016 9:59:30 AM

2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings may affect
your warranty.
Statement of Intended Use
Tripp Lite Medical-Grade UPS Systems are intended to support and protect non-medical and
medical computer equipment and medical devices that require leakage current reduction, surge
protection, voltage regulation, line noise filtering and battery backup during power outages and
generator testing, both inside and outside patient care areas. Tripp Lite Medical-Grade UPS Systems
come with hospital-grade plugs and receptacles that reduce leakage to below 100μA.
Product Information
SMART700HGL SMART1200XLHGL
AC Input Voltage 120 120
AC Input Voltage Range 81–143 81–143
Input Amp(s) 5.5 9.2
Output Amp 5.8 6.25
Rated Power (VA/Watts) 700VA/450W 1000VA/750W
Frequency 60 Hz 60 Hz
No. of Phases Single Single
Class Type Class I Class I
Plug/Connector Type NEMA 5-15P NEMA 5-15P
Operation Continuous Continuous
AC Input Protection (Qty./type/rating) Input breaker
(2 x 10A), thermal
Input breaker
(2 x 15A), thermal
Max Leakage Current (uA) Less than 100uA Less than 100uA
Weight 33.7 lb. (15.3 kg) 33.6 lb. (15.2 kg)
Known Contraindication None None
UPS Location Warnings
Relevant Symbols
Denotes that information in the manual should be reviewed before use.
Used to signal a warning that a statement is particularly important and could pose a safety
risk.
Warning—Dangerous Voltage No sitting
Denotes general warning sign No stepping on surface
Refer to Instruction Manual/Booklet No pushing
16-07-004-933608.indb 2 8/31/2016 9:59:31 AM

3
Important Safety Instructions continued
• Do not use this equipment within oxygen-enriched atmospheres, or within 1 ft. (0.3 m) of a point
at which an oxygen-enriched atmosphere is intentionally vented.
• Use caution when lifting UPS. Because of the considerable weight of all UPS systems, at least
two people should assist in lifting and installing them.
• Install the UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, the UPS should be used in a location that meets the following conditions:
Temperature: 32 to 104° F (0 to 40° C); Humidity: 0 to 95% (non-condensing);
Elevation: <6,562 ft. (2,000 m) above sea level.
• Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents
or fan openings.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner
will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered
under warranty.
• UPS is not intended for patient contact. Avoid installation that will cause accidental patient
contact.
UPS Connection Warnings
• The UPS contains its own energy source (battery). The output terminals may be live even when
the UPS is not connected to an AC supply.
• Connect the UPS to a properly grounded AC power outlet. Do not modify the UPS plug in a
way that would eliminate its connection to ground. Do not use adapters that eliminate the UPS
connection to ground.
• Do not plug the UPS into itself; this will damage the UPS and void your warranty.
• If connecting the UPS to a motor-powered AC generator, the generator must provide filtered,
frequency-regulated output.
• To remove the UPS from the supply mains, the plug serves as a disconnect device.
• Once connected, do not limit access to the input plug. The plug must be accessible to be used as
a means of disconnection.
• When connecting the UPS to a power outlet, ensure the power outlet is provided with suitable
overcurrent protection in accordance with national and local electrical codes. Ensure the
overcurrent protection has a minimum of 1500A breaking capacity.
CAUTION: Do not remove cover for 5 minutes after disconnecting all sources of
supply. Risk of electric shock—hazardous live parts inside. Do not remove cover.
No user serviceable parts inside. Refer servicing to qualified service personnel.
This UPS receives power from more DC sources; disconnection of the AC and DC
source is required to de-energize the unit before servicing.
CAUTION: To ensure proper grounding with supply mains power, the input cord must
be connected with an approved country-specific plug with a protective earth ground
connection.
CAUTION: If this product is operated on battery (not connected to mains power),
adequate safeguards should be employed to protect against accidental contact
with AC power conductors.
CAUTION: Do not exceed total rated output.
WARNING: No modification of this equipment is allowed.
16-07-004-933608.indb 3 8/31/2016 9:59:31 AM
Termékspecifikációk
Márka: | Tripp Lite |
Kategória: | UPS |
Modell: | SmartPro SMART700HGL |
Szüksége van segítségre?
Ha segítségre van szüksége Tripp Lite SmartPro SMART700HGL, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók UPS Tripp Lite

31 December 2025

9 Október 2024

9 Október 2024

4 Október 2024

19 Szeptember 2024

10 Szeptember 2024

8 Szeptember 2024

30 Augusztus 2024

13 Augusztus 2024

12 Augusztus 2024
Útmutatók UPS
- UPS Ikea
- UPS AEG
- UPS Lenovo
- UPS Siemens
- UPS Voltcraft
- UPS Digitus
- UPS LC-Power
- UPS Dell
- UPS Conceptronic
- UPS Hikvision
- UPS V7
- UPS GYS
- UPS Gembird
- UPS APC
- UPS CyberPower
- UPS Emerson
- UPS Schneider
- UPS PowerWalker
- UPS Eaton
- UPS Altronix
- UPS Equip
- UPS Adj
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS LevelOne
- UPS Jung
- UPS East
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Murr Elektronik
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS FSP/Fortron
- UPS Online USV
Legújabb útmutatók UPS

9 Április 2025

9 Április 2025

3 Április 2025

3 Április 2025

31 Március 2025

31 Március 2025

31 Március 2025

30 Március 2025

29 Március 2025

29 Március 2025