Information for Lot 9 of d )ErP (Eco esign
This addendum addresses E European Union (EU) codesign requirements for servers and storage
products addendum product. All and ratings within this data are in reference only Supermicro to the (s) in
the manual. The below information conforms ommission to requirements laid down Cin Annex II of the
R . egulation 2019/424
3(1)(a): e See Section 1.1 of th system manual for the product type.
3(1)(b): See the title page and preface of the system manual for the trademark and
manufacturer’s address.
3(1)(c): (s). See the title page of the system manual for product model number
3(1)(d): . See the serial number on the physical system to determine the year of manufacture
3(1)(e-j): PSU E actor V ) (F fficiency and Power F alue (Table rom 80 Plus report)
PSU Model #: PWS- -706P 1R
Watts: 2200W
PSU E fficiency
Power
F actor
% of R Lated oad
% % % %10 20 50 100
50 %
Single O - )utput (AC DC
93.3%
9 % 6.07
96.26%
94.37 %
0.99
E P System (EUT) fficiency in I Sdle tate ower (Table)
Representative
Configurations
Measured Idle State
Power (W)
Calculated Idle Power
Allowance per Node (W)
High nd -E Performance
C onfiguration
406.1
472.44
Typical Configuration
361.9
448.94
Low erformance -E Pnd
C onfiguration
332.6
196.16
System E P(EUT) fficiency in A Sctive tate ower (Table)
Representative
Configurations
Active tate S
E Score fficiency
(Effserver)
Minimum A Sctive tate
Efficiency for 2-Socket
S erver
High nd -E Performance
C onfiguration
39
Typical Configuration
39.1
8
Low erformance -E Pnd
C onfiguration
18.9

3(1)( is k): The operating condition class A2.
Dry bulb °Ctemp
Humidity range, non-condensing
Operatin
g
condition
l
Allowable
range
Recom
mende
d range
Allowable range
Recommended
range
Max dew
point (°C)
Maximum
rate of
change
(°
C/hr)
A1
15- 32
18-27
–
12 (DP) °C P Dew oint and
8 %
relative humidity to (RH)
17 ° C DP and 80 % RH
–
9 °C DP to
15 °C DP and
60 % RH
17
5/20
A2
10-35
18-27
–
12 °C and 8 % DP RH to
21 °
C and % DP 80 RH
Same A1 as
21
5/20
A3
5-40
18-27
–
12 °C and 8 % DP RH to
24 °
C and % DP 85 RH
Same A1 as
24
5/20
A4
5-45
18-27
–
12 °C and 8 % DP RH to
24 °
C and % DP 90 RH
Same A1 as
24
5/20
3(1)(l): The idle state power at the higher boundary temperature of the operating conditions
class is 406.1W.
3(1)( is 39m): The active state efficiency and performance .
3(1)(n): There are two methods by which a user can securely delete data from this system. The
user performing secure data deletion should be an IT professional.
The first is with a Unified Extensible Firmware Interface (UEFI) shell utility. This utility
works on X10/X11/H11/H12/M11 motherboard series with onboard SATA/NVMe
devices. Any user may access and download this utility through following link:
https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Sec
ure_Data_Deletion_Utility/
Download the shell utility package and extract it to a USB flash drive, then plug the drive
into the server for which secure data deletion is necessary. Then turn the system on.
Navigate to the BIOS setup menu, then place the server system into the UEFI shell
environment. Follow the instructions in the README file to invoke the utility and
complete the deletion.
The second method is through the secure data deletion tool provided by the original
manufacturer of the hard drive. This should be used in a scenario where the shell utility
is not applicable. Each manufacturer should have the tool available on their website. If
needed, please look on the hard drive label for the name of the manufacturer and
model information.
3(1)(o): . List of recommended combinations of FatTwin servers with chassis: N/A
3(1)(p) : - -RT. List of all current SKUs within this product family SYS F619P2

3(3)(a): There is no use of cobalt in batteries in this product.
The indicative weight range of eodymium in the HDD is if manufactured by Western n 0.0
Digital, and is 25 grams if manufactured by Seagate.between 5-
3(3)(b): s.Please see the disassembly instructions on the next page
Termékspecifikációk
Márka: | Supermicro |
Kategória: | szerver |
Modell: | SuperServer F619P2-RT |
Szüksége van segítségre?
Ha segítségre van szüksége Supermicro SuperServer F619P2-RT, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók szerver Supermicro

12 Január 2025

12 Január 2025

11 Január 2025

9 Január 2025

29 December 2024

29 December 2024

29 December 2024

29 December 2024

29 December 2024

29 December 2024
Útmutatók szerver
- szerver Sony
- szerver Fujitsu
- szerver Acer
- szerver StarTech.com
- szerver Lenovo
- szerver Toshiba
- szerver HP
- szerver Medion
- szerver Vimar
- szerver Technics
- szerver Rocstor
- szerver Digitus
- szerver TRENDnet
- szerver Dell
- szerver Gigabyte
- szerver Tripp Lite
- szerver Conceptronic
- szerver Blackmagic Design
- szerver Hikvision
- szerver Netgear
- szerver Asus
- szerver ELAC
- szerver Synology
- szerver ZyXEL
- szerver Smart-AVI
- szerver Planet
- szerver Ernitec
- szerver Black Box
- szerver MSI
- szerver Cisco
- szerver ATen
- szerver APC
- szerver SEH
- szerver Western Digital
- szerver HGST
- szerver D-Link
- szerver Monacor
- szerver Moxa
- szerver Abus
- szerver Veritas
- szerver Atlona
- szerver Lindy
- szerver Areca
- szerver QNAP
- szerver NEC
- szerver Siig
- szerver Eaton
- szerver Gefen
- szerver Kathrein
- szerver IStarUSA
- szerver Lantronix
- szerver Provision-ISR
- szerver Axis
- szerver NETSCOUT
- szerver Sitecom
- szerver ACTi
- szerver Megasat
- szerver KanexPro
- szerver Kramer
- szerver Allnet
- szerver SilverStone
- szerver Maxdata
- szerver AVerMedia
- szerver Matrox
- szerver Flir
- szerver Buffalo
- szerver GeoVision
- szerver LevelOne
- szerver LaCie
- szerver Valcom
- szerver Asustor
- szerver Intel
- szerver Fantec
- szerver Freecom
- szerver Seagate
- szerver Iomega
- szerver Digi
- szerver Revox
- szerver Luxman
- szerver Ibm
- szerver Sonnet
- szerver TAIDEN
- szerver Advantech
- szerver Extron
- szerver Avocent
- szerver Intellinet
- szerver Teradek
- szerver Silex
- szerver Hanwha
- szerver In Win
- szerver Sun
- szerver MvixUSA
- szerver Dual Bay
- szerver Raidsonic
- szerver EMC
- szerver Infortrend
- szerver Opengear
- szerver G-Technology
- szerver EXSYS
- szerver Chenbro Micom
- szerver Middle Atlantic
- szerver Mr. Signal
- szerver Atlantis Land
- szerver C2G
- szerver Promise Technology
- szerver Mobotix
- szerver Origin Storage
Legújabb útmutatók szerver

9 Április 2025

3 Április 2025

2 Április 2025

29 Március 2025

29 Március 2025

29 Március 2025

24 Március 2025

24 Március 2025

15 Január 2025

15 Január 2025