Használati útmutató StarTech.com IMC1GSFP

Olvassa el alább 📖 a magyar nyelvű használati útmutatót StarTech.com IMC1GSFP (2 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 4 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/2
Quick-Start Guide
To view manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support.
Manual Revision: June 2, 2020 2:55 PM
Product Diagram (IMC1GSFP)
Component Function
1PWR LED
An external is Green: DC Power Source
detected.
An external is not O: DC Power Source
detected.
2RJ45 Port
Connect a to the Network Device Media
Converter.
Green LED:
A is detected.On: Network Device
The is Flashing: Media Converter
transmitting/receiving data.
3DIP Switch
DIP 1:
Enables Link Fault Pass Through (LFP) On:
function. LFP highlights link failures, by forcing
a link down between both connections during
a link failure.
Disables LFP function (default).O:
DIP 2:
Sets SFP speeds to 1000Mbps (default).On:
Sets SFP speeds to 100Mbps.O:
4SFP LED
Indicates that a link is detected on the Green:
SFP.
Indicates that data is being Flashing:
transmitted or received.
5SFP Slot Connect an (100/1000BASE-X) to the SFP
Media Converter.
Industrial RJ45 to Open SFP Media Converter | 1000 Mbps (1G)
64-Pin Terminal Block
Connect an external (12-56V DC Power Source
DC Input) to the .Media Converter
Connect an alarm or warning circuit to the
relay (ALM) connection. The relay is triggered if
the loses power.Media Converter
7Ground Screw
Connect a ground connection to the Ground
Screw DC Power Source when connecting a to
the .Media Converter
Requirements
For the latest requirements, please visit www.startech.com/IMC1GSFP
Network Equipment (ex. Router, Network Switch) x 1
MSA-Compliant 100/1000BASE-X SFP Transceiver Module x 1
RJ45 Terminated UTP/STP CAT5e (or better) Network Cable x 1
Terminated Fiber Optic Cable (dependent on SFP Module) x 1
DC Power Source x 1
Phillips Head Screwdriver x 1
Small Flat Head Screwdriver x 1
Alarm or Warning Circuit x 1
Powering the Media Converter
Connecting and installing the must be completed by a 4-Wire Terminal Connector
licensed Electrician.
Notes: Make sure that you turn o the power source before connecting the power wire
to the .Media Converter
Do not exceed the recommend power source voltage as it may result in personal or
product damage.
1. Using a , loosen the two screws (+V-) on the Small Flat Head Screwdriver 4-Wire
Terminal Connector (included).
2. Connect the from a (12 - 56V DC), or the provided Power Wires DC Power Source
Barrel Power Connector Adapter Terminal Block Connectors to the proper on
the . The terminals are marked on the Media Converter Media Converter’s Casing
(connect the positive wire to V+ and the negative wire to V-).
3. (Optional) Using a , loosen the two screws (ALM) on Small Flat Head Screwdriver
the .4-Wire Terminal Connector
1 2 3 5 6 7
4
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modications not expressly approved by StarTech.com could void the user’s authority to operate the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.
CAN ICES-3 (A)/NMB-3(A)
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-
party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only
and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which
this manual applies by the third-party company in question. StarTech.com hereby acknowledges that all trademarks, registered
trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the
property of their respective holders.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer to .
www.startech.com/warranty
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their ocers, directors, employees or agents)
for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of prots, loss of
business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the product.
Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the limitations
or exclusions contained in this statement may not apply to you.
FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom
StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.
3. Using a , tighten the . Be careful not to Phillips Head Screwdriver Mounting Screws
over-tighten the .Mounting Screws
4. Clip the onto a , securing the .DIN Rail Bracket DIN Rail Media Converter
Wall Mounting
It is recommended that you use when wall mounting the Wall Studs Media
Converter.
1. Align the (x 2) with the (x 4) on the side of the Mounting Brackets Mounting Holes
Media Converter.
2. Insert the (x 4) through each of the and into Mounting Screws Mounting Brackets
the .Media Converter
3. Align the on the wall in the position you want to mount the Media Converter
Media Converter.
4. Using a mark o both of the on theWriting Utensil Mounting Holes Media
Converter.
5. Using a draw a line connecting the two , making sure that Level Mounting Holes
the line is level.
6. Align the on the with the Mounting Holes Media Converter Mounting Hole
Marks.
7. Insert the (x 2) through the and into the .Mounting Screws Mounting Holes Wall
8. Using a tighten the until the Phillips Head Screwdriver Mounting Screws Media
Converter Wall is securely fastened to the .
Product Dimensions
4. (Optional) Connect the from an or to the Relay Wires Alarm Warning Circuit 2 ALM
Relay Pins Terminal Block Connector on the .
5. Using the , tighten the four screws on the Small Flat Head Screwdriver 4-Wire
Terminal Connector.
6. Insert the in the on the 4-Wire Terminal Connector 4-Wire Terminal Block Media
Converter.
7. Using a , loosen the on the Phillips Head Screwdriver Ground Screw Media
Converter.
8. Connect the from an to the Ground Wire Earth Ground Connection Ground Screw
on the . Media Converter
9. Using the , tighten the to secure thePhillips Head Screwdriver Ground Screw
Grounding Wire Media Converter.to the
(Optional) Barrel Connector
Connect a from a Type N (OD: 5.5 mm, ID: 2.5 mm) Barrel Connector Universal
Power Adapter Terminal Block to Barrel Power Connector Adapter. to the
Connecting the Media Converter
1. Connect a to the on the and the other CAT5e/6 Cable RJ45 Port Media Converter
end to an RJ45 port on a .Network Device
2. Insert an (sold separately) into the MSA-Compliant SFP Transceiver Module SFP
Slot Media Converter on the .
3. Remove the from the and connect the appropriate cable Dust Cover SFP Module
(CAT5e/6 or Fiber).
Mounting
DIN Rail Mounting
1. Align the (x 1) with the (x 4) on the side of the DIN Rail Brackets Mounting Holes
Media Converter.
2. Insert the (x 3) through the and into the Mounting Screws DIN Rail Bracket Media
Converter.

Termékspecifikációk

Márka: StarTech.com
Kategória: nincs kategorizálva
Modell: IMC1GSFP

Szüksége van segítségre?

Ha segítségre van szüksége StarTech.com IMC1GSFP, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva StarTech.com

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva