HC/HS/SA-Series
2D Image Scanner
User Manual
Version: B0
i
Contents
INTRODUCTION ................................................................................................................. - 5 -
1. GENERAL OPTIONS....................................................................................................... - 7 -
1.1. Restore to Factory Default Settings ............................................................................ - 7 -
1.2. Switch User Interface and Reset to Default Settings .................................................. - 8 -
1.3. Check Firmware Version ............................................................................................ - 8 -
1.4. Enhance Barcode Scanning on Screens ...................................................................... - 9 -
1.4.1 No illumination detection ..................................................................................... - 9 -
1.4.2 Prevention of icker ............................................................................................. - 9 -
1.4.3 Prevention of specular reection .......................................................................... - 9 -
1.5. Congure Data Transmission Interval ....................................................................... - 9 -
2. INTERFACE ................................................................................................................... - 11 -
2.1. Keyboard wedge/USB options ................................................................................. - 11 -
2.1.1. Keyboard language ............................................................................................ - 12 -
2.1.2. Special options................................................................................................... - 13 -
2.1.3. Intercharacter delay for wedges/USB ................................................................ - 15 -
3. CODE OPTIONS ............................................................................................................ - 16 -
3.1. Setting of readable codes .......................................................................................... - 17 -
3.1.1. Disabling of readable codes ............................................................................... - 17 -
3.1.2. Enabling of readable codes ................................................................................ - 19 -
3.2. Setting of number of characters ................................................................................ - 22 -
3.3. Setting code specic options .................................................................................... - 26 -
3.3.1. Options for UPC-A ............................................................................................ - 28 -
3.3.2. Options for UPC-E ............................................................................................ - 29 -
3.3.3. Options for EAN-13 and EAN-8 ....................................................................... - 30 -
3.3.4. Options for Code 39 and It. Pharm. ................................................................... - 33 -
3.3.5. Options for Codabar .......................................................................................... - 36 -
3.3.6. Options for 2of5 and S-Code ............................................................................. - 39 -
ii
3.3.7. Options for IATA .............................................................................................. - 42 -
3.3.8. Options for MSI/Plessey .................................................................................... - 42 -
3.3.9. Options for Telepen ........................................................................................... - 44 -
3.3.10. Options for UK/Plessey ................................................................................... - 45 -
3.3.11. Options for Code 128 and GS1-128 ................................................................ - 45 -
3.3.12. Options for Code 93 ........................................................................................ - 47 -
3.3.13. Options for Code 11 ........................................................................................ - 48 -
3.3.14. Options for Korean Postal Authority code ...................................................... - 49 -
3.3.15. Options for Intelligent Mail Barcode ............................................................... - 50 -
3.3.16. Options for POSTNET .................................................................................... - 51 -
3.3.17. Options for GS1 Databar ................................................................................. - 51 -
3.3.18. Options for Composite Codes.......................................................................... - 53 -
3.3.19. Options for Codablock F ................................................................................. - 55 -
3.3.20. Options for DataMatrix ................................................................................... - 55 -
3.3.21. Options for Aztec ............................................................................................ - 57 -
3.3.22. Options for Chinese Sensible code .................................................................. - 58 -
3.3.23. Options for QR Code ....................................................................................... - 59 -
3.3.24. Options for Micro QR Code ............................................................................ - 60 -
3.3.25. Options for Maxicode ...................................................................................... - 61 -
3.3.26. Options for PDF417 ........................................................................................ - 62 -
3.3.27. Options for MicroPDF417 ............................................................................... - 63 -
4. STRING OPTIONS ......................................................................................................... - 65 -
4.1. Case conversion ........................................................................................................ - 65 -
4.2. Set prex and sux ................................................................................................. - 66 -
4.2.1. Set prex ........................................................................................................... - 73 -
4.2.1.1. Direct input keyboard keys ................................................ - 73 -
4.2.1.2. Direct input numeric .......................................................... - 77 -
4.2.1.3. Direct input character ......................................................... - 78 -
4.2.1.4. Direct input lower case character ....................................... - 80 -
iii
4.2.1.5. Direct input control character ............................................ - 82 -
4.2.1.6. Direct input code id/length................................................. - 84 -
4.2.2. Set sux ............................................................................................................ - 84 -
4.2.2.1. Direct input keyboard keys ................................................ - 84 -
4.2.2.2. Direct input numeric .......................................................... - 89 -
4.2.2.3. Direct input character ......................................................... - 89 -
4.2.2.4. Direct input lower case character ....................................... - 91 -
4.2.2.5. Direct input control character ............................................ - 93 -
4.2.2.6. Direct input code id/length................................................. - 95 -
5. READ OPTIONS ............................................................................................................ - 96 -
5.1. Read mode options ................................................................................................... - 96 -
5.1.1. Multiple read reset time ..................................................................................... - 98 -
5.1.2. Quiet zone options ............................................................................................. - 99 -
5.1.3. Auto trigger options ........................................................................................... - 99 -
5.1.4. Detection Mode ............................................................................................... - 100 -
5.1.5. Auto Trigger Condition ................................................................................... - 100 -
5.2. Read time options ................................................................................................... - 101 -
5.3. Redundancy ............................................................................................................ - 102 -
5.4. Positive and negative bar codes .............................................................................. - 102 -
5.5. Floodlight and aiming options ................................................................................ - 102 -
5.6. Prevention of icker ............................................................................................... - 103 -
5.7. LED aiming ............................................................................................................ - 104 -
6. INDICATOR OPTIONS ............................................................................................... - 105 -
6.1. Buzzer settings ....................................................................................................... - 105 -
6.2. Good read LED ...................................................................................................... - 107 -
7. MISCELLANEOUS ...................................................................................................... - 108 -
7.1. Diagnostics ............................................................................................................. - 108 -
APPENDIX A. TROUBLE SHOOTING .......................................................................... - 109 -
APPENDIX B. GLOSSARY OF TERMS ........................................................................ - 110 -
iv
- - 5
INTRODUCTION
This menu book is intended for setting up your bar code reader to optimize its
performance for your particular application. When the required options have been
congured, they remain in the reader, even after power down. The reader can be
returned to factory default by reading the default label.
Menu labels
The reader must be set by reading the bar code labels in the menu table.
Besides options, some chapters have commands. The commands need to be scanned
directly, without reading the “SET” and “END” labels. The commands are executed
directly and, unlike options, are not stored in non-volatile memory.
Recommended steps to follow for quick conguration
After checking your connection you are ready to start the conguration of your
reader.
Check connection:
Ensure that the power is disconnected from your equipment before you connect the
reader. After connecting the data cable, the power can be applied to the equipment
and the reader.
1:
Use chapter 1 to set the correct default for your reader.
* The reader is now in factory default.
2:
Use chapter 2 to optimize the interface.
* The reader is now able to read bar codes and transmit the data.
3:
Use chapter 3 to optimize the reader for the type of bar codes you use. Set the
readable codes rst and then the options for each of these codes.
* The reader is now able to read the codes you selected, validate the data using length
and check digit and transmit that part of the data you specied.
4:
Use chapter 4 to select the string options for your application. These include
transmission of code length, conversion of upper and lower case and setting a prex
and sux.
* The reader can now read and transmit the data in the required format.
- - 6
5:
Use chapter 5 to select the read options to your preference. These options aect the
read mode, read time, trigger and redundancy.
6:
Use chapter 6 to select the indicator options you prefer. These options aect the
operation of the buzzer and good read LED.
* The reader will now operate to your personal preference.
See gure 0.02.
- - 7
1. GENERAL OPTIONS
1.1. Restore to Factory Default Settings
This option allows you to undo all previously congured options and bring the
reader's conguration back to factory default settings. These factory default settings
are printed in bold.
Note that dierences may occur depending on the type of interface as will be
mentioned in the text.
Select only the correct default settings corresponding to your hardware "defaults"
label.
The interfaces supported depend on the reader model and software release. Please
consult your sales oce for not listed interfaces.
USB-HID
USB-VCP
- - 8
1.2. Switch User Interface and Reset to Default Settings
This option allows you to switch among multiple interfaces supported by
HC/HS/SA-Series 2D Image reader, including USB HID, and USB Virtual COM,
according to your needs. And, the current settings will be automatically reset to
factory default settings once the user interface is changed. To verify your
conguration, it is strongly suggested to reboot the POS terminal to achieve the
purpose.
If it still fails to change user interface, please be advised to scan the barcode again
after restarting your POS system.
USB-HID
USB-VCP
1.3. Check Firmware Version
This options allows you to retrieve the current rmware version.
Firmware Version
- - 9
1.4. Enhance Barcode Scanning on Screens
In addition to the printed barcodes, you may also aim the scanner at the desired
barcode on screens to scan and decode barcodes. This section lists three adjustable
options which are all designed to improve eiciency in scanning barcodes directly
from screens.
1.4.1 No illumination detection
With no illumination detection, a target code is detected without illumination light.
The power consumption can be reduced, but the response of detection will also be
reduced. Ambient light is used for detection in this mode, so this can not be used in a
dark place while it can be used in a lighted environment.
No illumination
detection
1.4.2 Prevention of icker
When there is no target to be read, icker occurs because of the LED illumination,
and this icker can be prevented with setting. However, it is normally suggested not
to enable LED illumination icker prevention, a feature which will make it dicult to
read barcodes on LCD screens once activated.
1.4.3 Prevention of specular reection
Only when specular reection of LED illumination occurs, the reading is performed
with the illumination turned o, which will lead to degradation of reading
performance.
Prevent specular
reection
1.5. Congure Data Transmission Interval
This option allows you to specify the interval at which the scanned data will be
transferred. In other words, this will determine how fast you want the scanned data to
be transmitted.
- - 10
How to set data transmission interval:
Please follow the example below to scan the sequence of barcode labels to set the data
transmission interval to be 2 ms:
<bInterval=2>
Restart POS system to make sure your conguration is applied successfully.
bInterval = 1
bInterval = 2
bInterval = 4
bInterval = 8
- - 11
2. INTERFACE
This chapter describes the congurable transmission options for your reader. Some
options may not be relevant to the type of reader you have. An attempt to congure
the reader for such options does not aect its operation and usually results in the
reader producing an error tone, indicating you tried to make an illegal conguration
entry.
2.1. Keyboard wedge/USB options
This paragraph describes the options which are relevant to readers with a wedge or
USB interface. The following parameters can be congured:
keyboard language
special options
intercharacter delay
Because these options are interdependent, it is important to perform the conguration
in the sequence given.
Please consult your sales oce for keyboard layouts and language currently
supported.
Keyboard wedge operation modes:
This mode enables or disables responses from PC wedge to the computer during
booting. In normal cases, the keyboard handles the responses to the computer. The PC
wedge is only listening in order to be aware of the keyboard state.
With keyboard:
Use this mode in case a keyboard is connected to the PC wedge Y-cable.
The wedge is only listening in case the computer is booting or when the wedge is idle.
- - 12
Without keyboard:
Use this mode in case no keyboard is connected to the PC wedge Y-cable. In some
cases this mode is required in case only a PC USB keyboard is connected. If this
option is enable, the computer can detect the wedge as a keyboard. In case the
computer reports a keyboard error or in case no data is displayed, try this option. It is
required to power OFF the PC, wait 10 seconds and power ON the PC again. Do not
enable this option in case a keyboard is connected to the Y-cable.
The wedge is responding to all commands from the computer.
The ‘without keyboard’ option is only supported for PC/AT wedges.
With keyboard
Without keyboard
2.1.1. Keyboard language
Keyboards are also dierent depending on country or language. Examples are the
QWERTY and AZERTY keyboards. Select the same language that has been selected
on your PC.
The languages supported depend on the reader model and software release. Please
consult your sales oce for the languages currently supported.
US
UK
German
French
French Macintosh
Italian
Spanish
- - 13
Portuguese
Swiss ( French )
Swiss ( German )
Dutch
Belgian
Swedish
Finnish
Danish
Norwegian
Japanese
Czech
2.1.2. Special options
This section contains some specialized keyboard options.
Do not use numpad:
The reader wil emulate the numerical keys on the alpha keypad when transmitting
numerical data.
Use numpad:
The reader will emulate the numerical keypad when transmitting numerical data. The
NUMLOCK should always be ON when this option has been selected.
Auto NumLock mode:
When selecting this option, the bar code reader automatically uses the correct
NumLock state.
- - 14
No CAPSLOCK mode:
This options cancels the CAPSLOCK mode.
CAPSLOCK mode:
This option ensures that data is displayed correctly when the keyboard is normally in
CAPSLOCK mode. The keyboard is returned in the CAPSLOCK mode after
transmission.
Auto CAPSLOCK mode:
When selecting this option, the transmitted data is displayed correctly, disregarding
the CAPSLOCK state.
Do not use numpad
Use numpad
Auto numlock mode
No CAPSLOCK mode
CAPSLOCK mode
Auto CAPSLOCK mode
- - 15
2.1.3. Intercharacter delay for wedges/USB
The intercharacter delay can be used to adapt the reader's data transmission speed to
the system. If the transmission speed is too high, the system may not be able to
receive all characters. Adjust the intercharacter delay until the data is received
correctly. The default value as well as the actual delay time depend on the terminal
type and language selected.
No delay
Delay = 1
Delay = 2
Delay = 3
Delay = 4
Delay = 5
Delay = 6
Delay = 7
Delay = 8
Delay = 9
Delay = 10
- - 16
3. CODE OPTIONS
The menu options in this chapter are intended to adjust the decoding settings of the
reader:
which bar code types can be read
the permissible length of the bar codes to be read
bar code specic options
Note:
This manual categorizes the barcodes as groups of dierent symbologies with their
translations and sometimes with relations to other family names. The next gure
visualizes how code translations and relations are maintained in this Code options
chapter. See gure 3.00.
- 17 -
3.1. Setting of readable codes
These options do not aect the reading of the menu labels. The required bar code
types can be selected by enabling a single readable code only and enabling readable
codes.
It is strongly recommended to select only the required codes.
Advantages of selecting only the required codes are:
faster reading
no accidental scanning of unwanted bar codes
reduced probability of reading errors which cannot be prevented completely,
because of the limited security of some bar code types
Some bar codes are translations or special variants of other bar code types. The table
on the title page of this chapter visualizes these relations. The setting of dierent
codes is explained in the next chapter 3.1.1. Enabling a single read. code.
3.1.1. Disabling of readable codes
With this option you can set the reader to disable the specic symbology. If you select
'Disable Code 39', Code 39 will not be read.
- - 18
Disabling of readable codes
Disable UPC
Disable EAN
Disable Code 39
Disable Codabar
Disable Industrial 2of5
Disable Interleaved 2of5
Disable Chinese Post Matrix 2of 5
Disable Korean Postal
Authority code
Disable POSTNET
Disable IATA
Disable MSI/Plessey
Disable Telepen
Disable UK/Plessey
Disable Code 128
Disable Code 93
Disable Code 11
- - 19
Disable GS1-Databar
Disable GS1-Databar Limited
Disable GS1-Databar Expanded
Disable Codablock F
Disable DataMatrix ECC000 - 140
Disable DataMatrix ECC200
Disable Aztec
Disable Aztec runes
Disable Chinese Sensible code
Disable QR Code
Disable Micro QR Code
Disable Maxicode
3.1.2. Enabling of readable codes
With this option you can set the reader to read a number of bar code types or simply
enable additional bar code types.
- - 20
Enabling of readable codes
All codes excl. add-on
Enable UPC
Enable UPC + 2
Enable UPC + 5
Enable EAN
Enable EAN + 2
Enable EAN + 5
Enable Code 39
Enable Tri-Optic
Enable Codabar
Enable Industrial 2of5
Enable Interleaved 2of5
Enable S-Code
Enable Matrix 2of5
Enable Chinese Post Matrix
2of5
- - 21
Enable Korean Postal
Authority code
Enable Intelligent Mail
Barcode
Enable POSTNET
Enable IATA
Enable MSI/Plessey
Enable Telepen
Enable UK/Plessey
Enable Code 128
Enable Code 93
Enable Code 11
Enable GS1-Databar
Enable GS1-Databar Limited
Enable GS1-Databar
Expanded
Enable Codablock F
Enable DataMatrix ECC000 -
140
- - 22
Enable DataMatrix ECC200
Enable Aztec
Enable Aztec runes
Enable Chinese Sensible code
Enable QR Code
Enable Micro QR Code
Enable Maxicode
Enable PDF417
Enable MicroPDF417
Enable all 1D codes
Enable all 2D codes
3.2. Setting of number of characters
If you are going to read bar codes of known length, it is recommended to set the
reader for a xed number of characters. This can be done for up to two lengths. The
reader uses this to verify that labels read are of the correct length, rejecting any labels
which do not have the specied length. The advantage of setting a xed length, is that
it provides protection against short scans of labels, such as Interleaved 2of5, which do
not provide sucient security against partial scan. The length checking is done on the
label data and is not aected by options such as (not) transmit start/stop character or
check digit. Setting the number of characters does not aect xed length codes, such
as EAN-13. 2D symbologies such as PDF417 and Data Matrix are also not aected
- - 23
by xed length settings.
The following options are available:
Fixed length OFF all codes.
This option cancels the xed length checking.
Fixed length ON all codes.
This option enables the xed length checking. Two xed lengths are programmed
which will aect all variable length codes. This is done by reading the following
labels:
<Fixed length ON - all code s>
a bar code with the required length, a second bar code with the required length (this
may be the same length as the rst one)
It is possible to congure a xed length or a minimum and a maximum length for
selected symbologies by reading the respective option followed by a barcode label
with the required length. The dierent functions may be combined and will be used as
follows:
if a label is checked for xed length, it will not be checked for minimum or
maximum length
if a label is not checked for xed length it will be checked for both minimum and
maximum length
By reading an option followed by the 'END' label, the function is disabled or the
values for that option are reset to their default. The default values are:
xed: disabled, thus no xed length checking
minimum: according to the next gure (The minimum length of the 2of5 bar
code types can not be changed independent.)
maximum: disabled, thus no maximum length checking. (The maximum length is
reader dependent)
- - 24
See gure 3.07.
Fixed length ON for selected codes:
This option enables xed length checking for dierent bar code types and will only
aects the bar code types read. The number of xed lengths which can be congured
is reader dependent.
<Fixed length ON for selected codes>
Scan bar codes of the required type and length
Example:
The 2 examples shown in the next gure have the following results: In the rst
example only Code 39 labels will be checked for a length of 6 characters. Any other
bar code type will not be checked for xed length. In the second example Code 39
labels will be checked for a length of 6 characters and interleaved 2of5 labels for a
length of 12 characters. This implies that also Industrial 2of5, Matrix 2of5 and
S-Code are checked for a xed length of 12 characters. Any other bar code type will
not be checked for xed length.
Minimum length for selected codes:
This option modies the default minimum length table. The number of minimum
lengths which can be congured is reader dependent. This is done by reading the
following labels:
<Minimum length for selected codes>
Scan bar codes of the required type and length
- - 25
Example:
The two examples shown in the next gure have the following result: In the rst
example only Code 39 labels will be checked for a minimum length of 2 characters.
All other bar code types will be checked for a minimum length as displayed in the
next gure.
In the second example Code 39 labels will be checked for a minimum length of 2
characters and interleaved 2of5 labels for a minimum length of 4 characters. This
implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a minimum
length of 4 characters. All other bar code types will be checked for a minimum length.
Maximum length for selected codes:
This option enables the maximum length checking. The number of maximum lengths
which can be congured is reader dependent. This is done by reading the following
labels:
<Maximum length for selected codes>
Scan bar codes of the required type and length
Example:
The two following examples shown in the next gure have the following result: In the
rst example only Code 39 labels will be checked for a maximum length of 12
characters. Any other bar code types will not be checked for a maximum length. In
the second example Code 39 labels will be checked for a maximum length of 12
characters and Interleaved 2of5 labels for a maximum length of 14 characters. This
implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a maximum
length of 14 characters. Any other bar code types will not be checked for a maximum
length.
Serial programming:
To set a length using serial commands, the sequence is as follows:
<ESC>
<command>
<SPACE>*<CodeID>*
<Length 1>
<Length 2**>
<CR>
*(if required by <command>)
**(length 2 may be the same length as length 1, when only one length is required)
- - 26
Example:
Setting xed length for all codes, lengths 8, 10 and 12:
<ESC>H1081012<CR>
Setting minimum length for selected codes, for Code 39 with a length of 2:
<ESC>HL V02<CR>
Setting maximum length for selected codes, for Code 39 with a length of 12 and
Interleaved 2of5 with length of 14:
<ESC>HM V12 N14<CR>
Setting of number of characters
Fixed length OFF
all codes
Fixed length ON all codes
Fixed length ON for
selected codes
Minimum length for
selected codes
Maximum length for
selected codes
3.3. Setting code specic options
Code specic options may be congured aecting:
enabling and disabling code variants and translations, such as EAN-128, as were
listed in the relations table for setting of readable codes
data verication such as by means of a check digit calculation. A check digit has
a value that can be calculated from the other data characters and is usually the
last data character in a bar code
pre-editing of the data string such as removing the check-digit and/or start/stop
characters
- 27 -
The more common options are described here:
Check CD:
This option enables the check digit calculation. If the calculated check digit does not
correspond to the check digit in the bar code, then the bar code is ignored. The use of
a check digit greatly improves the security of a bar code.
Not check CD:
This option disables the check digit calculation. This option is required when the bar
codes do not contain a check digit or contain an invalid check digit.
Transmit CD:
This option enables the transmission of the check digit together with the data
characters. If the check digit calculation is disabled, the reader can not dierentiate
anymore between a (valid) check digit and a data character. It will therefore transmit
all data characters of the label, including what could constitute a check digit.
Not transmit CD:
This option disables the transmission of the check digit. If the check digit calculation
is disabled, the reader can not dierentiate between a (valid) check digit and a data
character. It will therefore transmit all data characters of the label, excluding the
character that could constitute the check digit for the type of bar code.
Transmit ST/SP:
This option enables the transmission of the start and stop characters of a bar code.
Not transmit ST/SP:
This option disables the transmission of the start and stop characters of a bar code.
The next gure summarizes the eect of the transmit options for a Code 39 label
with:
start and stop characters '*'
data characters '1 2 3 4 5 6'
or data characters '1 2 3 4 5' and check digit '6'
Note that because '6' is, according to the Code 39 specications, not a valid check
digit for this label. The check digit calculation must therefore be disabled in order for
the label to be accepted.
See gure 3.11.
- - 28
3.3.1. Options for UPC-A
The UPC-A symbology is a xed length symbology encoding 11 data digits, a check
digit and non-printable start/stop characters. The following characters are supported:
the digits 0 up to 9
An optional leading zero can be transmitted, which together with the data and the
check digit forms a 13 digit eld providing compatibility with the EAN-13 format.
For string format see gure 3.12.
UPC-A add-on 2/add-on 5:
The UPC-A symbology as described above can be succeeded by an additional 2 or 5
digit UPCA code. For string format see gure 3.13.
Options for UPC- A:
disable transmission of the leading zero
disable transmission of the check digit
UPC-A, No leading
zero, transmit CD
UPC-A, No leading zero,
not transmit CD
- - 29
UPC-A, Leading
zero, transmit CD
UPC-A, Leading zero, not
transmit CD
3.3.2. Options for UPC-E
The UPC-E symbology is a xed length symbology encoding 6 data digits, a check
digit and non printable start/stop characters. The following characters are supported:
the digits 0 upto 9
An optional leading digit can be transmitted, which together with the data and the
check digit forms an 8 digit eld providing a compatibility with the EAN-8 format.
For string format see gure 3.14.
UPC-E add-on 2/add-on 5:
The UPC-E symbology as described above can be succeeded by an additional 2 or 5
digit UPCE code. For string format see gure 3.15.
UPC-E0 stands for UPC version E0 and the rst digit is always a '0'. UPC-E1 stand
for UPC version E1 and the rst digit is a '1'. Options for UPC-E0 aects UPC-E1 too.
Support for UPCE1 is reader dependent.
Options for UPC- E:
enable transmission of the leading digit
disable transmission of the check digit
transmit UPC-E as UPC-A
Transmit UPC-E as UPC- A:
If this option is enabled, a UPC-E label is transmitted in the UPC-A format.
- - 30
Options for UPC-E
UPC-E, No leading
digit, transmit CD
E7
UPC-E, No leading digit, not transmit
CD
UPC-E, Leading digit,
transmit CD
UPC-E, Leading digit, not transmit
CD
Transmit UPC-E as is
Transmit UPC-E as UPCA
3.3.3. Options for EAN-13 and EAN-8
EAN-13:
The EAN-13 symbology is a xed length symbology encoding 12 data digits, a check
digit and non-printable start/stop characters. The following characters are supported:
the digits 0 upto 9
The data may be translated into ISBN, ISSN or ISMN format. For string format see
gure 3.16.
EAN-13 add-on 2/add-on 5:
The EAN-13 symbology as described above can be succeeded by an additional 2 or 5
digitcode. For string format see gure 3.17.
- - 31
EAN-8:
The EAN-8 symbology is a xed length symbology encoding 7 data digits, a check
digit and non-printable start/stop characters. The following characters are supported:
the digits 0 upto 9
For string format see gure 3.18.
EAN-8 add-on 2/add-on 5:
The EAN-8 symbology as described above can be succeeded by an additional 2 or 5
digit code. For string format see gure 3.19.
Options for EAN:
disable transmission of the check digit
enable ISBN, ISSN or ISMN translation
Enable ISBN, ISSN or ISMN translation:
If this option is enabled, an EAN-13 label is veried for the correct format and
transmitted as a 10-digit ISBN number, 8 digit ISSN number. In case of ISMN, the
character M is transmitted followed by 9 digits. Support for these translations is
reader dependent.
- - 32
Options for EAN-13 and EAN-8
EAN-13 not transmit CD
EAN-13 transmit CD
EAN-8 not transmit CD
EAN-8 transmit CD
Disable ISBN translation
Enable ISBN translation
Enable ISBN if possible
Disable ISSN translation
Enable ISSN translation
Enable ISSN if possible
Disable ISMN translation
Enable ISMN translation
Enable ISMN if possible
- - 33
3.3.4. Options for Code 39 and It. Pharm.
Code 39:
Code 39 is a variable length symbology with an optional check digit and printable
start/stop characters. The following characters are supported:
the digits 0 up to 9
the upper case characters A up to Z
the characters - . $ / + % SPACE
start/stop character is *
The checksum is calculated as the sum modulo 43 of the numerical value of the data
characters. In full ASCII mode, all 128 ASCII characters are supported. This is done
by combining one of the characters +, %, $ or / with one of the alpha characters (A
upto Z). For string format see gure 3.20.
Italian Pharmaceutical:
In this mode the Code 39 data is translated to the Italian pharmaceutical format. This
format has a xed length containing 8 numeric data values followed by a single
mandatory check digit. An optional leading 'A' can be transmitted. For string format
see gure 3.21.
Options for Code 39:
enable full ASCII conversion
enable Italian Pharmaceutical conversion
enable check digit
disable transmission of the check digit
enable transmission of start/stop
enable leading A for Italian Pharmaceutical
selection of the minimum number of data characters
- - 34
Normal Code 39:
In this mode the decoded data characters are transmitted without further translation.
Full ASCII Code 39:
In this mode the decoded data characters are translated to full ASCII Code 39.
Full ASCII Code 39 if possible:
In this mode the decoded data characters are translated to full ASCII Code 39. Invalid
combinations are not translated and are transmitted as is.
Italian Pharmaceutical only:
In this mode the decoded data characters are translated to the Italian Pharmaceutical
format. If the data does not comply with the Italian Pharmaceutical format, the label is
rejected.
Italian Pharmaceutical if possible:
In this mode the decoded data characters are translated to the Italian Pharmaceutical
format. If the data does not comply with the Italian Pharmaceutical format, then the
data is transmitted as Normal or full ASCII Code 39.
Tri-Optic:
This fixed length symbology builds its data out of two data triplets, where the second
triplet is encoded at first. The following characters are supported:
the digits 0 up to 9
the upper case characters A up to Z
the characters - . / + % SPACE
start/stop character is $
For string format see figure 3.22.
There are no options for Tri-Optic supported.
Concatenation:
If a Code 39 bar code contains a leading space, the data is stored into the reader's
buffer without the leading space. As soon as a Code 39 bar code is read without a
leading space, the data is appended to the reader's buffer and the entire buffer is
transmitted and cleared for new data. In case a non Code 39 bar code is read, the data
in the non-Code 39 bar code is transmitted and the buffer is cleared. The buffer size is
reader dependent.
- - 35
Options for Code 39 and It.Pharm.
Normal Code 39
Full ASCII Code 39
Full ASCII Code 39 if possible
It. Pharmaceutical only
It. Pharmaceutical if possible
Not check CD
Check CD
Not transmit CD
Transmit CD
Not transmit ST/SP
Transmit ST/SP
Not transm. ld. A for It.
Pharm.Code
Transmit leading A for It.
Pharm.Code
Minimum 3 digits
Minimum 1 digit
Disable concatenation
- - 36
Enable concatenation
3.3.5. Options for Codabar
Codabar (NW7):
Codabar (NW7) is a variable length symbology with an optional check digit and
printable start/stop characters. The next characters are supported:
the digits 0 upto 9
the characters - $: / . +
start/stop characters are A, B, C or D
The checksum is calculated as the sum modulo 16 of the numerical values of all data
characters. For string format see gure 3.23.
ABC-Code:
The ABC code is an acronym for American Blood Commission. This code consists of
two bar codes which are decoded in one read cycle. The code is concatenated when
the stop character of the rst bar code and the start character of the second bar code is
a D. These two D's are not transmitted. For string format see gure 3.24.
CX-Code:
The CX-Code consists of two bar codes which are decoded in one read cycle. The
code is concatenated when the stop character of the rst bar code is a C, and the start
character of the second bar code is a B. The B and C characters are not transmitted.
- 37 -
For string format see gure 3.25.
Options for Codabar:
enable ABC code concatenation
enable CX code concatenation
enable check digit check
disable transmission of the check digit
disable transmission of start/stop
selection of start/stop character translation
selection of minimum number of data characters
enable library space (CLSI) insertion
Space insertion:
This option inserts spaces in position 2, 7, 13, of the data string for use in library
systems.
ST/SP translation:
This option enables the translation and transmission of the start and stop characters.
Thus if the option ST/SP: abcd/tn*e is chosen, the start character is converted to lower
case, e.g. from A, B, C or D to a, b, c, or d respectively and the stop character is
converted from A, B, C or D to t, n, *, or e respectively. The next gure shows the
resulting format for these options with a Codabar label using A and B as start and stop
characters and 1 2 3 4 5 6 as data characters. For string format see gure 3.26.
- - 38
Minimum data characters:
Codabar labels are checked for a minimum of 1, 3 or 5 characters are set by the user.
If the number of characters in the label is shorter than the number set, the label will be
rejected. If the xed length option is used for Codabar type labels then such labels
will additionally be checked for xed length.
Inter character gap check:
This option enables the reading of Codabar labels with a large or irregular gap
between characters. Checking the gap means that it is not allowed to have a gap.
Disable the gap check allows gaps in the bar code.
Options for Codabar
Enable only Codabar normal
mode
Enable only ABC code
Enable only CX code
Enable Codabar, ABC and CX
Not check CD
Check CD
Not transmit CD
Transmit CD
Disable space insertion
Enable space insertion
Not transmit ST/SP
- - 39
ST/SP: ABCD/ABCD
ST/SP: abcd/abcd
ST/SP: ABCD/TN*E
ST/SP: abcd/tn*e
ST/SP:
<DC1><DC2><DC3><DC4>/
<DC1><DC2><DC3><DC4>
Minimum data one character
Minimum data three
characters
Minimum data five characters
Disable intercharactergap
check
Enable intercharactergap
check
3.3.6. Options for 2of5 and S-Code
Code 2of5:
Code 2of5 is a variable length symbology with an optional check digit and
non-printable start and stop characters. The following characters are supported:
the digits 0 upto 9
The checksum is calculated as the sum modulo 10 of the numerical values of all the
data characters.
Industrial 2of5:
This symbology encodes a single digit in each data symbol. Information is carried in
the bars only.
- - 40
Interleaved 2of5:
This symbology encodes a pair of digits in each symbol, the number of digits are
therefore always an even number. Information is carried in the bars and spaces. The
start and stop pattern is not unique inside the code. It is therefore essential to use the
fixed length option to prevent partial reads.
S-Code:
This symbology encodes like Interleaved 2of5 but encodes the last data character as
Industrial 2of5. The number of data digits is therefore always an odd number.
Information is carried in the bars and the spaces. The start and stop pattern is not
unique inside the code. It is therefore essential to use the fixed length option to
prevent partial reads.
Matrix 2of5:
This symbology encodes 1 digit in each character, the number of digits can therefore
be an odd or an even number. Information is carried in the bars and spaces.
Chines Post Matrix 2of5:
This symbology is a variant of Matrix 2of5. To assure proper reads, check the options
and setting for (Matrix) 2of5. For string format of the supported symbologies see
figure 3.27.
Options for code 2of5:
disable transmission of the check digit
enable check digit check
selection of the minimum number of data characters
disable space check for industrial 2of5
transmit S-Code as Interleaved 2of5
Minimum data characters:
Code 2of5 are checked for a minimum of 1, 3 or 5 characters as set by the user. If the
number of characters in the label is less than the number set, the label will be rejected.
If the fixed length option is used for a Code 2of5 type label, than such label will
additionally be checked for fixed length.
- - 41
Space check:
This option enables the reading of Industrial 2of5 labels with a large or irregular
spacing.
Transmit S-Code as Interleaved 2of5:
This option enables to transmit S-Code as Interleaved 2of5 by adding a leading zero.
Not transmit CD
Transmit CD
Not check CD
Check CD
Minimum data one
character
Minimum data three
character
Minimum data five
character
Disable space check for
Industrial 2of 5
Enable space check
for Industrial 2of 5
Not transmit S-Code as
Interleaved 2 of 5
Transmit S-Code as
Interleaved 2 of 5
- - 42
3.3.7. Options for IATA
The IATA code is a variable length symbology with an optional check digit and
non-printable start/stop characters. The following characters are supported:
the digits 0 upto 9
The checksum is calculated as the modulo seven of the data string. IATA is acronym
for International Air Transport Association. For string format see figure 3.28.
Not check CD
Check FC and SN only
Check CPN, FC and
SN
Check CPN, AC, FC and
SN
Not transmit CD
Transmit CD
3.3.8. Options for MSI/Plessey
MSI Plessey is a variable length symbology with one or two optional check digit
calculations CD1 and CD2 and non-printable start/stop characters. The following
characters are supported:
the digits 0 up to 9
The checksum is calculated as the sum modulo 10 or 11 of the data characters. The
checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and
CD1. For string format see figure 3.29.
- - 43
Options for MSI/Plessey:
disable check digit check
selection of the check digit calculation
selection of the number of check digits to be transmitted
Check digit:
If the check digit calculation is required, then the appropriate calculation method must
be selected.
Not transmit CD:
The character positions CD1 and CD2 are not transmitted.
Transmit CD1:
The character position CD2 is not transmitted.
Transmit CD1 and CD2:
All characters in the label are transmitted.
Not check CD
Check 1 CD = MOD 10
Check 2 CD's =
MOD 10/MOD 10
Check 2 CD's = MOD
10/MOD 11
Check 2 CD's =
MOD 11/MOD 10
Not transmit CD
- - 44
Transmit CD1
Transmit CD1 and CD2
3.3.9. Options for Telepen
Telepen is a variable length symbology with a check digit and non printable start/stop
characters. The following characters are supported:
in numeric mode, the digits 00 upto 99
in full ASCII mode, all 128 ASCII characters
The check digit calculation is derived from the sum of all data characters modulo 127.
The check digit cannot be transmitted. For string format see figure 3.30.
Options for Telepen:
selection of ASCII mode
Numeric mode
ASCII mode
- - 45
3.3.10. Options for UK/Plessey
UK Plessey is a variable length symbology with a mandatory checksum and non
printable start/stop characters. The following characters are supported:
the digits 0 upto 9
the characters A upto F
The checksum contains 2 digits and is calculated from the numerical values of all the
data digits. For string format see figure 3.31.
Space insertion:
This option inserts spaces in position 2, 5, 11, 14 of the data string for use in library
systems.
A to X conversion:
This option converts the character 'A' into an 'X'. The data and check digits are
affected.
Not transmit CD's
Transmit CD's
Disable space
insertion
Enable space insertion
Disable A to X
conversion
Enable A to X conversion
3.3.11. Options for Code 128 and GS1-128
Code 128:
Code 128 is a variable length symbology with a mandatory check digit and
non-printable start/stop characters. The following characters are supported:
- - 46
all 128 ASCII characters
4 non data function characters
3 start characters
4 code set selection characters
1 stop character
The check digit is calculated as the sum modulo 103 of the start character and the
weighted values of the data and special characters. For string format see figure 3.32.
Options for Code 128:
enable concatenation
GS1-128:
In this mode the Code128 data is translated to the GS1-128 format, formerly known
as EAN-128 or UCC-128. GS1-128 data starts with the FNC1 character and separates
2 data fields with the FNC1 character.
The first FNC1 character is translated to ]C1, and the second FNC1 character is
translated to an ASCII GS (hex 1D) character. For string format see figure 3.33.
Options for GS1-128:
enable GS1-128 conversion
Enable GS1-128 only:
In this mode the decoded data characters are translated to the GS1-128 format. If the
data does not comply with the GS1-128 format, then the label is rejected.
Enable GS1-128 if possible:
In this mode the decoded data characters are translated to the GS1-128 format. If the
data does not comply with the GS1-128 format, then the label is transmitted as Code
128.
- 47 -
Disable GS1-128
Enable GS1-128 only
Enable GS1-128 if
possible
Disable concatenation
Enable concatenation
3.3.12. Options for Code 93
Code 93 is a variable length symbology with 2 mandatory check digits and non
printable start/stop characters. The following characters are supported:
the digits 0 upto 9
the upper case characters A upto Z
the characters - . $ / + % SPACE
4 non printable shift characters
The first check digit (C) is the modulo 47 sum of the weighted data character values.
The second check digit (K) is the modulo 47 sum of the weighted data character
values including the first check digit (C). The check digits are not transmitted.
The special shift characters are control characters and are not transmitted with the
data. If one of these characters is followed by an upper case character 'A' upto 'Z', it is
transmitted as 1 single character. In case of an invalid combination, the label is
rejected. This method enables support for full 128 ASCII characters encodation. The
encodation is compatible with the Code 39 $, %, / and + characters. For string format
see figure 3.34.
Options for Code 93:
enable concatenation
transmission of check digits
- - 48
calculation of check digits
Concatenation:
If a Code 93 bar code contains a leading space, the data is stored into the reader's
buffer without the leading space. As soon as a Code 93 bar code is read without a
leading space, the data is appended to the reader's buffer and the entire buffer is
transmitted and cleared for new data. In case a non Code 93 bar code is read, the data
in the non-Code 93 bar code is transmitted and the buffer is cleared. The buffer size is
reader dependent. Support for this option is reader dependent.
Not check CD
Check CD
Disable
concatenation
Enable concatenation
3.3.13. Options for Code 11
Code 11 is a variable length symbology with 1 or 2 optional check digits and non
printable start/stop characters. If the data is 10 or less characters, one check digit is
used. If the data is more then 10 characters, then 2 check digits are used. The
following characters are supported:
the digits 0 upto 9
the dash character '-'
The first check digit is the modulo 11 sum of the weighted data character values. The
second check digit is the modulo 11 sum of the weighted data character values
including the first check digit. The check digits are not transmitted. For string format
see figure 3.35.
- - 49
Options for Code 11:
disable check digit(s)
automatic checking for 1 or 2 check digitsdepending of the number of data
characters
enable transmission of check digit(s)
Not check CD
Check 1 CD
Check 2 CDs
Check auto 1 or 2 CDs
Not transmit
CD(s)
Transmit CD(s)
3.3.14. Options for Korean Postal Authority code
Korean Postal Authority code is a fixed length numeric symbology with a mandatory
check digit. The check digit is not transmitted.
For string format see figure 3.36.
Options for Korean Postal Authority code:
transmit dash
not transmit dash
transmit CD
not transmit CD
Transmit dash:
The dash character '-' (hex 2D) is printed between the 3rd and 4th digit
- - 50
Not transmit CD
Transmit CD
Not transmit dash
Transmit dash
3.3.15. Options for Intelligent Mail Barcode
Intelligent Mail Barcode is a symbology in four different states. It is formerly known
as OneCode and is a variant of the 4-State Customer Barcode. The symbology is a
height modulated and has a number of fixed length s.
For string format see figure 3.37.
Fixed data capacity:
Numeric data: 20, 25 , 29 or 31 characters
Fixed data format and size:
The data is built of several identifiers which follow each other in fixed order. Sizes
are a predetermined amount of digits.
Barcode identifier: 2
Service type identifier: 3
Mailer ID and Sequence number: maybe 6+9 digits or 9+6, always totalized to
15
Delivery point zip code: may be omitted (0), standard zip (5), zip+4 (9), zip+4
incl. delivery point digits (11)
- - 51
Checksum:
An 11-bit CRC Frame Check Sequence is always calculated and is not transmitted.
Encodable characters:
digits 0 up to 9
3.3.16. Options for POSTNET
POSTNET (Postal Numeric Encoding Technique) is a height modulated symbology
with a number of fixed lengths.
For string format see figure 3.38.
Fixed data capacity:
Numeric data: 5 / 6 / 9 / 11 characters
Additional data: 1 check digit
Checkdigit:
The start and stop pattern consist of a fixed single frame bar which is not unique
inside the code. It is not transmitted. The check digit is calculated and transmitted
with the barcode data.
Encodable characters:
digits 0 up to 9
3.3.17. Options for GS1 Databar
GS1 Databar is formerly known as RSS family including the RSS-14 group. Support
for GS1 Databar options is reader dependent.
Maximum data capacity:
GS1 Databar and GS1 Databar Limited: Application Identifier "01" and 14
digits.
GS1 Databar Expanded: 74 numeric or 41 alpha characters
Checksums:
The GS1 Databar family uses a mandatory checksum.
GS1 Databar uses a modulo 79 checksum,
GS1 Databar Limited uses a modulo 89 checksum
- 52 -
GS1 Databar Expanded uses a modulo 211 checksum.
The checksum is always calculated and is not transmitted.
Encodable characters:
GS1 Databar and GS1 Databar Limited: digits 0 up to 9
GS1 Databar Expanded: subset of ISO 646: upper, lower case characters, digits,
20 punctuation characters and function character FNC1
The next GS1 Databar versions are supported
Omnidirectional/Truncated/Stacked(refer to GS1 Databar)
Limited (refer to GS1 Databar Limited)
Expanded, Expanded stacked(refer to GS1 Databar Expanded)
For string format see figure 3.39 or 3.40.
Options for GS1 Databar:
transmission of CD
transmission of Application Identifier
Not transmit CD:
Do not transmit the last character of GS1 Databar.
Not transmit CD
Transmit CD
Not transmit Application
Identifier
Transmit Application
Identifier
- - 53
3.3.18. Options for Composite Codes
CC-A is a modified MicroPDF417 version.
CC-B is standard MicroPDF417.
CC-C is standard PDF417.
Maximum data capacity:
CC-A: 56 characters
CC-B: 338 characters
CC-C: 2361 characters
Symbol size:
1D part: see RSS and EAN codes
Composite part: CC-A and CC-B same as MicroPDF417, CC-C same as PDF417
Error correction:
1D part: only error detection
Composite part: Reed Solomon error correction
Encodable characters:
ASCII values 0 - 127 ( ISO 646 )
ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII )
with ECI: many other character sets
For string format of composite codes see figure 3.41 or 3.42 or 3.43.
Options for Composite codes:
enable composite code
ignore link flag
output mode

Termékspecifikációk

Márka: Posiflex
Kategória: nincs kategorizálva
Modell: HC-1521IR

Szüksége van segítségre?

Ha segítségre van szüksége Posiflex HC-1521IR, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Posiflex

Posiflex

Posiflex PS-3616 Útmutató

10 December 2024
Posiflex

Posiflex PP-8800 Útmutató

10 December 2024
Posiflex

Posiflex TX-2300-G2 Útmutató

6 Szeptember 2024
Posiflex

Posiflex TX-1000AE Útmutató

6 Szeptember 2024
Posiflex

Posiflex TX-5500 Útmutató

6 Szeptember 2024
Posiflex

Posiflex TX-5300 Útmutató

6 Szeptember 2024
Posiflex

Posiflex TX-6000 Útmutató

6 Szeptember 2024
Posiflex

Posiflex PD-6907U Útmutató

6 Szeptember 2024
Posiflex

Posiflex PD-6607U Útmutató

5 Szeptember 2024
Posiflex

Posiflex PD-6807U Útmutató

5 Szeptember 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva