INSTRUCTION MANUAL
DP-100 Series
High-performance Digital DisplayPressure Sensor
WARNING
Thank you very much for using SUNX products. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.
٨
٨
٨
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products
which meet laws and standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or country.
Japanese Measurement Laws prohibit the use of this product in Japan.
NAMES OF EACH PART1
Connection
connector
DP-100
type: R
1
8
+ M5 female screw
DP-100-E
type: G
1
8
+ M5 female screw
DP-100-N
type:
NPT
1
8
+ M5 female screw
Pressure port
DP-100
Main display
Sub-display
Setting value
DOWN key
Setting value UP key
٨When connecting a commercial coupler to the pressure port, attach a
12mm spanner (14mm for type) to the pressure port's hexa-DP-100-E
gon section to fix the port, and then tighten with a tightening torque of
9.8Nm or less. The commercial coupler or pressure port section will be
damaged if the tightening torque is excessive.
Wrap sealing tape around the coupler when connecting to prevent leaks.
PIPING2
Standard type:
Lights up when compa-
rative
output 2 is ON
High-function type:
Lights up when analog
voltage output is set
Output 2 / analog
voltage output oper-
ation indicator
Lights up when compa-
rative output 1 is ON
Output 1 operation
indicator
Mode selection key
MJE-DP100 No.6091-00
12mm spanner
MOUNTING3
٨The sensor mounting bracket (MS-DP1-1)is available as an option.
When mounting the sensor onto the sensor mounting bracket, etc., the
tightening torque should be 1.2N m or less.
Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6mm) screws
with washers
(Accessory with MS-DP1-1)
٨The panel mounting bracket (optional) and front coverMS-DP1-2
MS-DP1-3 (optional) are also available as options.
Front cover
MS-DP1-3 (Optional)
31
31
(Unit: mm)
Panel cut-out size
Panel mounting bracket
MS-DP1-2 (Optional)
M3 (length 12mm) pan head
screw
(Accessory with MS-DP1-2)
For use outside Japan
Connection method
Disconnection method
Note: Do not pull by holding the cable without pressing the release lever, as this can
cause cable break.
٨
Insert the cable with connector CN-14A-Cغ
into this product's connection connector
section as shown in the right figure.
٨Pressing the release lever of the cable
with connector, pull out the cable.
WIRING4
Cable with connector
CN-14A-Cغ
Release lever
Ԙ ԙ Ԛ ԛ
<Connection connector pin arrangement>
Connector pin No.
Terminal name
+VԘ
Comparative output 1ԙ
Standard type: Comparative output 2
High-function type: Analog voltage output or external input
Ԛ
0Vԛ
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Standard type
Users' circuitInternal circuit
+
_12 to 24V DC
±10%
(Black)
Comparative output 1
Main circuit
(White) Comparative output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
Main circuit
High-function type
Users' circuitInternal circuit
+
_12 to 24V DC
±10%
(White)
Analog voltage output
or external input
(Black) Comparative output 1
(Blue) 0V
100mA max.
5V
1kΩ
Load
PNP output type
Standard type
Main circuit
Users' circuitInternal circuit
+
_12 to 24V DC
±10%
(Black) Comparative output 1
(White) Comparative output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
NPN output type
When using the analog voltage output, take care to the input impedance of
the connected device.
Furthermore, note that if the cable is extended, the cable resistance will
cause the voltage to drop.
I/O CIRCUIT DIAGRAMS5
High-function type
Main circuit
(Black) Comparative output 1
Users' circuitInternal circuit
+
_12 to 24V DC
±10%
(Blue) 0V
(White)
Analog voltage output
or external input
1kΩ
100mA max.
Load
(Brown)V
Color code of cable with connector
(Brown)V
Color code of cable with connector
(Brown)V
Color code of cable with connector
(Brown)V
Color code of cable with connector
OUTPUT MODE AND OUTPUT OPERATION6
Notes:1)
2
Hysteresis can be fixed in 8 steps.
Refer to < > in ' ' for setting.Hysteresis fixed value selection  PRO MODE
' ' is displayed for comparative output 1 and ' ' for comparative output 2.
10
٨ON / OFF of the comparative output is controlled in this mode.
EASY mode
H (Hysteresis)
H Hysteresis fixed (Note 1)
P
0
ON
OFF
Comparative
output
Pressure
٨
The EASY mode, hysteresis mode or window comparator mode can be
selected as the output mode for comparative output 1 and comparative
output 2.
Refer to 'Comparative output 1/2 output mode setting' in ' MENU
SETTING MODE' for details.
9
SETTING
7
<Setting procedures>
RUN MODE
This is the pressure detection state.
Refer to ' '.RUN MODE
8
MENU SETTING MODE
This is the setting mode for simple
setting.
Refer to ' '.MENU SETTING MODE
9
PRO MODE
This is the setting mode for
detailed setting.
Refer to ' PRO MODE
'.
10
Press for 2 sec.
MODE
Press for 4 sec.
MODE
10
٨The comparative output ON / OFF state can be controlled with randomly
set hysteresis in this mode.
Hysteresis mode
Lo
Hi
0
ON
OFF
Comparative
output
H (Hysteresis)
Pressure
٨I
n this mode, the ON or OFF state of the comparative output is controlled
with a pressure in the set range.
Window comparator mode
H (Hysteresis)
H Hysteresis fixed (Note 1)
H (Hysteresis)
Comparative
output
Lo
Hi
0
ON
OFF
Pressure
Note:
' ' or ' ' is displayed for comparative output 1 and ' ' or ' ' for
comparative output 2.
H: 1 digit or more
2 digits or more when
using psi unit
Notes:1)
2
Hysteresis can be fixed in 8 steps.
Refer to in ' ' for setting.< Hysteresis fixed value selection> PRO MODE
' ' or ' ' is displayed for comparative output 1 and ' ' or ' ' for
comparative output 2.
<Setting condition 4>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' '
(Window comparator mode)
Comparative output 2 output mode: ' ' (OFF)
<Setting condition 5>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' '
(Window comparator mode)
Comparative output 2 output mode: ' ' (EASY mode)
RUN MODE8
Setting the threshold value
٨
Refer to 'Comparative output 1/2 output
mode setting Analog voltage output / ' and '
external input selection' in ' MENU SET-
TING MODE' for setting conditions.
9
Standard type
<RUN mode state>
<Setting condition 1>
Comparative output 1 output mode: ' ' (EASY mode)
Comparative output 2 output mode: ' ' (OFF)
<Setting condition 3>
Comparative output 1 output mode: ' ' (EASY mode)
Comparative output 2 output mode: ' ' (Hysteresis mode) or
' '
(Window comparator mode)
<Setting condition 2>
Comparative output 1 output mode: ' ' (EASY mode)
Comparative output 2 output mode: ' ' (EASY mode)
Note: If the set pressure range is exceeded, ' ' (exceeds the upper limit) or ' '
(exceeds the lower limit) will appear on the sub-display.
' ' will also appear if the Hi side threshold value exceeds the Lo side threshold
value when setting the ' hysteresis mode / window comparator mode ' threshold value.
<RUN mode state>
<RUN mode state>
<RUN mode state>
<RUN mode state>
<Setting condition 6>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' '
(Window comparator mode)
Comparative output 2 output mode: ' ' (Hysteresis mode) or
' '
(Window comparator mode)
DP-100
Since only the sub-display changes in the threshold setting, the following
shows only the sub-display.
MODE
Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
MODE
<RUN mode state>
Automatic
Automatic
Automatic
Automatic
MODE
MODE
MODE
MODE
Automatic
Automatic
Automatic
MODE
MODE
MODE
MODE
MODE
MODE
MENU SETTING MODE9
٨
٨
٨
When the mode selection key is held down for two seconds in the
RUN mode, the menu setting mode will open.
The mode will change to the RUN mode when the mode selection key
is held down during this setting process.
The leftmost setting items are the default settings (factory settings).
Setting item Description
Comparative output 1
output mode setting Sets the output operation of comparative output 1.
Comparative output 2
output mode setting
(Standard type only)
Sets the output operation of comparative output 2.
Pressure unit can be changed.
Response time setting
Sets the response time.
The response time can be selected from 2.5ms, 5ms, 10ms, 25ms, 50ms,
100ms, 250ms, 500ms, 1,000ms or 5,000ms.
Displayed color of the
main display selection Displayed color of the main indicator can be changed.
Unit selection
N.O. / N.C. selection Normal open (N.O.) or normal close (N.C.) can be selected.
Analog voltage output /
external input selection
(High-function type
only)
Selects analog voltage output, auto-reference input, or remote zero-ad-
justment input.
Notes: 1)
2)
3)
4)
If the comparative output 2 output mode setting is set to ' ', the display of
N.O. / N.C. selection is the same as the high-function type.
The default setting of the high pressure type is ' ', and that of the low pressure type is ' '.
The default setting of the low pressure type is ' '. ' ' is not displayed.
This is not displayed on the high-pressure type.
Standard type
High-function type
(OFF mode)
<RUN mode>
<Comparative output 1 output mode setting>
<Analog voltage output / external input selection>
<Comparative output 2 output mode setting> (Note 1)
(EASY mode)
(2.5ms) (5ms) (5,000ms)
MODE
MODE
MODE
(N.O.) (N.C.)
<N.O. / N.C. selection> (Note 2)
MODE
MODE
࡮࡮࡮࡮࡮
࡮࡮࡮࡮࡮
࡮࡮࡮࡮࡮
࡮࡮࡮࡮࡮࡮࡮࡮࡮࡮
MODE
<RUN mode>
 MPa (Note 3) (kPa) (bar)
(mmHg)
(inchHg)(Note 4) (psi)
(kgf/cm2)
<Response time setting>
<Display color of the main display selection>
Hysteresis
mode
Window
comparator
mode
Analog
voltage
output
Remote
zero-adjust-
ment input
(EASY mode)
Hysteresis
mode
<N.O. / N.C. selection> (Note 1) (Note 2)
Output 1: N.O.
Output 2: N.O.
Output 1: N.C.
Output 2: N.O.
Output 1: N.O.
Output 2: N.C.
Output 1: N.C.
Output 2: N.C.
Window
comparator
mode
Standard type
High-function type
Press for 2 sec.
MODE
Red when ON
Green when OFF
Red when ON
Green when OFF
(Always red)
(Always green)
Auto-refer-
ence input
High-function type
Common
<Setting condition 7>
Comparative output 1 output mode: ' ' (EASY mode)
Analog voltage output / external input selection: ' ' (Analog voltage output)
<RUN mode state>
<Setting condition 9>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' ' (Window comparator mode)
Analog voltage output / external input selection: ' ' (Analog voltage output)
٨The zero-adjustment function forcibly sets the pressure to 'zero' when
the pressure port is opened.
Zero-adjustment function
٨The key lock function prevents key operations so that the conditions set
in each setting mode are not inadvertently changed.
Key lock function
<Key lock set>
<Key lock released>
Hold
down
Hold
down
Hold
down
(Key lock set)
MODE
(Key lock released)
٨
٨
The peak / bottom hold functions display the peak value and bottom val-
ue of the fluctuating pressure.
The peak value is displayed on the main display and the bottom value is
displayed on the sub-display.
Peak / bottom hold function
MODE
Hold
down
<Setting condition 8>
Comparative output 1 output mode: ' ' (EASY mode)
Analog voltage output / external input selection: ' ' (Auto-reference input) or
' '
(Remote zero-adjustment input)
<Setting condition 10>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' ' (Window comparator mode)
Analog voltage output / external input selection: ' ' (Auto-reference input) or
' '
(Remote zero-adjustment input)
Note: Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to ' ' and ' AUTO-REFERENCE FUNCTION REMOTE
ZERO-ADJUSTMENT FUNCTION '.
12 13
Automatic
Automatic
Automatic
<RUN mode state>
Automatic
Automatic
MODE
<RUN mode state>
(Note)
Automatic
MODE
Blinks alternately
<RUN mode state>
(Note)
Automatic
Automatic
MODE
MODE
MODE
MODE
Blinks alternately
Blinks alternately

Termékspecifikációk

Márka: Panasonic
Kategória: nincs kategorizálva
Modell: DP-102

Szüksége van segítségre?

Ha segítségre van szüksége Panasonic DP-102, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Panasonic

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva