Oldal 1/14
SPLIT-TYPE AIR CONDITIONERS
OPERATING INSTRUCTIONS
INDOOR UNIT
MS-GA50VB
MS-GA60VB
MS-GA80VB
MSH-GA50VB
MSH-GA60VB
MSH-GA71VB
MSH-GA80VB
For customers
Thank you very much for purchasing this Mitsubishi room air conditioner.
•
To use this unit correctly and safely, be sure to read this operating instructions
before use. Keep this manual carefully for later reference.
•
Be sure to receive a guarantee card from your dealer and check that the
purchased date
and shop name, etc. are entered correctly.
• This air conditioner should not be installed by the customer.
(Safety and performance functions cannot be assured.)
2
AIR OUTLET
• This air conditioner is NOT intended for use by children or infirm persons without supervisions.
Do not use intermediate connection of the power supply cord or the extension cord and do not
connect many devices to one AC outlet.
•
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Remove dirt from the power supply plug and securely insert the plug into the outlet.
• If dirt adheres to the plug or insertion is incomplete, it may cause a fire or an electric shock.
Do not scratch or process the power supply cord, etc.
• Do not put heavy object on the power supply cord and do not scratch or process the cord. The cord may
be damaged and this may cause a fire or an electric shock.
Do not turn the breaker off/on and/or disconnect/connect the power supply plug during operation.
• This may cause a fire due to spark, etc.
• Be sure to turn off the breaker and/or disconnect the power supply plug absolutely after switching the
indoor unit off with the remote controller.
Do not expose your skin directly to cool air for a long time.
• This could damage your health.
Installation, repairs or relocation should not be done by the customer.
• If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc. Consult your dealer.
• If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order
to avoid a hazard.
Do not insert your finger or a stick, etc. into the air inlet/outlet.
• Since the fan rotates at high speed, this may cause an injury.
• Young children should be supervised to ensure that they do not play with the air conditioner.
When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power
supply plug and/or turn off the breaker.
• If the unit continues to be operated in an abnormal condition, it may cause a fire, trouble, etc. In this case,
consult your dealer.
WARNING
CONTENTS
SAFETY PRECAUTIONS ............................................................................................................................................................2
NAME OF EACH PART ...............................................................................................................................................................3
PREPARATION BEFORE OPERATION .....................................................................................................................................4
I FEEL... AUTO OPERATION ......................................................................................................................................................6
MANUAL OPERATION (COOL, DRY, HEAT/FAN) ......................................................................................................................7
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT ..........................................................................................................7
LONG OPERATION ....................................................................................................................................................................8
ECONO COOL OPERATION ......................................................................................................................................................8
TIMER OPERATION (ON/OFF TIMER) ......................................................................................................................................8
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME ...............................................................9
MAINTENANCE ..........................................................................................................................................................................9
CLEANING THE AIR FILTER (CATECHIN) ..............................................................................................................................10
REPLACEMENT OF THE AIR CLEANING FILTER .................................................................................................................10
BEFORE CONTACTING THE SERVICE REPRESENTATIVE, CHECK THE FOLLOWING AGAIN ........................................11
WHEN YOU THINK THAT TROUBLE HAS OCCURRED .........................................................................................................11
INSTALLATION, RELOCATION AND INSPECTION .................................................................................................................12
SAFETY PRECAUTIONS
• Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these
“Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to observe them.
• Stop using the air conditioner and consult your dealer in case any trouble or abnormality occurs.
Marks and their meanings
WARNING: Incorrect handling could cause a serious hazard, such as death, serious injury, etc. with a high
probability.
CAUTION: Incorrect handling could cause a serious hazard depending on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your finger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
• After reading this manual, keep it together with the installation manual in a handy place for easy reference.
Warning positions
FRONT PANEL
ENCLOSURE
When the air filter is to be removed, do not touch the metal part of the indoor unit.
• This may cause an injury.
Do not touch the air inlet or aluminum fin of the outdoor unit.
• This may cause an injury.
Do not put a vase or glass on the indoor unit.
• Water dropping into the indoor unit may deteriorate the insulation, causing electric shock.
Do not use an insecticide or flammable spray.
• This may cause a fire or deformation of the cabinet.
Do not put a pet or houseplant where it will be exposed to direct airflow.
• This could injure the pet or plant.
Do not place other electric appliances or furniture under the indoor/outdoor unit.
• Water may drip down from the unit, and this may cause damage or malfunction to them.
Do not leave the unit on an installation stand which is damaged.
• The unit may fall and this may cause an injury.
Do not step onto an unstable bench when maintaining the unit, etc.
• This may cause an injury, etc. if you fall down.
Do not pull the power supply cord.
• The core wire of the power supply cord may be disconnected and this may cause a fire.
Do not charge or disassemble the batteries and do not throw them into a fire.
• This may result in leakage, fire or an explosion.
Do not operate the unit for a long time in high humidity, e.g. leaving a door or window open.
• In the cooling mode, if the unit is operated in a room with high humidity (80% RH or more) for a long time,
water condensed in the air conditioner may drop and wet or damage furniture, etc.
CAUTION
ENCLOSURE
3
MU-GA60VB
MUH-GA60VB
MUH-GA71VB
MU-GA80VB
MUH-GA80VB
MU-GA50VB
MUH-GA50VB
Operation Indicator
SAFETY PRECAUTIONS
For installation
Do not use the unit for special purposes.
• Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects.
This may cause deterioration of quality, etc.
Do not put a stove, etc. where they are exposed to direct airflow.
• This may cause imperfect combustion.
When the unit is to be cleaned, switch it off and disconnect the power supply plug and/or turn off
the breaker.
• Since the fan rotates at high speed during operation, this may cause an injury.
When the unit is not going to be used for a long time, disconnect the power supply plug and/or turn
off the breaker.
• Otherwise, dirt may collect and this may cause a fire.
Replace the 2 batteries of the remote controller with new ones of same type.
• Using an old battery together with a new one may result in heat generation, leakage or an explosion.
If liquid from the batteries gets onto your skin or clothes, wash it well with clean water.
•
If liquid from the batteries gets into your eyes, wash them well with clean water and consult a doctor at once.
Ventilate well in using the unit with a stove, etc.
• An oxygen shortage may occur.
Do not operate switches with wet hands.
• This may cause an electric shock.
Do not clean the air conditioner with water or put a vase or glass on it.
• Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not step or put anything on the indoor/outdoor unit.
• This may cause an injury, etc. if you or something falls down.
CAUTION
Earth the unit.
• Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing
is incorrect, it may cause an electric shock.
Install an earth leakage breaker depending on the place where the air conditioner is to be installed
(humid places, etc.).
• If the earth leakage breaker is not installed, it may cause an electric shock.
Drain should be fully drained.
•
If the drainage route is incomplete, water may drop from the unit. This may wet and damage the furniture.
CAUTION
WARNING
• Consult your dealer or contractor for installation of the air conditioner. Since special techniques and work are
required, installation should not be done by the customer. If this is done incorrecty, it may cause a fire, an electric
shock, injury or water leaking.
• Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
NAME OF EACH PART
Indoor unit
Outdoor unit
Emergency operation switch
Remote control
receiving section
Piping
Air outlet
Drain outlet
Air cleaning filter
(White bellows type)
Vertical vane
Operation section
(When the front panel is opened)
Display section
Horizontal vane
Air inlet (back and side)
Drainage hose
Operation Indicator lamp
Air filter (Catechin)
Front panel
Air inlet
Power supply cord
Remote control
receiving section
Remote controller
Power supply plug
Termékspecifikációk
Márka: | Mitsubishi |
Kategória: | Airco |
Modell: | MSH-GA60VB |
Szüksége van segítségre?
Ha segítségre van szüksége Mitsubishi MSH-GA60VB, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Airco Mitsubishi
14 Október 2024
9 Október 2024
9 Október 2024
8 Október 2024
4 Október 2024
2 Október 2024
1 Október 2024
30 Szeptember 2024
29 Szeptember 2024
23 Szeptember 2024
Útmutatók Airco
- Airco Mestic
- Airco Samsung
- Airco Beko
- Airco Fujitsu
- Airco Dometic
- Airco Electrolux
- Airco Whirlpool
- Airco Nedis
- Airco LG
- Airco Grundig
- Airco Ariston Thermo
- Airco Candy
- Airco Gorenje
- Airco Princess
- Airco Oregon Scientific
- Airco Bosch
- Airco NewAir
- Airco Panasonic
- Airco MPM
- Airco AEG
- Airco Emerio
- Airco Sharp
- Airco Einhell
- Airco Toshiba
- Airco Ozito
- Airco Hyundai
- Airco Hisense
- Airco HQ
- Airco Siemens
- Airco Medion
- Airco Exquisit
- Airco Corbero
- Airco Camry
- Airco TCL
- Airco Danby
- Airco DeLonghi
- Airco Insignia
- Airco Heinner
- Airco Infiniton
- Airco Wilfa
- Airco Klarstein
- Airco VOX
- Airco Be Cool
- Airco Tripp Lite
- Airco Vivax
- Airco Thomson
- Airco Fuave
- Airco Ardes
- Airco Orima
- Airco Eden
- Airco Bimar
- Airco Clatronic
- Airco Bomann
- Airco Amana
- Airco Hotpoint
- Airco Haier
- Airco Frigidaire
- Airco Cecotec
- Airco Sencor
- Airco Qlima
- Airco Baxi
- Airco Innoliving
- Airco Avidsen
- Airco Rowenta
- Airco Westinghouse
- Airco Hitachi
- Airco BLUEPALM
- Airco Telefunken
- Airco GoldAir
- Airco Domo
- Airco Russell Hobbs
- Airco SHE
- Airco Create
- Airco Black & Decker
- Airco Wood's
- Airco Vaillant
- Airco Livington
- Airco Orbegozo
- Airco Daewoo
- Airco Livoo
- Airco ARGO
- Airco GE
- Airco Guzzanti
- Airco Concept
- Airco Whynter
- Airco SVAN
- Airco Keystone
- Airco Consul
- Airco TriStar
- Airco Suntec
- Airco APC
- Airco Daizuki
- Airco Daikin
- Airco Midea
- Airco Electroline
- Airco Kogan
- Airco Profilo
- Airco Honeywell
- Airco Truma
- Airco Stirling
- Airco Furrion
- Airco Dimplex
- Airco Master
- Airco Aspes
- Airco Kenmore
- Airco Thermex
- Airco Trotec
- Airco Manta
- Airco Blaupunkt
- Airco HTW
- Airco Korona
- Airco Comfee
- Airco Be Quiet!
- Airco Finlux
- Airco Gree
- Airco AKAI
- Airco Emerson
- Airco Kalorik
- Airco Sanyo
- Airco Philco
- Airco ECG
- Airco Esatto
- Airco Element
- Airco Friedrich
- Airco Rinnai
- Airco Argoclima
- Airco RCA
- Airco SereneLife
- Airco Carrier
- Airco Becken
- Airco OneConcept
- Airco Olimpia Splendid
- Airco ActronAir
- Airco Mistral
- Airco Orava
- Airco Eurom
- Airco Sauber
- Airco IFB
- Airco Sonnenkönig
- Airco Tectro
- Airco Zibro
- Airco Airwell
- Airco Amcor
- Airco Calor
- Airco Mabe
- Airco Anslut
- Airco Termozeta
- Airco Eldom
- Airco Jocca
- Airco Nabo
- Airco White Knight
- Airco Profile
- Airco Evolar
- Airco Elba
- Airco Proline
- Airco Royal Sovereign
- Airco Kelvinator
- Airco Everglades
- Airco Heylo
- Airco ElectriQ
- Airco Daitsu
- Airco Milectric
- Airco Saunier Duval
- Airco Duux
- Airco Alpatec
- Airco Primo
- Airco Godrej
- Airco Maiko
- Airco Waeco
- Airco Essentiel B
- Airco Team
- Airco Edgestar
- Airco Maxicool
- Airco KDK
- Airco Carrefour Home
- Airco Equator
- Airco Kunft
- Airco Proklima
- Airco Home Electric
- Airco Eco-De
- Airco REMKO
- Airco Just Fire
- Airco Teco
- Airco Chigo
- Airco Hokkaido
- Airco Gutfels
- Airco Holland Electro
- Airco Elgin
- Airco Fronius
- Airco D-Let
- Airco Braemar
- Airco Klimaire
- Airco Duracraft
- Airco SEEGER
- Airco Khind
- Airco LERAN
- Airco General Electric
- Airco SPT
- Airco Fuji Electric
- Airco Polocool
- Airco Convair
- Airco Fral
- Airco Prem-i-air
- Airco Arcoaire
- Airco Bodin
- Airco MRCOOL
- Airco Monzana
- Airco Trilec
- Airco Kaden
- Airco TURBRO
- Airco Bonaire
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Big Ass Fans
- Airco Artrom
- Airco Commercial Cool
- Airco Riffel
- Airco Heat Controller
- Airco Luma Comfort
- Airco Norpole
- Airco Kaco
- Airco Omega Altise
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco KuulAire
- Airco Cool-Space
- Airco Aconatic
- Airco AireMax
- Airco VänEE
- Airco Mayer
- Airco Perfect Aire
- Airco Koldfront
Legújabb útmutatók Airco
16 Október 2024
16 Október 2024
16 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024
15 Október 2024