Használati útmutató Midea MPPF-09CRN1

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Midea MPPF-09CRN1 (20 oldal) a légkondicionáló kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/20
PORTABLE AIR CONDITIONER(Local Air Conditioner)
Owner’s Manual &
Installation Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Safety Precautions
. ...........................................................................................................................................................
Safety Precautions
Installation Instructions
Operating Instructions
Maintenance
Table of Contents
Control Panel Features......................................................................................................................................................
Operation Instructions......................................................................................................................................................
Other features......................................................................................................................................................................
Safety Precautions..............................................................................................................................................................
Air Filter Cleaning ..............................................................................................................................................................
Troubleshooting Tips .......................................................................................................................................................
Unit Cleaning ......................................................................................................................................................................
Store the unit when not in use .....................................................................................................................................
Preparation............................................................................................................................................................................
Design Notice.......................................................................................................................................................................
Ambient Temperature Range For Unit Operating..................................................................................................
Exhaust Hose Installation.................................................................................................................................................
Choosing The Right Location.........................................................................................................................................
Tools Needed.......................................................................................................................................................................
Accessories............................................................................................................................................................................
Window Installation Kit.....................................................................................................................................................
Installation..............................................................................................................................................................................
Troubleshooting Tips
03
Energy Rating Information ............................................................................................................................................. 07
10
12
13
14
06
06
06
07
08
06
08
09
15
16
16
16
17
Safety
Precautions
Safety
Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage, the
following instructions must be followed. Incorrect operation due to ignoring of
instructions may cause death, harm or damage.
WARNING
Safety Precautions
Do not operate a unit that it has been dropped or damaged.
The appliance with electric heater shall have at least 1 meter space to the combustible
materials.
Do not touch the unit with wet or damp hands or when barefoot.
If the air conditioner is knocked over during use, turn off the unit and unplug it from the main
power supply immediately. Visually inspect the unit to ensure there is no damage. If you
suspect the unit has been damaged, contact a technician or customer service for assistance.
Page 3
WARNING
This symbol indicates the possibility of
personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of
property damage or serious consequences.
Installation must be performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock, or fire.
Use only the included accessories and parts, and specified tools for the installation. Using non-
standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
Make sure that the outlet you are using is grounded and has the appropriate voltage.
The power cord is equipped with a three-prong grounding plug to protect against shock.
Voltage information can be found on the nameplate of the unit.
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker
(the fuse or circuit breaker needed is determined by the maximum current of the unit. The
maximum current is indicated on the nameplate located on unit), have a qualified electrician
install the proper receptacle.
Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive
noise and vibration.
The unit must be kept free from obstruction to ensure proper function and to mitigate safety
hazards.
Do not modify the length of the power cord or use an extension cord to power the unit.
Do not share a single outlet with other electrical appliances. Improper power supply can
cause fire or electrical shock.
Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
Do not install the unit in a location that may be exposed to combustible gas, as this could
cause fire.
The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to
roll over objects, as these could cause tipping.
Safety
Precautions
Page 4
In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
Your air conditioner should be used in such a way that it is protected from moisture.
e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can
fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
All wiring must be performed strictly in accordance with the wiring diagram located inside of
the unit.
The unit's circuit board(PCB) is designed with a fuse to provide overcurrent protection. The
specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
When the water drainage function is not in use, keep the upper and the lower drain plug firmly
to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent
children from choking.
This appliance can be used by children aged from 8 years and above and person with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision. (be applicable for the European Countries)
This appliance is not intended for use by persons (including childern) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
Children must be supervised around the unit at all times.(be applicable for other countries
except the European Countries )
If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
CAUTION
Do not use this product for functions other than those described in this instruction manual.
Before cleaning, turn off the power and unplug the unit.
Prior to cleaning or other maintenance, the appliance must be disconnected from the supply
mains.
Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has
been dropped or damaged.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar
coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area
and where it will not be tripped over.
Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Discard unit or
return to an authorized service facility for examination and/or repair.
To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control
device.
The appliance shall be installed in accordance with national wiring regulations.
Contact the authorised service technician for repair or maintenance of this unit.
Contact the authorised installer for installation of this unit.
Do not cover or obstruct the inlet or outlet grilles.
Safety
Precautions
Page 5
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
1.
Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific
information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated
greenhouse gas(on some models), please refer to the relevant label on the unit itself.
2.
Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
3.
Product uninstallation and recycling must be performed by a certified technician.
Sociable Remark
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
When using this dehumidifier in the European countries, the following information
must be followed:
· The municipality has established collection systems, where electronic waste can be disposed
of at least free of charge to the user.
· When buying a new product, the retailer will take back the old product at least free of charge.
· The manufacture will take back the old appliance for disposal at least free of charge to the user.
· As old products contain valuable resources, they can be sold to scrap metal dealers. Wild
disposal of waste in forests and landscapes endangers your health when hazar do us
substances leak into the ground-water and find their way into the food chain.
Disconnect the power if strange sounds, smell, or smoke comes from it.
Do not press the buttons on the control panel with anything other than your fingers.
Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has
been dropped or damaged.
Do not operate or stop the unit by inserting or pulling out the power cord plug.
Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit
in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc.
Always transport your air conditioner in a vertical position and stand on a stable, level surface
during use.
Always contact a qualified person to carry out repairs. If the damaged power supply cord must
be replaced with a new power supply cord obtained from the product manufacturer and not
repaired.
Hold the plug by the head of the power plug when taking it out.
Turn off the product when not in use.
Installation Instructions
Page 6
Preparation
CThe unit can be controlled by the unit control panel alone or with the remote
controller. This manual does not include Remote Controller Operations, see the <<Remote Controller
Instruction>> packed with the unit for details.
MODE Temperature Range MODE Temperature Range
Design Notice
Ambient Temperature Range For Unit Operating
In order to ensure the optimal performance of our products, the design specifications of the unit
and remote control are subject to change without prior notice.
Cool 17-35°C (62-95°F)
Dry
Heat(pump heat
mode)
Heat(electrical
heat mode)
13-35°C (55-95°F)
5-30°C (41-86°F)
rear
front
control panel
horizontal louver
blade
Caster
handle
(both sides)
power plug socket
power cord buckle
bottom tray
drain outlet
power cord outlet
drain outlet
(only for pump
heating mode)
upper air filter
upper air intake
air outlet
lower air filter
lower air intake
drain outlet
30°C (86°F)
Exhaust hose installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For
COOL,HEAT(heat pump type) or AUTO mode must be installed exhaust hose. For FAN, DRY or HEAT
(electrical heat type) mode must be removed exhaust hose.
Installation
Instructions
Page 7
50cm
50cm
19.7inch
50cm
19.7inch
19.7inch
Installation
Instructions
Choosing The Right Location
Recommend Installation
Your installation location should meet the following requirements:
-Make sure that you install your unit on an even surface to minimize noise and
vibration.
-The unit must be installed near a grounded plug, and the Collection Tray Drain
(found on the back of the unit) must be accessible.
-The unit should be located at least 30cm (12”) from the nearest wall to ensure
proper air conditioning. The horizontal louver blade should be at least 50cm
(19.7”) away from obstacles.
-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this
could cause damage to the unit.
50cm
19.7 inch
Energy Rating Information
How to Stay Cool with a New Portable Air Conditioner(For the models comply with the
requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may notice that the
cooling capacity claims on portable air conditioner packaging are significantly lower than that of
models produced prior to 2017. This is due to changes in the test procedure, not to the portable
air conditioners themselves.
What should I look for first when purchasing a portable air conditioner?
The right air conditioner helps you cool a room efficiently. An undersized unit won't cool adequately
while one that's too large will not remove enough humidity, leaving the air feeling damp. To find
the proper air conditioner, determine the square footage of the room you want to cool by
multiplying the room length by its width. You also need to know the air conditioner's BTU (British
Thermal Unit) rating, which indicates the amount of heat it can remove from a room. A higher
The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts(Diameter:150mm, Length:1.5m
+ Diameter: 130mm, Length: 1.5m) The Energy rating and noise information for unit with 3 meters extended .
exhaust duct is not assessed.(For some models)
NOTE
We recommend that operating the unit at room temperature below 35
°C
. Since there is a risk that the unit with 3
meters extended exhaust duct would not work at room temperature above 35
°C
under some extreme conditions,
such as the lower air intake be blocked for 50%.
The energy rating and noise information for this unit is based on the standard installation using an un-extended
exhaust duct (Diameter:150mm, Length:1.5m) without window slider adaptor or wall exhaust adaptor A.
Page 9
Window Installation Kit
Or
Unit adaptor Window slider
adaptor
Exhaust hose
Exhaust hose
assembly
Hook Hole Seat
Lower groove
adaptor Make sure the adaptor
is inserted into the lower
groove of the air outlet.
Step Two: Install the Exhaust hose assembly to
the unit
Insert unit adaptor of the Exhaust hose assembly
into the lower groove of the air outlet of the unit
while the hook of the adaptor is aligned with the
hole seat of the air outlet and slide down the
Exhaust hose assembly along the arrow direction
for installation.
Installation
Instructions
Type window installation Type wall installation
Type window installation Type wall installation
Exhaust hose assembly
Unit adaptor Wall exhaust adaptor A
Exhaust hose
Press the exhaust hose(or extended exhaust hose)
into the window slider adaptor(or wall exhaust
adaptor) and unit adaptor, clamp automatically by
elastic buckles of the adaptors.
Step One: Preparing the Exhaust Hose assembly
Exhaust hoseExtended Exhaust hose
Exhaust hose assembly
Exhaust hoseExtended Exhaust hose
Exhaust hose assembly
Other Regions
Name of Accessories Qty.
Shape Name of Accessories Qty.
Shape
1 pc(*)Window Slider A Bolt
1 pc 1 set(*)Unit Adaptor Security Bracket and 2 Screws
1 pc 1 pcExhaust Hose Drain Hose
1 pc(*) 1 pcWindow Slider Adaptor Power Cord Buckle
ON /OFF
TEM P
SHO R T CUT
TIME R ON
TIME R
OFF
MO DE
FAN
SLE EP SW ING LED
1 set(*)1 pc(*)Window Slider B Remote Controller and Battery
(only for remote control models)
1 pc(*)
Wall Exhaust Adaptor A
(only for wall installation models)
2 pc(*)Foam Seal A (Adhesive)
1 pc(*)
Wall Exhaust Adaptor B(with cap)
(only for wall installation models)
2 pc(*)Foam Seal B (Adhesive)
4 set(*)
Screw and anchor
(only for wall installation models)
1 pc(*)Foam Seal C (Non-adhesive)
1 pc(*)
Drain Hose Adaptor
(only for heat pump mode)
1 pc(*)
1 pc(*)
1 pc(*)
Exhuast Hose Adaptor
Extended Exhuast Hose
Page 10
Installation
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of
the following two installation methods.
Installation
Instructions
Step Three: Preparing the Adjustable Window
Slider
1. Depending on the size of your window, adjust
the size of the window slider.
2. If the length of the window requires two or three
window sliders, use the bolt(s) to fasten the
window sliders once they are adjusted to the
proper length.
or
Window slider A
MODEL A MODEL B
Window slider B
Bolt
Window slider A Window slider B
Bolt
MODEL A Window slider A Window slider B Window slider C
Bolts
Or
Or
Or
Foam seal B
(Adhesive type-shorter)
Foam seal A
(Adhesive type)
Window
slider A
Window slider
B(if required)
Foam seal C
(Non-adhesive type)
Type 1: Hung Window or Sliding Window Installation(For some models)
1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash
and frame as shown.
3. Cut the non-adhesive foam seal C strip to match the width(or height) of the window. Insert the seal
between the glass and the window frame to prevent air and insects from getting into the room.
2. Insert the window slider assembly into the window opening.
Foam seal B
(Adhesive type-shorter)
Foam seal A
(Adhesive type)
Window slider A
Window slider B
(if required)
Foam seal C
(Non-adhesive type)

Termékspecifikációk

Márka: Midea
Kategória: légkondicionáló
Modell: MPPF-09CRN1

Szüksége van segítségre?

Ha segítségre van szüksége Midea MPPF-09CRN1, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók légkondicionáló Midea

Útmutatók légkondicionáló