Használati útmutató Lucide Limba 27877/06/30

Lucide nincs kategorizálva Limba 27877/06/30

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Lucide Limba 27877/06/30 (7 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/7
Item number: 27877/06/30
Technical details
Materials used:
Aluminium body with pc
Color:
Black
Dimmable and how is fixture dimmable
No
Size: Height: 200mm
Length: 160mm
Width: 56mm
Net weight: 0.9kg
Power requirements: 220 240V/~- 50Hz
Bulb type and maximum wattage:
6W LED
Number of bulbs:
42xLED 2835 SMD
IP degree: IP54
Infrared Sensor Instruction
This is an automatic sensor switch which can identify day and night. It uses infrared detection, IC and SMD technology: when
someone enters the detecting area the infrared detector turns on the lamp. After having left the detection area, the lamp will turn off
automatically.
Function
1. Adopts 8-bit DIP switch:
·You can select for functioning
in ambient light below 10lux (nighttime) or in any light;
·Adjustable sensitivity;
·Choose working time delay of the device: -
5s, 30s, 1Min, 3Min, 5Min, 8Min.
2.The time that the device works, can be delayed automatically:
- it re computes the time after the last detection;
3. infrared detector and sensitization resistor;
4.Simple structure and convenient use.
Specifications:
Power source: 220240V/AC,50Hz
Rated load: 800W Max.tungsten
200W Max.fluorescent
Detection angle: 100°
Detection range: 8m (22°C)
Time setting: 5s30s1Min3 Min 5 Min、 、8 Min (adjustable)
Light-control: <10LUX~2000LUX(adjustable)
Working humidity: 93%RH
Working temperature: -10°C ~+40°C
Dip switch setting
1 Working light ( )selecting (daylight switch):
·when not put to ON, it can work in any light degree
(regardless of ambient light level)
·when slide to ON, it can only work at night (<10LUX).
2. Sensitivity ( ) selecting:
·when not put to ON, High sensitivity;
·when slide to ON, Low sensitivity.
3. Time-delay (5"30"1' 5' 8')3', ,
for selection of a certain time delay, slide to ON position.-
Attention
·The installation person should be an electrician or someone with sufficient experience.
·Be sure not to install the device in a place where is full sunshine, nor obvious temperature change, for example air conditioning,
heating and air circulation
·
No obstruction or moving object should be in front of the sensor to avoid influencing the detection features.
ON
ON

Termékspecifikációk