OVERVIEW
Wireless Commercial Keypads are security keypads and should be programmed to ONE operator.
The Wireless Commercial Keypad comes with one 9V Lithium battery, instructions, and two keys. A wireless signal is
transmitted when a valid 4-digit PIN and the # key is pressed. A long tone will sound. The keypad backlight will illuminate for
15 seconds when any key is pressed. If an invalid PIN or partial PIN is accidentally entered, an error tone will sound. The
Wireless Commercial Keypad is compatible with the brands of commercial door and gate operators listed in the table below.
Wireless Commercial Keypad
Models KPW5 and KPW250
MODEL FREQUENCY AND ENCRYPTION PIN CAPACITY
KPW5 LiftMaster Security+ 2.0®Up to 5 permanent PINs and
Up to 10 unique temporary PINs
KPW250 LiftMaster Security+ 2.0® Up to 250 permanent PINs and
Up to 10 unique temporary PINs
LiftMaster Security+® 315 MHz
LiftMaster Security+® 390 MHz
Linear Multi-Code 300 MHz
Specifications
Power ..................................................................................................................................................................... 9V Lithium battery
Operating temperature range ..............................................................................................................-4°F to 140°F (-20°C to 60°C)
Storage and shipping temperature range .........................................................................................-40°F to 140°F (-40°C to 60°C)
Enclosure .............................................................................................................................................................................. NEMA 3R
2
INSTALLATION
1. Choose a mounting location suitable for your application such as a wall, flat surface, or a pedestal with a 3" x 3" mounting
pattern (LiftMaster gooseneck pedestal post models PED42 or PED64). Locate the keypad at least 6 feet (1.8 m) away
from any moving part of the gate and where the user cannot reach over, under, around or through the gate to operate the
controls. The mounting location needs to be in line of sight of the moving gate.
2. Unlock and remove the faceplate from the mounting plate.
3. Mount the mounting plate to the desired surface and secure with 1/4" screws or bolts (not provided).
4. Remove the battery cover using a Phillips screw driver. If the battery (provided) is packaged outside of the keypad, install
it and ensure it is connected. If it is installed within the keypad, connect it. Re-install inner cover.
5. Reattach the faceplate to the mounting plate and lock with the key.
To prevent possible SERIOUS INJURY or DEATH from a moving gate or door:
User activation controls MUST be located at least 6 feet (1.8 m) away from ANY moving part of the gate and where the
user cannot reach over, under, around or through the gate to operate the controls.
ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with remote controls.
Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
ALWAYS keep gate or door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.
Battery
Mounting plate
Faceplate
Battery Cover
WARNING: This product can expose you to chemicals including lead, which are known
to the State of California to cause cancer or birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.
3
Program to LiftMaster Operator
NOTE: The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic Programming.
KPW5 - The frequency and encryption are set at the factory. Proceed to Step 4.
KPW250 - The frequency and encryption are set at the factory for operators. LiftMaster Security+ 2.0 Proceed to Step 4.
For LiftMaster Security+ (315 MHz or 390 MHz), the frequency and encryption need to be set.Proceed to Step 1.
1. Enter program mode: * (Master Code) #.
2 Set frequency and encryption (KPW250 only):
LiftMaster Security+ 315 MHz - Press . A long tone will sound.03 # 2 #
LiftMaster Security+ 390 MHz - Press . A long tone will sound.03 # 3 #
To reset factory default - Press . A long tone will sound.03 # 1 #
3. Exit Program Mode: * * #.
4. Press the Learn Button on the operator.
5. Within 30 seconds - Enter a valid then press #. A long tone will sound.4-digit PIN
PROGRAM TO OPERATOR
BASIC PROGRAMMING
The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps below unless
otherwise indicated. The keypad backlight will remain on if the product is in programming mode. While in programming
mode, if an invalid code is entered, an error tone will sound, but the keypad will remain in programming mode. After 60
seconds of inactivity, the keypad will exit the programming mode. The 6-digit Master Code is used to prevent unauthorized
access to the system. A Master Code is required (factory default code: 888888) to operate the Wireless Commercial Keypad. It
is highly recommended to change and record your unique Master Code.
Programming Step Keystroke Combination Indicator
1. Enter program mode * (Master Code) # Long tone
2. Update Master Code 09 # (New 6-digit Code) # (New 6-digit Code) # Long tone
3. Exit Program Mode * *
#Keypad backlight will turn off
Programming Step Keystroke Combination Indicator
1. Enter program mode * (Master Code) # Long tone
2. Set new pin 01 # (New 4-digit PIN) # Repeat (new 4-digit PIN) #Long tone
3. Exit Program Mode * *
#Keypad backlight will turn off
NOTE: An error tone will sound if the maximum number of PINs is exceeded or if user tries to program a PIN already
programmed in the memory.
Set Master Code
Program a PIN

Termékspecifikációk

Márka: LiftMaster
Kategória: nincs kategorizálva
Modell: KPW5

Szüksége van segítségre?

Ha segítségre van szüksége LiftMaster KPW5, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva LiftMaster

LiftMaster

LiftMaster BG770 Útmutató

2 Szeptember 2024
LiftMaster

LiftMaster LMHNTG Útmutató

2 Szeptember 2024
LiftMaster

LiftMaster SL585 Útmutató

1 Szeptember 2024
LiftMaster

LiftMaster SL590 Útmutató

1 Szeptember 2024
LiftMaster

LiftMaster BG3000 Útmutató

1 Szeptember 2024
LiftMaster

LiftMaster BG790 Útmutató

1 Szeptember 2024
LiftMaster

LiftMaster 64LM Útmutató

1 Szeptember 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

MOZA

MOZA SR-P Útmutató

10 Április 2025
CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025