Használati útmutató LG LW1222ERSM

Olvassa el alább 📖 a magyar nyelvű használati útmutatót LG LW1222ERSM (31 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 6 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/31
www.lg.com
EN ENGLISH
*MFL71860111*
Copyright © 2021 LG Electronics Inc. All Rights Reserved
MFL71860 111
Rev.00_120621
AIR CO NERNDITIO
Read this owners manual thoroughly before operating the appliance
and keep it handy for reference at all times.
OWNER’S MANUAL
TYPE : WINDOW
LW1022ERSM
LW1222ERSM
TABLE OF CONTENTS
SAFETY INSTRUCTIONS 3 ..............................................................
IMPORTANT SAFETY INSTRUCTIONS 4 ..........................................................
PRODUCT OVERVIEW 8 ..................................................................
Exterior Parts 8 ....................................................................................................
Interior Parts......................................................................................................8
INSTALLATION 9 ...............................................................................
Electrical Data 9 ...................................................................................................
Parts Included (Appearance May Vary) 10 ..........................................................
Tools Needed 10 ..................................................................................................
How to Install the Unit .....................................................................................11
Window Requirements .................................................................................... 11
Storm Window Requirements .........................................................................11
Preparation of the Cabinet 12 ..............................................................................
Cabinet Installation..........................................................................................13
Unit Installation................................................................................................14
OPERATION 16 .................................................................................
Control Panel and Remote Control 16 .................................................................
Wireless Remote Control 17 ................................................................................
Air Direction 18 .....................................................................................................
Additional Features 18 ........................................................................................
SMART FUNCTIONS 19 ....................................................................
LG ThinQ Application ......................................................................................19
Smart Diagnosis 20 ..............................................................................................
MAINTENANCE 22 ............................................................................
Air Filter 22 ...........................................................................................................
TROUBLESHOOTING 23 ..................................................................
Before Calling for Service 23 ...............................................................................
Normal Sounds You May Hear 23 ........................................................................
WARRANTY 27 ..................................................................................
3
EN
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on
your appliance. Always read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you
and others.
All safety messages will follow the safety alert symbol and either the
word WARNING or CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow
instructions.
All safety messages will tell you what the potential hazard is, tell you
how to reduce the chance of injury, and tell you what may happen if the
instructions are not followed.
The following symbols are displayed on units.
This symbol indicates that this appliance uses a flammable
refrigerant. If the refrigerant is leaked and exposure to an
external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual should be read
carefully.
This symbol indicates that a service personnel should be
handling this equipment with reference to the Installation Manual.
This symbol indicates that information is available such as the
Operating Manual or Installation Manual.
5
EN
OPERATION
Use this appliance only for its intended purpose.
Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or
has missing or broken parts, including a damaged cord or plug.
Repair or immediately replace all power cords that have become frayed or otherwise damaged. Do
not use a cord that shows cracks or abrasion damage along its length or at either end.
Do not run cord under carpets or mats where it could be stepped on and damaged.
Keep the cord out from under heavy objects like tables or chairs.
Do not place the power cord near a heat source.
Do not use an adaptor or plug the product into a shared outlet.
Do not tamper with controls.
If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact the LG Electronics Customer Information Center.
Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull
straight out from the outlet.
Do not grasp the power cord or touch the appliance controls with wet hands.
If water enters the product, turn off the power at the main circuit, then unplug the product and call for service.
If the product has been submerged, contact the LG Electronics Customer Information Center for
instructions before resuming use.
Unplug the product when unused for long periods.
Unplug the product before cleaning.
In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the use of the appliance by a person responsible for their safety.
The interior of the product must only be cleaned by an authorized service center or a dealer.
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
product failure, electrical shock, or fire.
GROUNDING INSTRUCTIONS
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
customer should have the wall receptacle and circuit checked by a qualified electrician to make
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
Situations when the appliance will be disconnected occasionally; Because of potential safety
hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an
adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from
most local hardware stores. The large slot in the adapter must be aligned with the large slot in
the receptacle to assure a proper polarity connection.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
through the house wiring. The customer should have the circuit checked by a qualified electrician
to make sure the receptacle is properly grounded.
Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
Situations when the appliance will be disconnected often; Do not use an adapter plug in these
situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground
terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead.
6
EN
CAUTION
To reduce the risk of minor or moderate injury to persons,
malfunction, or damage to the product or property when using this
product, follow basic precautions, including the following:
INSTALLATION
Take care when installing the product that exhaust or condensation does not damage nearby
property.
Follow installation instructions exactly to avoid excessive vibration or water leakage.
Wear gloves and use caution when unpacking and installing the appliance. Screws or sharp edges
can cause injuries.
OPERATION
This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
Make sure the air inlet and outlet are free from obstructions.
Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
Do not step on or place heavy objects on top of the appliance.
Do not operate the appliance without the filter securely installed.
Do not drink water drained from the appliance.
Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater
are used simultaneously.
Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for
extended periods of time.
Remove the batteries if the remote control is not to be used for an extended period of time.
Never mix different types of batteries, or old and new batteries for the remote control.
Stop using the remote control if there is a fluid leak in the battery. If your clothes or skin are
exposed to the leaking battery fluid, wash off with clean water.
If the leaking battery fluid has been swallowed, rinse the inside of the mouth thoroughly and
consult a doctor.
Do not recharge or disassemble the batteries.
MAINTENANCE
Clean the filter every two weeks.
Never touch the metal parts of the air conditioner when removing the air filter.
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Use a smooth cloth.
7
EN
REFRIGERANT (FOR R32 ONLY)
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those recommended
by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources (for
example: open flames an operating gas appliance or an operating electric heater).
Do not pierce or burn. Be aware that flammable refrigerants may not contain an odor.
CAUTION
This unit contains flammable refrigerant and has special safety precautions not normally
associated with older units. Please follow all precautions and advisories.
Use caution while handling and prevent damage to unit. Do not put any holes into product for
any reason. This can cause damage to product and prevent unit from cooling.
Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly
clean unit can result in damage to the refrigeration system and or the electrical system.
Make certain that all the air circulation/ventilation openings are free from obstruction.
Service should only be performed by technicians properly trained and certified in the use of
flammble refrigerants. Any service performed by unauthorized servicers/individuals will void all
warranties.
When storing the appliance, do not put in a room with any open flame appliance, such as gas
water heaters or furnaces. Also keep away from electric heaters. Damaged units should be
repaired before storage.
SAVE THESE INSTRUCTIONS
8
EN
PRODUCT OVERVIEW
Exterior Parts Interior Parts
7
6
1
4
32
5
8
9
3
4
5
6
7
1
2
1
Control Panel
1
Evaporator
2
Remote Control
2
Air Guide
3
Air Filter
3
Brace
4
Vertical Air Deflector (Horizontal Louver)
4
Compressor
5
Horizontal Air Deflector (Vertical Louver)
5
Condenser
6
Front Grille
6
Base Pan
7
Air Outlet
7
Power Cord
8
Cabinet
9
Air Inlet
9
EN
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. and buttons are provided TEST RESET
on the plug case. The device should be tested on
a periodic basis by frist pressing the button TEST
and then the button. If the button RESET TEST
does not trip or if the button will not stay RESET
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
for 120 V
Use Wall Receptacle Power Supply
Standard 120 V, 3-wire
grounding receptacle rated
15 A / 120 VAC / 60 Hz
Use 15 A, time
delay fuse or 15 A,
circuit breaker.
WARNING
This appliance should be installed in
accordance with the National Electrical Code.
Use of extension cords could cause serious
injury or death.
Do not use an extension cord with this
window air conditioner.
Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
Never push the TEST button during operation.
Doing so can damage the plug.
Do not remove, modify, or immerse this
plug. If this device trips, the cause should be
corrected before further use.
CAUTION
The conductors inside this cord are surrounded
by shields, which monitor leakage current.
These shields are not grounded. Periodically
examine the cord for any damage. Do not
use this product in the event the shields
become exposed. Avoid shock hazard. This
unit cannot be user-serviced. Do not open the
tamperresistant sealed portion. All warranties
and performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
10
EN
Parts Included (Appearance May Vary)
Heatproof foam (2)
(Adhesive backed)
Right curtain
panel
Left curtain
panel
Foam strip
(Non-adhesive)
Foam-PE (2)
(Adhesive backed)
Frame guide (2)
Window locking
bracket
Sill support (2)
T
T
T
Type “A” Screws
ype “A” Screws
ype “A” Screws
ype “A” ScrewsType “A” Screws
(14)
(14)
(14)
(14)(14)
T
T
T
Type “B” Screws
ype “B” Screws
ype “B” Screws
ype “B” ScrewsType “B” Screws
(3)
(3)
(3)
(3)(3)
T
T
T
Type “C” Screws
ype “C” Screws
ype “C” Screws
ype “C” ScrewsType “C” Screws
(5)
(5)
(5)
(5)(5)
Bolts
Bolts
Bolts
BoltsBolts
(2)
(2)
(2)
(2)(2)
Lock Nuts
Lock Nuts
Lock Nuts
Lock NutsLock Nuts
(2)
(2)
(2)
(2)(2)
Tools Needed
Phillips-head screwdriver
Phillips-head screwdriver
Phillips-head screwdriver
Phillips-head screwdriverPhillips-head screwdriver Adjustable wrench
Adjustable wrench
Adjustable wrench
Adjustable wrenchAdjustable wrench Level
Level
Level
LevelLevel Gloves
Gloves
Gloves
GlovesGloves
T
T
T
Tape measure
ape measure
ape measure
ape measureTape measure Scissors or Cutting knife
Scissors or Cutting knife
Scissors or Cutting knife
Scissors or Cutting knifeScissors or Cutting knife Pencil
Pencil
Pencil
PencilPencil
11
EN
How to Install the Unit
1 To prevent vibration and noise, make sure the
unit is installed securely and firmly.
2 Install the unit out of direct sunlight.
3 There should be no obstacles, such as a
fence or wall, within 20” (508mm) from the
back of the cabinet because it will prevent
heat radiation of the condenser. Restriction
of outside air will greatly reduce the cooling
efficiency of the air conditioner.
CAUTION
DO NOT cover or block any of the side and top
louvers. All side louvers of the cabinet must
remain exposed to the outside of the structure
and unobstructed.
4 Install the unit slightly tilted so the back
is slightly lower than the front (about 1/2”
(12.7mm)). This will force condensed water to
flow to the outside.
5 Install the unit with the bottom between
30”~ 60” (762mm ~ 1524mm) above the floor
level.
Window Requirements
This unit is designed for installation in standard
double hung windows with actual opening
widths from 27” to 39” (686mm to 991mm).
The top and bottom window sashes must open
sufficiently to allow a clear vertical opening of
16” (406mm) from the bottom of the upper sash
to the inside sill.
27” to 39
27” to 39
27” to 39
27” to 3927” to 39
16” (406mm) min
16” (406mm) min
16” (406mm) min
16” (406mm) min16” (406mm) min
(686mm to 991mm)
(686mm to 991mm)
(686mm to 991mm)
(686mm to 991mm)(686mm to 991mm)
NOTE
All supporting parts should be secured to firm
wood, masonry, vinyl, fiberglass, or metal.
This product is a window air conditioner. As
such, a standard single-hung or double-hung
window is required for proper installation. Non-
window installations, including using sleeves or
wall openings, and other installation methods
are not recommended.
Storm Window Requirements
1 Windows that include a storm window frame
may prevent the air conditioner from tilting down
toward the outside to drain properly. For proper
drainage, attach a 2” x 2” (50.8mm x 50.8mm)
piece of wood to the inner sill, trimmed to a
length which fits inside the window frame.
The
top of the wood shim must be at least 1 1/4
(38.1mm) higher than the top of the storm
window frame. Attach the wood securely to the
sill with nails or screws.
2 If necessary, attach another 2” x 2” (50.8mm x
50.8mm) wood strip flush against the back of
the inner sill. This will raise the L bracket, as
shown in the drawing.
Indoors
Inner Sill
Nail or screw
Outer Sill
Storm
Window Frame
Wood Strip Mounted
on Top of Inner Sill
1 1/4” (38.1mm) higher
than storm window frame
Outdoors
12
EN
Preparation of the Cabinet
1 Remove 4 screws which fasten the cabinet at
both sides and at the back. (Keep the screws
for later use.)
Shipping
Shipping
Shipping
Shipping Shipping
Screws
Screws
Screws
ScrewsScrews
2 Slide the unit from the cabinet by gripping the
base pan handle and pulling forward while
bracing the cabinet.
CAUTION
The unit is heavy. To prevent injury, use proper
lifting techniques when pulling unit forward
from cabinet. Obtain assistance from another
person if possible.
3 Cut the window sash seals (Foam-PE) to the
proper length. Peel off the backing and attach
the adhesive-backed foam to the underside
of the window sash and the bottom of the
window frame.
Foam-PE
Foam-PE
Foam-PE
Foam-PE Foam-PE
(Adhesive backed)
(Adhesive backed)
(Adhesive backed)
(Adhesive backed)(Adhesive backed)
4 Insert the hooks on the lower panel guides
into the slots on the bottom of the cabinet.
Make sure that the flanges on the lower panel
guides will face toward the inside of the room.
Hook
Hook
Hook
HookHook
Indoor
Indoor
Indoor
IndoorIndoor
5 Insert the top and bottom rails of the curtain
panels into the upper and lower panel guides.
Upper Panel Guide
Upper Panel Guide
Upper Panel Guide
Upper Panel GuideUpper Panel Guide
Right Curtain Panel
Right Curtain Panel
Right Curtain Panel
Right Curtain PanelRight Curtain Panel
Lower Panel
Lower Panel
Lower Panel
Lower Panel Lower Panel
Guide
Guide
Guide
GuideGuide
Left Curtain Panel
Left Curtain Panel
Left Curtain Panel
Left Curtain PanelLeft Curtain Panel
CAUTION
The lower panel guides are easily broken. Be
careful with them when installing the cabinet.
6 Fasten the curtain panels to the unit with 8
type A screws.
Fasten the screws behind the curtain panel.
Screws
Screws
Screws
Screws Screws
(T
(T
(T
(Type A)
ype A)
ype A)
ype A)(Type A)
Screws
Screws
Screws
Screws Screws
(T
(T
(T
(Type A)
ype A)
ype A)
ype A)(Type A)
NOTE
Use a long screwdriver to make installing the
screws easier.
13
EN
Cabinet Installation
Inside Sill
Inside Sill
Inside Sill
Inside SillInside Sill
Center Hole
Center Hole
Center Hole
Center HoleCenter Hole
Outside Sill
Outside Sill
Outside Sill
Outside SillOutside Sill
1 Open the window. Mark a line on the center of
the inside sill.
Carefully place the cabinet in the window and
align the center hole on the cabinet bottom
front with the center line on the sill.
Inside Sill
Inside Sill
Inside Sill
Inside SillInside Sill
Center Hole
Center Hole
Center Hole
Center HoleCenter Hole
2 Pull the bottom window sash down behind the
upper guide until It meets the cabinet.
Window Sash
Window Sash
Window Sash
Window SashWindow Sash
Upper Panel
Upper Panel
Upper Panel
Upper Panel Upper Panel
Guide
Guide
Guide
GuideGuide
NOTE
Do not pull the window sash down so tightly
that the movement of the curtain panels is
restricted.
3 Loosely assemble each sill support.
Sill Support
Sill Support
Sill Support
Sill SupportSill Support
Nut
Nut
Nut
NutNut
Bolt
Bolt
Bolt
BoltBolt
NOTE
If the distance to the outer window sill is not
that deep, you may not need the bolt and nut.
4 Use 2 type A screws to attach a sill support
to the cabinet track holes on one side. Use
the cabinet track holes that will place the sill
support nearest to the outer edge of the sill.
The longer side of the sill support should be
facing outside the window.
Repeat with the second sill support on the
opposite side of the cabinet.
Screws
Screws
Screws
Screws (T
(T
(T
(Type A)
ype A)
ype A)
ype A)Screws (Type A)
Indoor
Indoor
Indoor
IndoorIndoor
Cabinet T
Cabinet T
Cabinet T
Cabinet Track
rack
rack
rack Holes
Holes
Holes
HolesCabinet Track Holes
Outdoor
Outdoor
Outdoor
OutdoorOutdoor
5 Install the cabinet with a slight tilt (about 1/2”
(12.7mm)) downward on the outside.
Use the bolt and nut to adjust the tilt of the
cabinet.
about 1/2”
about 1/2”
about 1/2”
about 1/2” about 1/2”
(12.7mm)
(12.7mm)
(12.7mm)
(12.7mm)(12.7mm)
Cabinet
Cabinet
Cabinet
CabinetCabinet
CAUTION
Do not drill a hole in the bottom pan.
The product is designed to operate with
approximately 1/2” (12.7mm) of water in the
bottom pan. There is no need to add water if
the pan is dry.
14
EN
6 Mount the cabinet to the window sill using 3
type B screws in the holes on the front angle.
Sash Track
Sash Track
Sash Track
Sash TrackSash Track
Front Angle
Front Angle
Front Angle
Front AngleFront Angle
Screws (T
Screws (T
Screws (T
Screws (Type B)
ype B)
ype B)
ype B)Screws (Type B)
7 Pull each curtain panel out until it meets the
window sash track.
Sash Track
Sash Track
Sash Track
Sash TrackSash Track
Front Angle
Front Angle
Front Angle
Front AngleFront Angle
Upper Panel
Upper Panel
Upper Panel
Upper Panel Upper Panel
Guide
Guide
Guide
GuideGuide
Inside Window Sill
Inside Window Sill
Inside Window Sill
Inside Window SillInside Window Sill
8 Use a screwdriver or power drill to attach
the curtain panels to the window sashes by
inserting type C screws into the sashes through
the cabinet holes shown in the figure below.
Screws
Screws
Screws
Screws Screws
(T
(T
(T
(Type C)
ype C)
ype C)
ype C)(Type C)
Unit Installation
1 With the aid of an assistant, slide the unit into the
cabinet. Do not push on the controls or the finned
coils. Reinstall the screws removed from the
cabinet sides in step 1 of preparation of cabinet.
CAUTION
The unit is heavy. Use an assistant to help
lift the unit and set it in place. Lifting and
maneuvering the unit by yourself could result
in injury.
Hold the unit firmly in place until the window
frame is lowered to meet the top surface of the
unit directly behind the upper guide. If the unit
falls from the window, it could cause personal
injury or property damage.
2 Cut the non-adhesive foam strip to the proper
length and insert it between the upper window
sash and the lower window sash.
Foam Strip
Foam Strip
Foam Strip
Foam Strip Foam Strip
(Non-adhesive)
(Non-adhesive)
(Non-adhesive)
(Non-adhesive)(Non-adhesive)
3 To prevent broken glass or damage
to windows, on vinyl or other similarly
constructed windows, attach the window
locking bracket with a type C screw.
Screw
Screw
Screw
Screw Screw
(T
(T
(T
(Type C)
ype C)
ype C)
ype C)(Type C)
Window Locking Bracket
Window Locking Bracket
Window Locking Bracket
Window Locking BracketWindow Locking Bracket
Vinyl
Vinyl
Vinyl
VinylVinyl
Screw
Screw
Screw
Screw Screw
(T
(T
(T
(Type C)
ype C)
ype C)
ype C)(Type C)
Wood
Wood
Wood
WoodWood
15
EN
4 Connect the wire harness before assembling
the front grille.
5 Remove air filter from the front grille by pulling
the filter forward and then up slightly. Secure it
with 2 type A screws through the front grille.
6 After the air conditioner is installed, measure
the curtain panel on each side and cut the
adhesive-backed heatproof foam to fit each
panel. The size of the panels may differ.
Remove the backing from the heatproof foam
and attach the foam to the curtain panels.
H
W1
W2
W1
W2 W
H
W
H
H
Heatproof Foam
Heatproof Foam
Heatproof Foam
Heatproof FoamHeatproof Foam
(Adhesive Backed)
(Adhesive Backed)
(Adhesive Backed)
(Adhesive Backed)(Adhesive Backed)
NOTE
Heatproof foam improves the cooling capability
of the air conditioner.
See the Electrical Data section for information
on attaching the power cord to an electrical
outlet.
16
EN
OPERATION
Control Panel and Remote Control
4 3 2 1
7
65
Remote Control
1
4
2
7
3
NOTE
The feature may be changed according to the type of model.
1
Power
Press to turn the air conditioner ON or
OFF.
4
Operation Mode
Press the Mode button to cycle between 4
types of air conditioner operation: Energy
Saver / Cool / Fan / Dry.
Energy Saver - In this mode the compressor
and fan turn off when the set temperature
is achieved. Approximately every 3 minutes
the fan turns on to allow the unit sensor to
accurately determine if more cooling is needed.
Cool - This mode is ideal on hot days to cool
and dehumidify the room quickly. Use the
Temp buttons to set the desired room
temperature and use the button to Fan Speed
set the desired fan circulation speed.
Fan - In this mode the fan circulates air but the
compressor does not run. Use the Fan Speed
button to set fan speed to High, Medium or
Low. In this mode, you cannot adjust the set
temperature.
Dry - This mode is ideal for rainy and damp
days to dehumidify the room rather than cooling
it significantly. Humidity is removed from
the room by the combination of compressor
operation and the fan speed fixed at Low.
The compressor and fan turn off once the set
temperature is reached. Fan speed cannot be
adjusted in Dry mode.
2
Fan Speed
Press to set the Fan Speed to Low (F1),
Medium (F2) or High (F3).
3
Delay ON/OFF Timer
Delay ON - When the air conditioner is off,
set it to automatically turn on from 1 to 24
hours later, at its previous mode and fan
settings.
Delay OFF - When the air conditioner is
on, set it to automatically turn off from 1 to
24 hours later.
NOTE
Each press of the button Timer
advances the timer by 1 hour. After
the last press the display returns to the
temperature setting.
17
EN
5
Wi-Fi (Wi-Fi Model Only)
Enables connection of the air conditioner to
the home Wi-Fi.
NOTE
Follow instructions on ThinQ application
on how to connect to your unit.
6
Clean Filter
The Clean Filter LED lights up to notify you
that the filter needs to be cleaned. After
cleaning the filter, press Temp and
together on the control panel to turn off the
Clean Filter light.
NOTE
The filter reset must be done using the
control panel, not the remote control.
This feature is a reminder to clean the
air filter for more efficient operation.
The LED light turns on after 250 hours
of operation.
7
Temperature Control
The thermostat monitors room
temperature to maintain the desired
temperature. The thermostat can be set
between 60 °F–86 °F (16 °C–30 °C).
Press or arrows to increase or
decrease temperature setting.
NOTE
Auto Restart : If the air conditioner turns
off due to a power outage, it will restart
automatically once the power is restored, with
the same settings as were set before the unit
turned off.
Energy Saver : The unit defaults to the Energy
Saver mode each time the unit is switched on
except in Fan mode or when power is restored
after an electrical power outage.
The remote control will not function properly if
the AC infrared sensor is exposed to direct light
or if there are obstacles between the remote
controller and the air conditioner.
Wireless Remote Control
Inserting Batteries
1 Push out the cover on the back of the remote
control with your thumb.
2 With the plus and minus poles facing as
marked, and insert two new AAA 1.5 V
batteries.
3 Reattach the cover.
NOTE
New batteries are supplied with the air
conditioner for use in the remote control.
Do not use a rechargeable battery. Make sure
that the battery is new.
In order to prevent discharge, remove the
battery from the remote control if the air
conditioner is not going to be used for an
extended period of time.
Keep the remote control away from extremely
hot or humid places.
To maintain optimal operation of the remote
control, the remote sensor should not be
exposed to direct sunlight.
18
EN
Air Direction
Airflow can be adjusted by changing the direction
of the air conditioner’s louvers.
Adjusting Horizontal Airflow
Direction
The horizontal airflow is adjusted by moving the
levers of the vertical louvers to the left or right.
Adjusting Vertical Airflow
Direction
Touch the horizontal louvers to adjust the airflow
up or down.
NOTE
When the weather is extremely hot, the unit
may turn off automatically to protect the
compressor.
Additional Features
Slinger Fan
This air conditioner is equipped with a slinger fan.
(See drawing.)
The fan’s outer ring picks up the condensed water
from the base pan if the water level gets high
enough. The water is then picked up by the fan
and expelled through the condenser, making the
air conditioner more efficient.
Ring
Ring
Ring
RingRing
19
EN
SMART FUNCTIONS
LG ThinQ Application
This feature is only available on models with
the or logobThinQ
The application allows you to LG ThinQ
communicate with the appliance using a
smartphone.
LG ThinQ Application Features
Communicate with the appliance from a
smartphone using the convenient smart features.
Smart Diagnosis
If you experience a problem while using the
appliance,this smart diagnosis feature will help you
diagnose the problem.
Settings
Allows you to set various options on the appliance
and in the application.
NOTE
If you change your wireless router, internet
service provider, or password, delete the
registered appliance from the LG ThinQ
application and register it again.
The application is subject to change for
appliance improvement purposes without
notice to users.
Functions may vary by model.
Before Using LG ThinQ
Application
1 Check the distance between the appliance
and the wireless router (Wi-Fi network).
If the distance between the appliance and
the wireless router is too far, the signal
strength becomes weak. It may take a long
time to register or installation may fail.
2 Turn off the or on Mobile data Cellular Data
your smartphone.
3 Connect your smartphone to the wireless
router.
NOTE
To verify the Wi-Fi connection, check that f
icon on the control panel is lit.
The appliance supports 2.4 GHz Wi-Fi
networks only. To check your network
frequency, contact your Internet service
provider or refer to your wireless router manual.
LG ThinQ is not responsible for any
network connection problems or any faults,
malfunctions, or errors caused by network
connection.
If the appliance is having trouble connecting
to the Wi-Fi network, it may be too far from
the router. Purchase a Wi-Fi repeater (range
extender) to improve the Wi-Fi signal strength.
The Wi-Fi connection may not connect or may
be interrupted because of the home network
environment.
The network connection may not work properly
depending on the Internet service provider.
The surrounding wireless environment can
make the wireless network service run slowly.
The appliance cannot be registered due to
problems with the wireless signal transmission.
Unplug the appliance and wait about a minute
before trying again.
If the firewall on your wireless router is enabled,
disable the firewall or add an exception to it.
The wireless network name (SSID) should be
a combination of English letters and numbers.
(Do not use special characters.)
Smartphone user interface (UI) may vary
depending on the mobile operating system
(OS) and the manufacturer.
If the security protocol of the router is set
to WEP, you may fail to set up the network.
Please change it to other security protocols
(WPA2 is recommended) and register the
product again.
20
EN
Installing the LG ThinQ
Application
Search for the LG ThinQ application from the
Google Play Store or Apple App Store on a
smartphone. Follow instructions to download and
install the application.
Open Source Software Notice
Information
To obtain the source code under GPL, LGPL,
MPL, and other open source licenses that have
the obligations to disclose source code, that
is contained in this product, and to access all
referred license terms, copyright notices and
other relevant documents please visit https://
opensource.lge.com.
LG Electronics will also provide open source code
to you on CD-ROM for a charge covering the cost
of performing such distribution (such as the cost of
media, shipping, and handling) upon email request
to opensource@lge.com.
This offer is valid to anyone in receipt of this
information for a period of three years after our last
shipment of this product.
Smart Diagnosis
This feature is only available on models with the
c d or logo.
Use this feature to help you diagnose and solve
problems with your appliance.
NOTE
For reasons not attributable to LGE’s
negligence, the service may not operate due
to external factors such as, but not limited to,
Wi-Fi unavailability, Wi-Fi disconnection, local
app store policy, or app unavailability.
The feature may be subject to change without
prior notice and may have a different form
depending on where you are located.
Using LG ThinQ to Diagnose
Issues
If you experience a problem with your Wi-Fi
equipped appliance, it can transmit troubleshooting
data to a smartphone using the LG ThinQ
application.
Launch the LG ThinQ application and select
the feature in the menu. Smart Diagnosis
Follow the instructions provided in the
LG ThinQ application.

Termékspecifikációk

Márka: LG
Kategória: nincs kategorizálva
Modell: LW1222ERSM

Szüksége van segítségre?

Ha segítségre van szüksége LG LW1222ERSM, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva LG

LG

LG W2442PA Útmutató

28 Március 2025
LG

LG GB109 Útmutató

28 Március 2025
LG

LG L227WT Útmutató

27 Március 2025
LG

LG F7250 Útmutató

23 Március 2025
LG

LG NA2000 Útmutató

23 Március 2025
LG

LG LWP-273N Útmutató

23 Március 2025
LG

LG XC-12 Útmutató

22 Március 2025
LG

LG LKAEH09B Útmutató

15 Március 2025
LG

LG DTL-7740 Útmutató

10 Január 2025
LG

LG LPC-LM440 Útmutató

10 Január 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva