ELECTRIC HEATERS
INSTALLATION INSTRUCTIONS
Models: LKAEH052, LKAEH102, LKAEH152,
LKAEH09B, LKAEH18B, LKAEH36B, LKAEH36BL
• Please read this instruction sheet completely before installing the product.
• Installation work must be performed in accordance with national wiring standards by authorized
personnel only.
P/No.: 3828A30038B
2
Table 1 Accessory Heaters Electrical Data
Ton
3RT
4/5RT
6.25/7.5RT
8.5/10/12.5
RT
15/17.5RT
20/25RT
Heater
Model No.
LKAEH052
LKAEH102
LKAEH052
LKAEH102
LKAEH152
LKAEH09B
LKAEH18B
LKAEH09B
LKAEH18B
LKAEH18B
LKAEH36B
LKAEH36BL
Heater
KW Rating
3.6/5.0
7.2/10.0
3.6/5.0
7.2/10.0
14.4/15.0
7.8/9.0
15.6/18.0
7.8/9.0
15.6/18.0
15.6/18.0
31.2/36.0
31.2/36.0
Control
Stages
1
1
1
1
1
1
1
1
1
1
2
2
27.6/32.2
47.4/55
29.6/34.2
49.4/57.0
69.0/79.7
30.4/35.1
50.9/58.7
35.7/41.2
56.2/64.8
56.2/64.8
97.1/112.1
97.1/112.1
60/60
60/60
60/60
60/60
90/90
60/60
70/70
60/60
70/70
70/70
125/125
125/125
60/60
60/60
60/60
60/60
90/90
60/60
70/70
60/60
70/70
70/70
125/125
125/125
-
-
-
-
-
33.0/38.1
53.3/61.5
42.0/48.4
62.4/72.0
62.4/72.0
103.4/119.3
103.4/119.3
-
-
-
-
-
60/60
70/70
60/60
80/80
80/80
125/125
125/125
-
-
-
-
-
60/60
70/70
60/60
80/80
80/80
125/125
125/125
Heater
Rated Volts
208-240/60/1
208-240/60/1
208-240/60/1
208-240/60/1
208-240/60/1
208-240/60/3
208-240/60/3
208-240/60/3
208-240/60/3
208-240/60/3
208-240/60/3
208-240/60/3
Standard indoor fan motor
M.C.A M.C.AM.F.S M.F.SM.C.B M.C.B
Over size indoor motor
Note; Heater KW ratings are at 208/240V for 220V unit.
M.C.A; Minimum Circuit Ampere
M.F.S; Maximum Fuse Size
M.C.B; Maximum Circuit Breaker
* HACR type Circuit Breaker per NEC.
Installation
1. Loosen the screw that secures heater
compartment access panel. Lift up, pull
towards you and slide it down to remove.
2. Remove four(4) screws from block off panel
to expose heater cavity and heaterʼs back
support bracket. Save screws for installing
heater later.(See Figure 2.)
Heater Access Panel
Compressor Access Panel
Figure 1
Figure 2
: Open and lock unit disconnect
switch before installing this accessory to prevent
injury or death due to electrical shock or contact
with moving parts.
WARNING
Support
Bracket
Block off panel
Heater Cavity
3
Heater and Control Box Assembly
3. Insert heater into the opening hole of heater
control box.
4. Align holes and secure screws to the control
box as shown in Figure 3.
Single Bank Heater Installation
-
LKAEH052, LKAEH102, LKAEH152,
LKAEH09B, LKAEH18B, LKAEH36BL
5. Place the heater control assembly in the
heater cavity.
6. Secure the heater control assembly of
heater cavity using four(4) screws. (See
Figure 4.)
Important: Make sure the heater arm slides
into heaterʼs back support bracket.
Two Bank Heaters Installation
-
LKAEH36B
7. For two heaters installation, align holes and
secure screws to the control box as shown
in Figure 3.
8. Secure the heater control assembly on
heater cavity using four(4) screws.(See
Figure 5)
Important: Make sure the heaterʼs arm slides
into heaterʼs back support bracket.
Heater Control Box
Heater
Figure 3
Figure 4
Figure 5

Termékspecifikációk

Márka: LG
Kategória: nincs kategorizálva
Modell: LKAEH36BL

Szüksége van segítségre?

Ha segítségre van szüksége LG LKAEH36BL, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva LG

LG

LG SR-M3DT97 Útmutató

3 Április 2025
LG

LG W2442PA Útmutató

28 Március 2025
LG

LG GB109 Útmutató

28 Március 2025
LG

LG L227WT Útmutató

27 Március 2025
LG

LG F7250 Útmutató

23 Március 2025
LG

LG NA2000 Útmutató

23 Március 2025
LG

LG LWP-273N Útmutató

23 Március 2025
LG

LG XC-12 Útmutató

22 Március 2025
LG

LG LKAEH09B Útmutató

15 Március 2025
LG

LG DTL-7740 Útmutató

10 Január 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva