Ducted Gas Heaters
Safety Information
Installation
Commissioning
Models
INSTALLER’S
MANUAL
Universal:
KUN3 | KUN4 | KUN5
External
KEX3 | KEX4
Kaden Installer's Manual
Ducted Gas Heaters
2
Table of Contents
Warnings and Important Information 4
Scope 6
1. General Guidelines 7
1.1 Inspection ......................................................................................................................................................... 7
1.2 Unpacking the Heater ...................................................................................................................................... 7
1.3 Unloading or Lifting the Heater ........................................................................................................................ 7
1.4 Gas Inlet Connection ....................................................................................................................................... 8
1.5 Electrical Power Supply ................................................................................................................................... 8
1.6 Installation of Duct Connection Pops ............................................................................................................... 8
1.7 Heater Positioning ............................................................................................................................................ 9
1.8 Installation of Internal Heaters ......................................................................................................................... 9
1.8.1 Installing in the Roof Space ................................................................................................................. 9
1.8.2 Installing Beneath the Floor ................................................................................................................. 9
1.9 Installation of Internal Heaters - Room, Enclosure or Plant Room ................................................................ 10
1.10 External Installations ...................................................................................................................................... 10
2. KUN Universal Model Guidelines 11
2.1 Heater Dimensions ......................................................................................................................................... 11
2.2 Platform & Service Clearances ...................................................................................................................... 11
2.3 Internal Installation ........................................................................................................................................ 12
2.3.1 Splitting the Heater ............................................................................................................................ 12
2.3.2 POP Configuration Installation ........................................................................................................... 12
2.3.3 Return & Supply Air POP Rotation Procedure .................................................................................. 13
2.3.4 Internal Model Flueing Instructions .................................................................................................... 14
2.3.5 Kaden Remote Flue Terminal ............................................................................................................ 14
2.4 External Installation ........................................................................................................................................ 15
2.4.1 Supply Air Overheat Switch Position (KUN530 & KUN330 ONLY) ................................................... 15
2.4.2 Modifying KUN Model Duct Orientation ............................................................................................. 15
2.4.3 Installation of Flue Terminal ............................................................................................................... 16
2.4.4 Area to Cut Out in Wall ...................................................................................................................... 16
2.4.5 Installation of Flashing ....................................................................................................................... 17
2.4.6 KUN3 & KUN4 models ....................................................................................................................... 17
2.4.7 Thermistor Installation KUN4 & KUN5 ............................................................................................... 18
3. KUN4 & KUN5 19
3.1 Wiring a Damper Motor to the Heater’s Control Module ............................................................................... 19
3.1.1 Damper Motor Connections ............................................................................................................... 20
3.1.2 RJ Socket Connections ..................................................................................................................... 20
3.1.3 RJ12 socket detail on heater PCB ..................................................................................................... 20
4. KEX External Model Guidelines 21
4.1 Heater Dimensions ......................................................................................................................................... 21
4.2 Service Clearances ........................................................................................................................................ 21
4.3 Installation ...................................................................................................................................................... 22
4.3.1 Area to Cut Out in Wall ...................................................................................................................... 22
4.3.2 Installation of Flashing ....................................................................................................................... 22
4.3.3 Installation of Flue Terminal ............................................................................................................... 23
4.3.4 Flue Terminal Clearances .................................................................................................................. 23
3
5. Fan Speed KUN3, KEX3 & KEX4 24
5.1 Fan Speed Setting For KUN3, KEX3 & KEX4 Models .................................................................................. 24
5.1.1 To Adjust The Fan Speed .................................................................................................................. 24
6. Ducting Information 25
6.1 Minimum Recommended Return Air Grille Selection Chart .......................................................................... 25
7. Outlet Guide 26
7.1 Outlet Register Chart ..................................................................................................................................... 27
8. Wall Control Installation 28
8.1 Networker Installation KUN4 & KUN5 ............................................................................................................ 29
8.1.1 Wiring the Networker to a KUN4 & KUN5 Heater ............................................................................. 29
8.2 Manual Wall Control Installation .................................................................................................................... 30
8.2.1 Wiring the Manual Wall Control to a KUN3 Heater ........................................................................... 30
8.2.2 Wiring the Manual Wall Control to a KEX4 & KEX3 Heaters ............................................................ 30
9. Commissioning KUN4 & KUN5 32
9.1 Heater Control Settings .................................................................................................................................. 32
9.2 Installer Parameters Via Networker ............................................................................................................... 33
9.2.1 Networker Installer Parameter KUN4 & KUN5 .................................................................................. 33
9.2.2 Adjust Networker Parameters ............................................................................................................ 34
9.3 KUN4 & KUN5 Commissioning Instructions .................................................................................................. 34
9.3.1 Initial Ignition and Gas Inlet Pressure Check .................................................................................... 34
9.3.2 Heater Fan Speed and Temperature Settings ................................................................................... 35
9.3.3 Final Checks ...................................................................................................................................... 36
9.4 Fault Code Identification on Heater PCB ....................................................................................................... 36
9.4.1 NG-3 L.E.D Identification ................................................................................................................... 36
9.4.2 Error codes associated with installation ............................................................................................ 37
10. Commissioning KUN3, KEX3 & KEX4 38
10.1 Commissioning Instructions ........................................................................................................................... 38
10.1.1 Start & Check Supply Pressure ......................................................................................................... 38
10.1.2 Start & Check Burner Pressure ......................................................................................................... 38
10.1.3 Setting the Fan Speed ...................................................................................................................... 39
10.1.4 Final Checks ...................................................................................................................................... 39
11. Technical Specifications 40
12. Technical Support 41

Termékspecifikációk

Márka: Kaden
Kategória: Fűtő
Modell: KEX315

Szüksége van segítségre?

Ha segítségre van szüksége Kaden KEX315, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók Fűtő Kaden

Kaden

Kaden KEX320 Útmutató

15 Augusztus 2024
Kaden

Kaden KEX420 Útmutató

15 Augusztus 2024
Kaden

Kaden KEX428 Útmutató

15 Augusztus 2024
Kaden

Kaden KEX315 Útmutató

15 Augusztus 2024
Kaden

Kaden KEX415 Útmutató

15 Augusztus 2024
Kaden

Kaden KEX328 Útmutató

15 Augusztus 2024

Útmutatók Fűtő

Legújabb útmutatók Fűtő