Temperature Management Radio-controlled valve drive
Ref.-no.: ..HLK-FMS..
Operating Instructions
Radio-controlled valve drive
Table of contents
1. About these instructions .................................................................. 2
2. Device presentation .......................................................................... 2
3. Mounting ............................................................................................ 3
4. Removal.............................................................................................. 3
5. Power supply ..................................................................................... 4
5.1. Insert battery ................................................................................. 4
5.2. Behaviour with decreasing battery voltage................................... 5
6. Teaching in radio-controlled valve drive ........................................ 5
6.1. Radio-controlled valve drive is outside teach-in range................. 6
7. Deleting a radio assignment ............................................................ 6
8. Polling valve position (stroke display)............................................ 7
9. Actual value calibration.................................................................... 7
10. Connection of remote sensor .......................................................... 8
11. Changing closing force control ....................................................... 8
12. Temperature adjustment .................................................................. 9
12.1. Setting temperature adjustment.................................................... 9
13. Diagnostic function......................................................................... 10
14. Designing antenna .......................................................................... 11
15. Information on radio operation...................................................... 12
16. Radio transmission......................................................................... 12
17. Technical data ................................................................................. 12
18. Guarantee......................................................................................... 13
Stand: Sep-08
Temperature Management Radio-controlled valve drive
Ref.-no.: ..HLK-FMS..
1. About these instructions
The following symbols and marks are used in these instructions:
1. Action instructions are numbered consecutively.
9 Results of actions are identied by this check mark.
Enumerations are identified by this point.
Note!
Information on the economical use of the radio room temperature sensor
is identified by this sign.
Attention
Information on facts which can lead to damage to persons or the device
are identified by this sign
2. Device presentation
The Radio-controlled valve drive is a radio-controlled valve drive for
actuating heating valves for single-room control in conjunction with a
floor, radiator or convection heating system. The battery-operated radio-
controlled valve drive is operated via the radio room temperature sensor
or the radio controller.
The setpoint temperature can be adjusted at any time via the two buttons.
1 Temperature sensor for detecting the actual temperature
2 LED display, e.g. setpoint temperature, valve position
3 Blue button, e.g. lower temperature
4 Red button, e.g. raise temperature
5 Lockable cover
2
Temperature Management Radio-controlled valve drive
Ref.-no.: ..HLK-FMS..
3. Mounting
To mount the radio-controlled valve drive, proceed as follows:
1. Remove the existing mechanical heating thermostat.
2. Screw the included adapter ring onto the heating valve and tighten in
handtight.
3. Position the radio-controlled valve drive in the vertical position.
4. Push the radio-controlled valve drive onto the adapter ring until it
audibly engages.
5. Then insert the batteries and teach in the corresponding radio
transmitter in the radio motor drive.
4. Removal
You can remove the radio-controlled valve drive as follows:
1. Unlock the lower cover of the radiocontrolled valve drive with the
included special key and fold open the cover.
2. Press the red lever to the left.
3. Simultaneously pull the radiocontrolled valve drive off the adapter
ring.
3

Termékspecifikációk

Márka: Jung
Kategória: nincs kategorizálva
Modell: HLK-FMS

Szüksége van segítségre?

Ha segítségre van szüksége Jung HLK-FMS, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Jung

Jung

Jung SC0081U Útmutató

28 Március 2025
Jung

Jung MBT 2424 Útmutató

28 Március 2025
Jung

Jung NA7 Útmutató

28 Március 2025
Jung

Jung LS 4 AR Útmutató

28 Március 2025
Jung

Jung MALS1133 Útmutató

1 Január 2025
Jung

Jung MAAL1133 Útmutató

15 December 2024
Jung

Jung MAGO1193 Útmutató

10 December 2024
Jung

Jung MAA1193 Útmutató

10 December 2024
Jung

Jung MACD1193WW Útmutató

10 December 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

MOZA

MOZA SR-P Útmutató

10 Április 2025
CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025