Operating instructions
Temperature transmitter
TA1xxx
TA2xxx
80288950 / 0109 / 2021
GB
TA1xxx TA2xxx Temperature transmitter
2
Contents
1 Preliminary note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Warnings used ......................................................... 3
2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Intended use................................................................ 5
4 Function ................................................................... 6
4.1 Analogue output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 IO-Link ............................................................... 6
5 Installation.................................................................. 8
5.1 Use in hygienic areas according to 3-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2 Use in hygienic areas according to EHEDG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.3 Units with clamp process connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.4 Units with sealing cone process connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.4.1 Flush mount hygienic zero-leak using PEEK sealing. . . . . . . . . . . . . . . . . . . . . . . . . 10
5.4.2 Flush mount zero-leak using metal-to-metal seal . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.5 Units for process adaptation via clamping ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.6 Units for process adaption via zero void adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Parameter setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1 Adjustable parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8 Operation .................................................................. 14
9 Maintenance, repair and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10 Factory setting .............................................................. 16
Temperature transmitter TA1xxx TA2xxx
3
1 Preliminary note
You will find instructions, technical data, approvals and further information using the QR code on the
unit / packaging or at www.ifm.com.
1.1 Symbols used
Requirement
Instructions
Reaction, result
[...] Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note
1.2 Warnings used
CAUTION
Warning of personal injury
wSlight reversible injuries may result.
TA1xxx TA2xxx Temperature transmitter
4
2 Safety instructions
The unit described is a subcomponent for integration into a system.
The system architect is responsible for the safety of the system.
The system architect undertakes to perform a risk assessment and to create documentation in
accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.
Read this document before setting up the product and keep it during the entire service life.
The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.
Only use the product for its intended purpose ( Intended use).Ò
Only use the product for permissible media.
If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.
The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.
Protect units and cables against damage.
Temperature transmitter TA1xxx TA2xxx
5
3 Intended use
The unit monitors liquids and gases.
The unit detects the medium temperature and converts it into an analogue output signal.
TA1xxx TA2xxx Temperature transmitter
6
4 Function
4.1 Analogue output
The unit provides an analogue signal proportional to the process value.
The analogue signal is invertible:
4...20mA with setting [OU] = I
20...4mA with setting [OU] = Ineg
The measuring range is scalable: The parameters [ASP] and [AEP] allow for the measuring range to
be limited.
Minimum distance between ASP and AEP = 5°C or 9°F.
MAW MEW
20.6
20
4
3.7
T [°C/°F]
I [mA]
Fig.1: Maximum measuring range at [OU] = I
MAW: Initial value of the measuring range
MEW: Final value of the measuring range
I [mA]
T [°C/°F]MEW
MAW
AEPP
20.6
20
4
3.7
Fig.2: Scaled measuring range at [OU] = I
ASP: Analogue start value
AEP: Analogue end value
Within the measuring range, the output signal is between 4 and 20 mA. If the temperature value is
outside the limits of the measuring range, the following signal is provided:
Output signal at [OU] = I Output signal at [OU] = Ineg
Temperature > AEP 20...20.6 mA 4...3.7 mA
Temperature > MEW 20.6 mA 3.7 mA
Temperature < ASP 4...3.7 mA 20...20.6 mA
Temperature < MAW 3.7 mA 20.6 mA
In case of an internal fault, the output signal reacts according to the parameter set in [FOU] (3.5 mA or
21.1 mA).
4.2 IO-Link
This unit has an IO-Link communication interface which enables direct access to process and
diagnostic data. In addition it is possible to set the parameters of the unit while it is in operation.
Operation of the unit via the IO-Link interface requires an IO-Link master.
With a PC, suitable IO-Link software and an IO-Link adapter cable, communication is possible while
the system is not in operation.
The IODDs necessary for the configuration of the unit, detailed information about process data
structure, diagnostic information, parameter addresses and the necessary information about the
required IO-Link hardware and software can be found at www.ifm.com.
The IO-Link interface provides the following functions using suitable hardware and software:
Temperature transmitter TA1xxx TA2xxx
7
Remote parameter setting of the unit.
Noise-immune signal transmission without measured value losses.
Transmission of the parameter settings to a replaced unit or to other units of the same type.
Display of error and event messages.
Paperless logging of parameter sets, process values and diagnostic information.
Evaluation of the process values and diagnostic data via IO-Link master.
Display of minimum and maximum temperature values.
TA1xxx TA2xxx Temperature transmitter
8
5 Installation
CAUTION
During installation or in case of mechanical failure, high pressure or hot media can leak
from the system.
wRisk of injury caused by pressure or burns.
uEnsure that the system is free of pressure during installation.
uEnsure that no media can leak at the mounting location during installation.
5.1 Use in hygienic areas according to 3-A
uSecure clamp sensors with a suitable clamp.
uEnsure that the installation of the unit in the system complies with 3-A guidelines.
u ÒUse only process adapters with 3-A certification and marked with the 3-A symbol ( Accessories
at ).www.ifm.com
uFor use according to 3-A, take note of the corresponding regulations for cleaning and
maintenance.
uNot suitable for systems that have to meet the criteria of E1.2 / 63-03 of the 3-A standard
63-03.
2
3
4
5
1
Fig.3: Installation position for 3-A
certification
uThe positioning of the sensor must be observed to ensure the
mounting adapter will self-drain: Do not install the unit in positions 4
and 5.
5.2 Use in hygienic areas according to EHEDG
The sensor is suited for CIP (clean in place) when installed correctly.
uObserve the application limits (temperature and material resistance) according to the data
sheet.
uEnsure that the installation of the unit in the system complies with EHEDG.
uUse self-draining installation.
uOnly use process adapters permitted according to EHEDG with special seals required by the
EHEDG position paper.
uLeakage ports must be clearly visible and must be installed facing downwards for vertical pipes.
Temperature transmitter TA1xxx TA2xxx
9
uFor any structures in a tank, direct water jet cleaning and cleaning of any dead spaces must be
possible.
uAdhere to the dimensions shown in the following figure to avoid dead spaces that cannot be
cleaned effectively:
L<(D - d).
TA11xx
d
L
Ø D
3
4
5
1
= 6,65 mm
TA28xx
d = 6 mm
Ø D
L
3
2
TA25xx
d
L
Ø D
3
4
5
1
= 6 mm
1: Sealing ring between the housing and the process connection (E43911 /
E43915)
2: Sealing ring in accordance with EHEDG position paper
3: Adapter
4: Leakage port
5: PEEK sealing ring (E43911 / E43915)
5.3 Units with clamp process connection
The one-piece units of design TA28xx with clamp 1.5" are best suited for a hygienic installation.
Adhere to the installation instructions for use in hygienic areas according to 3-A or EHEDG.
5.4 Units with sealing cone process connection
The units of design TA25xx (G½ sealing cone) and TA11xx (M12 sealing cone) can be adapted to
standard process connections using two sealing versions. The following applies to both sealing
versions:
uOnly use accessories from ifm electronic. The optimum function is not ensured when using
components from other manufacturers.
uObserve the instructions of the adapter.

Termékspecifikációk

Márka: IFM
Kategória: nincs kategorizálva
Modell: TA2531

Szüksége van segítségre?

Ha segítségre van szüksége IFM TA2531, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva IFM

IFM

IFM E40581 Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025
IFM

IFM PG1704 Útmutató

9 Április 2025
IFM

IFM PE2599 Útmutató

23 Március 2025
IFM

IFM MK5312 Útmutató

23 Március 2025
IFM

IFM RU6035 Útmutató

18 Március 2025
IFM

IFM SF3210 Útmutató

18 Március 2025
IFM

IFM RU6045 Útmutató

18 Március 2025
IFM

IFM KI0200 Útmutató

18 Március 2025
IFM

IFM PT2400 Útmutató

16 Január 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva