Használati útmutató IFM AC2488

Olvassa el alább 📖 a magyar nyelvű használati útmutatót IFM AC2488 (7 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 7 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/7
Operating instructions
AS-i CompactModule M8
AC2488
AC2489
7390940/04 10/2018
UK
2
1 Preliminary note
Technical data, approvals, accessories and further information at
www.ifm.com.
1.1 Safety instructions
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose (→ Functions and features).
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
The plant manufacturer is responsible for the safety of the plant in which the
device is installed.
If the device is used in a way that is not intended by the manufacturer, the
protection supported by the device may be impaired.
Protect units and cables against damage.
1.2 Symbols used
► Instructions
> Reaction, result
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note
3
UK
2 Functions and features
AC2488: 8 inputs CTT3 (AS-i profile S-7.A.A) / AS-interface version 3.0 /
master profile M4 / extended addressing mode: yes / maximum number of
modules per master: 62
AC2489: 2x4 inputs (AS-i profile 2x S-0.A.E) / AS-interface version 3.0,
backwards compatible / master profile M3 or M4 / extended address mode:
yes / maximum number of modules per master: 31 (2 independent A/B slaves
per module)
3 Installation
Disconnect power before installation.
For installation choose a flat mounting surface.
The entire bottom of the module must lie flat on the mounting surface.
Fix the module onto the mounting surface using M4 screws and washers.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment
must be adhered to.
Disconnect the installation from power and connect the unit.
To ensure the protection rating:
Connect the plugs of the sensors to the M8 sockets.
Tighten firmly, recommended tightening torque 0.3...0.5 Nm.
Cover the unused sockets with the enclosed protective caps.
Tighten firmly, recommended tightening torque 0.3...0.5 Nm.

Termékspecifikációk

Márka: IFM
Kategória: nincs kategorizálva
Modell: AC2488

Szüksége van segítségre?

Ha segítségre van szüksége IFM AC2488, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva IFM

IFM

IFM E40581 Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025
IFM

IFM PG1704 Útmutató

9 Április 2025
IFM

IFM PE2599 Útmutató

23 Március 2025
IFM

IFM MK5312 Útmutató

23 Március 2025
IFM

IFM RU6035 Útmutató

18 Március 2025
IFM

IFM SF3210 Útmutató

18 Március 2025
IFM

IFM RU6045 Útmutató

18 Március 2025
IFM

IFM KI0200 Útmutató

18 Március 2025
IFM

IFM PT2400 Útmutató

16 Január 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva