INSTRUCTIONS FOR INSTALLATION AND USE
English
Version 12/20 ID no. 1-052-822
Full spectrum radiator
VITAE 350 / 500 / 750 / 1300
ECO 350 / 500 / 750
1-027-780 / DIR-350-R 1-027-845 / WIR-350-R
1-027-781 / DIR-500-R 1-027-846 / WIR-500-R
1-027-782 / DIR-750-R 1-027-847 / WIR-750-R
1-027-779 / DIR-1300-R 1-027-844 / WIR-1300-R
1-027-785 / ECO-350-R 1-027-784 / ECO-300-G
1-027-788 / ECO-500-R 1-027-787 / ECO-500-G
1-027-790 / ECO-750-R
Table of Contents
1. About this instruction manual 3
2. Important information for your safety 4
2.1. Intended use 4
2.2. Safety information 4
3. Product description 7
3.1. Scope of delivery 7
3.2. Product features 7
3.3. Optional accessories 7
4. Correct placement 8
5. Installation and connection 9
5.1. Safety distances 10
5.2. Installation cut-out 11
5.3. Recessed 12
6. Cleaning and maintenance 13
6.1. Cleaning 13
6.2. Maintenance 13
7. Disposal 13
8. Technical data 14
EN
Instructions for installation and use p. 3/16
1. About this instruction manual
Read these assembly instructions carefully and keep them within reach when
using the infrared radiator. This ensures that you can refer to information on
safety and use at any time.
Symbols used for warning notices
These assembly instructions feature warning notices next to activities that present
a hazard to the user. Always observe the warning notices. This prevents damage
to property and injuries, which in the worst case may be fatal.
The warning notices contain keywords, which have the following meanings:
DANGER!
Serious or fatal injury will occur if this warning notice is not observed.
WARNING!
Serious or fatal injury can occur if this warning notice is not observed.
CAUTION!
Minor injuries can occur if this warning notice is not observed.
ATTENTION!
This keyword is a warning that damage to property can occur.
Other symbols
This symbol indicates tips and useful information.
Do not cover Read the operating instructions
These installation and operating instructions can also be found in the
downloads section of our website: www.sentiotec.com/downloads.
EN
Instructions for installation and use p. 5/16
Ensure that the infrared radiator is not exposed to any mechani-
cal stress, as this will result in breakage. A radiator with a glass
front or radiator element that is broken may no longer be used.
The glass or the radiator element must be replaced (for the item
number, see 8. Technical data on page 14)
When positioning and installing the infrared radiator, the mini-
mum safety distances must be complied with (see 5.1. Safety
distances on page 10)
The radiator satises the requirements in accordance with IPX2.
For splashproof installation in accordance with IPX4, the edge of
the infrared radiator must be tted with a veneer (e.g: stainless
steel panel, see 3.3. Optional accessories on page 7)
Radiators must not be installed in a steam bath.
For your own safety, consult your supplier in the event of problems
that are not described in su󰀩cient detail in the user instructions.
Make sure that no ammable objects have been placed on or
suspended in front of the infrared radiator before the control unit
is switched on.
Never touch the glass on the infrared radiator when it is operating.
The glass on the infrared radiator becomes very hot. Depending
on the user function, contact protection may need to be installed
(e.g: wooden backrest, protective grille, see 3.3. Optional acces-
sories on page 7).
The device must not be used by children under 8 years of age.
EN
Instructions for installation and use p. 7/16
3. Product description
3.1. Scope of delivery
IR radiator incl. 3 m connection cable with plug
Assembly instructions
3.2. Product features
The infrared radiator features the following functions:
Installation as a back, front or ceiling radiator
Intrinsically safe due to safety temperature limiter
Innitely dimmable
Models with a glass cover feature protection class IPX4 (suitable for saunas)
when installed in combination with front panel or wooden backrest
VITAE full spectrum radiator Nextrema dark
Radiation intensity: A 24%, B 55%, C 21%
Nextrema full spectrum radiator white
Radiation intensity: A 9%, B 57%, C 34%
ECO full spectrum radiator with glass
Radiation intensity: A 24%, B 55%, C 21%
ECO full spectrum radiator with grille
Radiation intensity: A 14%, B 40%, C 46 %
3.3. Optional accessories
Brushed stainless steel front panel
(350W/1-027-948, 500/750/1300W/1-027-779)
Stainless steel front panel painted black
(350W/1-027-905, 500/750/1300W/1-027-157)
Protective grille (350/1-027-791, 500W/1-027-792)
Ergonomic backrest (350/500W/514-L/A/D)
Ergonomic VitaMy backrest (350W/1-039-182)
Instructions for installation and use p. 8/16
4. Correct placement
Application as:
Back radiator: 350 W, 500 W
Front radiator: 350 W, 500 W or 750 W
Ceiling radiator: 750 W, 1300 W
According to EN 60335-2-53, an infrared thermal cabin with a 20 cm x 20 cm
grid of averaged irradiation must not exceed 1000 W/m² on a person’s chest and
back (note that this limit relates to the prevention of heat stress).
To ensure that this limit is not exceeded, only a 350 W or 500 W radiator may be
used as a back radiator. Furthermore, when positioning the back radiator, ensure
that the distance from the person’s back to the radiator does not exceed 4 cm.
Only 350 W, 500 W or 750 W radiators may be used as front radiators. Ensure
that the minimum distance between the upper body and front radiator is not less
than 50 cm (in picture „x“)
Lime wood backrest (350W/1-028-578, 500/750W/1-032-185)
Prestige wooden backrest (350W/1-032-186, 500/750W/1-032-213)
Infrared distributor (IR-1P2, IR-1P3, IR-1P5)
Cable for distributor (IR-1P2, IR-1P3, IR-1P5)
Connection cable for distributor (IR-IS-A03, IR-IS-A10, IR-IS-A25)
Y
x
To ensure that the ICNIRP limit values for
the long-term limit value of 100 W/ for
“infrared eye” are not exceeded, the radia-
tors must be moved down (in picture„Y“).
Detailed information can be found in the
appraisals LE-G18/3 and LE-G31/18 con-
ducted by Seibersdorf Laboratories.
x ≥ 50 cm
Front radiator
EN
Instructions for installation and use p. 9/16
5. Installation and connection
The radiator is delivered with a plug already installed. The plug-in connector
may also be installed by the user.
If the radiator connection is integrated into a control unit, remove the plug.
The clamp connection may only be installed by a qualied electrician or
similarly qualied person.
The rear of the radiator must NOT be covered to ensure that the heat gener-
ated can escape through the openings.
The ventilation slots at the top and bottom must NOT be covered (see Fig. 1)
To ensure that the thermal fuse functions correctly, the terminal box for the
radiator must be at the top when the radiator is installed vertically (e.g. back
radiator) (see ). Fig. 14
Maintain the minimum safety distances to easily ammable materials
(see ).5.1. Safety distances on page 10
WARNING!
Danger of electric shock
Only perform installation and connection work on the infrared radiator
when the power supply has been disconnected.
Fig. 1: Fig. 2: Terminal box positionDo not cover
ventilation slots
Instructions for installation and use p. 10/16
5.1. Safety distances
Observe the specied minimum safety distances and Fig. 3.
Infrared radiator 350 W, 500 W
(DIR-350-R / DIR-500-R / WE-350-R / WE-500-R /
ECO-350-R / ECO-500-R / ECO-350-G / ECO-500-G)
When installed vertically: When installed horizontally:
B = 15 mm B = 80 mm
F = 25 mm F = 25 mm
Infrared radiator 750 W (DIR-750-R / WIR-750-R / ECO-750-R)
When installed horizontally:
B = 100 mm
F = 150 mm
Infrared radiator 1300 W (DIR-1300-R / WIR-1300-R)
When installed horizontally:
B = 150 mm
F = 200 mm
Fig. 3: Infrared radiator safety distances
150 100
BF
EN
Instructions for installation and use p. 11/16
5.2. Installation cut-out
Please note and .Fig. 1 Fig. 4
350W
155
665
350W
155
500W / 750W / 1300 W
825
Fig. 4: Infrared radiator installation cut-outs
Dimensions in mm
Instructions for installation and use p. 12/16
5.3. Recessed
Please note and .Fig. 2 Fig. 5
C
BA
Fig. 5: Installation of infrared radiators without and with optional stainless
steel panel
BA
CAUTION!
Make sure that the terminal box for the radiator is on top!
An intumescent strip is included with the 1300 W infrared radiator. Stick this to
the outer edge of the cut-out before installing the radiator (see A in Fig. 5)
A Cabin wall cut-out
B Infrared radiator
C Stainless steel panel (optional)
EN
Instructions for installation and use p. 13/16
6. Cleaning and maintenance
6.1. Cleaning
6.2. Maintenance
The infrared radiator is maintenance-free.
ATTENTION!
Damage to the unit
The infrared radiator is protected against splashing water, however direct contact
with water could still damage it.
NEVER immerse the device in water.
Do not pour water over the device.
Do not get the device too wet when cleaning it.
Dispose of packaging materials in accordance with the applicable
waste disposal regulations.
Used devices contain reusable materials as well as hazardous
substances. Therefore, do not dispose of your used device with
household waste, but do so in accordance with the locally appli-
cable regulations.
7. Disposal
1. Switch o the radiator
2. Allow the radiator to cool down
3. Carefully wipe down the glass with a damp cloth.
Instructions for installation and use p. 14/16
8. Technical data
General, for all radiators
Storage conditions: -25°C to +70°C
Ambient temperature: +10°C to +140°C
Mains voltage: 230 V ~ 1N 50 Hz
Thermal fuse: 130°C
IP code: IPX2
Connection cable: 3 m - 3 x 1.5 mm² insulated with plug
Radiation angle: 122.5°
178
150
71
686
818
61 63
EN
Instructions for installation and use p. 15/16
DIR-350-R
Dimensions: L1 = 523 mm, L2 = 658 mm
Front glass: Schott Nextrema, dark (1-027-840)
Radiator element: 350 W - Vitae (1-027-836)
DIR-500-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, dark (1-027-839)
Radiator element: 500 W - Vitae (1-027-837)
DIR-750-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, dark (1-027-839)
Radiator element: 750 W - Vitae (1-027-838)
DIR-1300-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, dark (1-027-839)
Radiator element: 1300 W - Vitae (1-027-835)
WIR-350-R
Dimensions: L1 = 523 mm, L2 = 658 mm
Front glass: Schott Nextrema, white (1-027-842)
Radiator element: 350 W - ECO full spectrum (1-027-783)
WIR-500-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, white (1-027-841)
Radiator element: 500 W - ECO full spectrum (1-027-786)
WIR-750-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, white (1-027-841)
Radiator element: 750 W - ECO full spectrum (1-027-789)
WIR-1300-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Schott Nextrema, white (1-027-841)
Radiator element: 1300 W - Vitae (1-027-835)
Instructions for installation and use p. 16/16
ECO-350-R
Dimensions: L1 = 523 mm, L2 = 658 mm
Front glass: Glass ceramic, dark (1-030-968)
Radiator element: 350 W - ECO full spectrum (1-027-783)
ECO-500-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Glass ceramic, dark (1-030-969)
Radiator element: 500 W - ECO full spectrum (1-027-786)
ECO-750-R
Dimensions: L1 = 686 mm, L2 = 818 mm
Front glass: Glass ceramic, dark (1-030-969)
Radiator element: 750 W - ECO full spectrum (1-027-789)
ECO-350-G
Dimensions: L1 = 523 mm, L2 = 658 mm
Front: Metal grille, black bre coated (1-027-791)
Radiator element: 350 W - ECO full spectrum (1-027-783)
ECO-500-G
Dimensions: L1 = 686 mm, L2 = 818 mm
Front: Metal grille, black bre coated (1-027-792)
Radiator element: 500 W - ECO full spectrum (1-027-786)
MONTAGE- UND GEBRAUCHSANWEISUNG
Deutsch
Version 12/20 Ident-Nr. 1-052-822
DE
Vollspektrum-Strahler
VITAE 350 / 500 / 750 / 1300
ECO 350 / 500 / 750
1-027-780 / DIR-350-R 1-027-845 / WIR-350-R
1-027-781 / DIR-500-R 1-027-846 / WIR-500-R
1-027-782 / DIR-750-R 1-027-847 / WIR-750-R
1-027-779 / DIR-1300-R 1-027-844 / WIR-1300-R
1-027-785 / ECO-350-R 1-027-784 / ECO-300-G
1-027-788 / ECO-500-R 1-027-787 / ECO-500-G
1-027-790 / ECO-750-R
Inhaltsverzeichnis
1. Zu dieser Anleitung 3
2. Wichtige Hinweise zu Ihrer Sicherheit 4
2.1. Bestimmungsgemäßer Gebrauch 4
2.2. Sicherheitshinweise 4
3. Produktbeschreibung 7
3.1. Lieferumfang 7
3.2. Produktfunktionen 7
3.3. Optionales Zubehör 7
4. Korrekte Platzierung 8
5. Montage und Anschluss 9
5.1. Sicherheitsabstände 10
5.2. Montageausschnitt 11
5.3. Einbau 12
6. Reinigung und Wartung 13
6.1. Reinigung 13
6.2. Wartung 13
7. Entsorgung 13
8. Technische Daten 14
DE
Montage- und Gebrauchsanweisung S. 3/16
1. Zu dieser Anleitung
Lesen Sie diese Montageanleitung gut durch und bewahren Sie sie in der Nähe
der Infrarotstrahler auf. So können Sie jederzeit Informationen zu Ihrer Sicherheit
und der Verwendung nachlesen.
Symbole in Warnhinweisen
In dieser Montageanleitung ist vor Tätigkeiten, von denen eine Gefahr ausgeht,
ein Warnhinweis angebracht. Befolgen Sie diese Warnhinweise unbedingt. So
vermeiden Sie Sachschäden und Verletzungen, die im schlimmsten Fall sogar
tödlich sein können.
In den Warnhinweisen werden Signalwörter verwendet, die folgende Bedeutun-
gen haben:
GEFAHR!
Wenn Sie diesen Warnhinweis nicht beachten, sind Tod oder schwere
Verletzungen die Folge.
WARNUNG!
Wenn Sie diesen Warnhinweis nicht beachten, können Tod oder schwere
Verletzungen die Folge sein.
VORSICHT!
Wenn Sie diesen Warnhinweis nicht befolgen, können leichte Verletzun-
gen die Folge sein.
ACHTUNG!
Dieses Signalwort warnt Sie vor Sachschäden.
Andere Symbole
Dieses Symbol kennzeichnet Tipps und nützliche Hinweise.
Nicht abdecken! Bedienungsanleitung lesen
Sie nden diese Montage- und Gebrauchsanweisung auch im Download-
bereich unserer Webseite auf www.sentiotec.com/downloads.
Montage- und Gebrauchsanweisung S. 4/16
2. Wichtige Hinweise zu Ihrer Sicherheit
Der Infrarot-Strahler ist nach anerkannten sicherheitstechnischen
Regeln gebaut. Dennoch können bei der Verwendung Gefahren
entstehen. Befolgen Sie deshalb die folgenden Sicherheitshinweise
und die speziellen Warnhinweise in den einzelnen Kapiteln.
2.1. Bestimmungsgemäßer Gebrauch
Der Infrarot-Strahler dient zur Erwärmung des menschlichen rpers
und/oder zur Erwärmung einer Infrarot-Kabine.
Der Infrarot-Strahler darf nur in Kombination mit einer Steuerung
mit automatischer Heizzeitbegrenzung betrieben werden.
Jeder daber hinausgehende Gebrauch gilt als nicht bestimmungs-
gemäß. Nicht bestimmungsgemäßer Gebrauch kann zur Beschä-
digung des Produkts, zu schweren Verletzungen oder Tod führen.
2.2. Sicherheitshinweise
Die Montage der Klemmverbindungen darf nur durch eine Elek-
trofachkraft oder eine vergleichsweise qualizierte Person aus-
geführt werden.
Die Montage der Steckverbindungen darf durch den Anwender
ausgeführt werden.
Montage- und Anschlussarbeiten der Infrarot-Strahler dürfen nur
im spannungsfreien Zustand durchgeführt werden.
Beachten Sie auch die örtlichen Bestimmungen am Aufstellort.
Die Vorschriften nach EN 60335-2-53 (VDE 0700 Teil 53) sind
zu beachten.
DE
Montage- und Gebrauchsanweisung S. 5/16
Geben Sie acht, dass der Infrarot-Strahler keiner mechanischen
Belastung ausgesetzt wird, dies führt zum Bruch. Strahler mit
gebrochener Glasfront oder Strahlerelement dürfen nicht mehr
benutzt werden. Das Glas oder das Strahlerelement muss ge-
tauscht werden (Artikelnummer siehe 8. Technische Daten auf
Seite 14)
Bei der Positionierung und dem Einbau des Infrarot-Strahlers
müssen die minimalen Sicherheitsabstände eingehalten werden
(siehe 5.2. Sicherheitsabstände auf Seite 10)
Der Strahler erfüllt die Anforderungen gemäß IPX2. Für den
spritzwassergeschützten Einbau, nach IPX4, ist eine Verblen-
dung des Randes des Infrarot-Strahlers notwendig (z. Bsp.:
Edelstahlblende, siehe 3.2. Optionales Zubehör auf Seite 7)
Der Einbau der Strahler in ein Dampfbad ist nicht zulässig.
Bei Problemen, die in der Gebrauchsanweisung nicht ausführ-
lich genug behandelt werden, wenden Sie sich zu Ihrer eigenen
Sicherheit an Ihren Lieferanten.
Stellen Sie sicher, dass keine brennbaren Gegenstände auf
oder vor dem Infrarot-Strahler hängen, bevor Sie die Infrarot-
steuerung einschalten.
Berühren Sie niemals das Glas des Infrarot-Strahlers während
des Betriebs. Das Glas des Infrarot-Strahlers wird sehr heiß.
Abhängig von der Benutzerfunktion ist ggf. die Montage eines
Berührschutzes notwendig (z. Bsp.: Holzlehne, Schutzgitter,
siehe 3.2. Optionales Zubehör auf Seite 7).
Das Gerät darf nicht von Kindern unter 8 Jahren verwendet
werden.
DE
Montage- und Gebrauchsanweisung S. 7/16
3. Produktbeschreibung
3.1. Lieferumfang
IR-Strahler inkl. 3 m Anschlusskabel mit Stecker
Montageanleitung
3.2. Produktfunktionen
Der Infrarot-Strahler verfügt über folgende Funktionen:
Einbau als Rücken-, Front - oder Deckenstrahler
Eigensicher durch Sicherheitstemperturbegrenzer
Stufenlos dimmfähig
Modelle mit Glas-Abdeckung bieten im eingebauten Zustand in Kombina-
tion mit Frontblende oder Holzlehne den Schutzgrad IPX4 (geeignet für
Saunen)
VITAE Vollspektrumstrahler Nextrema dunkel
Strahlungsintensität: A 24%, B 55%, C 21%
Nextrema Vollspektrumstrahler weiß
Strahlungsintensität: A 9%, B 57%, C 34%
ECO Vollspektrumstrahler mit Glas
Strahlungsintensität: A 24%, B 55%, C 21%
ECO Vollspektrumstrahler mit Gitter
Strahlungsintensität: A 14%, B 40%, C 46 %
3.3. Optionales Zubehör
Frontblende Edelstahl gebürstet
(350W/1-027-948, 500/750/1300W/1-027-779)
Frontblende Edelstahl schwarz lackiert
(350W/1-027-905, 500/750/1300W/1-027-157)
Schutzgitter (350/1-027-791, 500W/1-027-792)
Ergonomische Rückenlehne (350/500W/514-L/A/D)
Ergonomische Rückenlehne VitaMy (350W/1-039-182)
Holzlehne Linde (350W/1-028-578, 500/750W/1-032-185)
Montage- und Gebrauchsanweisung S. 10/16
5.1. Sicherheitsabstände
Beachten Sie die angegebenen minimalen Sicherheitsabstände und Abb. 5.
Infrarot-Strahler 350W, 500W
(DIR-350-R / DIR-500-R / WIR-350-R /WIR-500-R /
ECO-350-R / ECO-500-R / ECO-350-G / ECO-500-G)
bei senkrechter Montage: bei waagrechter Montage:
B= 15 mm B= 80 mm
F= 25 mm F= 25 mm
Infrarot-Strahler 750W (DIR-750-R / WIR-750-R / ECO-750-R)
bei waagrechter Montage:
B= 100 mm
F= 150 mm
Infrarot-Strahler 1300W (DIR-1300-R / WIR-1300-R)
bei waagrechter Montage:
B= 150 mm
F= 200 mm
Abb. 3: Sicherheitsabstände Infrarot-Strahler
150 100
BF
DE
Montage- und Gebrauchsanweisung S. 11/16
5.2. Montageausschnitt
Beachten Sie undAbb. 3 Abb. 6.
350W
155
665
350W
155
500W / 750W / 1300 W
825
Abb. 4: Montageausschnitte Infrarot-Strahler
Maße in mm
DE
Montage- und Gebrauchsanweisung S. 13/16
6. Reinigung und Wartung
6.1. Reinigung
6.2. Wartung
Der Infrarotstrahler ist wartungsfrei.
ACHTUNG!
Schäden am Gerät
Der Strahler ist spritzwassergeschützt, trotzdem kann direkter Kontakt mit Wasser
das Gerät beschädigen.
Tauchen Sie das Gerät NIEMALS in Wasser.
Übergießen Sie das Gerät nicht mit Wasser.
Reinigen Sie das Gerät nicht zu feucht.
Entsorgen Sie die Verpackungsmaterialien nach den gültigen
Entsorgungsrichtlinien.
Altgete enthalten wiederverwendbare Materialien, aber auch
schädliche Stoe. Geben Sie Ihr Altgerät deshalb auf keinen Fall
in den Restmüll, sondern entsorgen Sie das Gerät nach den örtlich
geltenden Vorschriften.
7. Entsorgung
1. Strahler ausschalten
2. Strahler abkühlen lassen
3. Wischen Sie das Glas vorsichtig mit einem feuchten Tuch ab.
Montage- und Gebrauchsanweisung S. 16/16
ECO-350-R
Abmessung: L1=523mm, L2=658 mm
Frontglas: Glas Keramik dunkel (1-030-968)
Strahlerelement: 350W - ECO Vollspektrum (1-027-783)
ECO-500-R
Abmessung: L1=686mm, L2=818 mm
Frontglas: Glas Keramik dunkel (1-030-969)
Strahlerelement: 500W - ECO Vollspektrum (1-027-786)
ECO-750-R
Abmessung: L1=686mm, L2=818 mm
Frontglas: Glas Keramik dunkel (1-030-969)
Strahlerelement: 750W - ECO Vollspektrum (1-027-789)
ECO-350-G
Abmessung: L1=523mm, L2=658 mm
Front: Metallgitter schwarz befockt (1-027-791)
Strahlerelement: 350W - ECO Vollspektrum (1-027-783)
ECO-500-G
Abmessung: L1=686mm, L2=818 mm
Front: Metallgitter schwarz befockt (1-027-792)
Strahlerelement: 500W - ECO Vollspektrum (1-027-786)

Termékspecifikációk

Márka: Harvia
Kategória: nincs kategorizálva
Modell: Wave.com4 DIR-500-R

Szüksége van segítségre?

Ha segítségre van szüksége Harvia Wave.com4 DIR-500-R, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Harvia

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

MOZA

MOZA SR-P Útmutató

10 Április 2025
CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025