Használati útmutató Haas+Sohn ORSTED
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Haas+Sohn ORSTED (11 oldal) a Fűtő kategóriában. Ezt az útmutatót 10 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/11

3
General instructions for operation,
installation and maintenance
FIREPLACE STOVES
HAAS + SOHN Rukov s.r.o.
MANUFACTURER:
SNP 474, 408 01 RUMBURK, CZECH REPUBLIC
COMPANY ID: 62740989 TAX ID: CZ62740989
CONTENTS
1. TECHNICAL SPECIFICATIONS................................................................................................ 5
1.1. Heating concept ......................................................................................................................... 5
1.2. Construction design.................................................................................................................... 5
2. BURNING PROCESS ............................................................................................................... 6
2.1. Fuel volume and burning process adjustments .......................................................................... 6
2.2. Fuel .......................................................................................................................................... 7
3. SAFE OPERATION ................................................................................................................... 7
3.1. General requirements................................................................................................................. 7
3.2. Safe distance between the fireplace stove and flammable material........................................... 8
3.3. Safe distance between the smoke flue and flammable material................................................. 8
3.4. Directions for safe operation .....................................................................................................8
4. INSTALLATION AND CONNECTION TO THE CHIMNEY........................................................ 9
4.1. Connection to the chimney or chimney insert............................................................................. 9
4.2. Connection to the chimney vent ................................................................................................. 9
4.3. Directions for smoke flue installation ......................................................................................... 9
4.4. Installation of the fireplace stove within the room ...................................................................... 10
4.5. Cleaning the heating device and chimney ................................................................................. 10
4.6. Chimney fire .............................................................................................................................. 10
4.7. External combustion air supply system ..................................................................................... 10
5. OPERATING INSTRUCTIONS .................................................................................................. 10
5.1. Before first operation.................................................................................................................. 10
5.2. Setting the fire............................................................................................................................ 11
5.3. Feeding the fire .......................................................................................................................... 11
5.4. Glass cleanness......................................................................................................................... 11
5.5. Operation during temporary period and at worsened weather conditions .................................. 12
5.6. How to substitute the blind element by the exchanger............................................................... 12
5.7. Ash removal ............................................................................................................................... 12
6. CLEANING AND MAINTENANCE ............................................................................................ 12
6.1. Cleaning the heating device....................................................................................................... 12
6.2. Cleaning the ceramics and tiles ................................................................................................. 13
6.3. Sealing lines and tapes .............................................................................................................. 13
6.4. Spare parts................................................................................................................................. 13
7. WHAT TO DO IF...DO YOU DO IT YOURSELF?...................................................................... 13-14
8. FREQUENT PROBLEMS AND QUESTIONS ........................................................................... 14
8.1. Cracked (released) fireclay (vermiculite) brick in the burning area............................................. 14
8.2. Broken glass .............................................................................................................................. 15
8.3. Partitions to control the chimney effect....................................................................................... 15
8.4. Cracked side tile......................................................................................................................... 15
8.5. The blind element substituted by an exchanger (optional) ......................................................... 15
9. PRODUCT LIABILITY AND SERVICE...................................................................................... 16
9.1. General ...................................................................................................................................... 16
9.2. Conditions for guarantee............................................................................................................ 16
9.3. Guarantee and post-guarantee service...................................................................................... 16
9.4. Claim rejected ............................................................................................................................ 16
9.5. How to make a claim.................................................................................................................. 17
9.6. How to order spare parts............................................................................................................ 17
10. MISCELLANEOUS .................................................................................................................... 17
10.1. Accessories supplied with the insert........................................................................................... 17
10.2. Special accessories (on order)................................................................................................... 17
10.3. Recommended spare parts........................................................................................................ 17
10.4. Package and waste disposal...................................................................................................... 18
10.5. ES Declaration of Conformity and CE Certificate....................................................................... 18
10.6. HAAS+SOHN Rukov s.r.o Products and Manufacturing Programme........................................ 18
11. SUPPLEMENTS ........................................................................................................................ 19-21
JK 04 164 15 13 14 02 g

Congratulations! You have just bought the stove HAAS + SOHN, a top-quality product.
Thank you very much for your interest and purchase. Kindly read the Operating
Instructions to find out comprehensive information about the function, correct use and
handling. We recommend you to read the instructions carefully in order to avoid any risk
related to likely damage. Proper operation and maintenance affects the service life of the
product as well. In addition, proper operation and fuel supply is connected with fuel savings
and environment protection. Technical specifications are included in the manual.
The manufacturer provides guarantee providing you adhere to the directions and
recommendations in the instructions for operation and maintenance. Keep the operating
instructions and technical card safe to be able to refresh your knowledge at the beginning
of the new heating season.
1. TECHNICAL SPECIFICATIONS
The fireplace stove is designed for heating in habitable rooms, recreational buildings, work
stations and other places to provide thermal comfort, while the visual effect – the
perception connected with flame – is similar to the sensation of live fire.
1.1. Heating concept
The fireplace stove is designed for burning wood, eco-fuel cakes and coal cakes (specific
types only) in a burning-through way, characteristic with very good firing conditions.
The air within the room is heated thus the thermal comfort is provided by heat convection,
in part by heat radiation as well. This way, you can heat up even very cold, long-time
unheated rooms very quickly. The concept of heating by means of heat convection is based
on the fact that the air in the room enters the fireplace stove at its bottom part, being heated
in the course of its way up inside the convection space consisting of a double shell of the
heating device. The air then flows through the holes in the upper part of the fireplace stove
back in the room. The radiation heat is generated by means of surface areas of the
fireplace stove (metal, ceramics, glass). Due to the construction, the biggest radiation heat
source is the glass door.
1.2. Construction design
The fireplace stove is welded of steel profiles, thickness 2-5 mm. In the middle of the
fireplace stove, there is a firing chamber that may be closed with a stocking door (equipped
with a self-acting element). The door is provided with special a large-area glass sheet,
thermal resistance up to 800 C. °
The inner space of the firing chamber is usually lined with fireclay brick shapes. The bricks
are not jointed with any filler (the reason is a protection of the bricks against damage by
thermic dilatation). The upper part of the firing chamber is equipped with partitions
designed for directing flue gases into a smoke outlet. The partitions may be fixed or
movable. Such movable partition may serve as a supporting holder for fireclay bricks. At
the bottom part of the firing chamber, a simple, fixed cast grate is installed. Before the
grate, a barrier is usually provided, to prevent from burning pieces falling out or onto the
door (front glass). Under the grate, there is a space designed for ashpan. The remaining
space at the bottom part of the fireplace stove may be used for spare fuel.
Fireplace stove casing is made of steel panels, ceramic tiles or lined of thick tiles. The
fireplace stove steel construction is protected with special refractory paint.
Caution! The fireplace stove is not designed for continuous heating but for
periodical – interrupted (i.e. temporary) operation.
4 5

2. FIRING PROCESS
2.1. Fuel quantity and firing process adjustments
Burning wood, wood cakes (or coal cakes – optional) in the fireplace stove is based on
burning through the fuel, which means that such firing takes place throughout the whole go
of the fuel at a time. In order to provide optimal conditions for easy kindling and burning
up, you need enough air being led under the fuel in fire, through the grate: this is the so-
called air, and it must be always adjustable. By increasing temperature of the fuel primary
burning through, certain gaseous components of the fuel evolve that – unless additional air
is supplied – would be of no avail in terms of heat energy: therefore, additional air must be
provided at the flame level where the firing process connected with those gaseous
components may continue. Now, at this stage, the primary air is – in fact – not necessary,
while air supply is required, or air may be added as well, respectively. secondary tertiary
The secondary air supply, usually adjustable, improves the firing process and contributes to
the door glass self- cleaning. The tertiary air supply is designed for general improvement of
the firing process and is usually fixed (one cannot regulate it in any way). If the proportion
of the air volumes led into the particular sections of the firing chamber is correct, the
burning efficiency is increased while emission of pollutants in the environment is reduced.
The layout of the air supply regulative elements is shown in the Technical Cart (a part of
the documentation supplied with the fireplace stove).
Our models of fireplace stove may reach up to 85% efficiency – which means top
performance.
The heating capacity of the heating device depends on the fuel quantity burnt per defined
time, fuel quality and firing process efficiency. Using the Chart 2 (heating values) may
help you to make a picture of attainable capacity: let’s assume that you burn 1 kg of
wood per hour, wood humidity is 20%. Further, with higher wood moisture its heating
capacity goes down.
In the testing room conditions, adjustability of the heating device was tested, within 30 –
100% of nominal performance. For the regulation, the chimney effect and the fuel quantity
were applied. In practice, the heating capacity may be regulated by means of air supply
regulating elements (especially the primary air inlet). There is no simple and explicit way to
determine the firing process adjustment by means of regulators. There are many aspects to
consider – fuel moisture, type of fuel, chimney effect, exterior pressure conditions, etc.
Therefore, the firing process (the flame intensity and quality) should be re-adjusted for
particular conditions.
You will be able to adjust the firing process to achieve best efficiency after a short time of
operation. A detailed chart showing how to adjust the air supply regulating elements is
included in the technical specifications. The figures in the chart are the testing results
verified by the State Testing Laboratory. The Chart 1 presents just general information for
air supply adjustment.
Primary air
Secondary air Tertiary air
Fuel
Fuel quantity
Adjustable
Adjustable
No adjustment
wooden logs
wood cakes
2 - 3 logs (approx. 2 – 3 kg)
2 - 4 logs (approx. 2 – 3 kg)
Open wide Fixed adjustment
at installation
coal cakes 2 - 3 logs (approx. 2 – 3 kg)
Closed or open
(depends on local
conditions)
half-open Fixed adjustment
at installation
Chart 1
Our tips for wood burning
Any time you set the fire, let the primary air regulator open long enough to allow the fuel
burning properly.
Before you re-load, it is recommended to open the primary air regulator wide.
While burning wood, make sure the wood is dry, maximum moisture 20%.
Our tips for coal cake burning (selected models only)
• To achieve optimisation of the firing process, load the cakes directly onto the grate
holes: this way, you support the burning in best possible way.
• Make sure you do not overload: for the heat capacity you may use, i.e. to maintain the
heat, a couple of cakes is enough: otherwise the device would suffer from excessive
heat. Coal cake fuel efficiency may reach 6 kWh/1 kg, i.e. by some 40% more
than wood!
2.2. Fuel
In fireplace stoves, you may burn logs, wood cakes and coal cakes (some models only).
The moisture of the wood to be burnt should be lower than 20%, optimally 10%. The rule of
thumb is: the less water in the fuel, the higher heating capacity you achieve. For the
recommended wood moisture, you may reach it safely if you store the wood in a well
ventilated shelter for at least two years. The water content in coal cakes should be
specified by the manufacturer. The cakes should be stored in a dry room otherwise they
disintegrate. It is recommended to store the wood intended for burning in pieces approx. 3-
6 cm (diameter), 20–30 cm (length). It is forbidden to load and burn coal or charred
coal. In the fireplace, never burn flammable liquids or waste. It is forbidden to burn
papering, chipboards, plastic materials, penetrated wood, wood shavings or saw dust.
Burning such materials not only is detrimental to the environment but shortens the service
life of the heating device as well: you might seriously damage the device or the chimney as
well.
Note: The bark, a part of wooden logs, is no issue at all.
Fuel efficiency: selected types of wood at moisture 20%
Wood Fuel efficiency
kWh/m3
Fuel efficiency
kWh/1 kg
Weight kg/(m3)
Spruce, fir 1957 4,0 485
Larch 2461 4,0 610
Pine 2280 4,0 565
Oak, beech 2743 3,8 726
Chart 2
3. SAFE OPERATION
3.1. General requirements
While installing and operating stove (stove insert), it is obligatory to adhere to the fire
prevention regulations (related to this type of devices) in force in the country of
installation.
6 7
Termékspecifikációk
Márka: | Haas+Sohn |
Kategória: | Fűtő |
Modell: | ORSTED |
Szüksége van segítségre?
Ha segítségre van szüksége Haas+Sohn ORSTED, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Fűtő Haas+Sohn

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024

23 Augusztus 2024
Útmutatók Fűtő
- Fűtő Mestic
- Fűtő Beko
- Fűtő Dometic
- Fűtő Electrolux
- Fűtő Nedis
- Fűtő Milwaukee
- Fűtő Parkside
- Fűtő Candy
- Fűtő Philips
- Fűtő Gorenje
- Fűtő Adler
- Fűtő Princess
- Fűtő SilverCrest
- Fűtő Bosch
- Fűtő NewAir
- Fűtő Zanussi
- Fűtő MPM
- Fűtő AEG
- Fűtő Emerio
- Fűtő Einhell
- Fűtő Bartscher
- Fűtő Maxwell
- Fűtő HP
- Fűtő Hyundai
- Fűtő Scarlett
- Fűtő Tefal
- Fűtő HQ
- Fűtő Bestway
- Fűtő Emos
- Fűtő Corbero
- Fűtő Camry
- Fűtő Xiaomi
- Fűtő Danby
- Fűtő DeLonghi
- Fűtő Clean Air Optima
- Fűtő Heinner
- Fűtő Infiniton
- Fűtő Sunbeam
- Fűtő Beurer
- Fűtő Trumatic
- Fűtő Ariete
- Fűtő Wilfa
- Fűtő Klarstein
- Fűtő Medisana
- Fűtő VOX
- Fűtő Scheppach
- Fűtő Vivax
- Fűtő Conceptronic
- Fűtő Thomson
- Fűtő Fagor
- Fűtő Unold
- Fűtő SHX
- Fűtő Brentwood
- Fűtő Ardes
- Fűtő Cuisinart
- Fűtő Eden
- Fűtő Rommelsbacher
- Fűtő Eurolite
- Fűtő Jocel
- Fűtő Duronic
- Fűtő Bimar
- Fűtő Solis
- Fűtő Clatronic
- Fűtő Bomann
- Fűtő Bauknecht
- Fűtő Hama
- Fűtő Dyson
- Fűtő Ambiano
- Fűtő Cecotec
- Fűtő Sencor
- Fűtő Pelgrim
- Fűtő Qlima
- Fűtő Baxi
- Fűtő Innoliving
- Fűtő Rowenta
- Fűtő Güde
- Fűtő Eta
- Fűtő Izzy
- Fűtő Nevir
- Fűtő JANDY
- Fűtő GoldAir
- Fűtő Domo
- Fűtő Russell Hobbs
- Fűtő Caso
- Fűtő Solac
- Fűtő Carson
- Fűtő Stiebel Eltron
- Fűtő Create
- Fűtő Crane
- Fűtő Mora
- Fűtő Black & Decker
- Fűtő G3 Ferrari
- Fűtő Enders
- Fűtő Global
- Fűtő Severin
- Fűtő Livington
- Fűtő Orbegozo
- Fűtő Lenoxx
- Fűtő Livoo
- Fűtő Eberle
- Fűtő ARGO
- Fűtő OK
- Fűtő Guzzanti
- Fűtő Concept
- Fűtő DCS
- Fűtő DEDRA
- Fűtő SVAN
- Fűtő SPC
- Fűtő Nobo
- Fűtő TriStar
- Fűtő Zelmer
- Fűtő Suntec
- Fűtő BaseTech
- Fűtő Zodiac
- Fűtő RYOBI
- Fűtő Fantini Cosmi
- Fűtő Koenic
- Fűtő Chauvet
- Fűtő Midea
- Fűtő Steba
- Fűtő Trisa
- Fűtő Heller
- Fűtő Kogan
- Fűtő Honeywell
- Fűtő Truma
- Fűtő Broan
- Fűtő Mesko
- Fűtő Velleman
- Fűtő Dimplex
- Fűtő Master
- Fűtő Kenmore
- Fűtő Thermex
- Fűtő Hayward
- Fűtő DCG
- Fűtő Tesy
- Fűtő Melissa
- Fűtő Trotec
- Fűtő Blaupunkt
- Fűtő AstralPool
- Fűtő Korona
- Fűtő Stadler Form
- Fűtő Taurus
- Fűtő Signature
- Fűtő Olympia
- Fűtő Logik
- Fűtő NEO Tools
- Fűtő Hendi
- Fűtő AFK
- Fűtő Konig
- Fűtő H.Koenig
- Fűtő Everdure
- Fűtő DeWalt
- Fűtő Kalorik
- Fűtő Waldbeck
- Fűtő Alpina
- Fűtő Philco
- Fűtő Brandson
- Fűtő ECG
- Fűtő Stanley
- Fűtő Danfoss
- Fűtő Rotel
- Fűtő Vemer
- Fűtő Vornado
- Fűtő Ufesa
- Fűtő Vonroc
- Fűtő Rinnai
- Fűtő Cotech
- Fűtő Argoclima
- Fűtő Ausclimate
- Fűtő WAGAN
- Fűtő Beper
- Fűtő Bestron
- Fűtő Breville
- Fűtő Orion
- Fűtő Soler & Palau
- Fűtő SereneLife
- Fűtő Ravanson
- Fűtő Teesa
- Fűtő Lavorwash
- Fűtő Becken
- Fűtő ATIKA
- Fűtő OneConcept
- Fűtő Haeger
- Fűtő Olimpia Splendid
- Fűtő EasyMaxx
- Fűtő Maxxmee
- Fűtő Orava
- Fűtő Vitek
- Fűtő Eurom
- Fűtő Mill
- Fűtő Maestro
- Fűtő Eureka
- Fűtő Sogo
- Fűtő Sonnenkönig
- Fűtő Fluval
- Fűtő Lifesmart
- Fűtő Flama
- Fűtő Tectro
- Fűtő Fenix
- Fűtő Zibro
- Fűtő Quigg
- Fűtő AKO
- Fűtő Invicta
- Fűtő Ferm
- Fűtő Haverland
- Fűtő Calor
- Fűtő Sinbo
- Fűtő Jata
- Fűtő Swan
- Fűtő Anslut
- Fűtő Sun Joe
- Fűtő EWT
- Fűtő Mellerware
- Fűtő Nestor Martin
- Fűtő Termozeta
- Fűtő Eldom
- Fűtő Cresta
- Fűtő Defy
- Fűtő Bionaire
- Fűtő Maginon
- Fűtő Otsein-Hoover
- Fűtő Techly
- Fűtő Profile
- Fűtő Ferroli
- Fűtő Real Flame
- Fűtő Evolar
- Fűtő Boretti
- Fűtő Perel
- Fűtő Zibro Kamin
- Fűtő Air King
- Fűtő Proline
- Fűtő Royal Sovereign
- Fűtő King
- Fűtő Malmbergs
- Fűtő Piazzetta
- Fűtő Heylo
- Fűtő Kent
- Fűtő Arnold Rak
- Fűtő CasaFan
- Fűtő Wamsler
- Fűtő Duux
- Fűtő Imetec
- Fűtő Topcraft
- Fűtő Alpatec
- Fűtő Blaze
- Fűtő Sygonix
- Fűtő Primo
- Fűtő Barbecook
- Fűtő Creda
- Fűtő SuperFish
- Fűtő Hema
- Fűtő Plieger
- Fűtő Reer
- Fűtő Zehnder
- Fűtő Napoleon
- Fűtő Essentiel B
- Fűtő Team
- Fűtő Prime3
- Fűtő Blumfeldt
- Fűtő CaterChef
- Fűtő Kambrook
- Fűtő Zephir
- Fűtő Harvia
- Fűtő Dantherm
- Fűtő Brixton
- Fűtő Superior
- Fűtő Kunft
- Fűtő La Nordica
- Fűtő Jotul
- Fűtő Vasco
- Fűtő Noveen
- Fűtő Nectre
- Fűtő Cadel
- Fűtő Grunkel
- Fűtő PAX
- Fűtő Jaga
- Fűtő Lervia
- Fűtő Masport
- Fűtő Weishaupt
- Fűtő REMKO
- Fűtő Extraflame
- Fűtő Lynx
- Fűtő Just Fire
- Fűtő Optimum
- Fűtő Osburn
- Fűtő Euromac
- Fűtő Hartig And Helling
- Fűtő Gutfels
- Fűtő Westfalia
- Fűtő TAIDEN
- Fűtő Veito
- Fűtő Ecoteck
- Fűtő Etherma
- Fűtő Nordic Fire
- Fűtő Eurotronic
- Fűtő Wanders
- Fűtő Tecno Air System
- Fűtő Grandhall
- Fűtő Emga
- Fűtő Adax
- Fűtő Supra
- Fűtő Heatstrip
- Fűtő Escea
- Fűtő Braemar
- Fűtő Bromic Heating
- Fűtő Martec
- Fűtő Jindara
- Fűtő Neo
- Fűtő SPT
- Fűtő Hatco
- Fűtő SunRed
- Fűtő Aerian
- Fűtő IXL
- Fűtő XPower
- Fűtő True North
- Fűtő WestBend
- Fűtő Hortus
- Fűtő Prem-i-air
- Fűtő Quadra-Fire
- Fűtő Mr. Heater
- Fűtő Stenda
- Fűtő Magnavox
- Fűtő VIESTA
- Fűtő Apricus
- Fűtő Heatsome
- Fűtő Brivis
- Fűtő Hubbell
- Fűtő HeatStar
- Fűtő Pacific Energy
- Fűtő Dri Eaz
- Fűtő Regency
- Fűtő Burley
- Fűtő Monzana
- Fűtő Invroheat
- Fűtő Kaden
- Fűtő Jarden
- Fűtő Noirot
- Fűtő Ouellet
- Fűtő AccuLux
- Fűtő Gossmann
- Fűtő Wulfe
- Fűtő Duro Pro
- Fűtő Herschel
- Fűtő Casaya
- Fűtő HyCell
- Fűtő TURBRO
- Fűtő Radialight
- Fűtő Sunheat
- Fűtő Heidenfeld
- Fűtő Hcalory
- Fűtő Rowi
- Fűtő Neopower
- Fűtő Arlec
- Fűtő Guardian
- Fűtő Big Ass Fans
- Fűtő Pureheat
- Fűtő EvoHeat
- Fűtő Bromic
- Fűtő MSW
- Fűtő Solamagic
- Fűtő Contura
- Fűtő Mirpol
- Fűtő Alkari
- Fűtő Longvie
- Fűtő Blue Rhino
- Fűtő Rheem
- Fűtő Gasmate
- Fűtő Ionmax
- Fűtő Airo
- Fűtő Mission Air
- Fűtő Omega Altise
- Fűtő Scandia
- Fűtő Vasner
- Fűtő Fire Sense
- Fűtő InfraNomic
- Fűtő Heat Storm
- Fűtő Excelair
- Fűtő Heatscope
- Fűtő Heat1
- Fűtő Thermotec
- Fűtő Perfect Aire
- Fűtő AustWood
- Fűtő Uniprodo
- Fűtő Infratech
- Fűtő Yamazen
- Fűtő TANSUN
- Fűtő Universal Blue
Legújabb útmutatók Fűtő

4 Április 2025

30 Március 2025

30 Március 2025

30 Március 2025

30 Március 2025

27 Március 2025

27 Március 2025

27 Március 2025

27 Március 2025

27 Március 2025